Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomic electron tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Modeling Si/SiGe quantum dot variability induced by interface disorder reconstructed from multiperspective microscopy

SiGe heteroepitaxial growth yields pristine host material for quantum dot qubits, but residual interface disorder can lead to qubit-to-qubit variability that might pose an obstacle to reliable SiGe-based quantum computing. By convolving data from scanning tunneling microscopy and high-angle annular dark field scanning transmission electron microscopy, we reconstruct 3D interfacial atomic structure and employ an atomistic multi-valley effective mass theory to quantify qubit spectral variability. The results indicate (1) appreciable valley splitting (VS) variability of ~50% owing to alloy disorder and (2) roughness-induced double-dot detuning bias energy variability of order 1–10 meV depending on well thickness. For measured intermixing, atomic steps have negligible influence on VS, and uncorrelated roughness causes spatially fluctuating energy biases in double-dot detunings potentially incorrectly attributed to charge disorder. Our approach yields atomic structure spanning orders of magnitude larger areas than post-growth microscopy or tomography alone, enabling more holistic predictions of disorder-induced qubit variability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evolution of standardization and dissemination of cryo-EM structures and data jointly by the community, PDB, and EMDB

Cryogenic electron microscopy (cryo-EM) methods began to be used in the mid-1970s to study thin and periodic arrays of proteins. Following a half-century of development in cryo-specimen preparation, instrumentation, data collection, data processing and modeling software, cryo-EM has become a routine method for solving structures from large biological assemblies to small biomolecules at near to true atomic resolution. This review explores the critical roles played by the Protein Data Bank (PDB) and Electron Microscopy Data Bank (EMDB) in partnership with the community to develop the necessary infrastructure to archive cryo-EM maps and associated models. Public access to cryo-EM structure data has in turn facilitated better understanding of structure-function relationships and advancement of image processing and modeling tool development. The partnership between the global cryo-EM community and PDB and EMDB leadership has synergistically shaped the standards for metadata, one-stop deposition of maps and models, and validation metrics to assess the quality of cryo-EM structures. The advent of cryo-electron tomography (cryo-ET) for in situ molecular cell structures at a broad resolution range and their correlations with other imaging data introduces new data archival challenges in terms of data size and complexity in the years to come.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Facile hermetic TEM grid preparation for molecular imaging of hydrated biological samples at room temperature

Abstract Although structures of vitrified supramolecular complexes have been determined at near-atomic resolution, elucidating in situ molecular structure in living cells remains a challenge. Here, we report a straightforward liquid cell technique, originally developed for real-time visualization of dynamics at a liquid-gas interface using transmission electron microscopy, to image wet biological samples. Due to the scattering effects from the liquid phase, the micrographs display an amplitude contrast comparable to that observed in negatively stained samples. We succeed in resolving subunits within the protein complex GroEL imaged in a buffer solution at room temperature. Additionally, we capture various stages of virus cell entry, a process for which only sparse structural data exists due to their transient nature. To scrutinize the morphological details further, we used individual particle electron tomography for 3D reconstruction of each virus. These findings showcase this approach potential as an efficient, cost-effective complement to other microscopy technique in addressing biological questions at the molecular level.

59 BASIC BIOLOGICAL SCIENCES↗

High Mobility and Electrostatics in GeSn Quantum Wells With SiGeSn Barriers

GeSn is an emerging material with potential applications in next‐generation integrated optoelectronics and quantum information processing. While GeSn/SiGeSn quantum wells exhibit promising optical properties, their electrical transport characteristics and governing electrostatics in gated structures remain unexplored. Heterostructure field‐effect transistors are fabricated using GeSn/SiGeSn quantum wells and electronic transport properties of 2D holes are characterized. At 2 K, heterostructure field‐effect transistors with well/barrier compositions of Ge 0.945 Sn 0.055 /Si 0.03 Ge 0.93 Sn 0.04 and Ge 0.9 Sn 0.1 /Si 0.017 Ge 0.927 Sn 0.056 , show peak mobilities of 9000 and 19 000 cm 2 /Vs, respectively, the latter setting a record for the highest mobility reported for GeSn quantum wells with a Sn concentration around 6 % or greater. Remarkably, at low carrier densities, devices with a SiGeSn barrier exhibit mobilities several times higher than previously reported for GeSn quantum wells with a Ge barrier. This higher mobility contrasts with the expectation that alloy scattering from the barrier would reduce carrier mobility. Two mechanisms based on atom probe tomography data analyses are proposed: i) unintentionally improved SiGeSn/GeSn interface and/or ii) reduced alloy scattering from short‐range order. Significant current–voltage hysteresis is observed, with the effective threshold gate voltage shifting by more than 5 V, attributed to non‐equilibrium trapped charge at various interfaces within the SiGeSn heterostructure.

GeSn↗

Applicability of Micro X-Ray Fluorescence Spectroscopy to Astromaterials Curation and Research

Introduction: The Astromaterials Acquisition and Curation Office at NASA’s Johnson Space Center (JSC) curates NASA’s astromaterial sample collections which includes: Apollo samples, Luna samples, Ant-arctic meteorites, cosmic dust particles, microparticle impacts into space-flown materials, Genesis solar wind atoms, Stardust comet Wild-2 particles, Stardust inter-stellar particles, Hayabusa asteroid Itokawa particles, Hayabusa 2 asteroid Ryugu particles, and future OSIRIS-Rex asteroid Bennu particles (landing in Sep-tember, 2023) [1–3]. To enhance JSC’s advanced cu-ration capabilities, we have recently installed a high-performance micro-X-ray fluorescence (µXRF) spec-trometer to assist in sample characterization through rapid, non-destructive, in-situ elemental analyses that do not require the sample preparation protocols (i.e., polishing and carbon-coating) commonly needed for electron beam analyses. With this new instrument, we are capable of detecting all elements down to carbon in a variable-pressure or He-purged chamber for anal-ysis of a wide range of sample types. Here we describe the instrumental set-up, capabilities, and applicability of µXRF analysis to astromaterials curation and re-search. Instrumentation and Methodology: The X-ray fluorescence and computed tomography lab (X-FaCT) lab at JSC is now equipped with a Bruker M4 Tornado Plus µXRF (Fig. 1). This system is an energy-dispersive x-ray spectrometer equipped with two 60 mm2 silicon drift detectors (SDD) that are able to be used simulta-neously for output count rates ~500,000 cps. New light element windows allow detecting and analyzing the entire elemental range from carbon to americium. Two x-ray tubes (micro-focus Rh with polycapillary lenses and W with collimators of 0.5, 1.0, 2.0, and 4.5 mm) with max excitation parameters of 50 kV, 30 W and 50 kV, 40 W, respectively, allow for more flexibility of the analysis of high energy lines. The motorized X-Y-Z stage has a mapping range of 190 x 160 mm and can support samples up to 7 kg (~15.5 lbs) and a height of 120 mm [4]. Analytical modes include elemental analysis (down to ~20 µm spot size) via point, line, or area of bulk materials (rock surfaces, thin sections, thick sections, etc.) as well as coating analysis (determination of thickness and composition) of samples. This system has a variable vacuum chamber (1 mbar to 1 atm) that is also equipped with a He-purge system which accommodates vacuum sensitive samples while still allowing detection of light elements at atmospheric pressure. Utility and Applicability of µXRF in Astro-materials research and exploration science (ARES): Elemental analysis using µXRF is commonly em-ployed for both terrestrial and planetary geological science disciplines [5]. It is especially useful for analy-sis of astromaterials given the limited sample prepara-tion required, which is not feasible for certain materi-als. Here we show select applications of µXRF anal-yses of astromaterials that can, have, and will be done at JSC’s X-FaCT lab. Point analysis: In-situ spot analyses (~20 µm spot size) on a cut slab of Martian meteorite NWA 10922 allowed for the discovery, qualitative elemental analy-sis and determination of different feldspar minerals [6]. These point analyses served as an effective prelim-inary step for subsequent quantitative analyses. Ana-lytical standards can be employed for more accurate quantification of µXRF spot analyses. Area analysis: This analytical mode measures all detectable elements (from C to Am) at each pixel (>5 µm pixel size) in a user-defined area. The results are shown as elemental maps which can be extracted as 16-bit TIFF’s for further data processing. In Fig. 2. we show elemental distribution maps of the high-Ti basalt 73001,531 that have been processed using ImageJ software. From these maps you can accurately and quickly (this map took ~50 mins.) identify mineral components, such as pyroxene, plagioclase, oxides, and phosphates, compositional zoning, and mineral textures. Detection of high-Z phases: µXRF techniques are es-pecially effective at analyzing trace minerals with high-atomic-number (high-Z) elements because the high-energy characteristic X-rays used (relative to SEM EDS) allow for mapping of K lines in elements up to La (typically SEM maps use L X-ray lines for elements >Zn, and these can often have interferences). Thus, µXRF is especially suited for identifying minerals like zircon, baddeleyite, REE-rich phosphates, Fe-rich met-als, oxides, sulfides, and phosphides [4]. In Fig. 3 we show elemental distribution maps for 73001,530 where we are able to correlate the original video image with, Zr, Si, Y and Hf elemental maps together identi-fying the location of a zircon. In this location you would expect lower Si compared to surrounding mate-rial, as well as higher Zr, Y, and Hf content compared to surrounding material, all of which is confirmed by our XRF ele-mental distribution maps (Figure 2.) Conclusions: The new M4 Tornado Plus µXRF within the Astromaterials Acquisition and Curation office at NASA JSC allows for rapid and non-destructive elemental analysis of astromaterials with limited or no sample preparation. µXRF analyses pro-vide crucial compositional knowledge for the prelimi-nary examination and curation of astromaterials. This instrument enhances the advanced curation capabili-ties in the X-FaCT laboratory at JSC by allowing pro-ductive, cohesive, and non-destructive multi-modal x-ray analyses on astromaterial samples, which is neces-sary for the comprehensive curation and study of our current and future astromaterial collections. Addition-ally, µXRF can provide complimentary information to researchers for studies on astromaterials. References: [1] Allen, C. et al., (2011). Chemie De Erde Geochemistry, 71, 1-20. [2] McCubbin, F. M. et al., (2016) 47th LPSC, abstract #2668 [3] Zeigler, R. A. et al., (2017) 48th LPSC, abstract #2772 [4] Bruker User Manual [5] Young et al., (2016) Appl. Geochemistry, 72, 77-87 [6] Mor-ris, R. V. et al., (2023) 54th LPSC.

E W O'Neal↗

Importance of standard terminology in surface chemical analysis: ISO 18115-1:2023, general terms and terms used in spectroscopy

The International Standard ISO 18115-1 on terminology in surface chemical analysis has been revised with clarifications, modifications, and deletions to more than 70 terms and with the addition of more than 50 terms in response to trends, issues, and needs identified by the surface analysis community. This revision adds terminology and concepts associated with emerging methods such as atom probe tomography, near ambient pressure XPS, and hard X-ray photoelectron spectroscopy. It includes 25 new and revised terms to ensure that the description of resolution is consistent across all surface analysis methods. The 630 terms in the document cover words or phrases used in describing the samples, instruments, and concepts involved in surface chemical analysis. Here, the terms have been collated into subject specific sections to ensure that related terms can be found easily.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Cobalt Sites Dispersed in Hierarchically Porous Nanofiber Networks for Durable and High-Power PGM-Free Cathodes in Fuel Cells

Increasing catalytic activity and durability of atomically dispersed metal–nitrogen–carbon (M–N–C) catalysts for the oxygen reduction reaction (ORR) cathode in proton-exchange-membrane fuel cells remains a grand challenge. In this study, a high-power and durable Co–N–C nanofiber catalyst synthesized through electrospinning cobalt-doped zeolitic imidazolate frameworks into selected polyacrylonitrile and poly(vinylpyrrolidone) polymers is reported. The distinct porous fibrous morphology and hierarchical structures play a vital role in boosting electrode performance by exposing more accessible active sites, providing facile electron conductivity, and facilitating the mass transport of reactant. The enhanced intrinsic activity is attributed to the extra graphitic N dopants surrounding the CoN 4 moieties. The highly graphitized carbon matrix in the catalyst is beneficial for enhancing the carbon corrosion resistance, thereby promoting catalyst stability. The unique nanoscale X-ray computed tomography verifies the well-distributed ionomer coverage throughout the fibrous carbon network in the catalyst. The membrane electrode assembly achieves a power density of 0.40 W cm –2 in a practical H 2 /air cell (1.0 bar) and demonstrates significantly enhanced durability under accelerated stability tests. The combination of the intrinsic activity and stability of single Co sites, along with unique catalyst architecture, provide new insight into designing efficient PGM-free electrodes with improved performance and durability.

25 ENERGY STORAGE↗

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Tomographic detection of photon pairs produced from high-energy X-rays for the monitoring of radiotherapy dosing

Measuring the radiation dose reaching a patient’s body is difficult. Here we report a technique for the tomographic reconstruction of the location of photon pairs originating from the annihilation of positron–electron pairs produced by high-energy X-rays travelling through tissue. We used Monte Carlo simulations on pre-recorded data from tissue-mimicking phantoms and from a patient with a brain tumour to show the feasibility of this imaging modality, which we named ‘pair-production tomography’, for the monitoring of radiotherapy dosing. We simulated three image-reconstruction methods, one applicable to a pencil X-ray beam scanning through a region of interest, and two applicable to the excitation of tissue volumes via broad beams (with temporal resolution sufficient to identify coincident photon pairs via filtered back projection, or with higher temporal resolution sufficient for the estimation of a photon’s time-of-flight). In addition to the monitoring of radiotherapy dosing, we show that image contrast resulting from pair-production tomography is highly proportional to the material’s atomic number. The technique may thus also allow for element mapping and for soft-tissue differentiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electron microscopy holdings of the Protein Data Bank: the impact of the resolution revolution, new validation tools, and implications for the future

Abstract As a discipline, structural biology has been transformed by the three-dimensional electron microscopy (3DEM) “Resolution Revolution” made possible by convergence of robust cryo-preservation of vitrified biological materials, sample handling systems, and measurement stages operating a liquid nitrogen temperature, improvements in electron optics that preserve phase information at the atomic level, direct electron detectors (DEDs), high-speed computing with graphics processing units, and rapid advances in data acquisition and processing software. 3DEM structure information (atomic coordinates and related metadata) are archived in the open-access Protein Data Bank (PDB), which currently holds more than 11,000 3DEM structures of proteins and nucleic acids, and their complexes with one another and small-molecule ligands (~ 6% of the archive). Underlying experimental data (3DEM density maps and related metadata) are stored in the Electron Microscopy Data Bank (EMDB), which currently holds more than 21,000 3DEM density maps. After describing the history of the PDB and the Worldwide Protein Data Bank (wwPDB) partnership, which jointly manages both the PDB and EMDB archives, this review examines the origins of the resolution revolution and analyzes its impact on structural biology viewed through the lens of PDB holdings. Six areas of focus exemplifying the impact of 3DEM across the biosciences are discussed in detail (icosahedral viruses, ribosomes, integral membrane proteins, SARS-CoV-2 spike proteins, cryogenic electron tomography, and integrative structure determination combining 3DEM with complementary biophysical measurement techniques), followed by a review of 3DEM structure validation by the wwPDB that underscores the importance of community engagement.

Burley, Stephen K. (ORCID:0000000224879713)↗

Machine Learning for Predictive Performance Analysis in Charged Particle Beam Tools

Imaging methods driven by probes, electrons, and ions have played a dominant role in modern science and engineering. Opportunities for machine vision and AI that focus on consumer problems like driving and feature recognition, are now presenting themselves for automating aspects of the scientific processes. This proposal aims to enable and drive discovery in ultra-low energy implantation by taking advantage of faster processing, flexible control and detection methods, and architecture-agnostic workflows that will result in higher efficiency and shorter scientific development cycles. Custom microscope control, collection and analysis hardware will provide a framework for conducting novel in situ experiments revealing unprecedented insight into surface dynamics at the nanoscale. Ion implantation is a key capability for the semiconductor industry. As devices shrink, novel materials enter the manufacturing line, and quantum technologies transition to being more mainstream. Traditional implantation methods fall short in terms of energy, ion species, and positional precision. Here we demonstrate 1 keV focused ion beam Au implantation into Si and validate the results via atom probe tomography. We show the Au implant depth at 1 keV is 0.8 nm and that identical results for low energy ion implants can be achieved by either lowering the column voltage, or decelerating ions using bias – while maintaining a sub-micron beam focus. We compare our experimental results to static calculations using SRIM and dynamic calculations using binary collision approximation codes TRIDYN and IMSIL. A large discrepancy between the static and dynamic simulation is found that is due to lattice enrichment with high stopping power Au and surface sputtering. Additionally, we demonstrate how model details are particularly important to the simulation of these low-energy heavy-ion implantations. Finally, we discuss how our results pave a way to much lower implantation energies, while maintaining high spatial resolution.

47 OTHER INSTRUMENTATION↗

Molecular axis distribution moments in ultrafast transient absorption spectroscopy: A path toward ultrafast quantum state tomography

In ultrafast time-resolved experiments with gas phase molecules, the alignment of the molecular axis relative to the polarization of the interacting laser pulses plays a crucial role in determining the dynamics following this light–matter interaction. The molecular axis distribution is influenced by the interacting pulses and is intrinsically linked to the electronic coherences of the excited molecules. However, in typical theoretical calculations of such interactions, the signal is either calculated for a single molecule in the molecular frame or averaged over all possible molecular orientations to compare with the experiment. Such averaging removes information about anisotropy in the molecular-axis distribution, even though anisotropic contributions can play a significant role in the measured experimental signal. Here, we calculate the laboratory frame transient electronic first-order polarization [P (1) ] spectra in terms of separated molecular frame and laboratory frame quantities. The laboratory frame polarizations are compared with orientation-averaged quantum master equation calculations, demonstrating that orientation-averaging captures only the isotropic contributions. We show that our formalism also allows us to evaluate the anisotropic contributions to the spectrum. Lastly, we discuss the application of this approach to achieve ultrafast quantum state tomography using transient absorption spectroscopy and field observables in nonlinear spectroscopy.

74 ATOMIC AND MOLECULAR PHYSICS↗

NIRDye 812: A molecular platform tailored for multimodal bioimaging applications of targeted fluorescence- and photoacoustic-guided surgery

The primary treatment for malignant tumors remains to be surgical removal of the diseased tissue. The presence or absence of residual diseased tissue at the tumor margin is the strongest predictor of postoperative prognosis and recurrence. Accordingly, reliance on the ability of surgeons to visually distinguish diseased tissue from healthy tissue unambiguously in real time is crucial. Near infrared-I (NIRsingle bondI) fluorescence-emitting targeting biomolecular constructs such as anticancer antibody-fluorophore conjugates, namely cetuximab-IRDye® 800CW (CTB-IRDye® 800CW), are FDA-approved for clinical trial usage in the fluorescence-guided resection of diseased tissue due to affording improved direct visualization of tumor tissue when compared to the use of either the unaided eye under standard white light illumination (WLI) surgical techniques or non-targeting fluorophores. Unfortunately, though helpful, CTB-IRDye® 800CW affords limited (i) identification of diseased tissue and (ii) tumor margin delineation, because the immunoconjugate generates suboptimal tumor-to-background ratios (TBRs) as a result of its spectral/photophysical profiles poorly aligning with the fixed optical windows of pre-/clinical setups. As such, CTB-IRDye® 800CW is more prone to affording incomplete resection compared to if TBRs were higher due to otherwise. Here, to aid in accurately identifying deep-seated diseased tissue, photoacoustic (PA) tomography has been implemented alongside CTB-IRDye® 800CW to achieve PA signals that could result in higher TBRs. However, in clinical trial practice, using IRDye® 800CW for PA imaging also yields subpar TBRs due to it affording low PA signals. To overcome such limitations, we developed NIRDye 812, a structurally-modified topological equivalent of IRDye® 800CW, to confer it the capability to yield both higher TBRs and superior PA signal than that of the equivalent CTB-conjugate and fluorophore IRDye® 800CW itself, respectively. To do so, we substituted the oxygen atom at its meso-position with a sulfur atom. CTB-NIRDye 812 demonstrated a red-shifted absorption wavelength at 796 nm and a peak NIR-I fluorescence emission wavelength at 820 nm, which better dovetails with the fixed windows of preinstalled fixed emission filters within commercial pre-/clinical NIR-I fluorescence imaging instruments. Overall, CTB-NIRDye 812 provided a ~ 2-fold increase in TBRs compared to those of CTB-IRDye® 800CW in vivo. Also, NIRDye 812 displayed an ~60% higher PA signal than that of IRDye® 800CW. Collectively, we achieved our goal of improving upon the spectral/photophysical and PA properties of IRDye® 800CW via introducing a subtle modification to its electronic core such that its CTB immunoconjugate could potentially allow for fast track or breakthrough designation by the FDA due to its near-identical structure displaying considerably improved efficacy.

59 BASIC BIOLOGICAL SCIENCES↗

Fast ion studies in the extended high-performance high β P plasma on EAST

Comprehending and optimizing fast ion behaviors is critical for the enhancement of performance in Experimental Advanced Superconducting Tokamak (EAST). This study explores the potential benefits of several factors that can improve the fast ion confinement. First, experiments show the change in the direction of the NBI2 from counter-I p to co-I p leads to a significant reduction in fast ion losses. TRANSP/NUBEAM simulation and tomography results based on fast-ion D-alpha measurements reveal that after the neutral beam injection (NBI) upgrade, the beam ion prompt loss is reduced by approximately 50%. Second, the upgraded ion cyclotron resonant frequency (ICRF) antenna at the N-port features twice the coupling resistance of the original antennas at EAST. This improved ICRF power coupling has enhanced the synergistic heating effect of NBI + ICRF, where the ICRF wave field accelerates beam ions at the harmonics. Experiments demonstrate that NBI + ICRF synergistic not only enhances plasma neutron yield and β P , but also accelerates beam ions to hundreds of keV. Further, the electron density and the neutral beam voltage have been optimized to reduce the fast ion slowing-down time and beam ion losses. Experimental and simulation results indicate that increasing the electron density reduces beam ion losses and enhances the bootstrap current fraction. While higher beam voltage results in a slight decrease in beam power absorption, it can increase the fraction of bootstrap current. With the understanding of these optimization of fast ion confinement, experiments have demonstrated fully non-inductive operation at high density (n e /n G ∼ 0.67, β P ∼ 3.1, β N ∼ 2.1, H 98,y2 ∼ 1.2) even without the support of co-I p beam NBI2. This investigation presents a potential regime to enhance fast ion confinement and extend performance in the high β P plasma for future experiments.

EAST tokamak↗

A Proposed Forward Silicon Tracker for the Future Electron-Ion Collider and Associated Physics Studies

The future Electron-Ion Collider (EIC) will explore several fundamental questions in a broad Bjorken-x (x BJ ) and Q 2 phase space. Heavy flavor and jet products are ideal probes to precisely study the tomography of nucleon/nuclei structure, help solve the proton spin puzzle and understand the hadronizaton processes in vacuum or in the QCD medium. Due to the asymmetric collisions at the EIC, most of the final state hadrons are produced in the nucleon/nuclei beam going (forward) direction. A silicon vertex/tracking is critical to precisely measure these forward hadrons at the EIC. Details of different conceptual designs of the proposed Forward Silicon Tracker (FST) and the relevant detector performance are presented in this technical note. The associated heavy flavor and jet studies with the evaluated FST performance are discussed as well.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast Molecular Frame Quantum Tomography

Here, we develop and experimentally demonstrate a methodology for a full molecular frame quantum tomography (MFQT) of dynamical polyatomic systems. We exemplify this approach through the complete characterization of an electronically nonadiabatic wave packet in ammonia (NH 3 ). The method exploits both energy and time-domain spectroscopic data, and yields the lab frame density matrix (LFDM) for the system, the elements of which are populations and coherences. The LFDM fully characterizes electronic and nuclear dynamics in the molecular frame, yielding the time- and orientation-angle dependent expectation values of any relevant operator. For example, the time-dependent molecular frame electronic probability density may be constructed, yielding information on electronic dynamics in the molecular frame. In NH 3 , we observe that electronic coherences are induced by nuclear dynamics which nonadiabatically drive electronic motions (charge migration) in the molecular frame. Here, the nuclear dynamics are rotational and it is nonadiabatic Coriolis coupling which drives the coherences. Interestingly, the nuclear-driven electronic coherence is preserved over longer timescales. In general, MFQT can help quantify entanglement between electronic and nuclear degrees of freedom, and provide new routes to the study of ultrafast molecular dynamics, charge migration, quantum information processing, and optimal control schemes.

74 ATOMIC AND MOLECULAR PHYSICS↗