Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “active defects”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Establishing a communications-intensive network to resolve artificial intelligence issues within NASA's Space Station Freedom research centers community

MITRE Corporation's, A Review of Space Station Freedom Program Capabilities for the Development and Application of Advanced Automation, cites as a critical issue the following situation, extant at the NASA facilities visited in the course of preparing the review: The major issues noted with regard to design and research facilities deal with cooperative problem solving, technology transfer, and communication between these facilities. While the authors were visiting lab and test beds to collect information, personnel at many of these facilities were interested in any information they could collect on activities at other facilities. A formal means of gathering this information could not be identified by these personnel. While communication between some facilities was taking place or was planned, for technology transfer or coordination of schedules (e.g., for SADP demonstrations), poor communication between these facilities could lead to a lack of technical standards, duplication of effort, poorly defined interfaces, scheduling problems, and increased cost. Formal mechanisms by which effective communication and cooperative problem solving can take place, and information can be disseminated, must be defined. A solution is proposed for the communications aspects of the issues addressed above; and offered at the same time a solution which can prove effective in dealing with some of the problems being encountered with expertise being lost via retirement or defection to the private sector. The proffered recommendations are recognizably cost-effective and tap the rising sector of expert knowledge being produced by the American academic community.

Howard, E. Davis, III↗

Tack Measurements of Prepreg Tape at Variable Temperature and Humidity

NASA’s Advanced Composites Project has established the goal of achieving a 30 percent reduction in the timeline for certification of primary composite structures for application on commercial aircraft. Prepreg tack is one of several critical parameters affecting composite manufacturing by automated fiber placement (AFP). Tack plays a central role in the prevention of wrinkles and puckers that can occur during AFP, thus knowledge of tack variation arising from a myriad of manufacturing and environmental conditions is imperative for the prediction of defects during AFP. A full design of experiments was performed to experimentally characterize tack on 0.25-inch slit-tape tow IM7/8552-1 prepreg using probe tack testing. Several process parameters (contact force, contact time, retraction speed, and probe diameter) as well as environmental parameters (temperature and humidity) were varied such that the entire parameter space could be efficiently evaluated. Mid-point experimental conditions (i.e., parameters not at either extrema) were included to enable prediction of curvature in relationships and repeat measurements were performed to characterize experimental error. Collectively, these experiments enable determination of primary dependencies as well as multi-parameter relationships. Slit-tape tow samples were mounted to the bottom plate of a rheometer parallel plate fixture using a jig to prevent modification of the active area to be interrogated with the top plate, a polished stainless steel probe, during tack testing. The probe surface was slowly brought into contact with the pre-preg surface until a pre-determined normal force was achieved (2-30 newtons). After a specified dwell time (0.02-10 seconds), during which the probe substrate interaction was maintained under displacement control, the probe was retracted from the surface (0.1-50 millimeters per second). Initial results indicated a clear dependence of tack strength on several parameters, with a particularly strong dependence on temperature and humidity. Although an increase in either of these parameters reduces tack strength, a maximum in tack was predicted to occur under conditions of low temperature and moderate humidity.

Wohl, Christopher↗

Ocular counterrolling measured during eight hours of sustained body tilt

Adaptation of otolith organ activity was investigated by monitoring the ocular counterrolling response of four normal individuals and three persons with severe bilateral loss of labyrinthine function. Several eye photographs were recorded every 30 minutes during a period of 8 hours in which the subject was held in a lateral tilt (60 deg) position. The recorded eye roll position varied to an expected small extent within each test session; this variation about a given mean roll position was similar among the test sessions for all subjects. The mean roll position, on the other hand, changed from session to session in substantial amounts, but these changes appeared to be random with respect to time and among subjects. Furthermore, the intersessional variation in the mean torsional eye position of the normal subjects was equivalent to that of the labyrinthine-defective subjects who displayed little or no counterrolling. These results suggest that the human counterrolling response is maintained either by essentially nonadapting macular receptors or by extremely fine movements of the head in the gravitational field, such as may have been allowed by the biteboard/headrest restraint system used in this study, which served as an everchanging accelerative stimulus.

Miller, E. F., II↗

Solar cycle variation of interplanetary disturbances observed as Doppler scintillation transients

Interplanetary disturbances characterized by plasma that is more turbulence and/or moves faster than the background solar wind are readily defected as transients in Doppler scintillation measurements of the near-Sun solar wind. Systematic analysis of over 23,000 hours of Pioneer Venus Orbiter Doppler measurements obtained inside 0.5 AU during 1979-1987 have made it possible for the first time to investigate the frequency of occurrence of Doppler scintillation transients under solar minimum conditions and to determine its dependence on solar cycle. On the basis of a total of 142 transients, Doppler scintillation transient rates vary from a high of 0.22 in 1979 (one every 4.6 days) to a low of 0.077 transients/d in 1986 (one every 13 days), a decrease by almost a factor of 3 from solar maximum to solar minimum. This solar cycle variation, the strongest yet of any solar wind Doppler scintillation property, is highly correlated with both solar activity characterized by sunspot number and the coronal mass ejection rates deduced from Solswind and Solar Maximum Mission (SMM) coronagraph observations. These results indicate that coronal mass ejections and Doppler scintillation transients are closely related not just during solar maximum, as occasional individual comparisons have shown in the past, but throughout the entire solar cycle, and strengthen the notation that the Doppler scintillation and optical transients are different manifestations of the same physical phenomenon. The magnitudes of the transients, as described by the ratio of peak to pretransient scintillation levels (EF for enhancement factor), and their distribution iwth heliocentric distance also vary with solar cycle. While EF tends to diminish with increasing heliocentric distance during high solar activity, it is more evenly distributed during low solar activity. EF is also lower during solar minimum, as 13% of the transients during solar maximum have values exceeding 23, the highest EF observed during solar minimum. These results are consistent with the fact that occasional major fast-moving interplanetary shocks that are observed during solar maximum are very rate during solar minimum.

Woo, Richard↗

Omics Research on the International Space Station

The International Space Station (ISS) is an orbiting laboratory whose goals include advancing science and technology research. Completion of ISS assembly ushered a new era focused on utilization, encompassing multiple disciplines such as Biology and Biotechnology, Physical Sciences, Technology Development and Demonstration, Human Research, Earth and Space Sciences, and Educational Activities. The research complement planned for upcoming ISS Expeditions 45&46 includes several investigations in the new field of omics, which aims to collectively characterize sets of biomolecules (e.g., genomic, epigenomic, transcriptomic, proteomic, and metabolomic products) that translate into organismic structure and function. For example, Multi‐Omics is a JAXA investigation that analyzes human microbial metabolic cross‐talk in the space ecosystem by evaluating data from immune dysregulation biomarkers, metabolic profiles, and microbiota composition. The NASA OsteoOmics investigation studies gravitational regulation of osteoblast genomics and metabolism. Tissue Regeneration uses pan‐omics approaches with cells cultured in bioreactors to characterize factors involved in mammalian bone tissue regeneration in microgravity. Rodent Research‐3 includes an experiment that implements pan‐omics to evaluate therapeutically significant molecular circuits, markers, and biomaterials associated with microgravity wound healing and tissue regeneration in bone defective rodents. The JAXA Mouse Epigenetics investigation examines molecular alterations in organ specific gene expression patterns and epigenetic modifications, and analyzes murine germ cell development during long term spaceflight. Lastly, Twins Study ("Differential effects of homozygous twin astronauts associated with differences in exposure to spaceflight factors"), NASA's first foray into human omics research, applies integrated analyses to assess biomolecular responses to physical, physiological, and environmental stressors associated with spaceflight.

Love, John↗

Effect of convection on osteoblastic cell growth and function in biodegradable polymer foam scaffolds

Culture of seeded osteoblastic cells in three-dimensional osteoconductive scaffolds in vitro is a promising approach to produce an osteoinductive material for repair of bone defects. However, culture of cells in scaffolds sufficiently large to bridge critical-sized defects is a challenge for tissue engineers. Diffusion may not be sufficient to supply nutrients into large scaffolds and consequently cells may grow preferentially at the periphery under static culture conditions. Three alternative culturing schemes that convect media were considered: a spinner flask, a rotary vessel, and a perfusion flow system. Poly(DL-lactic-co-glycolic acid) (PLGA) foam discs (12.7 mm diameter, 6.0 mm thick, 78.8% porous) were seeded with osteoblastic marrow stromal cells and cultured in the presence of dexamethasone and L-ascorbic acid for 7 and 14 days. Cell numbers per foam were found to be similar with all culturing schemes indicating that cell growth could not be enhanced by convection, but histological analysis indicated that the rotary vessel and flow system produced a more uniform distribution of cells throughout the foams. Alkaline phosphatase (ALP) activity per cell was higher with culture in the flow system and spinner flask after 7 days, while no differences in osteocalcin (OC) activity per cell were observed among culturing methods after 14 days in culture. Based on the higher ALP activity and better cell uniformity throughout the cultured foams, the flow system appears to be the superior culturing method, although equally important is the fact that in none of the tests did any of the alternative culturing techniques underperform the static controls. Thus, this study demonstrates that culturing techniques that utilize fluid flow, and in particular the flow perfusion system, improve the properties of the seeded cells over those maintained in static culture.

NASA Discipline Cell Biology↗

NASA GPM Status and Future Activities

The joint U.S.-Japan Global Precipitation Measurement (GPM) mission is approaching a decade of operations, and continues to pursue research, dataset production, and outreach related to precipitation. Key activities over the last year were the release of an improved “Version 07” of all GPM precipitation and latent heating products, boosting the orbit of the GPM Core Observatory (GPM CO) to 435 km, and improving quality control on precipitation retrievals from the GPM constellation of passive microwave satellites. This presentation summarizes key improvements to the GPM products and provides some examples of the changes between Versions 06 and 07 in algorithm performance. One important operational change that affected Version 07 is that the scanning strategy for the Ka-band radar channel changed in May 2018; all products that depend on Ka were revised to accommodate this change. For example, in Version 07 the Goddard Profiling (GPROF) algorithm has implemented improvements in regions where orographic enhancement and suppression take place and where the surface is snowy/icy, and again covers radiometers reaching back to 1987. The Combined Radar Radiometer Algorithm (CORRA) now incorporates modified drop-size distribution constraints that substantially reduce bias. Revisions to the Convective-Stratiform Heating (CSH) algorithm employ new radiative transfer retrievals as well as accounting for terrain in the vertical coordinates. Each algorithm was adjusted to ensure continuity for each product across the boundary in 2014 between the predecessor Tropical Rainfall Measuring Mission (TRMM) and the GPM CO. The U.S. Science Team’s Integrated Multi-satellitE Retrievals for GPM (IMERG) was upgraded to account for distortions in the probability density function of regional precipitation rates due to weighted averaging in the Kalman filter used for “morphing” the passive microwave data. Maintaining the GPM CO orbital altitude in the the current very active solar cycle has been forcing the use of more fuel than planned and consequently shortening the forecasted life of the mission from the early 2030's to the late 2020's. It was considered vital to regain some of this lifetime to ensure overlap with the upcoming Atmosphere Observing System mission to provide crosscalibration of instruments. To accomplish this, the orbital altitude was raised from 400 to 435 km on 7-8 November 2023. Thereafter, the primary GPM CO algorithms had to be revised to account for the change in observing parameters. By meeting time this action should be complete. Recently, a screening algorithm based on auto-encoding was developed that uncovered 162 orbits (out of the many thousands of orbits across all years and all satellites) of passive microwave retrievals that had highly anomalous values. Removing these defective retrievals has improved the integrity of both the GPROF and IMERG records. However, the nature of the IMERG processing interacted sufficiently badly with the now-discovered anomalous orbits that it was necessary to completely reprocess the IMERG Final Run record, now labeled Version 07B. The presentation also considers major issues that require continued attention, including the use of machine learning algorithms and the operational challenge of swarms of “small”, perhaps short-lived satellites.

GPM↗

Study of natural convection and interface shape in directional solidification of succinonitrile

Flow visualization experiments in a Bridgman furnace at zero growth velocity have been performed. The experiments were intended to investigate if the photochromic dye activation method could be used in a crystal growth study. The results from this work have confirmed that with a carefully designed experimental setup, the photochromic-dye method permits qualitative and quantitative evaluation of the flow field near the interface in crystal growth experiments. For the horizontal orientation of a 6 mm x 6 mm ampoule and an axial temperature gradient of 26.5 C/cm, velocity profiles have been obtained accurately at various positions near the interface. The maximum velocity of 1.29 mm/sec was measured in the central vertical plane and the flow was symmetrical about that plane. A flow inversion point was also noted, above which the flow was towards the interface and below it, away from the interface. The results obtained are useful for validating 3-dimensional numerical models and establishing a link between the macroscopic processing conditions and the formation of crystalline defects.

Kawaji, M.↗

Development of high resolution imaging detectors for x ray astronomy

This final report summarizes our past activities and discusses the work performed over the period of 1 April 1990 through 1 April 1991 on x-ray optics, soft x-ray (0.1 - 10 KeV) imaging detectors, and hard x-ray (10 - 300 KeV) imaging detectors. If microchannel plates (MCPs) can be used to focus x-rays with a high efficiency and good angular resolution, they will revolutionize the field of x-ray optics. An x-ray image of a point source through an array of square MCP pores compared favorably with our ray tracing model for the MCP. Initial analysis of this image demonstrates the feasibility of MCPs for soft x-rays. Our work continues with optimizing the performance of our soft x-ray MCP imaging detectors. This work involves readout technology that should provide improved MCP readout devices (thin film crossed grid, curved, and resistive sheets), defect removal in MCPs, and photocathode optimization. In the area of hard x-ray detector development we have developed two different techniques for producing a CsI photocathode thickness of 10 to 100 microns, such that it is thick enough to absorb the high energy x-rays and still allow the photoelectrons to escape to the top MCP of a modified soft x-ray imaging detector. The methods involve vacuum depositing a thick film of CsI on a strong back, and producing a converter device that takes the place of the photocathode.

Murray, S. S.↗

Performance, defect behavior and carrier enhancement in low energy, proton irradiated p+nn+ InP solar cells

The highest AMO efficiency (19.1 percent) InP solar cell consisted of an n+pp+ structure epitaxially grown on a p+ InP substrate. However, the high cost and relative fragility of InP served as motivation for research efforts directed at heteroepitaxial growth of InP on more viable substrates. The highest AMO efficiency (13.7 percent) for this type of cell was achieved using a GaAs substrate. Considering only cost and fracture toughness, Si would be the preferred substrate. The fact that Si is a donor in InP introduces complexities which are necessary in order to avoid the formation of an efficiency limiting counterdiode. One method used to overcome this problem lies in employing an n+p+ tunnel junction in contact with the cell's p region. A simpler method consists of using an n+ substrate and processing the cell in the p+ nn+ configuration. This eliminates the need for a tunnel junction. Unfortunately, the p/n configuration has received relatively little attention the best cell with this geometry having achieved an efficiency of 17 percent. Irradiation of these homoepitaxial cells, with 1 Mev electrons, showed that they were slightly more radiation resistant than diffused junction n/p cells. Additional p/n InP cells have been processed by some activity aimed at diffusion. Currently, there has been some activity aimed at producing heteroepitaxial p+nn+ InP cells using n+ Ge substrates. Since, like Si, Ge is an n-dopant in InP, use of this configuration obviates the need for a tunnel junction. Obviously, before attempting to process heteroepitaxial cells, one must produce a reasonably good homoepitaxial cell. In the present case we focus our attention on homoepitaxially on an n+ Ge substrate.

Weinberg, I.↗

Stress-Activated Electric Currents in Icy Planetary Bodies: H2O2-Doped H2O Ices

Planetary satellites such as the Jovian moon Europa and several Kuiper Belt objects (including Pluto) have surfaces consisting largely of H2O ice, which is brittle and behaves as a rock at the low temperatures that prevail in the outer Solar System. Several of those ice-crusted bodies show evidence of tectonic activity indicating high levels of stress. This paper reports on laboratory experiments with pure H2O ice and H2O2–doped H2O ices with H2O2 concentration levels comparable to those in the ices of Europa. Elongated rectangular ice blocks at T = −81 °C [192 K] were stressed at one end to test whether electric currents are generated and capable of flowing down the stress gradient. Pure H2O ice was found to not produce currents above the 10−10 A background level except for occasional transients in the 10−9–10−8 A range during fracture or rapid plastic deformation due to electrons, e’. By contrast, stressing H2O2-doped H2O ices consistently produced electric currents in the 10−7–10−5 A range, due to holes, h•, propagating from the stressed end to the unstressed end. The h• charge carriers are generated by the break-up of peroxy bonds of H2O2 molecules, leading to O−, equivalent to defect electrons or holes h• in the O2− matrix.

Water ice↗

Development program for 1.93-micron lasers

For the first time lasers operating at 1.93 microns were demonstrated. The lasers were fabricated by Vapor Phase Epitaxial (VPE) growth techniques currently used for the fabrication of high power lasers at 1.3 microns. The structure of these laser diodes consisted of compositionally graded, sulfur-doped InAsP, grown on an InP substrate; a constant-composition n+InAs(0.27)P(0.73) layer, which is the first cladding layer; an In(0.66)Ga(0.34)As layer, which is the active region, and a second InAs(0.27)P(0.73) layer. The devices were oxide-stripe DH lasers (gain-guided only). The best devices had 80 K lasing thresholds in the range of from 80 to 150 mA, and T sub o (below 220 K) in the range of 60 to 90 K. The highest observed temperature of oscillation was 15.5 C. The highest observed power output at 80 K was in the range of 3 to 5 mW. The calculated delta I/delta T was 4.4 A/K. As a part of the materials development, PIN homojunction detectors having the band edge near 1.93 were also fabricated. The best devices (100 micron diameter, mesa structure) exhibited room temperature dark currents in the range of from 20 to 50 nA and had QE at 1.93 microns in the range of 35 to 40 percent. In addition to the device results, the InGaAs-InAsP materials system was extensively investigated and low defect density layers can now be grown allowing for significant device performance improvement.

Longeway, P.↗

BioSentinel ISS mission: Analysis of ISS Flight Data and Lessons Learned

As we prepare for a future with a human presence on the Moon, Mars, and beyond, the need for countermeasures to protect astronauts against deep space radiation is ever pressing. However, our understanding of how life operates in the space environment, especially past the protection of the Van Allen radiation belts, is critically limited. BioSentinel, a biological CubeSat, aims to further investigate the effects of deep space ionizing radiation, utilizing the budding yeast Saccharomyces cerevisiae to examine the cell’s DNA damage response. The yeast wild type and a rad51Δ mutant strain defective for DNA damage repair will be monitored via the redox dye alamarBlue and a 3-color LED detection system. Selected as a secondary payload on Artemis I, BioSentinel will be the first deep space biological experiment in a half-century and the first biological CubeSat or free-flyer to ever reach a heliocentric orbit. Notably, BioSentinel is the only biological CubeSat to include an ISS control study in addition to a ground control. Comparisons between the ground, ISS, and free-flyer experiments will allow us to isolate the effects of deep space radiation from those of microgravity. The ISS study also provides a unique platform to conduct important technological and biological testing of BioSentinel’s instrumentation in preparation for the deep space mission. In this work, we use a series of data processing tools and scripts to analyze ISS flight data as well as samples exposed to simulated space radiation at Brookhaven National Laboratory, specifically looking at cell growth, metabolic activity, and duplication rates based on optical absorbance and alamarBlue kinetics. These analyses provide a crucial set of controls and a framework for analyzing and interpreting future data sets from the free-flyer, helping us gain further insight into the health risks astronauts will face when exposed to deep space radiation.

Kylie Lauren Lo-Wen Akiyama↗

The Application of Infrared Thermographic Inspection Techniques to the Space Shuttle Thermal Protection System

The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the "good" material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued where a fixed set of eigenvectors, generated from an analytic model of the thermal response of the material under examination, is used to process the thermal data from the RCC materials. Details of a one-dimensional analytic model and a two-dimensional finite-element model will be presented. An overview of the PCA process as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens will be shown. Finally, a number of different applications of this technology to various RCC components will be presented.

Cramer, K. E.↗

The Application of Principal Component Analysis Using Fixed Eigenvectors to the Infrared Thermographic Inspection of the Space Shuttle Thermal Protection System

The Nondestructive Evaluation Sciences Branch at NASA s Langley Research Center has been actively involved in the development of thermographic inspection techniques for more than 15 years. Since the Space Shuttle Columbia accident, NASA has focused on the improvement of advanced NDE techniques for the Reinforced Carbon-Carbon (RCC) panels that comprise the orbiter s wing leading edge. Various nondestructive inspection techniques have been used in the examination of the RCC, but thermography has emerged as an effective inspection alternative to more traditional methods. Thermography is a non-contact inspection method as compared to ultrasonic techniques which typically require the use of a coupling medium between the transducer and material. Like radiographic techniques, thermography can be used to inspect large areas, but has the advantage of minimal safety concerns and the ability for single-sided measurements. Principal Component Analysis (PCA) has been shown effective for reducing thermographic NDE data. A typical implementation of PCA is when the eigenvectors are generated from the data set being analyzed. Although it is a powerful tool for enhancing the visibility of defects in thermal data, PCA can be computationally intense and time consuming when applied to the large data sets typical in thermography. Additionally, PCA can experience problems when very large defects are present (defects that dominate the field-of-view), since the calculation of the eigenvectors is now governed by the presence of the defect, not the good material. To increase the processing speed and to minimize the negative effects of large defects, an alternative method of PCA is being pursued when a fixed set of eigenvectors is used to process the thermal data from the RCC materials. These eigen vectors can be generated either from an analytic model of the thermal response of the material under examination, or from a large cross section of experimental data. This paper will provide the details of the analytic model; an overview of the PCA process; as well as a quantitative signal-to-noise comparison of the results of performing both embodiments of PCA on thermographic data from various RCC specimens. Details of a system that has been developed to allow insitu inspection of a majority of shuttle RCC components will be presented along with the acceptance test results for this system. Additionally, the results of applying this technology to the Space Shuttle Discovery after its return from flight will be presented.

Cramer, K. Elliott↗

Chip-on-Board Technology 1996 Year-end Report (Design, Manufacturing, and Reliability Study)

The major impetus for flight qualifying Chip-On-Board (COB) packaging technology is the shift in emphasis for space missions to smaller, better, and cheaper spacecraft and satellites resulting from the NASA New Millenium initiative and similar requirements in DoD-sponsored programs. The most important benefit that can potentially be derived from miniaturizing spacecraft and satellites is the significant cost saving realizable if a smaller launch vehicle may be employed. Besides the program cost saving, there are several other advantages to building COB-based space hardware. First, once a well-controlled process is established, COB can be low cost compared to standard Multi-Chip Module (MCM) technology. This cost competitiveness is regarded as a result of the generally greater availability and lower cost of Known Good Die (KGD). Coupled with the elimination of the first level of packaging (chip package), compact, high-density circuit boards can be realized with Printed Wiring Boards (PWB) that can now be made with ever-decreasing feature size in line width and via hole. Since the COB packaging technique in this study is based mainly on populating bare dice on a suitable multi-layer laminate substrate which is not hermetically sealed, die coating for protection from the environment is required. In recent years, significant improvements have been made in die coating materials which further enhance the appeal of COB. Hysol epoxies, silicone, parylene and silicon nitride are desirable because of their compatible Thermal Coefficient of Expansion (TCE) and good moisture resistant capability. These die coating materials have all been used in the space and other industries with varying degrees of success. COB technology, specifically siliconnitride coated hardware, has been flown by Lockheed on the Polar satellite. In addition, DARPA has invested a substantial amount of resources on MCM and COB-related activities recently. With COB on the verge of becoming a dominant player in DoD programs, DARPA is increasing its support of the availability of KGDs which will help decrease their cost. Aside from the various major developments and trends in the space and defense industries that are favorable to the acceptance and widespread use of'COB packaging technology, implementing COB can be appealing in other aspects. Since the interconnection interface is usually the weak link in a system, the overall circuit or system reliability may actually be improved because of the elimination of a level of interconnect/packaging at the chip. With COB, mixing packaging technologies is possible. Because some devices are only available in commercial plastic packages, populating a multi-layer laminate substrate with both bare dice and plastic-package parts is inevitable. Another attractive feature of COB is that re-workability is possible if die coating is applied only on the die top. This method allows local replacement of individual dice that were found to be defective instead of replacing an entire board. In terms of thermal management, unpackaged devices offer a shorter thermal resistance path than their packaged counterparts thereby improving thermal sinking and heat removal from the parts.

Le, Binh Q.↗

Alteration of mineral crystallinity and collagen cross-linking of bones in osteopetrotic toothless (tl/tl) rats and their improvement after treatment with colony stimulating factor-1

A common feature of various types of mammalian osteopetroses is a marked increase in bone mass accompanied by spontaneous bone fractures. The toothless (tl/tl) rat osteopetrotic mutation is characterized by drastically reduced bone resorption due to a profound deficiency of osteoclasts and their precursors. An altered bone morphology has also been observed. The mutants cannot be cured by bone marrow transplantation, but skeletal defects are greatly reduced after treatment with colony stimulating factor 1 (CSF-1). The objectives of this study were to characterize mineral and collagen matrices in cancellous and compact bone isolated from long bones of 6-week-old normal littermates, tl/tl osteopetrotic mutants and mutants (tl/tl) treated with CSF-1. There were no differences in bone mineral content, but a significant decrease in the crystallinity of mineral evaluated by the method based on electron paramagnetic resonance spectrometry was observed in all bones of tl/tl mutants as compared to that of controls. Within the collagen matrix, slight decreases in the labile cross-links, but significant increases in the content of the stable cross-links, pyridinoline, and deoxypyridinoline, were observed in both cancellous and compact bone of osteopetrotic mutants. In tl/tl mutants treated with human recombinant CSF-1, the normalization of the crystallinity of bone mineral as well as collagen cross-links was found. Our results indicate that remodeling of bone matrix in tl/tl mutants is highly suppressed, but that after treatment with CSF-1, this activity recovers significantly. Taken together, these data provide further support for the hypothesis that CSF-1 is an essential factor for normal osteoclast differentiation and bone remodelling.

NASA Discipline Musculoskeletal↗

Composite Thermal Switch

Lithium primary and lithium ion secondary batteries provide high specific energy and energy density. The use of these batteries also helps to reduce launch weight. Both primary and secondary cells can be packaged as high-rate cells, which can present a threat to crew and equipment in the event of external or internal short circuits. Overheating of the cell interior from high current flows induced by short circuits can result in exothermic reactions in lithium primary cells and fully charged lithium ion secondary cells. Venting of the cell case, ejection of cell components, and fire have been reported in both types of cells, resulting from abuse, cell imperfections, or faulty electronic control design. A switch has been developed that consists of a thin layer of composite material made from nanoscale particles of nickel and Teflon that conducts electrons at room temperature and switches to an insulator at an elevated temperature, thus interrupting current flow to prevent thermal runaway caused by internal short circuits. The material is placed within the cell, as a thin layer incorporated within the anode and/or the cathode, to control excess currents from metal-to-metal or metal-to-carbon shorts that might result from cell crush or a manufacturing defect. The safety of high-rate cells is thus improved, preventing serious injury to personnel and sensitive equipment located near the battery. The use of recently available nanoscale particles of nickel and Teflon permits an improved, homogeneous material with the potential to be fine-tuned to a unique switch temperature, sufficiently below the onset of a catastrophic chemical reaction. The smaller particles also permit the formation of a thinner control film layer (<50 m), which can be incorporated into commercial high-rate lithium primary and secondary cells. The innovation permits incorporation in current lithium and lithium-ion cell designs with a minimal impact on cell weight and volume. The composite thermal switch (CTS(TradeMark)) coating can be incorporated in either the anode or cathode or both. The coating can be applied in a variety of different processes that permits incorporation in the cell and electrode manufacturing processes. The CTS responds quickly and halts current flow in the hottest parts of the cell first. The coating can be applied to metal foil and supplied as a cell component onto which the active electrode materials are coated.

McDonald, Robert↗