Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Western”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Western Regional Center of the National Institute for Climatic Change Research

The major goal of this project was fostering, integrating, synthesizing, and disseminating experimental, observational, and modeling research on predicted climate change in the western region of the U.S. and the impacts of that change on the structure, productivity, and climatic interactions of the region's natural and managed ecological systems. This was accomplished through administering a competitive grants program developed in collaboration with the other four regional centers of the NICCR. The activities supported included efforts to synthesize research on climate change in the western U.S. through meta-analysis studies, model comparisons, and data synthesis workshops. Results from this work were disseminated to the scientific and public media. This project also supported the development of the NICCR web site, hosted at NAU, which was used as the means to accept pre-proposal and proposal submissions for each funding cycle, and served as a clearing house for public outreach for results from NICCR-funded research

54 ENVIRONMENTAL SCIENCES↗

Operation of Concentrating Solar Power Plants in the Western Wind and Solar Integration Phase 2 Study

The Western Wind and Solar Integration Study (WWSIS) explores various aspects of the challenges and impacts of integrating large amounts of wind and solar energy into the electric power system of the West. The phase 2 study (WWSIS-2) is one of the first to include dispatchable concentrating solar power (CSP) with thermal energy storage (TES) in multiple scenarios of renewable penetration and mix. As a result, it provides unique insights into CSP plant operation, grid benefits, and how CSP operation and configuration may need to change under scenarios of increased renewable penetration. Examination of the WWSIS-2 results indicates that in all scenarios, CSP plants with TES provides firm system capacity, reducing the net demand and the need for conventional thermal capacity. The plants also reduced demand during periods of short-duration, high ramping requirements that often require use of lower efficiency peaking units. Changes in CSP operation are driven largely by the presence of other solar generation, particularly PV. Use of storage by the CSP plants increases in the higher solar scenarios, with operation of the plant often shifted to later in the day. CSP operation also becomes more variable, including more frequent starts. Finally, CSP output is often very low during the day in scenarios with significant PV, which helps decrease overall renewable curtailment (over-generation). However, the configuration studied is likely not optimal for High Solar Scenario implying further analysis of CSP plant configuration is needed to understand its role in enabling high renewable scenarios in the Western United States.

14 SOLAR ENERGY↗

Scenarios for Deep Carbon Emission Reductions from Electricity by 2050 in Western North America using the Switch Electric Power Sector Planning Model: California's Carbon Challenge Phase II, Volume II

This study used a state-of-the-art planning model called SWITCH for the electric power system to investigate the evolution of the power systems of California and western North America from present-day to 2050 in the context of deep decarbonization of the economy. Researchers concluded that drastic power system carbon emission reductions were feasible by 2050 under a wide range of possible futures. The average cost of power in 2050 would range between $149 to $232 per megawatt hour across scenarios, a 21 to 88 percent increase relative to a business-as-usual scenario, and a 38 to 115 percent increase relative to the present-day cost of power. The power system would need to undergo sweeping change to rapidly decarbonize. Between present-day and 2030 the evolution of the Western Electricity Coordinating Council power system was dominated by implementing aggressive energy efficiency measures, installing renewable energy and gas-fired generation facilities and retiring coal-fired generation. Deploying wind, solar and geothermal power in the 2040 timeframe reduced power system emissions by displacing gas-fired generation. This trend continued for wind and solar in the 2050 timeframe but was accompanied by large amounts of new storage and long-distance high-voltage transmission capacity. Electricity storage was used primarily to move solar energy from the daytime into the night to charge electric vehicles and meet demand from electrified heating. Transmission capacity over the California border increased by 40 - 220 percent by 2050, implying that transmission siting, permitting, and regional cooperation will become increasingly important. California remained a net electricity importer in all scenarios investigated. Wind and solar power were key elements in power system decarbonization in 2050 if no new nuclear capacity was built. The amount of installed gas capacity remained relatively constant between present-day and 2050, although carbon capture and sequestration was installed on some gas plants by 2050.

14 SOLAR ENERGY↗

Coordinating Demand-Side Efficiency Evaluation, Measurement and Verification Among Western States: Options for Documenting Energy and Non-Energy Impacts for the Power Sector

Demand-side energy efficiency (efficiency) represents a low-cost opportunity to reduce electricity consumption and demand and provide a wide range of non-energy benefits, including avoiding air pollution. Efficiency-related energy and non-energy impacts are determined and documented by implementing evaluation, measurement and verification (EM&V) systems. This technical brief describes efficiency EM&V coordination strategies that Western states can consider taking on together, outlines EM&V-related products that might be appropriate for multistate coordination, and identifies some implications of coordination. Coordinating efficiency EM&V activities can save both time and costs for state agencies and stakeholders engaged in efficiency activities and can be particularly beneficial for multiple states served by the same utility. First, the brief summarizes basic information on efficiency, its myriad potential benefits and EM&V for assessing those benefits. Second, the brief introduces the concept of multistate EM&V coordination in the context of assessing such benefits, including achievement of state and federal goals to reduce air pollutants.1 Next, the brief presents three coordination strategy options for efficiency EM&V: information clearinghouse/exchange, EM&V product development, and a regional energy efficiency tracking system platform. The brief then describes five regional EM&V products that could be developed on a multistate basis: EM&V reporting formats, database of consistent deemed electricity savings values, glossary of definitions and concepts, efficiency EM&V methodologies, and EM&V professional standards or accreditation processes. Finally, the brief discusses options for next steps that Western states can take to consider multistate coordination on efficiency EM&V. Appendices provide background information on efficiency and EM&V, as well as definitions and suggested resources on the covered topics. This brief is intended to inform state public utility commissions, boards for public and consumer-owned utilities, state energy offices and air agencies, and other organizations involved in discussions about the use of efficiency EM&V.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The use of wholesale market purchases by Western U.S. electric utilities

Load Serving Entities (LSEs) can procure electricity from their owned generation or purchase it on bilateral or centrally organized markets. Electric utility procurement decisions have important implications for resource adequacy, which is gaining attention especially in the Western U.S. However, there is little or no research on trends of utility procurement practices, and the role that wholesale market transactions can have for resource adequacy and other applications. This paper leverages information from the U.S. Department of Energy’s Energy Information Administration, Berkeley Lab’s Resource Planning Portal, and structured interviews with regulatory and utility staff. We find that use of market transactions to meet electric energy needs has been increasing across U.S. LSEs. The reasons for this trend include a general stagnation in building owned resources, a preference towards contracting renewable energy resources to meet RPS targets, and the lower relative cost of wholesale market electricity. Among market transactions across different time scales, short-term transactions were prevalent in Western U.S. LSEs until the 2008 recession, and thereafter declined to about a quarter of total purchases. In contrast, long-term market transactions have become more prevalent and resource planning reports project the share of these transactions in the procurement mix may continue to increase. Results suggest resource adequacy obligations may drive preferences for asset ownership more than a profit incentive. We also recommend improving the planning to procurement connection by reflecting in planning assumptions the operational constraints of market transactions. These results provide insights on key issues in electric utility procurement that could improve overall market efficiency, respond to rapidly changing industry conditions, and identify practices that LSEs and regulators should consider incorporating into their long-term transmission and capacity planning processes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Western sector in-situ chemical oxidation project: Supplemental results after injection activities

The purpose of the Western Sector ISCO project is to inject chemical oxidants (i.e., potassium permanganate and sodium persulfate) into the eight injections wells (i.e., WSI001B, WSI001C, WSI002B, WSI002C, WSI003B, WSI003C, WSI004B, and WSI004C) and evaluate the effectiveness of the chemical oxidants at degrading indiscriminate DNAPL that is present in the subsurface. Fifteen monitoring wells (i.e., WSM001BB, WSM001B, WSM001CC, WSM001C, WSM002BB, WSM002B, WSM002CC, WSM002C, WSM003BB, WSM003B, WSM003CC, WSM003C, MSB107B, MSB107CC, and MSB107C) are currently being used by SRS to monitor the effect of the oxidant injections on the VOC plume of the Western Sector of the M-Area HWMF. Figure 1 shows the project location in reference to the M-Area Settling Basin. This is the second of three planned interim reports to track the performance of the project. The purpose of this document is to report groundwater monitoring data collected during the baseline monitoring before oxidant injections occurred and the fifteen months after oxidant injections were completed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pahute Mesa-Oasis Valley Hydrostratigraphic Framework Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada (Rev. 0)

A new, revised three-dimensional (3-D) hydrostratigraphic framework model (HFM) for the Central and Western Pahute Mesa Corrective Action Units 101 and 102 was completed in 2019. The initial (Phase I) model was completed in 2002 and was documented in A Hydrostratigraphic Model and Alternatives for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada (BN, 2002). Subsequent flow and transport modeling revealed the need to collect additional data to reduce uncertainties. The Phase II data collection and characterization effort included extensive well drilling and testing activities, and rebuilding of the Phase I 3-D HFM, resulting in the Phase II HFM (NSTec, 2014). Further drilling (Well ER-20-12), data collection, and interpretive work (e.g., Thirsty Canyon Lineament [Wurtz and Day, 2018]) were incorporated into the Pahute Mesa-Oasis Valley (PM-OV) HFM. The PM-OV HFM incorporates the area of interest from the Phase II HFM and adds additional areas, primarily to the north and west with minor additions to the south and east. The new, expanded area matches the PM-OV groundwater basin as defined in Fenelon et al. (2016) and includes Pahute Mesa, a former nuclear testing area at the Nevada National Security Site; and Oasis Valley, a groundwater discharge area downgradient from contaminant source areas on Pahute Mesa. The data and information necessary to build the PM-OV HFM are provided in Navarro (2019). The PM-OV HFM will be used by hydrologic modelers who are tasked with developing a model to determine how contaminants are transported by groundwater flow in an area of complex geology. The model area is large (more than 6,250 square kilometers) and geologically complex, including Paleozoic- to Mesozoic-age structures (e.g., thrust faults, Thirsty Canyon Lineament), at least seven Tertiary-age calderas, several intrusive bodies, and many relatively recent basin-and-range normal faults. Investigators from the U.S. Geological Survey; National Security Technologies, LLC; National Laboratories; and U.S. Department of Energy contractors have organized the more than 300 volcanic units and other rocks in the model area into 77 hydrostratigraphic units (HSUs). The volcanic rocks are subdivided into 42 aquifers, 11 confining units, and 9 composite units (containing both aquifer and confining unit rocks). The underlying pre-Tertiary rocks were divided into 5 HSUs, comprising 2 aquifers and 3 confining units. The model also includes 1 alluvial aquifer unit, 8 intrusive confining units, and 1 granite confining unit. The model depicts the thickness, extent, and geometric relationships of these HSUs (“layers” in the model) along with all the major structural features that control them, including calderas and faults. The most substantive differences between the Phase II HFM and the PM-OVHFM include (1) addition of the new data and resulting revised interpretations from the additional area encompassed by the PM-OV groundwater basin; (2) incorporation of 16 new faults; (3) 12 boreholes from the northern extension; (4) 2 additional caldera-collapse collars; and (5) correlation of the simulated faulting and hydrostratigraphy in the eastern part of the model domain with the delineations represented in the neighboring Rainier Mesa-Shoshone Mountain HFM-Prime and Yucca Flat-Climax Mine HFM. All PM-OV HFM delineations were based on published and unpublished data from geophysical investigations, surface geologic maps, and drill-hole records. Phase II approached model uncertainty using the model-building software to test model configurations and hydrologic consequences using a range of values for parameters such as fault offset amounts and HSU elevations. The PM-OV HFM expands on this approach to encompass the entire PM-OV groundwater basin.

54 ENVIRONMENTAL SCIENCES↗

Implications of a regional resource adequacy program on utility integrated resource planning: Study for the Western United States

LBNL collaborated with the Western Interstate Energy Board and the University of Texas, Austin to investigate the implications of a regional resource adequacy (RA) program on utility integrated resource planning. This report is focused on an active policy discussion to develop a novel voluntary program to share capacity resource and improve RA in the Western Interconnection. This report identifies two RA components of IRP that will be highly impacted by a regional RA program: resource capacity accreditation and RA targets. There are at least four resources that will require specific attention for their capacity credit calculation: (1) variable renewable resources, (2) demand-side resources, (3) hydropower, and (4) contracts. It will then be necessary to decide on a RA target reliability metric (e.g., a planning reserve margin) that is at least the minimum requirement in IRPs to ensure consistency in RA requirement calculations. The report finds that load forecasting and transmission expansion analyses will be moderately impacted, but that most of IRP components will not be significantly impacted. The report includes (i) a review of traditional resource adequacy practices in IRP; (ii) a case study of an existing regional RA program that interacts with IRP (Southwest Power Pool) and (iii) an overview of the NWPP regional resource adequacy proposal that is the object of this work. This paper does not (1) advocate for or against a regional RA program for the NWPP, (2) make detailed design recommendations for this program, or (3) assess its benefits and costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Distributed Solar Photovoltaic Deployment via Barrier Mitigation or Removal in the Western Interconnection (Final Technical Report)

In 2017, the Western Electricity Coordinating Council (WECC) 2026 Common Case projected that distributed solar PV deployment in the Western U.S. would meet or exceed 16,106 MW of installed capacity by 2026. Of this total, 12,218 MW was projected to be deployed in California and another 3,888 MW was projected to be deployed across Arizona, Colorado, Idaho, Montana, Nevada, New Mexico, Oregon, Utah, Washington, and Wyoming. However, WIEB recognized that barriers to distributed solar PV deployment could cause the region to fall short of these projections. WIEB identified three types of perceived barriers that might interfere with the deployment of distributed solar PV generation in the West, including: (1) interconnection barriers; (2) utility rate-design barriers; and (3) reliability barriers.

14 SOLAR ENERGY↗

Contaminant Transport Parameters for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This document presents a summary and framework of available transport data and other information directly relevant to the development of the groundwater transport model for Central and Western Pahute Mesa (PM) corrective action units (CAU). This model is referred to as the “PM CAU transport model” in this document. Central and Western PM are two areas of the Nevada National Security Site (NNSS) that historically were used for underground nuclear testing. These nuclear tests resulted in groundwater contamination in the vicinity of the underground test areas. As a result, the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program is currently conducting a corrective action investigation (CAI) of the PM underground test areas. This work is a part of the Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unclassified Source Term and Radionuclide Data for the Groundwater Flow and Contaminant Transport Model for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This report documents the evaluation of information and data available on the unclassified source term and radionuclide (RN) contamination for Central and Western Pahute Mesa (PM): Corrective Action Units (CAUs) 101 and 102. The Central and Western PM CAUs constitute two areas of the Nevada National Security Site (NNSS) used for underground nuclear testing (Figure 1-1). Eighty-five underground nuclear tests were conducted at the PM CAUs between 1965 and 1992 (NNSA/NFO, 2015b). Underground nuclear tests deposit radioactive elements in the subsurface, resulting in groundwater contamination in the vicinity of the underground test locations. At the PM CAUs, the testing resulted in more than 2.68 × 10 7 curies (Ci) of radioactivity (decay-corrected to September 30, 2012) remaining underground (Finnegan et al., 2016). Of the 85 underground nuclear tests conducted at the PM CAUs, three were shallow tests detonated within 200 meters (m) of the surface and referred to as the “near-surface tests”; the remaining 82 were detonated deeper than 200 m below ground surface (bgs) and are referred to as the “deep underground tests” in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydrologic Data for the Groundwater Flow and Contaminant Transport Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nye County, Nevada, Revision 1

This hydrologic data document (HDD) has been prepared for Corrective Action Units (CAUs) 101 and 102, Central and Western Pahute Mesa, in order to support the development of a groundwater flow and contaminant transport model. Central and Western Pahute Mesa are two of the five CAUs on the Nevada National Security Site (NNSS) (formerly the Nevada Test Site [NTS]) used for underground nuclear testing (Figure 1-1). The nuclear tests resulted in groundwater contamination in the vicinity of the underground test areas. As a result, the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program is currently conducting a corrective action investigation (CAI) of the Pahute Mesa underground test areas. This work is a part of the Underground Test Area (UGTA) Activity in accordance with the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The CAU groundwater flow and transport model is composed of two pieces, a flow model and a transport model, that together provide the contaminant boundary forecasts required by the FFACO. The hydrologic data necessary for the flow model portion of the CAU model are presented in this report. The transport data necessary for the transport model portion of the CAU model will be provided in a separate report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Western Interconnection Baseline Study

The purpose of the baseline study is to evaluate the degree to which current industry planning processes meet the national 2035 decarbonization goals for the Western Interconnection. This analysis serves as a comparative baseline for the scenario analysis conducted in the NTP Study using a Western Interconnection dataset that is readily available to industry. This baseline analysis differs from the production cost modeling analysis and power flow analysis in the main NTP Study report (forthcoming). In particular, the analysis presented in this report reflects a business-as-usual future with an optimistic build out of specific planned transmission projects and foreseeable generation. In contrast, the NTP Study models a future generation and transmission expansion based on optimization from a capacity expansion model. The analysis presented herein also reflects a 2030 timeframe, whereas the main NTP Study production cost modeling analysis and power flow analysis reflect a 2035 time frame. This baseline analysis utilizes industry’s most reliable data to account for future transmission projects across various stages of development, with a particular focus on those in the permitting stage. Additionally, it incorporates projections for changes in generation capacity (both additions and retirements). This baseline analysis outlines a probable trajectory, given current process and practice, for the future of the bulk power system with a horizon extending to 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Surface heat flux and its association with the MJO in the tropical western Pacific using ARM observations

The Madden-Julian oscillation (MJO) is a major atmospheric phenomenon in the tropics that moves eastward every 20 to 100 days. It brings heavy rain and strong winds, influencing extreme weather events far beyond the tropics – including flooding, hurricanes, tornadoes and heavy snow in the United States. Therefore, an improved understanding of the MJO is critical for enhancing weather forecasts and supporting better decision-making for communities, emergency managers, and the private sector. Past studies, based on short-term observations or long-term model data, have emphasized the dominant role of atmospheric humidity in driving the MJO. Our research, using long-term observations (2000-2014) from three U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) sites in the tropical western Pacific (Manus, Nauru, and Darwin) confirms those past findings. However, we also show that atmospheric temperature, especially in the mid and upper troposphere, also plays a key role in the MJO’s evolution from its quiet (suppressed) to convective (active) phase. These findings provide valuable insights into how the MJO evolves and may help evaluate and improve weather and climate models. Our study also examined how the exchange of heat between the Earth's surface and the atmosphere, called surface heat flux, interacts with the MJO. This flux includes components such as latent heat (related to evaporation), sensible heat (related to temperature difference between surface and atmosphere), and radiation. We found that modulation in MJO convection is well connected to surface heat flux over the tropical western Pacific. One surface heat flux component often overlooked is the sensible heat flux due to precipitation (Q P ). Since falling raindrops are typically cooler than the land or ocean surface, they can cool the surface and affect local weather. To test the impact of Q P on convection during MJO, we incorporated it into a weather model, and ran simulations for two periods: April 2009 (when the MJO was active) and June 2006 (when it was not). Including Q P reduced errors in simulating the daily peak of rainfall—by 83% during the strong MJO and 23% during the inactive phase. It also improved the timing of peak daily rainfall and reduced the overall precipitation error by about 10%. These improvements were especially noticeable during periods of heavy rainfall. Our results suggest that even small heat exchanges from rainfall can play a significant role in shaping local weather. Accounting for these effects, particularly in regions like the tropical islands, can lead to more accurate simulations of the MJO-associated precipitation.

54 ENVIRONMENTAL SCIENCES↗

Development of a Western U.S. Fusion Energy Commercialization Hub

Fusion energy, if successfully commercialized and globally adopted, could substantially increase U.S. energy dominance and provide essentially unlimited baseload power for the national grid. It also stands to provide the U.S. with a strong source of economic growth through the 2030s and 2040s, giving the U.S. a new and highly internationally competitive industry for export. Fusion can also provide the increased electrical power generation capacity required to power current and future artificial intelligence (AI) activities. In October 2024, the CleanTech Alliance held a fusion energy commercialization regional hub workshop alongside its annual Seattle Fusion Week conference. The event brought together fusion companies, researchers, economic development experts, federal and state government representatives, and power utilities from the western states of Washington, California, Colorado and Nevada. Attendees discussed the potential of regionally focused commercialization of fusion energy in three pillars: technology, workforce, and economic development. Mel Clark, President & CEO, CleanTech Alliance, and Dr. Javier Garay, Associate Dean for Research and Professor of Mechanical and Aerospace Engineering, at the University of California San Diego (UCSD) and Founding Director of the UCSD Fusion Engineering institute, are co-PIs for this project. The project is sponsored by the U.S. Department of Energy’s Office of Fusion Energy Sciences (FES) through a Field Work Proposal to Pacific Northwest National Laboratory (PNNL) with Karl Mueller as point-of-contact. Chris Ajemian (Principal, Ajemian Consulting, LLC) and Dr. Christopher Keane (Professor of Physics and former Vice-President for Research, Washington State University) co-organized the workshop and were the editors for this report. This report details the current state of the work of the four western states to develop industry-led collaboration with national laboratories, universities, and government at all levels to hasten the commercialization of fusion energy. It provides a summary of fusion energy R&D needs, presents the ideas the attendees at the workshop identified for deepening regional collaboration, and makes findings and recommendations for next steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Value of Nuclear Energy to the Reliability of the North American Power System: Results for Western and Eastern Interconnections

This report documents the fulfillment of a milestone for the United States (U.S.) Department of Energy Office of Nuclear Energy Light Water Reactor Sustainability Program: completing a baseline study of regional impact of nuclear power plants and hydrogen production in maintaining grid services and power quality. Models have been comprehensively demonstrated for the Western Interconnection, or Western Electric Coordinating Council area, and in the Eastern Interconnection for scenarios representative of past extreme events (e.g., drought and heat waves). Understanding the impact on the reliability of the bulk electric system of any reduction in generation capacity from nuclear power, for any reason, is the motivation of this work. Factors that might lead to the premature or unplanned closure of nuclear plants, extended outages, or repurposing of nuclear power include: • Aging infrastructure: Many nuclear power plants in the U.S. are nearing the end of their designed operating lives. Upgrading aging infrastructure can be expensive, and some utilities may choose to retire plants rather than invest in costly upgrades. • Low wholesale electricity prices: The deregulation of the electricity market in many states has led to increased competition and driven down wholesale electricity prices, causing nuclear power operators to seek other revenue sources for their heat and power such as clean hydrogen production. • Renewables growth: The rapid growth of renewable energy sources like solar and wind power is posing a challenge to traditional generation sources like nuclear. While many see renewables as a key part of the clean energy transition, their intermittent nature requires additional grid solutions for reliable power supply. • The potential for regulatory decisions to be in conflict: In its 2021 rulemaking, EPA rule (86 FR 880), the Environmental Protection Agency (EPA) set a compliance date for the ban on processing and distribution in commerce of Decabromodiphenyl Ether (DecaBDE). Since DecaBDE is in many components, particularly wiring, of nuclear power plants which are deemed safety-related or important to safety, three plants would not have been able to restart after their 2023 spring outages, and numerous others would have faced issues in the near future. Fortunately, in this case, the EPA provided relief to the nuclear energy industry. The report provides a summary of the significant role nuclear energy plays in the United States’ power generation mix, supplying around 20% of the nation’s electricity generation, spread across 28 U.S. states. Nuclear power is reliable, mostly unaffected by weather and seasonal changes, and provides a consistent source of baseload power. In terms of capacity, nuclear power plants account for as much as 26% of balancing area power generation capacity. Nuclear power also provides a substantial contribution (e.g., 10% of the inertia in the Eastern Interconnection) of the synchronous spinning mass/inertia that buffers the rate at which frequency changes when a load and generation imbalance occurs (e.g., a large plant trips or a load is suddenly shed due to a transmission outage). This contribution is critical for maintaining grid stability during sudden changes in load or generation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Conference Support, 32nd Western Photosynthesis Conference 2023

This DOE-BES award provided conference support for the 32nd Western Photosynthesis Conference (WPC2023), held January 5–8, 2023 at the Bodega Bay Marine Laboratory in Bodega Bay, California. The Western Photosynthesis Conference is one of three regional photosynthesis meetings held annually in the United States and serves as a primary venue for early-career scientists—graduate students, postdoctoral researchers, and undergraduates—to present research and build professional networks alongside established investigators in the field. Photosynthesis research is central to the DOE Office of Science's Basic Energy Sciences mission, underpinning fundamental understanding of solar energy conversion, biofuels, and the biological transformation of light into chemical energy. DOE-BES funds were used, as proposed, to support registration and housing costs for 20 early-career participants (9 postdoctoral researchers, 9 graduate students, and 2 undergraduates) and to help defray travel costs for two junior invited speakers based outside California, for a total DOE-BES expenditure of $10,060. The meeting was executed as planned, with no significant deviations from the approved program, budget, or schedule. WPC2023 drew 76 registrants across six scientific topic areas, featured 8 of 9 invited/keynote speakers, and provided extensive opportunities for early-career scientists to present talks and posters, compete for recognition awards, and network with senior researchers in the field.

conference↗

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid

This report presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗