Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volume of fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Assessment of Thermal Stratification in Versatile Test Reactor Transients

The Versatile Test Reactor (VTR) is a fast-spectrum test reactor currently being developed in the United States under the direction of the US Department of Energy. The conceptual design of the 300 MWth pool-type sodium-cooled fast reactor (SFR) has been led by the US National Laboratories in collaboration with General Electric-Hitachi and Bechtel National Inc. Safety performance analysis for the VTR conceptual design is being performed with the systems thermal-hydraulics (SYSTH) module of the SAS4A/SASSYS-1 liquid-metal reactor safety analysis code system. Since the current model of the VTR employs a simple perfect mixing model for large plena like the hot pool, it is not able to predict temperature variations that may develop during the transient. Prior work simulating the response of SFRs to postulated events like the Protected Station Blackout (PSBO) has shown that the phenomenon of thermal stratification, where stable thermal layers accumulate in the hot pool, may delay the transition to natural circulation and thus impact the predicted transient progression. Thus, an effort has begun to model this transient by integrating a Computational Fluid Dynamics (CFD) model of the hot pool into the SAS4A/SASSYS-1 model of the Primary Heat Transport System during the simulation of the PSBO event. A three-dimensional Volume-Of-Fluid CFD model of the VTR hot pool has been developed for the co-simulation of SAS4A/SASSYS-1 with CFD. In this work, the standalone SAS4A/SASSYS-1 calculation and the standalone CFD calculation based on the SAS4A/SASSYS-1 calculation result were produced on the Idaho National Laboratory High Performance Computing cluster, SAWTOOTH. At this time, only the standalone CFD and SAS4A/SASYS-1 simulation results are provided.

99 GENERAL AND MISCELLANEOUS↗

Venous Gas Embolism: Review to Quantify a Safe Volume of Air in Intravenous Fluids Bags for Spaceflight Applications

INTRODUCTION: The ability to create intravenous fluids (IVF) in-situ from the potable water supply of a spaceflight vehicle or habitat is a desired capability for an exploration medical system. In order to define an acceptable volume of air in IVF bags, an understanding of the volume of venous gas embolism as it relates to negative outcomes is needed. The purpose of this study is to review the literature to determine if there is a known volume of gas that contributes to mortality and/or morbidity that could be used to define requirements for rapid IVF infusion in microgravity. METHODS: A literature review was conducted of the PubMed database using the syntax: (Venous) AND (Gas OR Air) AND (Embolism) AND (Morbidity) AND (Mortality) AND (Volume) as well as manual review of references from relevant articles. 151 articles were screened excluding partial text and pediatric articles. Studies were reviewed for identification of volume of venous gas embolism associated with morbidity and/or mortality, which identified 27 articles. RESULTS: Reviewed literature included animal studies, case reports, and review articles. A high variation of proposed volumes contributing to mortality was reported. The limited human data values ranged from 20 ml to 200 ml of infused air with mortality estimated to be 48 – 80%. No studies evaluated human morbidity in any capacity. DISCUSSION: The lack of consensus on the safe volume of infused air has potential ramifications for IVF use in spaceflight as current technologies to create IVF from potable water may introduce air in IVF bags. While current microgravity infusion protocols call for the use of inline air removal filters, commercially available options have flow rate limitations that preclude rapid infusion in a resuscitation scenario. Such filters may be used in parallel to increase flow rate, but the time required to set up such a system may exclude its use during a medical emergency. Additionally, these consumable filters drive up the overall mass and volume of the medical system. Identification of a safe volume of air in IVF would allow for guidelines for the in-situ production of IVF in future spaceflight vehicles/habitats.

Christopher R Woodard↗

Soft phonon theorems

A variety of condensed matter systems describe gapless modes that can be interpreted as Nambu-Goldstone bosons of spontaneously broken Poincaré symmetry. In this paper we derive new soft theorems constraining the tree-level scattering of these degrees of freedom, as exhibited in solids, fluids, superfluids, and framids. These soft theorems are in one-to-one correspondence with various broken symmetries, including spacetime translations, Lorentz boosts, and, for the case of fluids, volume-preserving diffeomorphisms. We also implement a bootstrap in which the enhanced vanishing of amplitudes in the soft limit is taken as an input, thus sculpting out a subclass of exceptional solid, fluid, and framid theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

Characterizing Droplet Formation from Non-Linear Slosh in a Propellant Tank

The Fluid Dynamics Branch (ER42) at the Marshall Space Flight Center (MSFC) was tasked with characterizing the formation and evolution of liquid droplets resulting from nonlinear propellant slosh in a storage tank. Lateral excitation of propellant tanks can produce high amplitude nonlinear slosh waves through large amplitude excitations and or excitation frequencies near a resonance frequency of the tank. The high amplitude slosh waves become breaking waves upon attaining a certain amplitude or encountering a contracting geometry such as the upper dome section of a spherical tank. Inherent perturbations in the thinning regions of breaking waves result in alternating regions of high and low pressure within the fluid. Droplets form once the force from the local pressure differential becomes larger than the force maintaining the fluid interface shape due to surface tension. Droplets released from breaking waves in a pressurized tank may lead to ullage collapse given the appropriate conditions due to the increased liquid surface area and thus heat transfer between the fluids. The goal of this project is to create an engineering model that describes droplet formation as a function of propellant slosh for use in the evaluation of ullage collapse during a sloshing event. The Volume of Fluid (VOF) model in the production level Computational Fluid Dynamics (CFD) code Loci-Stream was used to predict droplet formation from breaking waves with realistic surface tension characteristics. Various excitation frequencies and amplitudes were investigated at multiple fill levels for a single storage tank to create the engineering model of droplet formation from lateral propellant slosh.

Brodnick, Jacob↗

Non-Diffusive Volume Advection with A High Order Interface Reconstruction Method

We show that non-diffusive volume advection in two-dimensions is achieved with several benchmark problems using a newly developed high-order volume of fluids (VOF) interface reconstruction method. (1) A new VOF interface reconstruction method using circular/corner facets (linear facets are a degenerate case of arcs). We create a circular interface facet in each mixed zone by matching neighbor volume with a hybrid Newton’s-bisection method and the local solution is final. In the general case, the new VOF interface reconstruction has 3rd order accuracy and can be easily made seamless. The new method addresses intrinsic issues with Young’s method such as gaps between interface facets in the case of a curved interface, and inability to define curvature nor identify corners. (2) A non-diffusive volume advection scheme. In an ALE advection step, a well-defined interface can be carried over through a Lagrange step and used to compute volume distribution into a relaxed mesh. Then, an interface reconstruction step is performed to redefine the interface in the relaxed mesh. We must point out that the interface carried over is also a solution of interface reconstruction because all the volume fractions in the relaxed mesh are naturally matched. We provide an interface tracking method compatible with our reconstruction scheme, where it is granted to use the prior info as an initial guess to capture sub-mesh resolution features. As a result, we are able to treat multiple facets inside a single mixed cell and obtain highly accurate, non-diffusive solution for advection problems with rather coarse meshes. We show our solutions for two-dimensional incompressible flows with two materials with a) the X + O diagonal translation; b) the Zalesak rotational test; and c) the single vortex spiral test.

97 MATHEMATICS AND COMPUTING↗

CFD Modeling of Phase Change and Pressure Drop during Violent Sloshing of Cryogenic Fluid in a Small-Scale Tank

This paper presents the development of a two-phase CFD model that is used to study sloshing of a cryogenic fluid (LN2) undergoing phase change generated by lateral acceleration and its effects on the ensuing heat and mass transfer and pressure drop in a small-scale tank. In this model the interface is captured using the volume-of-fluid (VOF) method [1]. Kinetic-theory based Schrage relation [2] is used for calculating phase change mass transfer at the liquid-vapor interface. Computational results are compared to the data provided by a non-isothermal sloshing experiment with phase change conducted by the University of Tokyo and JAXA in 2018 using liquid Nitrogen in a transparent tank. The effect of different thicknesses of a liquid temperature stratification layer created at the interface on the pressure drop during sloshing was studied experimentally. CFD results for interface movement and tank pressure are presented and compared in this paper to experimental data for the cases with the smallest and largest liquid temperature stratification thickness.

phase change↗

Numerical Analysis of Cavitation-Induced Two-Phase Fluid Transients in Cryogenic Feedlines Using Finite Volume Procedure

This article presents a numerical investigation of the cavitation induced fluid transient in cryogenic feedline due to sudden closure of the valve A one dimensional numerical model based on finite volume procedure consisting of nodes and branches using Generalized Fluid System Simulation Program ( has been employed for the prediction of pressure variations The unsteady friction formulation accurately determines wall shear stress, and a homogeneous mixture model is used for two phase flow modeling Numerical results obtained with the present formulation are compared with experimental results and Method of Characteristic ( based results It is observed that low residual in flow variable calculation improves the solution providing numerically stable results GFSSP is able to reproduce the fluid transient peak due to vapor collapse Subsequently, it can retain the shape of pressure wave for two phase fluid transients, but it is dampening faster compared to experiments Further investigation is required with set of experiments to validate the present numerical approach for different experimental data.

Fluid Transient↗

Modeling Self-Pressurization and Spray Bar Pressure Control of a Cryogenic Storage Tank in Normal Gravity

This paper presents Computational Fluid Dynamics (CFD) models for simulating self-pressurization and spray bar cooling processes in a large-scale liquid hydrogen storage tank under normal gravity. The self-pressurization model utilizes the kinetics-based Schrage equation with the Volume-Of-Fluid (VOF) model to account for the evaporative and condensing interfacial mass fluxes. It uses a laminar approach to model natural convection and compares the pressures and temperatures predicted by the CFD model with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) self-pressurization experiment. Additionally, the predicted interfacial mass flux is presented. A CFD model for simulating pressure control using a spray bar is also presented. An Eulerian-Lagrangian approach models the interactions between the discrete droplets and the continuous ullage phase. The spray model is coupled with the VOF model by tracking particles in the ullage, removing particles from the ullage when they reach the interface, and then adding their contributions to the liquid. The T-sat model is used to calculate the droplet-ullage heat and mass transfer. In this model, droplets warm up to the saturation temperature corresponding to the ullage vapor pressure thereafter evaporating while remaining at the saturation temperature. The tank pressure, vapor, and liquid temperature evolutions are validated against data from the MHTB spray bar mixing experiment.

Self-Pressurization↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, where droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Computational Fluid Dynamics↗

Modeling Self-Pressurization and Spray Bar Pressure Control of A Cryogenic Storage Tank in Normal Gravity

This paper presents computational fluid dynamics (CFD) models for simulating self-pressurization and spray-bar pressure control processes in a large-scale liquid hydrogen storage tank under normal gravity conditions. For self-pressurization, the model employs the kinetics-based Schrage equation alongside the volume-of-fluid (VOF) method to account for interfacial mass transfer. The CFD predictions of pressure and temperature are compared with experimental data from the Multipurpose Hydrogen Test Bed (MHTB) experiment, and the predicted interfacial mass transfer rates are also presented. A CFD model simulating pressure control using a spray bar has also been developed. An Eulerian-Lagrangian approach models the interactions between discrete droplets and the continuous ullage (vapor) phase. The spray model is coupled with the VOF method by tracking droplets in the ullage and removing them when they reach the liquid interface. The T-sat model calculates droplet-ullage heat and mass transfer, wherein droplets warm up to the saturation temperature corresponding to the ullage vapor pressure before evaporating while remaining at the saturation temperature. The evolution of tank pressure, vapor temperature, and liquid temperature predicted by the CFD model is validated against data from the MHTB spray-bar mixing experiment. Overall, the CFD models agree with experimental data, demonstrating their capability to simulate self-pressurization and pressure control processes in large-scale cryogenic storage tanks. These models can be valuable tools for designing and optimizing cryogenic fluid management systems in future applications.

Self-Pressurization↗

Flow boiling in geometrically modified microchannels

Microchannels are a promising solution for high-heat-flux thermal management scenarios, including high-performance microelectronics cooling and power electronics cooling. However, thermohydraulic instabilities result from the rapid vapor bubble formation. The prior literature has examined several methods, including constricted inlet microchannels, expanding microchannels, and auxiliary jetting microchannels, to mitigate the effect of these instabilities. Computational fluid dynamics and heat transfer (CFD/HT) modeling of the flow boiling phenomena in these microchannel configurations has seen limited examination, and one-to-one numerical comparisons of the different mitigation strategies have not been performed. In the present investigation, CFD/HT analyses using a three-dimensional (3D) volume of fluid model coupled with a phase-change model for the interfacial heat and mass transfer were performed for multiple microchannel configurations (constricted inlet, expanding, and auxiliary jetting microchannels). A benchmark case of a rectangular microchannel was examined to quantify baseline thermohydraulic performance. Results demonstrated slight to significant thermal performance improvements for all cases, and significant pressure benefits for the expanding and jetting cases, consistent with experimental results in the literature. Bubble dynamics and visualization for the baseline and alternative configurations are provided to give insight into their underlying physics, and the differences in performance were investigated and compared with available literature.

Broughton, Justin (ORCID:000000026848457X)↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

Characterization of Slosh Damping for Ortho-Grid and Iso-Grid Internal Tank Structures

Grid stiffened tank structures such as Ortho-Grid and Iso-Grid are widely used in cryogenic tanks for providing stiffening to the tank while reducing mass, compared to tank walls of constant cross-section. If the structure is internal to the tank, it will positively affect the fluid dynamic behavior of the liquid propellant, in regard to fluid slosh damping. As NASA and commercial companies endeavor to explore the solar system, vehicles will by necessity become more mass efficient, and design margin will be reduced where possible. Therefore, if the damping characteristics of the Ortho-Grid and Iso-Grid structure is understood, their positive damping effect can be taken into account in the systems design process. Historically, damping by internal structures has been characterized by rules of thumb and for Ortho-Grid, empirical design tools intended for slosh baffles of much larger cross-section have been used. There is little or no information available to characterize the slosh behavior of Iso-Grid internal structure. Therefore, to take advantage of these structures for their positive damping effects, there is much need for obtaining additional data and tools to characterize them. Recently, the NASA Marshall Space Flight Center conducted both sub-scale testing and computational fluid dynamics (CFD) simulations of slosh damping for Ortho-Grid and Iso-Grid tanks for cylindrical tanks containing water. Enhanced grid meshing techniques were applied to the geometrically detailed and complex Ortho-Grid and Iso-Grid structures. The Loci-STREAM CFD program with the Volume of Fluid Method module for tracking and locating the water-air fluid interface was used to conduct the simulations. The CFD simulations were validated with the test data and new empirical models for predicting damping and frequency of Ortho-Grid and Iso-Grid structures were generated.

Douglas G. Westra↗

Cardiovascular and Body Fluid Adjustments During Bed Rest and Space Flight

Although a few scientific bed rest (BR) studies were conducted soon after World War II, advent of the space program provided impetus for utilizing prolonged (days-months) BR, which employed the horizontal or 6 degree head-down tilt (HDT) body positions, to simulate responses of healthy people to microgravity. Shorter (hours) HDT protocols were used to study initial mechanisms of the acclimation-deconditioning (reduction of physical fitness) syndromes. Of the major physiological factors modified during BR, reduced force on bones, ligaments, and muscles, and greatly reduced hydrostatic pressure within the cardiovascular system, the latter: which involves shifts of blood from the lower extremities into the upper body, increase in central venous pressure, and diuresis, appears to be the initial stimulus for acclimation. Increase in central venous pressure occurs in subjects during weightless parabolic flight, but not in astronauts early during orbital flight. But significant reduction in total body water (hypohydration) and plasma volume (hypovolemia) occurs in subjects during both BR and microgravity. Response of interstitial fluid volume is not as clear, It has been reported to increase during BR, and it may have increased in Skylab II and IV astronauts. Reduction of total body water, and greater proportional reduction of extracellular volume, indicates increased cellular volume which may contribute to inflight cephalic edema. Cerebral pressure abates after a few days of HDT, but not during flight. accompanied by normal (eugravity) blood constituent concentrations suggesting some degree of acclimation had occurred. But during reentry, with moderately increased +Gz (head-to-foot) acceleration and gravitational force, the microgravity "euhydration" becomes functional progressive dehydration contributing to the general reentry syndrome (GRS) which, upon landing the Shuttle, can and often results in gastrointestinal distress, disorientation, vertigo, fatigue, and fainting. Various pre-reentry hyperhydration procedures have been utilized to counteract the GRS. Thus, the somewhat decreased central venous pressure and lack of diuresis early in spaceflight suggests mechanisms other than the Gauer-Henry reflex are more important for maintaining fluid volume homeostasis in astronauts. Inflight hypohydration and hypovolemia are more important for maintaining fluid volume homeostasis in astronauts.

Greenleaf, John E.↗

Fluid and protein shifts after postural changes in humans

The effects of head-up, one-step, slow-graded, and rapid-graded tilt positions on blood density (BD), plasma density (PD), and erythrocyte density (ED) in male and female subjects are evaluated using a mass density detection method. The preparation of the samples and procedures for density and hematocrit measurements are described. The formula for calculating the density and volume of fluid shifted between intravascular and extravascular compartments is derived. The data reveal that ED does not change with varying tilt positions; however, PD and BD increase linearly with increasing angles of tilt, thereby resembling the time course of hemodilution and hemoconcentration.

Hinghofer-Szalkay, H.↗

Microburst modelling and scaling

A microburst can be modeled by releasing a volume of fluid that is slightly heavier than the ambient fluid, allowing it to fall onto a horizontal surface. Vorticity develops on the sides of this parcel as it descends and causes it to roll up into a turbulent vortex ring which impinges on the ground. Such a model exhibits many of the features of naturally occurring microbursts which are a hazard to aviation. In this paper this model is achieved experimentally by releasing a volume of salt water into fresh water from a cylindrical dispenser. When care is taken with the release the spreading rate of the surface outflow is measurable and quite repeatable despite the fact that the flow is turbulent. An elementary numerical approximation to this model, based on inviscid vortex dynamics, has also been developed. A scaling law is proposed which allows experiments with different fluid densities to be compared with each other and with the numerical results. More importantly the scaling law makes it possible to compare the model results with real microbursts.

Lundgren, T. S.↗

A Volume Flux Approach to Cryolava Dome Emplacement on Europa

We previously modeled a subset of domes on Europa with morphologies consistent with emplacement by viscous extrusions of cryolava. These models assumed instantaneous emplacement of a fixed volume of fluid onto the surface, followed by relaxation to form domes. However, this approach only allowed for the investigation of late-stage eruptive processes far from the vent and provided little insight into how cryolavas arrived at the surface. Consideration of dome emplacement as cryolavas erupt at the surface is therefore pertinent. A volume flux approach, in which lava erupts from the vent at a constant rate, was successfully applied to the formation of steep-sided volcanic domes on Venus. These domes are believed to have formed in the same manner as candi-date cryolava domes on Europa. In order to gain a more complete understanding of the potential for the emplacement of Europa domes via extrusive volcanism, we have applied this new volume flux approach to the formation of putative cryovolcanic domes on Europa. Assuming as in that europan cryolavas are briny, aqueous solutions which may or may not contain some ice crystal fraction, we present the results of this modeling and explore theories for the formation of low-albedo moats that surround some domes.

Cryolava Dome Emplacement↗