Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aperture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Aperture design for the third neutron and first gamma-ray imaging systems for the National Ignition Facility

The current construction of a new nuclear-imaging view at the National Ignition Facility will provide a third line of sight for hotspot and cold fuel imaging and the first dedicated line of sight for 4.4-MeV γ-ray imaging of the remaining carbon ablator. To minimize the effort required to hold and align apertures inside the vacuum chamber, the apertures for the two lines of sight will be contained in the same array. We discuss the system requirements for neutron and γ-ray imaging and the resulting aperture array design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Casimir-Polder repulsion near edges: Wedge apex and a screen with an aperture

Although repulsive effects have been predicted for quantum vacuum forces between bodies with nontrivial electromagnetic properties, such as between a perfect electric conductor and a perfect magnetic conductor, realistic repulsion seems difficult to achieve. Repulsion is possible if the medium between the bodies has a permittivity in value intermediate to those of the two bodies, but this may not be a useful configuration. Here, inspired by recent numerical work, we initiate analytic calculations of the Casimir-Polder interaction between an atom with anisotropic polarizability and a plate with an aperture. In particular, for a semi-infinite plate, and, more generally, for a wedge, the problem is exactly solvable, and for sufficiently large anisotropy, Casimir-Polder repulsion is indeed possible, in agreement with the previous numerical studies. In order to achieve repulsion, what is needed is a sufficiently sharp edge (not so very sharp, in fact) so that the directions of polarizability of the conductor and the atom are roughly normal to each other. The machinery for carrying out the calculation with a finite aperture is presented. As a motivation for the quantum calculation, we carry out the corresponding classical analysis for the force between a dipole and a metallic sheet with a circular aperture, when the dipole is on the symmetry axis and oriented in the same direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Producing circular field harmonics inside elliptic magnet apertures with superconducting canted-cosine-theta coils

Superconducting magnets with noncircular aperture are desired for accelerators and many other high-field applications. This paper presents new methods for the analytic design of elliptic bore superconducting accelerator magnets. Part 1 of this work shares the derivation of current to field relations between a sheet current density on an elliptic cylinder and the magnetic field harmonics inside the aperture. This result is explored in the general context of elliptic bore magnet design with relevant scaling laws compared between elliptic and circular bore magnets. In part 2, this approach is applied to the specific geometry of canted-cosine-theta (CCT) accelerator magnets, enabling analytic winding design for single or mixed circular harmonics within elliptic aperture CCT magnets. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Dark Energy Survey Year 3 Results: Three-point shear correlations and mass aperture moments

We present high signal-to-noise measurements of three-point shear correlations and the third moment of the mass aperture statistic using the first 3 years of data from the Dark Energy Survey. We additionally obtain the first measurements of the configuration and scale dependence of the four three-point shear correlations which carry cosmological information. With the third-order mass aperture statistic, we present tomographic measurements over angular scales of 4 to 60 arcminutes with a combined statistical significance of 15.0 σ . Using the tomographic information and measuring also the second-order mass aperture, we additionally obtain a skewness parameter and its redshift evolution. We find that the amplitudes and scale-dependence of these shear 3pt functions are in qualitative agreement with measurements in a mock galaxy catalog based on N-body simulations, indicating promise for including them in future cosmological analyses. We validate our measurements by showing that B-modes, parity-violating contributions and PSF modeling uncertainties are negligible, and determine that the measured signals are likely to be of astrophysical and gravitational origin.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and Test of a Single-Aperture 11 T $ \hbox{Nb}_{3}\hbox{Sn}$ Demonstrator Dipole for LHC Upgrades

The upgrade of the LHC collimation system foresees installation of additional collimators around the LHC ring. The longitudinal space for the collimators could be provided by replacing some 8.33 T NbTi LHC main dipoles with shorter 11 T Nb3Sn dipoles compatible with the LHC lattice and main systems. To demonstrate this possibility, FNAL and CERN have started a joint program with the goal of building a 5.5 m long twin-aperture dipole prototype suitable for installation in the LHC. The first step of this program is the development of a 2 m long single-aperture demonstrator dipole with a nominal field of 11 T at the LHC nominal current of 11.85 kA and ~ 20% margin. This paper describes the design, construction, and test results of the first single-aperture Nb3Sn demonstrator dipole model.

43 PARTICLE ACCELERATORS↗

Developing Magnetorheological Finishing (MRF) Technology for the Manufacture of Large-Aperture Optics in Megajoule Class Laser Systems

Over the last eight years we have been developing advanced MRF tools and techniques to manufacture meter-scale optics for use in Megajoule class laser systems. These systems call for optics having unique characteristics that can complicate their fabrication using conventional polishing methods. First, exposure to the high-power nanosecond and sub-nanosecond pulsed laser environment in the infrared (>27 J/cm{sup 2} at 1053 nm), visible (>18 J/cm{sup 2} at 527 nm), and ultraviolet (>10 J/cm{sup 2} at 351 nm) demands ultra-precise control of optical figure and finish to avoid intensity modulation and scatter that can result in damage to the optics chain or system hardware. Second, the optics must be super-polished and virtually free of surface and subsurface flaws that can limit optic lifetime through laser-induced damage initiation and growth at the flaw sites, particularly at 351 nm. Lastly, ultra-precise optics for beam conditioning are required to control laser beam quality. These optics contain customized surface topographical structures that cannot be made using traditional fabrication processes. In this review, we will present the development and implementation of large-aperture MRF tools and techniques specifically designed to meet the demanding optical performance challenges required in large-aperture high-power laser systems. In particular, we will discuss the advances made by using MRF technology to expose and remove surface and subsurface flaws in optics during final polishing to yield optics with improve laser damage resistance, the novel application of MRF deterministic polishing to imprint complex topographical information and wavefront correction patterns onto optical surfaces, and our efforts to advance the technology to manufacture large-aperture damage resistant optics.

42 ENGINEERING↗

SU-E-T-453: A Novel Daily QA System for Robotic Image Guided Radiosurgery with Variable Aperture Collimator

Purpose: A novel end-to-end system using a CCD camera and a scintillator based phantom that is capable of measuring the beam-by-beam delivery accuracy of Robotic Radiosurgery has been developed and reported in our previous work. This work investigates its application to end-to-end type daily QA for Robotic Radiosurgery (Cyberknife) with Variable Aperture Collimator (Iris). Methods: The phantom was first scanned with a CT scanner at 0.625 slice thickness and exported to the Cyberknife Muliplan (v4.6) treatment planning system. An isocentric treatment plan was created consisting of ten beams of 25 Monitor Units each using Iris apertures of 7.5, 10, 15, 20, and 25 mm. The plan was delivered six times in two days on the Cyberknife G4 system with fiducial tracking on the four metal fiducials embedded in phantom with re-positioning between the measurements. The beam vectors (X, Y, Z) are measured and compared with the plan from the machine delivery file (XML file). The Iris apertures (FWHM) were measured from the beam flux map and compared with the commissioning data. Results: The average beam positioning accuracies of the six deliveries are 0.71 ± 0.40 mm, 0.72 ± 0.44 mm, 0.74 ± 0.42 mm, 0.70 ± 0.40 mm, 0.79 ± 0.44 mm and 0.69 ± 0.41 mm respectively. Radiation beam width (FWHM) variations are within ±0.05 mm, and they agree with the commissioning data within 0.22 mm. The delivery time for the plan is about 7 minutes and the results are given instantly. Conclusion: The experimental results agree with stated sub-millimeter delivery accuracy of Cyberknife system. Beam FWHM variations comply with the 0.2 mm accuracy of the Iris collimator at SAD. The XRV-100 system has proven to be a powerful tool in performing end-to-end type tests for Robotic Image Guided Radiosurgery Daily QA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous beam sampling and aperture shape optimization for SPORT

Purpose: Station parameter optimized radiation therapy (SPORT) was recently proposed to fully utilize the technical capability of emerging digital linear accelerators, in which the station parameters of a delivery system, such as aperture shape and weight, couch position/angle, gantry/collimator angle, can be optimized simultaneously. SPORT promises to deliver remarkable radiation dose distributions in an efficient manner, yet there exists no optimization algorithm for its implementation. The purpose of this work is to develop an algorithm to simultaneously optimize the beam sampling and aperture shapes. Methods: The authors build a mathematical model with the fundamental station point parameters as the decision variables. To solve the resulting large-scale optimization problem, the authors devise an effective algorithm by integrating three advanced optimization techniques: column generation, subgradient method, and pattern search. Column generation adds the most beneficial stations sequentially until the plan quality improvement saturates and provides a good starting point for the subsequent optimization. It also adds the new stations during the algorithm if beneficial. For each update resulted from column generation, the subgradient method improves the selected stations locally by reshaping the apertures and updating the beam angles toward a descent subgradient direction. The algorithm continues to improve the selected stations locally and globally by a pattern search algorithm to explore the part of search space not reachable by the subgradient method. By combining these three techniques together, all plausible combinations of station parameters are searched efficiently to yield the optimal solution. Results: A SPORT optimization framework with seamlessly integration of three complementary algorithms, column generation, subgradient method, and pattern search, was established. The proposed technique was applied to two previously treated clinical cases: a head and neck and a prostate case. It significantly improved the target conformality and at the same time critical structure sparing compared with conventional intensity modulated radiation therapy (IMRT). In the head and neck case, for example, the average PTV coverage D99% for two PTVs, cord and brainstem max doses, and right parotid gland mean dose were improved, respectively, by about 7%, 37%, 12%, and 16%. Conclusions: The proposed method automatically determines the number of the stations required to generate a satisfactory plan and optimizes simultaneously the involved station parameters, leading to improved quality of the resultant treatment plans as compared with the conventional IMRT plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-202-09: Direct-Aperture Optimization for Combined MV+kV Dose Planning in Fluoroscopic Real-Time Tumor-Tracking Radiation Therapy

Purpose: Real-time kV fluoroscopic tumor tracking has the benefit of direct tumor position monitoring. However, there is clinical concern over the excess kV imaging dose cost to the patient when imaging in continuous fluoroscopic mode. This work addresses this specific issue by proposing a combined MV+kV direct-aperture optimization (DAO) approach to integrate the kV imaging beam into a treatment planning such that the kV radiation is considered as a contributor to the overall dose delivery. Methods: The combined MV+kV DAO approach includes three algorithms. First, a projected Quasi-Newton algorithm (L-BFGS) is used to find optimized fluence with MV+kV dose for the best possible dose distribution. Then, Engel’s algorithm is applied to optimize the total number of monitor units and heuristically optimize the number of apertures. Finally, an aperture shape optimization (ASO) algorithm is applied to locally optimize the leaf positions of MLC. Results: Compared to conventional DAO MV plans with continuous kV fluoroscopic tracking, combined MV+kV DAO plan leads to a reduction in the total number of MV monitor units due to inclusion of kV dose as part of the PTV, and was also found to reduce the mean and maximum doses on the organs at risk (OAR). Compared to conventional DAO MV plan without kV tracking, the OAR dose in the combined MV+kV DAO plan was only slightly higher. DVH curves show that combined MV+kV DAO plan provided about the same PTV coverage as that in the conventional DAO plans without kV imaging. Conclusion: We report a combined MV+kV DAO approach that allows real time kV imager tumor tracking with only a trivial increasing on the OAR doses while providing the same coverage to PTV. The approach is suitable for clinic implementation.

60 APPLIED LIFE SCIENCES↗

Subsurface mechanical damage of fused silica glass during grinding by various sub-aperture tools with and without ultrasonics

The subsurface mechanical damage (SSD) depth after grinding fused silica glass with a comprehensive set of sub-aperture fixed abrasive grinding tools [cup, wheel, belt, pad, and rotary face mill (with and without ultrasonics)] and process parameters has been statistically measured using the taper wedge technique and evaluated. Consistent with a previously reported grinding model [J. Non-Cryst. Solids 352, 5601–5617 (2006) Crossref , Materials Science and Technology of Optical Fabrication (Wiley & Sons, 2018)], based on the sliding indentation fracture by sliding particles or asperities where the normal load per particle determines the depth of the fracture (and ultimately the overall SSD depth), the dominant factor controlling SSD depth was found to be the abrasive size regardless of the tool type and process conditions. Compared to full aperture grinding methods, the overall SSD depth was higher using the sub-aperture tools, likely due to the higher effective pressure and higher load per particle distribution. Here, in addition to abrasive size, a significant reduction in SSD depth was achieved by: (1) reducing the load distribution on the abrasive particles via increase in contact area and/or decrease in mechanical loading; (2) using a more compliant host tool medium; and (3) in what we believe is a more novel way, using ultrasonics. Combining low abrasive size, larger contact area, and a compliant host, the 6 µm diamond in a resin matrix (Trizact) on a foam pad led to very low SSD depth (~ 4.6 µm), relatively fast grinding rate (186 mm 3 /h), and little or no figure degradation. This grinding tool/process is an attractive choice for final grind, resulting in significantly reduced polish out (i.e., “grey out”) times. With the rotary face mill tool, the use of ultrasonics consistently led to a SSD depth reduction (ranging from 17%–34%). A new fracture mechanics-based model, to the best of our knowledge, where the relevant normal load is parallel to the feed direction, has been developed to explain how ultrasonics leads to lower SSD depth. The key factors, supported by finite element stress analysis and load measurements, are (1) the initiation of fractures at higher z heights during the tool’s ultrasonic vertical oscillations, thus propagating less deep into workpiece; (2) reduction in load (and therefore reduction in fracture propagation distance) due to smaller tool-workpiece feed direction contact area (again caused by higher heights relative to depth of cut); (3) upward movement of the tool during oscillation leads to fracturing toward the surface instead into the depth; and finally (4) at tool’s lowest point of oscillation cycle, there may not be enough time for the fracture to propagate to its full length.

Optics and optical instruments↗

Envisat Track 349 and Sentinel-1A Track 64 Interferometric Synthetic Aperture Radar Data of Coso Geothermal Field, California, USA, 2004-2016

This submission contains tarred pair directories for interferometric synthetic aperture radar (InSAR) data covering Coso Geothermal Field in California, USA. Explanation of pair subdirectories: Pairs are formed using the InSAR processing software GMT5SAR (Sandwell et al., 2011). Pair subdirectories are named by starting and ending epochs in YYYYMMDD_YYYYMMDD format. Each tarred pair directory contains GRD files for phase data (radians), unwrapped range change (drhomaskd, in m), and unwrapped range change rate (drange, in m/yr). The data are given in both latitude/longitude and Universal Transverse Mercator (Zone 11N). Raw Synthetic Aperture Radar (SAR) data from the Envisat satellite mission operated by the European Space Agency (ESA) are copyrighted by ESA and were provided through the WInSAR consortium at the UNAVCO facility. Raw Synthetic Aperture Radar (SAR) data from the Sentinel-1A satellite mission operated by ESA were available free of charge through the Distributed Active Archive Center (DAAC) at the Alaska Satellite Facility (ASF) and through the Sentinels Scientific Data Hub. References: Farr, T.G.; Rosen, P.A.; Caro, E.; Crippen, R.; Duren, R.; Hensley, S.; Kobrick, M.; Paller, M.; Rodriguez, E.; Roth, L.; Seal, D.; Shaffer, S.; Shimada, J.; Umland, J.; Werner, M.; Oskin, M.; Burbank, D.; Alsdorf, D. The Shuttle Radar Topography Mission. Reviews of Geophysics 2007, 45, RG2004. doi:10.1029/2005RG000183. Sandwell, D.; Mellors, R.; Tong, X.; Wei, M.; Wessel, P. Open radar interferometry software for mapping surface deformation. Eos, Transactions American Geophysical Union 2011, 92, 234?234. http://dx.doi.org/10.1029/2011EO280002. doi:10.1029/2011EO280002.

15 GEOTHERMAL ENERGY↗

JLEIC electron ring dynamic aperture with non-linear field errors

We present results of dynamic aperture study for the updated electron ring lattice of the Jefferson Lab Electron- Ion Collider (JLEIC). The lattice design features low emittance arcs with local compensation of sextupole nonlinear effects, and low emittance non-linear chromaticity correction sections. Dynamic aperture tracking simulations are performed to evaluate the effects of non-linear field errors, the sensitivity to betatron tune, and the impact of momentum error. Dynamic aperture is also evaluated with the measured PEP-II field errors. Preliminary tolerances to the non-linear field errors in the Final Focus quadrupoles are estimated.

Nosochkov, Yuri↗

Large-Aperture High-Field Nb$_3$Sn Dipole Magnets

Large-aperture high-field dipole magnets based on $Nb_3Sn$ superconductor are necessary for various accelera-tor systems of future hadron and muon colliders. High level of magnetic field and large aperture size lead to large Lorentz forces and mechanical strains and stresses which can damage brittle $Nb_3Sn$ coils. This paper describes conceptual designs of 120-mm aperture dipoles with magnetic fields up to 15 T based on cos-theta coils and a stress man-agement technique.

43 PARTICLE ACCELERATORS↗

Measured dynamic aperture and detuning of nonlinear integrable optics

One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.

43 PARTICLE ACCELERATORS↗

Comments on Momentum Aperture of 100 GeV/n Au Runs in RHIC

In RHIC 2010 100 GeV/n Au run, the momentum aperture has been an issue in the re-bucketing and the beam intensity lifetime in store. Both Blue and Yellow beams with comparable storage RF voltage and peak current have suffered more beam loss than in Run 2007. In this note, some comments are made for the momentum aperture of the lattices used from the Au runs in 2007, 2008 and 2010. From the wigglings and the beam decays of each lattice, information regarding the machine momentum aperture is presented. Several directions in further improvement are discussed.

43 PARTICLE ACCELERATORS↗

Measured Dynamic Aperture and Detuning of Nonlinear Integrable Optics

One of the most promising advantages of nonlinear integrable optics is strong amplitude dependent tune shift without degrading the dynamic aperture. The integrable optics test accelerator (IOTA) at Fermilab is constructed around nonlinear lattice elements of the elliptical type as described by Danilov and Nagaitsev. Detuning and dynamic aperture scans in IOTA were performed using a fast dipole kicker and a low emittance electron beam. The evolution of the dynamic aperture and detuning for different configurations of the integrable optics lattice are presented.

43 PARTICLE ACCELERATORS↗

Development and Test of a Large Aperture $Nb_3Sn$ Cos-Theta Dipole Coil with Stress Management

An innovative stress-management (SM) concept for cos-theta (CT) coils (SMCT coil concept) has been proposed at Fermilab. A large-aperture two-layer Nb3Sn SMCT dipole coil was designed and manufactured to validate and test the SM concept including coil design, fabrication technology, and performance. The first large-aperture SMCT coil (SMCT1) was fabricated and assembled with a small-aperture Nb3Sn coil inside a dipole mirror magnet. SMCT1 coil tests in a dipole mirror structure was performed in two configurations - SMCTM1a with only powered two-layer SMCT1 coil and SMCTM1b with the SMCT coil connected in series with an inner two-layer dipole coil. The test goals are to prove the SMCT coil concept in two-layer and four-layer mirror configurations; demonstrate that the magnet can reach the targeted quench current at the established preload; study magnet training, training memory after thermal cycle, ramp rate and temperature dependences of the magnet quench current; and test the SMCT1 coil quench protection parameters. This paper summarizes the SMCT1 coil design and parameters, the coil main fabrication steps, its assembly in the dipole mirror structure. The results of the SMCTM1a/b mirror test are presented and discussed.

43 PARTICLE ACCELERATORS↗

Analytical Dynamic Aperture Calculation Compared to Tracking Results

In studying dynamic aperture in the storage rings, it is becoming increasing beneficial to understand the growth of the fractal boundary of the dynamic aperture without tracking for millions of turns in a hadron ring. This note describes the J. Gao theory applied to the Electron Ion Collider (EIC) Hadron Storage Ring (HSR) and compares simulation results to theoretical predictions to show that the analytical method may prove useful in quick determinations of improved dynamic aperture based on sextupole and octupole configurations.

43 PARTICLE ACCELERATORS↗