Contributions to X-ray physics in space
Background radiation in space and synchrotron X radiation in galaxy and pulsars
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Background radiation in space and synchrotron X radiation in galaxy and pulsars
In this work, we present the technology-aided computer design (TCAD) device simulation and modeling of a silicon p-i-n diode for detecting time-dependent X-ray radiation. We show that the simulated forward and reverse breakdown current–voltage characteristics agree well with the measured data under nonradiation environment by only calibrating carrier lifetimes for the forward bias case and avalanche model critical fields for the reverse bias condition. Using the calibrated parameters and other nominal material properties, we simulated the radiation responses of the p-i-n diode and compared with experimental data when the diode was exposed to X-ray radiation at Sandia’s Saturn facility and the Idaho State University (ISU) TriMeV facility. For Saturn’s Gaussian dose-rate pulses, we show three findings from TCAD simulations. First, the simulated photocurrents are in excellent agreement with the measured data for two dose-rate pulses with peak values of 1.16×10 10 and 1.88×10 10 rad(Si)/s. Second, the simulation results of high dose-rate pulses predict increased delayed photocurrents with longer time tails in the diode electrical responses due to excess carrier generation. Third, simulated peak values of diode radiation responses versus peak dose rates at different bias conditions provide useful guidance to determine the dose-rate range that the p-i-n diode can reliably detect in experiment. For TriMeV’s non-Gaussian dose-rate pulse, our simulated diode response is in decent agreement with the measured data without further calibration. We also studied the effects of device geometry, recombination process, and dose-rate enhancement via TCAD simulations to understand the higher measured response in the time after the peak dose-rate radiation for the p-i-n diode exposed to TriMeV irradiation.
The Nowcast of Aerospace Ionizing RAdiation System (NAIRAS) model predicts dosimetric and radiative flux quantities for assessing human radiation exposure levels and radiation effects on flight electronic systems from the surface of the Earth to deep space. NAIRAS version 3 includes many updates and improvements to the model. In this paper, NAIRAS version 3 dosimetric quantities are compared to observations of the atmospheric radiation environment taken during the Radiation Dosimetry Experiment (RaD-X) flight campaign. The RaD-X campaign consisted of a high-altitude balloon flight, with altitudes up to 40 km, and four coordinated aircraft flights covering an altitude range from 6-20 km. The RaD-X measurement data from the different flight platforms were acquired in September 2015 and at nearly the same vertical cutoff rigidity (3-4 GV). High quality, flight-averaged measurement data were provided at seven altitudes, which correspond to regions of fundamentally different radiation transport and collisional interaction physics. The NAIRAS model agrees with the RaD-X measurements to within 30% over the entire altitude domain of the flight campaign (0-40 km), which is within the measurement uncertainty.
Schottky barrier diodes were fabricated on (001) monoclinic β-Ga 2 O 3 wafers with low doped epitaxial layers of 7.0 × 10 15 cm −3 . Circular Ni Schottky contacts with area 2 mm 2 were deposited by electron beam evaporation. Devices were characterized electrically by performing forward and reverse current-voltage sweeps with a range of −100 V–2 V, as well as capacitance-voltage sweeps to −30 V. The breakdown voltage was also determined to be −180 V for the devices. Experiments measuring the electrical response from incident X-ray radiation was performed. A response time to X-ray radiation of less than 1 s was recorded and a decay time of approximately 2 s after removing X-ray source, which primarily attribute to X-ray switching on and off time. Energy spectra of alpha particles from a 0.9 μCi 241 Am button source was collected at various voltage biases using devices with the lowest measured leakage current while reverse biased. The total count rate was observed to increase linearly with increasing device bias. In conclusion, the peak channel number was observed to increase with increasing bias with the best resolution of 9.5% at −100 V reverse bias.
Relativistic electron energy loss due to inverse Compton scattering from cosmological blackbody radiation, noting diffuse X ray background implication for electron source strength
This paper presents calculations of the effect of changing X-ray ionization conditions on the radiative force experienced by the stellar wind material in a massive X-ray binary system. The radiative line force from the radiation field of the primary is parameterized in terms of the Castor et al. (1975) force multiplier. The results show that the line force decreases sharply, but in a nonlinear way, with increasing X-ray ionization. The dynamic consequences of this effect are discussed.
A one-dimensional radiation-hydrodynamics code is used to numerically investigate the structure and evolution of shocks in the winds of hot stars. Results are presented for the specific case of Tau Sco, a well-studied main-sequence B star for which there are X-ray data from the Einstien satellite's Solid State Spectrometer. A phenomenological radiative acceleration term and a mass-loss rate consistent with UV observations, are used to determine the time dependence of the temperatures within and X-ray emission from an isolated shock region. The driving acceleration leads to the formation of a two-component shock zone with 'forward' and 'reverse' shocks, each with their own characteristic temperature. A denser cold region forms between the two shocks, which could potentially account for the presence of narrow absorption features that are observed in the UV P Cygni profiles of many hot stars. The X-ray emission spectra from the shocks in the calculations are in good general agreement with two-temperature model fits to Einstein X-ray observations.
The Gas Pixel Detector (GPD) is an X-ray polarimeter to fly onboard IXPE and other missions. To correctly measure the source polarization, the response of IXPE’s GPDs to unpolarized radiation has to be calibrated and corrected. In this paper, we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and nonmonochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.
Various solar physical data are presented including: data for January 1984--(solar radio bursts af fixed frequencies, solar X-ray radiation from GOES satellite, Mass ejections from the sun); data for August 1981--solar flares; Miscellaneous data--(meudon carte synoptique, solar X-ray radiation from GOES satellite).
Linear accelerators (linacs), producing electron or X-ray radiation in the MeV range, are critical tools for industrial irradiation, medical device sterilization, food pasteurization, non-destructive testing, security, medical, and many other applications. Many of these applications require compact and flexible radiation sources. In this paper, we present new technologies for small-scale electron linear accelerators and examples of their practical implementations. Furthermore, these developments include low energy accelerators with self-shielding options and form factors, ranging from cabinet-size to hand-portable generators; medium-energy accelerators for novel radiotherapy and security applications; and high-energy 10 MeV linacs capable of reaching 20–35 kW beam power for emerging industrial and phytosanitary applications
The research focused on molecular hydrogen and its response to ultraviolet radiation, photoelectron impact excitation and X-ray radiation and on the interpretation of the ultraviolet spectra of the Jupiter dayglow and auroras. A systematic effort was made to obtain reliable rate coefficients for rovibrational energy transfer of H2, particularly in collisions with hydrogen atoms. We carried out elaborate quantum-mechanical calculations of the scattering of H and H2 on what had been characterized as a reliable potential energy surface of the H3 molecular system. These calculations took into account reactive channels and rate coefficients for ortho-para transitions were obtained. Quantal calculations are too complex to be applied to all the possible rovibrational transitions and we turned to a semi-classical method. With it we calculated rate coefficients for transitions, reactive and non-reactive, for all the rovibrational levels. We carried out the calculations for three of the available H3 potential energy surfaces. We discovered an unexpected sensitivity of the rate coefficients for the non-reactive channels to the potential energy surface. This discovery stimulated more thorough investigations of the potential energy surface elsewhere and to the construction of a new surface. We have used it in further semi-classical calculations in work that will shortly be 2 completed and which, together with new quantum-mechanical calculations should comprise a set of reliable rate coefficients that can be used in discussions of H2 on the Jovian planets. We carried out a detailed study of the Jovian ultraviolet dayglow. There has been a long-running argument about the dayglow on Jupiter. There are two sources of excitation: fluorescence and photoelectron impact excitation. It had been argued that a third source "the electron glow" was needed to bring theory and observation into agreement. We believe we have shown conclusively that the third source is unnecessary. We have achieved a close quantitative agreement between the predicted spectrum arising from fluorescence and photoelectrons and the measured spectrum. We also demonstrated a method by which the presence of HD could be established observationary. Similar calculations were carried out of the ultraviolet spectra of the Jovian auroras. We again found close agreement. Indeed, the agreement was so detailed we were able to derive the temperature of the atmosphere. We found, contrary to the standard model of the time, a high temperature between 400 K and 600 K and established the presence of a significant temperature gradient. A large temperature gradient was indeed found by direct sampling with the Jupiter probe.
The Mars Exploration Rovers Spirit and Opportunity landed at Gusev crater and Meridiani Planum. The Alpha Particle X-ray Spectrometer (APXS) is part of the instrument suite on both rovers. It is equipped with six 244Cm sources which provide x-ray excitation with alpha-particles (PIXE) and x-ray radiation (XRF). This combination allows x-ray spectroscopy of elements from Na to Br in the energy range of 0.9 to 16 keV. X-ray detectors with a high energy resolution of 160 eV at Fe K allow us to separate even closely spaced energy peaks, such as Na, Mg, Al and Si. The APXS is attached to the rover s arm and provides in-situ measurements of the chemical composition of soils, surfaces of rocks and outcrops and their abraded surfaces. This abstract gives an overview of APXS results obtained during the first year of operation on both landing sites.
We present results of five Nuclear Spectroscopic Telescope Array (NuSTAR) observations of the type 2 active galactic nucleus (AGN) in IC 751, three of which were performed simultaneously with XMM-Newton or Swift/ X-Ray Telescope. We find that the nuclear X-ray source underwent a clear transition from a Compton-thick (NH approx. = 2 x10(exp 24)/sq cm) to a Compton-thin ( N(sub H) approx. = 4 x10(exp 23)/sq cm) state on timescales of < or approx.3 months, which makes IC 751 the first changing look AGN discovered by NuSTAR. Changes of the line of sight column density at the approx.2 (sigma) level are also found on a timescale of approx. 48 hr (delta N(sub H approx. 10(exp 23)/sq cm). From the lack of spectral variability on timescales of approx.100 ks, we infer that the varying absorber is located beyond the emission-weighted average radius of the broad-line region (BLR), and could therefore be related either to the external part of the BLR or a clumpy molecular torus. By adopting a physical torus X-ray spectral model, we are able to disentangle the column density of the non-varying absorber (N(sub H) approx. 3.8 x10(exp 23)/sq cm) from that of the varying clouds [N(sub H) approx. (1- 150) x 10(exp 22)/sq cm], and to constrain that of the material responsible for the reprocessed X-ray radiation (N(sub H approx. 6 x 10(exp 24)/sq cm).24 -2). We find evidence of significant intrinsic X-ray variability, with the flux varying by a factor of five on timescales of a few months in the 2-10 and 10-50 keV band.
We constructed the first simultaneous dark- and bright-field X-ray microscope in this experiment, coupling it to simultaneous measurements of the wide-angle Xray diffraction, and the XFEL pulse intensity and energy spectrum on each shot. This experiment established proof of concept for this new advanced measurement technique and demonstrated DFXM at an XFEL for the first time. Within this complex experiment, we also acquired data that advanced our research goals within materials science and mathematics. These included: A preliminary study of how local effects reduce the X-ray damage threshold in diamond; A preliminary study of how X-ray radiation imparts heat into materials based on irreversible phase transitions that occur in boric acid with increasing temperature (based on hydration); A study of X-ray radiation damage from ultrafast thermal cycling and nonthermal melting in bismuth selenide; We also began developing software to automate alignment of compound refractive lenses (CRLs) using stochastic Nelder-Mead optimization methods. This work will expedite and improve the accuracy of alignments for many future experiments using CRLs.
Equations describing the evolution of a thin, axisymmetric, viscous, relativistic, irradiated accretion disk are presented, as well as numerical solutions of these equations in the case where irradiation results from a thermonuclear flash on the surface of the accreting neutron star. These calculations verify the notion that the radiation torque induces a substantial increase in the accretion rate, during a type 1 X-ray burst, and provide insight into the factors which influence the dynamical response of the disk. A new model for the source XBT 1730-335, the rapid burster, is presented. Temporal and spectral properties are calculated. The rapid burster is found to be a nonmagnetic, 'critically compact', slowly rotating neutron star in a highly eccentric binary system with a period of 6 mo. The spectral modifications which arise from the scattering of photons by accretion disks around nonmagnetic neutron stars are calculated. The 'black hole candidates' are interpreted as extremely compact stars.
The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.
Predicting the emerging X-ray spectra in several astrophysical objects is of great importance, in particular when the observational data are compared with theoretical models. This requires developing numerical routines for the solution of the radiative transfer equation according to the expected physical conditions of the systems under study. Aims. We have developed an algorithm solving the radiative transfer equation in the Fokker-Planck approximation when both thermal and bulk Comptonization take place. The algorithm is essentially a relaxation method, where stable solutions are obtained when the system has reached its steady-state equilibrium. Methods. We obtained the solution of the radiative transfer equation in the two-dimensional domain defined by the photon energy E and optical depth of the system pi using finite-differences for the partial derivatives, and imposing specific boundary conditions for the solutions. We treated the case of cylindrical accretion onto a magnetized neutron star. Results. We considered a blackbody seed spectrum of photons with exponential distribution across the accretion column and for an accretion where the velocity reaches its maximum at the stellar surface and at the top of the accretion column, respectively. In both cases higher values of the electron temperature and of the optical depth pi produce flatter and harder spectra. Other parameters contributing to the spectral formation are the steepness of the vertical velocity profile, the albedo at the star surface, and the radius of the accretion column. The latter parameter modifies the emerging spectra in a specular way for the two assumed accretion profiles. Conclusions. The algorithm has been implemented in the XPEC package for X-ray fitting and is specifically dedicated to the physical framework of accretion at the polar cap of a neutron star with a high magnetic field (approx > 10(exp 12) G). This latter case is expected to be of typical accreting systems such as X-ray pulsars and supergiant fast X ray transients.
In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.