Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “acoustic emissions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Forward Skirt Structural Testing on the Space Launch System (SLS) Program

Structural testing was performed to evaluate heritage forward skirts from the Space Shuttle program for use on the Space Launch System (SLS) program. One forward skirt is located in each solid rocket booster. Heritage forward skirts are aluminum 2219 welded structures. Loads are applied at the forward skirt thrust post and ball assembly. Testing was needed because SLS ascent loads are roughly 40% higher than Space Shuttle loads. Testing objectives were to determine margins of safety, demonstrate reliability, and validate analytical models. Two forward skirts were structurally tested using the test configuration. The test stand applied loads to the thrust post. Four hydraulic actuators were used to apply axial load and two hydraulic actuators were used to apply radial and tangential loads. The first test was referred to as FSTA-1 (Forward Skirt Structural Test Article) and was performed in April/May 2014. The purpose of FSTA-1 was to verify the ultimate capability of the forward skirt subjected to ascent ultimate loads. Testing consisted of two liftoff load cases taken to 100% limit load followed by an ascent load case taken to 110% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The second test was referred to as FSTA-2 and performed in July/August of 2014. The purpose of FSTA-2 was to verify the ultimate capability of the forward skirt subjected to liftoff ultimate loads. Testing consisted of six liftoff load cases taken to 100% limit load followed by the six liftoff cases taken to 140% limit load. Two ascent load cases were then tested to 100% limit load. The forward skirt was unloaded to no load after each test case. Lastly, the forward skirt was tested to 140% limit and then to failure using the ascent loads. The forward skirts on FSTA-1 and FSTA-2 successfully carried all applied liftoff and ascent load cases. Both FSTA-1 and FSTA-2 were tested to failure by increasing the ascent loads. Failure occurred in the forward skirt thrust post radius. The forward skirts on FSTA-1 and FSTA-2 had nearly identical failure modes. FSTA-1 failed at 1.72 times limit load and FSTA-2 failed at 1.62 times limit load. This difference is primarily attributed to variation in material properties in the thrust post region. Test data were obtained from strain gages, deflection gages, ARAMIS digital strain measurement, acoustic emissions, and high-speed video. Strain gage data and ARAMIS strain were compared to finite element (FE) analysis predictions. Both the forward skirt and tooling were modeled. This allows the analysis to simulate the loading as close as possible to actual test configuration. FSTA-1 and FSTA-2 were instrumented with over 200 strain gages to ensure all possible failure modes could be captured. However, it turned out that three gages provided critical strain data. One was located in the post bore and two on the post radius. More gages were not specified due to space limitations and the desire to not interfere with the use of the ARAMIS system on the post radius. Measured strains were compared to analysis results for the load cycle to failure. Note that FSTA-1 gages were lost before failure was reached. FSTA-2 gages made it to the failure load but one of the radius gages was lost before testing began. This gage was not replaced because of the time and cost associated with disassembly of the test structure. Correlation to analysis was excellent for FSTA-1. FSTA-2 was not quite as good because there was more residual strain from previous load cycles. FSTA-2 was loaded and unloaded with 12 liftoff cases and two ascent cases before taking the skirt to failure. FSTA-1 only had two liftoff cases and one ascent case before taking the skirt to failure. The ARAMIS system was used to determine strain at the post radius by processing digital images of a speckled paint pattern. Digital cameras recorded images of the speckled paint pattern. ARAMIS strain results for FSTA-2 just prior to failure. Note a high strain location develops near the left side. This high strain compares well to analysis prediction for both FSTA-1 and FSTA-2. The strain at this location was also plotted versus limit load. Both FSTA-1 and FSTA-2 had excellent correlation between ARAMIS and analysis strains. Acoustic emission (AE) sensors were used to monitor for damage formation that may occur during testing (e.g., crack formation and growth or propagation). AE was very important because after disassembly of FSTA-1, a crack was observed in the ball fitting radius. The ball fitting did not crack on FSTA-2. AE data was used to reconstruct when the crack occurred. The AE energy versus time plot for FSTA. The energy increased considerably at 850 seconds (152% limit load), indicating a crack could have formed at this point. The only visual evidence found that could have corresponded to this was the crack that initiated in the ball fitting. The cracks in the forward skirt aluminum structures would likely have been lower energy due to a lower modulus and all that were found after failure correlated to occurring after the initial crack in the post radius. This was verified by high-speed cameras used to record the failure.

Lohrer, J. D.↗

Laboratory investigation of hydraulic fracturing in granitic rocks using active and passive seismic monitoring

SUMMARY Knowledge of the fracturing processes can be important for the optimization of pressurized fluid injection operations in the deep underground rock mass. Active and passive seismic monitoring techniques have been used in the field for tracking or mapping the propagating hydraulic fracture. Although both these monitoring techniques provide valuable information about the generated fracture network, it is difficult for either technique to comprehensibly identify the different processes associated with hydraulic fracturing. The combined active and passive monitoring has the potential for better characterization of the complex hydraulic fracturing phenomena. In this study, laboratory hydraulic fracturing experiments with combined active and passive seismic monitoring were conducted on true triaxially loaded Barre granite cubes with different fluid injection rates. The seismic inelastic fracturing was detected by 16 passive acoustic emission sensors, where 3678 and 2370 seismic source events were detected for the high and low injection rate experiments, respectively. For active monitoring, strong variations in the attributes of signals were observed which were transmitted through four source–receiver pairs, placed both perpendicular and parallel to the generated hydraulic fracture. Positive velocity changes were observed for active sensor pairs with ray paths passing through the generated hydraulic fracture indicating fluid permeation, whereas isolated dry deformation was characterized by a slight but permanent velocity decrease. Compared to velocity, the energy of the active signals was 1–2 orders of magnitude more sensitive to different hydraulic fracturing processes. However, the sensitivity and signatures of the active signal attributes were found to be dependent on the frequency range and direction of ray path with respect to the location of the generated fracture network. Using the coupled evaluation of the active and passive signals we were able to systematically identify various hydraulic fracturing processes including: (1) aseismic deformation, (2) fracture initiation and fluid permeation, (3) pressure build-up, (4) fracture propagation and (5) pressure release and leak-off. The results of this study showed that combining the respective advantages of active and passive seismic techniques and using both of them to monitor the failure processes can facilitate a more comprehensive understanding and better control of the hydraulic stimulations in subsurface operations.

Geochemistry & Geophysics↗

A Neural Network/Acoustic Emission Analysis of Impact Damaged Graphite/Epoxy Pressure Vessels

Acoustic emission (AE) signal analysis has been used to measure the effects of impact damage on burst pressure in 5.75 inch diameter, inert propellant filled, filament wound pressure vessels. The AE data were collected from fifteen graphite/epoxy pressure vessels featuring five damage states and three resin systems. A burst pressure prediction model was developed by correlating the AE amplitude (frequency) distribution, generated during the first pressure ramp to 800 psig (approximately 25% of the average expected burst pressure for an undamaged vessel) to known burst pressures using a four layered back propagation neural network. The neural network, trained on three vessels from each resin system, was able to predict burst pressures with a worst case error of 5.7% for the entire fifteen bottle set.

Walker, James L.↗

NASA Applications of Structural Health Monitoring Technology

This presentation provides examples of research and development that has recently or is currently being conducted at NASA, with a special emphasis on the application of structural health monitoring (SHM) of aerospace vehicles. SHM applications on several vehicle programs are highlighted, including Space Shuttle Orbiter, International Space Station, Uninhabited Aerial Vehicles, and Expandable Launch Vehicles. Examples of current and previous work are presented in the following categories: acoustic emission impact detection, multi-parameter fiber optic strain-based sensing, wireless sensor system development, and distributed leak detection.

fiber optic sensors↗

NASA Applications of Structural Health Monitoring Technology

This presentation provides examples of research and development that has recently or is currently being conducted at NASA, with a special emphasis on the application of structural health monitoring (SHM) of aerospace vehicles. SHM applications on several vehicle programs are highlighted, including Space Shuttle Orbiter, the International Space Station, Uninhabited Aerial Vehicles, and Expendable Launch Vehicles. Examples of current and previous work are presented in the following categories: acoustic emission impact detection, multi-parameter fiber optic strain-based sensing, wireless sensor system development, and distributed leak detection.

Fiber Optic Sensors↗

Evaluation of CVI SiC/SiC Composites for High Temperature Applications

Silicon carbide fiber reinforced silicon carbide (SiC/SiC) composites are candidate materials for various high temperature turbine engine applications because of their high specific strength and good creep resistance at temperatures of 1400 C (2552 F) and higher. Chemical vapor infiltration (CVI) SiC/SiC ceramic matrix composites (CMC) incorporating Sylramic-iBN SiC fiber were evaluated via fast fracture tensile tests (acoustic emission damage characterization to assess cracking behavior), tensile creep testing, and microscopy. The results of this testing and observed material behavior degradation mechanisms are reviewed.

testing↗

Directional Cooling-Induced Fracturing Westerly Granite Test Results

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on a short, cylindrical sample of Westerly granite (diameter = 4 inches, height ~ 2 inches). Liquid nitrogen was poured in a copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. Included in this submission is an animation of the AEs, a graphic displaying the temperature changes, and the measured data.

15 GEOTHERMAL ENERGY↗

Laboratory Evaluation of the Thermal Breakout Method for Maximum Horizontal Stress Measurement

Measuring in situ stress is essential for many problems in geomechanics, and the maximum horizontal stress is the most difficult to constrain. We are developing an extension of the breakout method to measure maximum horizontal stress in regions where natural breakouts do not occur. In the novel thermal breakout method, additional compression which leads to breakout development is induced by heating the borehole wall. In the present study, we validated the method experimentally in a true-triaxial apparatus on samples with predrilled boreholes. Two rocks were selected for laboratory testing: high-porosity Berea sandstone and low-porosity Niagaran dolomite. Prior to main true-triaxial tests, we carried out standard testing to characterize the strength, elasticity and thermal properties. The true-triaxial experiments consisted of: (1) room-temperature tests where samples were first loaded mechanically until the breakout formed, and (2) elevated-temperature tests where samples were loaded mechanically within the elastic range with additional compression induced thermally. Breakout initiation was monitored by acoustic emission sensors mounted on the pistons that applied horizontal stresses. Furthermore, the magnitude of induced thermal stress was calculated from temperature measurements around the borehole wall. In both rock types, we created thermally induced breakouts and examined analytical expressions to constrain maximum horizontal stress based on strength, elastic and thermal properties of the rocks.

58 GEOSCIENCES↗

SiC Fibers and SiCf/SiC Ceramic Matrix Minicomposites Damage Behavior

Silicon Carbide based Ceramic Matrix Composites (CMCs) are attractive materials for use in high-temperature applications in the aerospace industry. Performance and durability of CMCs depend on the properties of its constituents such as fibers and matrix. Therefore, CMCs constituents limitations and damage mechanisms are discussed and characterized in representative simulated application conditions and dominant damage mechanisms are identified at elevated temperatures. In this work, the initiation and evolution of damage in Hi-Nicalon type S fiber-reinforced minicomposites with different interphases thicknesses from different manufacturers were investigated employing several nondestructive evaluation techniques such as acoustic emission, electrical resistance and microscopy. Moreover, the tensile creep behavior of single Hi-Nicalon Type S SiC fibers were tested and characterized and creep parameters were extracted. Fibers creep tests were performed in air or vacuum at 1200-1482 C under high stresses. Creep parameters was then used in understanding load sharing and lifing of ceramic matrix minicomposites. Future work plans will be reviewed.

SiC fibers↗

Localization of deformation in fluid-saturated sandstone

Herein we discuss a laboratory study of inelastic deformation and localization was conducted to evaluate microseismicity and fracture in fluid-saturated rock. Plane strain compression experiments were performed on oil- and water-saturated Berea sandstone under dry, drained, undrained, and quasi-unjacketed conditions. Parameters associated with the elastic and inelastic material response were accurately measured and used in a constitutive model to predict localization of deformation under the drained and undrained conditions. Acoustic emission (AE) activity was recorded and the onset of inelastic response in fluid-saturated rock, similar to dry rock, coincided with an increase in AE rate. Fracture initiation and propagation were successfully monitored by AE locations. Clustering of AE events and the start of inhomogeneous deformation inferred from displacement measurements are shown to be well correlated with the model prediction of the onset of localized deformation under various rock-fluid interaction conditions.

42 ENGINEERING↗

Operating Conditions of a Main Bearing Contact in a Commercial Wind Turbine

This presentation described acoustic emissions and temperature characteristics of a commercial main bearing in a wind turbine drivetrain. These characteristics were measured on the outer ring of the bearing by SKF DVST nodes, which are mounted on both upwind and downwind rows of the main bearing at four equally spaced circumferential locations. The measurement started in early 2018 and ends in 2020 and five-month data in 2018 winter was analyzed in this study.

acoustic emission↗

Development and Characterization of Lightweight Durable Composite Conductor for Cables

Sustainable aviation in the form of electrified propulsion is likely to lead to an increase in the electrical assets contained within a single aircraft. As a result, it is desirable to design light weight conductor materials, thus reducing the payload of components like motor windings, low voltage signal cables, and transmission cables for data and power. One approach involves replacing pure Cu wiring with metalized CNT composites. This paper evaluates a framework for modeling overall conductivity and current sharing within such composites. Processing methods and parameters were refined. Select electroplated samples outperformed pure Cu in conductivity and had comparable ultimate tensile strengths. Tensile strengths are expected to improve with an additional densification step during processing. Acoustic emission data was used to predict the failure mechanism of the composite. Theories explaining improved intrinsic conductivity are discussed, with a focus on chemical and mechanical interactions at the Cu-CNT interface. These include Cu infiltration of CNT crevices, CNT oxidation, activity at defects in CNT walls, and the release of carbide-forming metals from CNT walls. Validating any or all these theories will require further work replicating data, collecting electron micrographs and conducting chemical analyses.

Metalized CNT↗

High-Cycle Fatigue Behavior of SiC-based Ceramic Matrix Composites (CMCs) at High Temperatures

High-cycle fatigue (HCF) behavior of a melt-infiltrated, pre-preg SiC/SiC ceramic matrix composite (CMC) was investigated using dogbone tensile specimens without and with simulated cooling holes at 1500 and 2400 °F. The CMC material used for this study was fabricated by GE Aviation and had a ply configuration of [0/90/0]3. HCF tests were conducted with an R-ratio of 0.6 and a cyclic frequency of 30 Hz. Runout in HCF was defined as 30 million cycles. Monotonic tensile tests were conducted at room temperature (RT) on as-received CMC specimens and on runout HCF specimens to determine residual tensile strengths. Digital image correlation (DIC) and acoustic emission (AE) techniques were used to monitor the initiation and progression of damage in RT tensile tests on specimens with and without holes. Microscopy was performed on the polished edge of specimens without cooling holes and on the polished face of specimens with cooling holes that were tested in HCF and achieved runout. Comparisons were made with baseline specimens. Fractography was performed to examine the fracture surfaces of samples that failed under different loading conditions.

Ceramic Matrix Composites↗

Novel Processing, Testing and Characterization of Copper/Carbon Nanotube (Cu/CNT) Yarn Composite Conductor

Sustainable electrified aircraft propulsion (EAP) is likely to lead to an increase in the electrical wiring contained within a single aircraft. Since the electrical resistance and mass of copper (Cu) conductors are associated with power losses, it is desirable to design high-conductivity lightweight conductor materials, thus reducing the mass of components like motor windings, low-voltage signal cables, and transmission cables for data and power to improve the overall energy efficiency. This paper describes a unique framework for manufacturing metalized carbon nanotube (CNT) composite conductors, measuring their electrical conductivity and strength, and modeling the overall conductivity and current sharing within such composites. Tensile testing was conducted on the processed composite conductor cables with the use of acoustic emission and electrical resistivity to determine stress-dependent-failure mechanisms while monitoring the electrical conductivity. The average of measured electrical conductivities of annealed Cu/CNT samples from batch 5 was greater than theoretical predictions by 9.8 percent and was also greater than the conductivity of pure annealed Cu by 4.8 percent and had comparable ultimate tensile strengths. Additionally, those Cu/CNT samples provide a 13.5% weight saving over current state of the art copper wires. Theories explaining improved intrinsic conductivity are discussed.

Metalized CNT↗

Experimental investigation of probabilistic failure of SiC/SiC composite tubes under multiaxial loading

This paper presents an experimental investigation of the failure behavior of SiC fiber-reinforced SiC matrix (SiC/SiC) composite tubes under multiaxial loading. A new testing apparatus is designed to independently apply axial stress and internal pressure to SiC/SiC tubes. Acoustic emission (AE) is used to monitor the damage growth in the specimen. Based on the measured stress–strain response, a strain-based criterion is proposed to determine the proportional limit stress (PLS). The proposed strain-based criterion is compared with the PLS determined by the AE measurement. The PLS is determined for different loading ratios to form a multiaxial failure surface. By testing multiple replicates, the statistical variations of the PLS are determined. In conclusion, based on the experimental results, a mathematical model is developed to characterize the probability distribution of the PLS of SiC/SiC composites under multiaxial loading.

36 MATERIALS SCIENCE↗

DCIF (Directional Cooling-Induced Fracturing) Westerly Granite AE Borehole Damage Effect Test (Task 3-0)

Directional Cooling-Induced Fracturing (DCIF) experiments were conducted on three rectangular Westerly granite blocks (width=depth=4.0", height=2.0") which were preheated to 200, 400, and 600 degree C to induce damage (microcracks) with varying degrees. Liquid nitrogen was poured in a small, 1"-diameter copper cup attached to the top of the sample, and the resulting acoustic emissions (AEs) and temperature changes on the surface of the sample were monitored. The experiments were conducted under one selected biaxial stress (5.8MPa). The obtained AEs were used to determine the microcracking source locations and amplitude, and the associated moment tensors. The onset time of the AEs was correlated with the cooling temperature, which was used to show that the temperature at the onset of microcracking is not affected significantly by the preexisting damage, compared to the impact of the stress in the sample. Included in this submission are the animations of the AE locations and graphics displaying the measured temperature-AE activity changes for samples with different degrees of microcrack damage.

15 GEOTHERMAL ENERGY↗

Unveiling damage mechanisms of chromium-coated zirconium-based fuel claddings at LWR operating temperature by in-situ digital image correlation

Here, we investigate the coupled thermomechanical fracture mechanisms of coated nuclear fuel claddings at Light Water Reactor (LWR) operating temperatures. These coated claddings are a highly attractive, near-term solution, which addresses the demands for accident-tolerant fuel systems and provide greater oxidation resistance. However, the fracture mechanisms of these coatings, which may create channels for oxidation ingression, must be fully understood prior to implementation. Thus, high-temperature expanding plug experiments were conducted on coated cladding specimens at a temperature of 315 °C, consistent with the operating environment of LWRs. Furthermore, in-situ thermomechanical deformation was measured with stereo digital image correlation during heating and mechanical testing to separately resolve contributions of thermal and mechanical strain. Digital image correlation, supported by acoustic emissions (AE) detection, was also leveraged to track cracking activity during loading. Coating fracture was found to initiate at total hoop strains of 0.34%. The thermal deformation of the coated claddings was investigated via finite element simulations, revealing a bidirectional stress-state within the coating with axial and circumferential strains of 0.026 and 0.031%. This bidirectional stress-state was attributed with the generation of off-axis fracture pattern within the coating as identified via post-experiment scanning electron microscopy. Thus, this study unveiled critical, coupled thermomechanical mechanisms governing the coating fracture of coated claddings at LWR temperatures.

36 MATERIALS SCIENCE↗