Seeded FEL Amplifier-Buncher in the 0.5-9 THz for Advanced Accelerators

Longitudinal modulation of a relativistic electron beam in the THz range is important for advanced laser- or beam-driven plasma accelerators operating in the 10{sup 16}-10{sup 18} cm{sup -3} plasma density range. We describe a single-pass FEL amplifier-buncher which is under construction at the UCLA Neptune laboratory. Microbunching on the 0.5-3 THz frequency scale is achieved during the process of a resonant FEL interaction between an electron beam and a THz seed pulse. A narrow-band, low-power THz seed source based on the frequency mixing of CO{sub 2} laser lines in a GaAs nonlinear crystal is built and fully characterized. The THz radiation pulse generated by this source will be guided through a hollow waveguide inside the planar FEL undulator driven by a regular photoinjector. By using a time-dependent FEL code GENESIS 1.3, we optimized the undulator parameters and analyzed the dynamics of the modulated electron beam. At present, the THz FEL microbuncher is being built and we update the status of the project.

43 PARTICLE ACCELERATORS↗

Femtosecond Microbunching of Electron Beam in a 7{sup th} Harmonic Coupled IFEL

We report the results of studying electron beam microbunching in a 7{sup th} order IFEL interaction using coherent transition radiation emitted by the bunched beam as a diagnostic. The resonant wavelength for the undulator with a period of 3.3 cm and K = 1.8 is 74.2 {mu}m, but it was seeded by a CO{sub 2} laser with a seven times shorter wavelength of 10.6 {mu}m. The {approx}12.3 MeV electrons were efficiently bunched longitudinally inside a ten period long undulator producing the first, second, and third harmonics in a CTR spectrum. It is shown that in the case of approximately equal sizes of the electron and the seed radiation beams, the IFEL interaction results in transverse variation of bunching which significantly affects the CTR harmonic content. The measurements were compared to the predictions of IFEL simulations. These experimental results demonstrate for the first time feasibility of using very high order harmonic coupling for efficient IFEL/FEL interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Free-electron laser driven by the LBNL laser-plasma accelerator

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by a high-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source ({approx}10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (> or approx.10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10{sup 13} photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

43 PARTICLE ACCELERATORS↗

A Fourier transform spectrometer without a beam splitter for the vacuum ultraviolet range: From the optical design to the first UV spectrum

We describe a Fourier transform (FT) spectrometer designed to operate down to 60 nm (20 eV) on a synchrotron radiation beamline for high resolution absorption spectrometry. As far as we know, such an instrument is not available below 140 nm mainly because manufacturing accurate and efficient beam splitters remains a major problem at these wavelengths, especially if a wide bandwidth operation is desired. In order to overcome this difficulty, we developed an interferometer based on wave front division instead of amplitude division. It relies on a modified Fresnel bimirror configuration that requires only flat mirrors. The instrument provides path difference scanning through the translation of one reflector. During the scanning, the moving reflector is controlled by an optical system that keeps its direction constant within a tolerable value and provides an accurate interferometric measurement of the path difference variation. Therefore, a regular interferogram sampling is obtained, producing a nominal spectral impulse response and an accurate spectral calibration. The first results presented in this paper show a measured spectral resolution of {delta}{sigma}=0.33 cm{sup -1} (interval between spectral samples). This was obtained with a sampling interval of 29 nm (path difference) and 512 K samples from a one-sided interferogram using a cosine FT. Such a sampling interval should allow the recording of large bandwidth spectra down to {lambda}=58 nm with an ultimate resolving power of 500 000 at this wavelength. In order to check the instrument performances, we first recorded an interferogram from a He-Ne stabilized laser. This provided the actual spectral impulse function, which was found to be fully satisfactory. The determination of the impulse response distortion and of the noise on the vacuum ultraviolet (VUV) spectral range provided accurate information in the sampling error profile over a typical scan. Finally, the instrument has been moved to the SU5 undulator-based synchrotron radiation beamline (Super-ACO facility, LURE, Orsay, France). A high resolution spectrum of O{sub 2} (the Schumann-Runge absorption bands, 185-200 nm) was computed from recorded interferograms using the beamline monochromator at the zeroth order to feed the instrument with an 11% relative bandwidth ''white'' beam (2003). These UV measurements are very close to those found in the literature, showing nominal performances of the FT spectrometer that should translate into an unprecedented resolving power at shortest VUV wavelengths. A recent upgrade (2007) and future developments will be discussed in light of the current installation of the upgraded FT spectrometer as a permanent endstation for ultrahigh resolution absorption spectrometry on the VUV beamline DESIRS at SOLEIL, the new French third generation synchrotron facility.

43 PARTICLE ACCELERATORS↗

Advanced photoelectric effect experiment beamline at Elettra: A surface science laboratory coupled with Synchrotron Radiation

We report the main characteristics of the advanced photoelectric effect experiments beamline, operational at Elettra storage ring, featuring a fully independent double branch scheme obtained by the use of chicane undulators and able to keep polarization control in both linear and circular mode. The paper describes the novel technical solutions adopted, namely, (a) the design of a quasiperiodic undulator resulting in optimized suppression of higher harmonics over a large photon energy range (10-100 eV), (b) the thermal stability of optics under high heat load via cryocoolers, and (c) the end station interconnected setup allowing full access to off-beam and on-beam facilities and, at the same time, the integration of users' specialized sample growth chambers or modules.

43 PARTICLE ACCELERATORS↗

Beamline I11 at Diamond: A new instrument for high resolution powder diffraction

The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented. Using an in-vacuum undulator for photon production and deploying simple x-ray optics centered around a double-crystal monochromator and a pair of harmonic rejection mirrors, a high brightness and low bandpass x-ray beam is delivered at the sample. To provide fast data collection, 45 Si(111) analyzing crystals and detectors are installed onto a large and high precision diffractometer. High resolution powder diffraction data from standard reference materials of Si, {alpha}-quartz, and LaB{sub 6} are used to characterize instrumental performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method of determining narrow energy spread electron beams from a laser plasma wakefield accelerator using undulator radiation

In this paper a new method of determining the energy spread of a relativistic electron beam from a laser-driven plasma wakefield accelerator by measuring radiation from an undulator is presented. This could be used to determine the beam characteristics of multi-GeV accelerators where conventional spectrometers are very large and cumbersome. Simultaneous measurement of the energy spectra of electrons from the wakefield accelerator in the 55-70 MeV range and the radiation spectra in the wavelength range of 700-900 nm of synchrotron radiation emitted from a 50 period undulator confirm a narrow energy spread for electrons accelerated over the dephasing distance where beam loading leads to energy compression. Measured energy spreads of less than 1% indicates the potential of using a wakefield accelerator as a driver of future compact and brilliant ultrashort pulse synchrotron sources and free-electron lasers that require high peak brightness beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II

A novel variably polarized angle-resolved photoemission spectroscopy beamline in the vacuum-ultraviolet (VUV) region has been installed at the UVSOR-II 750 MeV synchrotron light source. The beamline is equipped with a 3 m long APPLE-II type undulator with horizontally/vertically linear and right/left circular polarizations, a 10 m Wadsworth type monochromator covering a photon energy range of 6-43 eV, and a 200 mm radius hemispherical photoelectron analyzer with an electron lens of a {+-}18 deg. acceptance angle. Due to the low emittance of the UVSOR-II storage ring, the light source is regarded as an entrance slit, and the undulator light is directly led to a grating by two plane mirrors in the monochromator while maintaining a balance between high-energy resolution and high photon flux. The energy resolving power (h{nu}/{Delta}h{nu}) and photon flux of the monochromator are typically 1x10{sup 4} and 10{sup 12} photons/s, respectively, with a 100 {mu}m exit slit. The beamline is used for angle-resolved photoemission spectroscopy with an energy resolution of a few meV covering the UV-to-VUV energy range.

43 PARTICLE ACCELERATORS↗

Calibration of a microchannel plate based extreme ultraviolet grazing incident spectrometer at the Advanced Light Source

We present the design and calibration of a microchannel plate based extreme ultraviolet spectrometer. Calibration was performed at the Advance Light Source (ALS) at the Lawrence Berkeley National Laboratory (LBNL). This spectrometer will be used to record the single shot spectrum of radiation emitted by the tapered hybrid undulator (THUNDER) undulator installed at the LOASIS GeV-class laser-plasma-accelerator. The spectrometer uses an aberration-corrected concave grating with 1200 lines/mm covering 11-62 nm and a microchannel plate detector with a CsI coated photocathode for increased quantum efficiency in the extreme ultraviolet. A touch screen interface controls the grating angle, aperture size, and placement of the detector in vacuum, allowing for high-resolution measurements over the entire spectral range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-performance soft x-ray spectromicroscopy beamline at SSRF

The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.

43 PARTICLE ACCELERATORS↗

Dynamical stability of electron trajectories in a free-electron laser with planar wiggler

The numerical computation of Kolmogorov entropy is used to study the dynamical stability of a free-electron laser with a planar wiggler. Axial magnetic field and ion-channel guiding are examined as two different types of focusing mechanism for confinement of the electron beam against its self-fields. It was found that the dynamical stability of electron trajectories decreases profoundly near the resonance region. Self-fields increase the dynamical stability in group I orbits and decrease it in group II orbits. These orbits are defined according to their axial magnetic field or ion-channel density.

43 PARTICLE ACCELERATORS↗

Generation of multi-color attosecond x-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable multi-color attosecond coherent x-ray radiation. This scheme uses a modulation compression method to generate a multi-spike prebunched kilo-ampere peak current electron beam from a few tens ampere electron beam out of a linac. Such a beam transporting through a series of undulator radiators and bunch compressors generates multi-color coherent x-ray radiation. As an illustration, we present an example to generate two attosecond pulses with 2.2 nm and 3 nm coherent x-ray radiation wavelength and more than 200 MW peak power using a 50 A 200 nm laser seeded electron beam.

43 PARTICLE ACCELERATORS↗

A tapered undulator experiment at the ELBE far infrared hybrid-resonator oscillator free electron laser

A tapered undulator experiment was carried out at the ELBE far-infrared free electron laser (FEL). The oscillator FEL makes use of a hybrid optical resonator. The main motivation was to see whether the presence of a dispersive medium in the form of a waveguide in the resonator has any effect on the outcome. The FEL saturated power and the wavelength shifts have been measured as a function of both positive as well as negative undulator field amplitude tapering. In contrast to the typical high-gain FELs where positive tapering proves beneficial for the output power we observed an improvement of performance at negative taper. During the same experiments we studied the characteristics of the detuning curves. The width of the curves indicates a maximum small signal gain for zero taper while the output peak power increases with negative taper. The saturated power output, the detuning curve characteristics, and the wavelength shifts agrees with the theoretical predictions. Details of the experiment are presented.

43 PARTICLE ACCELERATORS↗

Ultrahigh resolution soft x-ray emission spectrometer at BL07LSU in SPring-8

An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution {Delta}E < 100 meV and/or an E/{Delta}E{approx} 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 {mu}m) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/{Delta}E= 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.

43 PARTICLE ACCELERATORS↗

Experimental observation of helical microbunching of a relativistic electron beam

Experimental observation of the microbunching of a relativistic electron beam at the second harmonic interaction frequency of a helical undulator is presented. The microbunching signal is observed from the coherent transition radiation of the electron beam and indicates experimental evidence of a dominantly helical electron beam density distribution. This result is in agreement with theoretical and numerical predictions and provides a proof-of-principle demonstration of proposed schemes designed to generate light with orbital angular momentum in high-gain free-electron lasers.

43 PARTICLE ACCELERATORS↗

Hard x-ray or gamma ray laser by a dense electron beam

A dense electron beam propagating through a laser undulator can radiate a coherent x-ray or gamma ray. This lasing scheme is studied with the Landau damping theory. The analysis suggests that, with currently available physical parameters, coherent gamma rays of up to 50 keV can be generated. The electron quantum diffraction suppresses the free electron laser action, which limits the maximum radiation.

43 PARTICLE ACCELERATORS↗

Quick-scanning x-ray absorption spectroscopy system with a servo-motor-driven channel-cut monochromator with a temporal resolution of 10 ms

We have developed a quick-scanning x-ray absorption fine structure (QXAFS) system and installed it at the recently constructed synchrotron radiation beamline BL33XU at the SPring-8. Rapid acquisition of high-quality QXAFS data was realized by combining a servo-motor-driven Si channel-cut monochromator with a tapered undulator. Two tandemly aligned monochromators with channel-cut Si(111) and Si(220) crystals covered energy ranges of 4.0-28.2 keV and 6.6-46.0 keV, respectively. The system allows the users to adjust instantly the energy ranges of scans, the starting angles of oscillations, and the frequencies. The channel-cut crystals are cooled with liquid nitrogen to enable them to withstand the high heat load from the undulator radiation. Deformation of the reflecting planes is reduced by clamping each crystal with two cooling blocks. Performance tests at the Cu K-edge demonstrated sufficiently high data quality for x-ray absorption near-edge structure and extended x-ray absorption fine-structure analyses with temporal resolutions of up to 10 and 25 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Manufacturing of diamond windows for synchrotron radiation

A new diamond window construction is presented and explicit manufacturing details are given. This window will increase the power dissipation by about a factor of 4 over present day state of the art windows to absorb 600 W of power. This power will be generated by in-vacuum undulators with the storage ring ALBA operating at a design current of 400 mA. Extensive finite element (FE) calculations are included to predict the windows behavior accompanied by explanations for the chosen boundary conditions. A simple linear model was used to cross-check the FE calculations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗