Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Advancing 1D thermo-hydraulic tools for large cryogenic facilities

The Cryogenic Division at Fermilab develops large-scale cryogenic systems for particle accelerators and superconducting magnet test facilities. To support design and diagnostics, a Python-based code was created to calculate pressure drops in components such as valves and pipes. This paper presents recent enhancements to the code, including new heat transfer functions that improve the accuracy of thermal and hydraulic predictions. The first application models pressure and temperature changes in Proton Improvement Plant PIP-II relief pipes, aiding pipe sizing and protecting relief valves. The second example analyses heat load evolution in a pipe carrying sub-atmospheric helium, helping interpret temperature sensor data and understand gas return behavior to cold compressors. These improvements significantly expand the tool's capabilities, offering a practical resource for designing and troubleshooting cryogenic systems under dynamic thermal and flow conditions.

Beckwith, R. [Fermilab]↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Online Modelling and Optimization of Nonlinear Integrable Systems

Nonlinear integrable optics was recently proposed as a design approach to increase the limits on beam brightness and intensity imposed by fast collective instabilities. To study these systems experimentally, a new research electron and proton storage ring, the Integrable Optics Test Accelerator, was constructed and recently commissioned at Fermilab. Beam-based diagnostics and online modelling of nonlinear systems presents unique challenges - in this paper, we report on our efforts to develop optimization methods suited for such lattices. We explore the effectiveness of neural networks as fast online surrogate estimators, and integrate them into a beam-based tuning algorithm. We also develop a method of knob dimensionality reduction and subsequent robust multivariate optimization for maximizing key performance metrics under complicated lattice optics constraints.

43 PARTICLE ACCELERATORS↗

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade↗

Multi-messenger dynamic imaging of laser-driven shocks in water using a plasma wakefield accelerator

Understanding dense matter hydrodynamics is critical for predicting plasma behavior in environments relevant to laser-driven inertial confinement fusion. Traditional diagnostic sources face limitations in brightness, spatiotemporal resolution, and in their ability to detect relevant electromagnetic fields. In this work, we present a dual-probe, multi-messenger laser wakefield accelerator platform combining ultrafast X-rays and relativistic electron beams at 1 Hz, to interrogate a free-flowing water target in vacuum, heated by an intense 200 ps laser pulse. This scheme enables high-repetition-rate tracking the evolution of the interaction using both particle types. Betatron X-rays reveal a cylindrically symmetric shock compression morphology assisted by low-density vapor, resembling foam-layer-assisted fusion targets. The synchronized electron beam detects time-evolving electromagnetic fields, uncovering charge separation and ion species differentiation during plasma expansion – phenomena not captured by photons or hydrodynamic simulations. We show that combining both probes provides complementary insights spanning kinetic to hydrodynamic regimes, highlighting the need for hybrid physics models to accurately predict fusion-relevant plasma behavior.

imaging techniques↗

Beam impedance and heating analysis of the diagnostic stripline

In this work the heat transfer analysis has been performed for the stripline kicker, design of which is used at many accelerator facilities as a part of the transverse bunch-by-bunch feed-back system, including NSLS-II. The experimental data of the electrode temperature have been collected from a special diagnostic stripline designed with six infrared view ports. The temperature analysis is based on the power loss calculations and the loss factor computed by the 3-D electromagnetic simulation code GdfidL. To estimate the power loss, we analyze the real part of the longitudinal impedance and the loss factor for two different regimes. We use the ANSYS finite element code to correlate the temperature with the power loss. Lambertson and Shafer formalisms of the longitudinal and transverse beam impedances are discussed for the simplified stripline geometries. The required characteristic impedances and the geometric factors are determined analytically for the simplified geometries and compared with the results for the designed stripline geometry using the 2-D POISSON code by solving the Laplace’s equation in two dimensions. Lambertson’s equations are compared with numerical results. We introduce the frequency range, within which we can apply the analytical approach.

43 PARTICLE ACCELERATORS↗

Oxaliplatin–DNA Adducts as Predictive Biomarkers of FOLFOX Response in Colorectal Cancer: A Potential Treatment Optimization Strategy

FOLFOX is one of the most effective treatments for advanced colorectal cancer (CRC). However, cumulative oxaliplatin neurotoxicity often results in halting the therapy. Oxaliplatin functions predominantly via the formation of toxic covalent drug-DNA adducts. We hypothesize that oxaliplatin-DNA adduct levels formed in vivo in peripheral blood mononuclear cells (PBMC) are proportional to tumor shrinkage caused by FOLFOX therapy. We further hypothesize that adducts induced by sub-therapeutic "diagnostic microdoses" are proportional to those induced by therapeutic doses and are also predictive of response to FOLFOX therapy. These hypotheses were tested in CRC cell lines and a pilot clinical study. Four CRC cell lines were cultured with therapeutically relevant (100 µM) or diagnostic microdose (1 µM) concentrations of [ 14 C]oxaliplatin. The C-14 label enabled quantification of oxaliplatin-DNA adduct level with accelerator mass spectrometry (AMS). Oxaliplatin-DNA adduct formation was correlated with oxaliplatin cytotoxicity for each cell line as measured by the MTT viability assay. Six CRC patients received by IV a diagnostic microdose containing [ 14 C]oxaliplatin prior to treatment, as well as a second [ 14 C]oxaliplatin dose during FOLFOX chemotherapy, termed a "therapeutic dose." Oxaliplatin-DNA adduct levels from PBMC correlated significantly to mean tumor volume change of evaluable target lesions (5 of the 6 patients had measurable disease). Finally, oxaliplatin-DNA adduct levels were linearly proportional between microdose and therapeutically relevant concentrations in cell culture experiments and patient samples, as was plasma pharmacokinetics, indicating potential utility of diagnostic microdosing.

60 APPLIED LIFE SCIENCES↗

In situ Detection of Plasma Induced Surface Interaction based on Deep Learning based Visual Diagnostics (Technical Report)

It is characteristic for many plasma devices to undergo plasma-material interaction leading to surface erosion. These processes, often not easily detectable, lead to changes in device performance and lifespan. State-of-the-art lifetime tests and wear experiments require over 1000s hours. A self-consistent model for accurately predicting the erosion's effects is not available. In situ detection of these processes is not a trivial task since the surface variations at the early stages have a micron scale. Such limitations not only restrict testing and prediction capabilities but also slow the development of new thrusters and limit mission duration. To address these challenges, an in-situ diagnostic for real-time erosion assessment has been developed, aiming to expedite lifetime testing and broaden experimental campaigns. Several works were dedicated to real-time and in situ monitoring of material erosion during plasma exposure using laser holography, microscopy, and with telemicroscopes. However, the applicability of these approaches is limited due to complexity, cost and less flexibility as they often require placing diagnostic equipment inside the vacuum chamber. In collaboration with Princeton Collaborative Research Facility (PCRF), Princeton Plasma Physics Laboratory (PPPL), a new diagnostic approach is developed, where geometry modifications to the ceramic channel walls were introduced that would result in accelerated channel erosion. We employed Long-distance microscope (LDM) imagery, combined with Deep-Learning based Shape from focus or depth from focus (DFF or SFF) approach, that provides an accessible and cost-effective solution. LDM employs focus variation techniques to continuously capture multiple images of the target object at distinct focal planes. DFF, an optical focus variation method, generates a 3D topographical surface depth map from a sequence of variably focused images. Combined with the developed diagnostic, this approach offers a controllable means to study erosion under accelerated conditions. In this work, we develop Neural Network-based DFF algorithm applicable for LDM data to quantitatively evaluate plasma induced surface modification from LDM data. Next, we develop Deep Learning-based super-resolution depth map image reconstruction technique to increase the resolution of depth maps obtained from DFF algorithm to improve the accuracy of erosion measurements. Thirdly, we develop several image processing techniques to remove noise and improve the quality of depth map image. Here we report the results of initial tests for this approach. An experimental setup designed and built in PPPL was employed that consists of a 3-cm gridded ion source that produces a neutralized argon beam with energies up to 600 eV. A hexagonal boron nitride (h-BN) ceramic target, designed based on computational predictions, was used. Tests were conducted to reconstruct the complex geometry of the target under the lighting conditions of the operated ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chandra and the Emission Line Project

Calibration data obtained for the Chandra High Energy Transmission Grating and the Low Energy Transmission Grating Spectrometers are allowing us to test plasma spectral models against bright coronal sources with a range of electron temperatures. The three Emission Line Project targets - Capella, Procyon, and HR 1099 - are bright, well-studied X-ray and EUV emitters. The goals of the Emission Line Project are to determine and verify accurate and robust diagnostics; to identify and prioritize problems in fundamental spectroscopy; and to accelerate the improvement of the atomic database needed for modeling.

Brickhouse, N. S.↗

Intelligent Data Visualization for Cross-Checking Spacecraft System Diagnosis

Any reasoning system is fallible, so crew members and flight controllers must be able to cross-check automated diagnoses of spacecraft or habitat problems by considering alternate diagnoses and analyzing related evidence. Cross-checking improves diagnostic accuracy because people can apply information processing heuristics, pattern recognition techniques, and reasoning methods that the automated diagnostic system may not possess. Over time, cross-checking also enables crew members to become comfortable with how the diagnostic reasoning system performs, so the system can earn the crew s trust. We developed intelligent data visualization software that helps users cross-check automated diagnoses of system faults more effectively. The user interface displays scrollable arrays of timelines and time-series graphs, which are tightly integrated with an interactive, color-coded system schematic to show important spatial-temporal data patterns. Signal processing and rule-based diagnostic reasoning automatically identify alternate hypotheses and data patterns that support or rebut the original and alternate diagnoses. A color-coded matrix display summarizes the supporting or rebutting evidence for each diagnosis, and a drill-down capability enables crew members to quickly view graphs and timelines of the underlying data. This system demonstrates that modest amounts of diagnostic reasoning, combined with interactive, information-dense data visualizations, can accelerate system diagnosis and cross-checking.

Ong, James C.↗

Development and Operation of PIP-II Injector Test, SSR1 Cryomodule, 325 MHz Amplifiers

The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.

43 PARTICLE ACCELERATORS↗

Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator

This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.

47 OTHER INSTRUMENTATION↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

Revealing the three-dimensional structure of microbunched plasma-wakefield-accelerated electron beams

Abstract Plasma wakefield accelerators use tabletop equipment to produce relativistic femtosecond electron bunches. Optical and X-ray diagnostics have established that their charge concentrates within a micrometre-sized volume, but its sub-micrometre internal distribution, which critically influences gain in free-electron lasers or particle yield in colliders, has proven elusive to characterize. Here, by simultaneously imaging different wavelengths of coherent optical transition radiation that a laser-wakefield-accelerated electron bunch generates when exiting a metal foil, we reveal the structure of the coherently radiating component of bunch charge. The key features of the images are shown to uniquely correlate with how plasma electrons injected into the wake: by a plasma-density discontinuity, by ionizing high- Z gas-target dopants or by uncontrolled laser–plasma dynamics. With additional input from the electron spectra, spatially averaged coherent optical transition radiation spectra and particle-in-cell simulations, we reconstruct coherent three-dimensional charge structures. The results demonstrate an essential metrology for next-generation compact X-ray free-electron lasers driven by plasma-based accelerators.

43 PARTICLE ACCELERATORS↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Design of a precise and stable composite telescope structure for the Ultraviolet Coronagraph Spectrometer (UVCS)

The Ultraviolet Coronagraph Spectrometer is a state of the art instrument which will be flown aboard the ESA SOHO spacecraft in 1995. A major objective of the SOHO is to investigate the solar corona and the solar wind by measuring parameters of the plasma, both in the source and acceleration regions, and in interplanetary space. The UVCS will provide ultraviolet spectroscopic diagnostics of temperature, density, and outflow velocity for coronal ions located between the base of the solar corona and 10 solar radii. The requirements placed on the UVCS telescope structure by the science and the spacecraft are challenging. Obtaining this scientific data requires that the telescope maintain pointing stability within a few arc-seconds in a transient thermal environment and an imaging stability within a few microns. Strict mass allowances permit only 22 kg for the 2.5 meter long telescope structure out of a total instrument allotment of 124 kg. The instrument is required to have a high minimum natural frequency of 70 Hertz and withstand launch inertia loads in excess of 18-G's while kinematically supported.

Kilpatrick, Mark C.↗

Studies of Fundamental Particle Dynamics in Microgravity

This work summarizes theoretical and experimental concepts used to design the flight experiment mission for SHIVA - Spaceflight Holography Investigation in a Virtual Apparatus. SHIVA is a NASA project that exploits a unique, holography-based, diagnostics tool to understand the behavior of small particles subjected to transient accelerations. The flight experiments are designed for testing model equations, measuring g, g-jitter, and other microgravity phenomena. Data collection will also include experiments lying outside of the realm of existing theory. The regime under scrutiny is the low Reynolds number, Stokes regime or creeping flow, which covers particles and bubbles moving at very low velocity. The equations describing this important regime have been under development and investigation for over 100 years and yet a complete analytical solution of the general equation had remained elusive yielding only approximations and numerical solutions. In the course of the ongoing NASA NRA, the first analytical solution of the general equation was produced by members of the investigator team using the mathematics of fractional derivatives. This opened the way to an even more insightful and important investigation of the phenomena in microgravity. Recent results include interacting particles, particle-wall interactions, bubbles, and Reynolds numbers larger than unity. The Space Station provides an ideal environment for SHIVA. Limited ground experiments have already confirmed some aspects of the theory. In general the space environment is required for the overall experiment, especially for cases containing very heavy particles, very light particles, bubbles, collections of particles and for characterization of the space environment and its effect on particle experiments. Lightweight particles and bubbles typically rise too fast in a gravitational field and heavy particles sink too fast. In a microgravity environment, heavy and light particles can be studied side-by-side for long periods of time.

Rangel, Roger↗