Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Validate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Validation of an integrated modeling framework for investigating 3D plasma responses in tokamak plasmas

As contemporary experimental tokamaks are pushed toward reactor-relevant operation, they provide essential testbeds for demonstrating and exploring ELM control strategies for deployment in future fusion pilot plants. Accurate predictions of full plasma responses are essential to guide and optimize these demonstrations. This paper introduces and validates an integrated modeling framework over a historical range of DIII-D operational space. The integrated modeling framework uses only scalar plasma parameters and optional reference boundary to self-consistently and flexibly scan through tokamak operational space and estimate the corresponding ELM-suppression relevant plasma response over 3D coil phase space. The framework generates tightly converged equilibria that satisfy a target set of plasma parameters (I p , β N , l i ), with kinetic profiles constrained by an EPED(NN)-computed pedestal and empirical core model. The plasma response of these modeled equilibria is calculated with GPEC. Validated against 55 distinct DIII-D equilibria, the framework consistently reproduces experimentally constrained equilibrium pressure, q, and other representative profiles using the time-varying information from only evolving scalar plasma parameters; plasma response validation is performed for the n=3 perturbation. In particular, the plasma response of a DIII-D discharge scanning q 95 in search of ELM suppression windows is quantitatively reproduced. By accurately reproducing experimental equilibria and plasma responses across wide parameter variation, the framework supports potential for synthetic parameter scans in key operational, stability, and plasma response dimensions to investigate RMP ELM-suppression experiments and inform predictive RMP scenario optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Validation of Control Bands Using Bayesian Statistical Analyses

Abstract This study presents a quantitative validation of 15 Similar Exposure Groups (SEGs) that were derived via control bands inherent to the Risk Level Based Management System currently being used at the Lawrence Livermore National Laboratory. For 93% of the SEGs that were evaluated, statistical analyses of personal exposure monitoring data, through Bayesian Decision Analysis (BDA), demonstrated that the controls implemented from the initial control bands assigned to these SEGs were at least as protective as the controls from the control band outcomes derived from the quantitative data. The BDA also demonstrated that for 40% of the SEGs, the controls from the initial control bands were overly protective, thus allowing controls to be downgraded, which resulted in a significant saving of environmental safety and health (ES&H) resources. Therefore, as a means to both confirm existing controls and to identify candidate SEGs for downgrading controls, efforts to continuously improve the accuracy of Control Banding (CB) strategies through the routine quantitative validation of SEGs are strongly encouraged. Targeted collaborative efforts across institutions and even countries for both the development of CB strategies and the validation of discreetly defined SEGs of commonly performed tasks will not only optimize limited ES&H resources but will also assist in providing a simplified process for essential risk communication at the worker level to the benefit of billions of workers around the world.

McCord, Tyler A.↗

Validation of selection function, sample contamination and mass calibration in galaxy cluster samples

ABSTRACT We construct and validate the selection function of the MARD-Y3 galaxy cluster sample. This sample was selected through optical follow-up of the 2nd ROSAT faint source catalogue with Dark Energy Survey year 3 data. The selection function is modelled by combining an empirically constructed X-ray selection function with an incompleteness model for the optical follow-up. We validate the joint selection function by testing the consistency of the constraints on the X-ray flux–mass and richness–mass scaling relation parameters derived from different sources of mass information: (1) cross-calibration using South Pole Telescope Sunyaev-Zel'dovich (SPT-SZ) clusters, (2) calibration using number counts in X-ray, in optical and in both X-ray and optical while marginalizing over cosmological parameters, and (3) other published analyses. We find that the constraints on the scaling relation from the number counts and SPT-SZ cross-calibration agree, indicating that our modelling of the selection function is adequate. Furthermore, we apply a largely cosmology independent method to validate selection functions via the computation of the probability of finding each cluster in the SPT-SZ sample in the MARD-Y3 sample and vice versa. This test reveals no clear evidence for MARD-Y3 contamination, SPT-SZ incompleteness or outlier fraction. Finally, we discuss the prospects of the techniques presented here to limit systematic selection effects in future cluster cosmological studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation of the DESI DR2 Ly⁢ 𝛼 BAO analysis using synthetic datasets

The second data release (DR2) of the Dark Energy Spectroscopic Instrument (DESI), containing data from the first three years of observations, doubles the number of Lyman-α (Ly α) forest spectra in DR1 and it provides the largest dataset of its kind. To ensure a robust validation of the baryonic acoustic oscillation (BAO) analysis using Ly α forests, we have made significant updates compared to DR1 to both the mocks and the analysis framework used in the validation. In particular, we present CoLoRe-QL, a new set of Lyα mocks that use a quasilinear input power spectrum to incorporate the nonlinear broadening of the BAO peak. Here, we have also increased the number of realizations used in the validation to 400, compared to the 150 realizations used in DR1. Finally, we present a detailed study of the impact of quasar redshift errors on the BAO measurement, and we compare different strategies to mask damped Lyman-α absorbers in our spectra. The BAO measurement from the Ly α dataset of DESI DR2 is presented in a companion publication.

Casas, L. [Institut de Física d’Altes Energies (IF↗

Multifidelity validation of digital surrogates using variable-density turbulent mixing models

In this study, ensembles of experimental data are presented and utilized to compare and validate two models used in the simulation of variable-density (Atwood = 0.22), compressible turbulent mixing. Though models of this kind (Reynolds averaged NavierStokes and large-eddy simulations) have been validated extensively with more canonical flows in previous studies, here the present approach offers novelty in the complexity of the geometry, the ensemble-based validation, and the uniformity of the computational framework on which the models are tested. Moreover, all experimental and computational tasks were completed by the authors which has led to a tightly coupled experimental configuration with its “digital twin.” The experimental divergent-shock-tube facility and its data acquisition methods are described and replicated in simulation space. A 2D Euler model which neglects the turbulent mixing at the interface is optimized to experimental data using a Gaussian process. This model then serves as the basis for both the 2D RANS and 3D LES studies that make comparisons to the mixing-layer data from the experiment. A relatively simple RANS model is shown to produce good agreement with experimental data only at late flow development times. The LES ensembles generally show good agreement with experimental data but display sensitivity to the characterization of initial conditions. Resolution-dependent behavior is also observed for certain higher-order statistics of interest. Overall, the LES model successfully captures the effects of divergent geometry, compressibility, and combined nonlinear instabilities inherent to the problem. The successful prediction of mixing width and its growth rate highlight the existence of three distinct regimes in the development of the instability, each with similarities to previously studied instabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic study of the validity of the eikonal model including uncertainties

Nuclear reactions at intermediate beam energies are often interpreted using the eikonal model. In the analysis of complex reaction probes, where few-body reaction methods are needed, the eikonal method may be used as an efficient way for describing the fragment-target reaction process. In this work, we perform a systematic study to test the validity of the eikonal approximation for nucleon-nucleus reactions. We also quantify uncertainties due to the nucleon optical potential on reaction observables. We inspect the validity of the eikonal model and its semiclassical correction by comparing it to exact solutions (obtained from solving the optical-model equation with a finite-differences method) for a wide range of reactions. We also study the effect of relativistic corrections, both kinematic and dynamic, by effectively incorporating the relativistic effects at intermediate energies. The uncertainties from a Bayesian global optical potential (KDUQ) are propagated to the observables of interest. Our study includes neutron and proton reactions on 27 Al , 40 Ca , 90 Zr , and 208 Pb , for a wide range of energies 𝐸 lab = 0–400 MeV. We calculate neutron-total cross sections (elastic and reactions) as well as proton-absorption cross sections as a function of beam energy, using the eikonal model, the eikonal model with a semiclassical correction, and the exact solution. Here, we also compute angular distributions for the methods above. Our results show that for the proton-absorption cross section, the eikonal model can be used down to around 60 MeV and the semiclassical correction extends its use to 30 MeV. However, the validity of the eikonal model for the neutron-total cross section only goes down to ≈120 MeV, a range extended to ≈ 50 MeV when using the semiclassical correction. We find the semiclassical correction to the eikonal model to be less effective in describing the angular distributions. The 1⁢𝜎 uncertainty intervals on the observables we studied is less than 5% for most of the energies considered, but increases rapidly for higher energies, namely energies outside the range of KDUQ (𝐸 lab > 200MeV).

Cluster models↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Towards Validation of Advanced Accelerated Stress Testing Protocols through Failure Analysis and Materials Characterization

As the lifetime of photovoltaic modules increases toward the goal of 50 years, accelerated stress testing is critical to assessing the viability of newer, improved, and often cheaper materials in the field. However, the validation of accelerated testing to reproduce field failure has remained elusive. The recent developments of more advanced stress testing protocols utilizing sequential and combined stressors have provided another opportunity for validation. Using a suite of mechanical, chemical, and structural characterization methods we report the development of our approach using a known bad backsheet “AAA.” We then apply this approach to PVDF-based backsheets to further confirm the generalizability of this approach. The outcome of this work is two-fold: (1) validation of advanced accelerated testing protocols which will enable the prediction of field failures in new materials, and (2) deeper insights into the degradation mechanisms observed through the extensive characterization allowing for improved materials engineering and development.

accelerated aging↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗

Challenges and opportunities in verification and validation of low temperature plasma simulations and experiments

This paper describes the verification and validation (V&V) framework developed for the stochastic Particle-in-Cell, Direct Simulation Monte Carlo code Aleph. An ideal framework for V&V from the viewpoint of the authors is described where a physics problem is defined, and relevant physics models and parameters to the defined problem are assessed and captured in a Phenomena Identification and Ranking Table (PIRT). Furthermore, numerous V&V examples guided by the PIRT for a simple gas discharge are shown to demonstrate the V&V process applied to a real-world simulation tool with the overall goal to demonstrably increase the confidence in the results for the simulation tool and its predictive capability. Although many examples are provided here to demonstrate elements of the framework, the primary goal of this work is to introduce this framework and not to provide a fully complete implementation, which would be a much longer document. Comparisons and contrasts are made to more usual approaches to V&V, and techniques new to the low-temperature plasma community are introduced. Specific challenges relating to the sufficiency of available data (e.g., cross sections), the limits of ad hoc validation approaches, the additional difficulty of utilizing a stochastic simulation tool, and the extreme cost of formal validation are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Visual Analytic Platform for Interactive Validation of Human Mobility Simulations

Human mobility insights guide domain experts in an array of decisions, including critical infrastructure design, disaster response, epidemic modeling, national security, and policy making. Due to the inherent noise and privacy concerns in real-world individual-level mobility data, it is often preferred to leverage simulators that generate synthetic mobility data instead. However, it is critical to inspect and validate the output of such simulators to ensure the synthetic data is aligned with the characteristics of the population and the area of interest known to domain experts. While there exist many quantitative approaches for validating synthetic data, we argue it is also important to also validate such data qualitatively to capture aspects that are known to domain experts but difficult to quantify. In this work, we demonstrate a visual analytic platform that empowers domain experts to interact with their simulation outputs along spatial and temporal dimensions. By augmenting automated techniques and human skills, our visual analytic platform is a step towards interactive capabilities for model steering and quality control of mobility simulators.

Monadjemi, Shayan↗

Challenging Practices of Algebraic Battery Life Models through Statistical Validation and Model Identification via Machine-Learning

Various modeling techniques are used to predict the capacity fade of Li-ion batteries. Algebraic reduced-order models, which are inherently interpretable and computationally fast, are ideal for use in battery controllers, technoeconomic models, and multi-objective optimizations. For Li-ion batteries with graphite anodes, solid-electrolyte-interphase (SEI) growth on the graphite surface dominates fade. This fade is often modeled using physically informed equations, such as square-root of time for predicting solvent-diffusion limited SEI growth, and Arrhenius and Tafel-like equations predicting the temperature and state-of-charge rate dependencies. In some cases, completely empirical relationships are proposed. However, statistical validation is rarely conducted to evaluate model optimality, and only a handful of possible models are usually investigated. This article demonstrates a novel procedure for automatically identifying reduced-order degradation models from millions of algorithmically generated equations via bi-level optimization and symbolic regression. Identified models are statistically validated using cross-validation, sensitivity analysis, and uncertainty quantification via bootstrapping. On a LiFePO 4 /Graphite cell calendar aging data set, automatically identified models utilizing square-root, power law, stretched exponential, and sigmoidal functions result in greater accuracy and lower uncertainty than models identified by human experts, and demonstrate that previously known physical relationships can be empirically "rediscovered" using machine learning.

25 ENERGY STORAGE↗

Sockeye Validation Support Using the SPHERE Facility

The engineering-scale heat pipe application Sockeye, being developed through the Nuclear En- ergy Advanced Modeling and Simulation program is concurrently undergoing code development and verification and validation activities. The Single Primary Heat Extraction and Removal Emu- lator (SPHERE) facility at Idaho National Laboratory has performed numerous sodium heat pipe experiments, one of which is modeled in this work to support Sockeye validation. Heat pipe data produced by the SPHERE facility was found to be very useful not only for Sockeye validation but also as a useful resource for model development. A Sockeye simulation performed using Sockeye’s conduction model modeled an experimental run at SPHERE and was found to be able to accurately reproduce the steady temperature distribution but revealed discrepancies in transient behavior after shutoff of the power. This effort also revealed a number of challenges of modeling an experimental setup such as SPHERE, for example, the importance of details in the setup such as possible gaps in insulation. Also, continuous collaboration between Sockeye developers and SPHERE experimentalists has been established, which allows future experiments to be refined in response to questions and challenges found by simulating earlier experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Caribbean deepwater snappers: Application of the bomb radiocarbon age estimation validation in understanding aspects of ecology and life history

Reef fishes have been utilized as food fish throughout the U.S. Caribbean and Gulf of Mexico waters for centuries, with increasing fishing effort in recent decades. As a result, many species have experienced declines in landings, including deepwater snappers such as queen snapper Etelis oculatus and blackfin snapper Lutjanus buccanella . However, little to no peer-reviewed published research exists on basic life history parameters for either species. Confirming the accuracy of an age estimation method for a fish species is essential for ensuring sustainable fisheries management. This is because in the assessment of fisheries species population age-based parameters, including longevity, age at sexual maturity, growth rate, mortality, age-specific reproductive output, and lifetime reproductive output, are important in understanding overall life history strategies of managed stocks. The past stock assessment on U.S. Caribbean queen snapper utilized an estimated longevity of 8 y, derived from length frequencies for fish from St. Lucia. Blackfin snapper has an estimated longevity of 27 y based on a relatively small study from offshore waters of the southeastern U.S. The focus of our investigation was to estimate maximum longevity of two data-poor species in the U.S. Caribbean. The accuracy of ageing methods was tested via bomb radiocarbon age estimation validation and effects of depth on Δ 14 C in otolith cores and eye lens core values were examined. Results from our work indicate a maximum validated age of 45 y for queen snapper, and 43 y for blackfin snapper. Our findings indicate queen snapper and blackfin snapper are long-lived (> 40 y). The resulting Δ 14 C comparison between eye lens cores and otolith cores has important implications for the study of age validation, specifically when deepwater species are involved.

59 BASIC BIOLOGICAL SCIENCES↗

Validation and Recalibration of the Solubility Models in Support of the Heater Test in Salt Formations

The US Department of Energy Office of Nuclear Energy is conducting a brine availability heater test to characterize the thermal, mechanical, hydrological and chemical response of salt at elevated temperatures. In the heater test, brines will be collected and analyzed for chemical compositions. In order to support the geochemical modeling of chemical evolutions of the brines during the heater test, we are recalibrating and validating the solubility models for the mineral constituents in salt formations up to 100°C, based on the solubility data in multiple component systems as well as simple systems from literature. In this work, we systematically compare the model-predicted values based on the various solubility models related to the constituents of salt formations, with the experimental data. As halite is the dominant constituent in salt formations, we first test the halite solubility model in the Na-Mg-Cl dominated brines. We find the existing halite solubility model systematically over-predict the solubility of halite. We recalibrate the halite model, which can reproduce halite solubilities in Na-Mg-Cl dominated brines well. As gypsum/anhydrite in salt formations controls the sulfate concentrations in associated brines, we test the gypsum solubility model in NaCl solutions up to 5.87 mol•kg –1 from 25 ° C to 50 ° C. The testing shows that the current gypsum solubility model reproduces the experimental data well when NaCl concentrations are less than 1 mol•kg –1 . However, at NaCl concentrations higher than 1, the model systematically overpredicts the solubility of gypsum. In the Na + —Cl – —SO 4 2– —CO 3 2– system, the validation tests up to 100 ° C demonstrate that the model excellently reproduces the experimental data for the solution compositions equilibrated with one single phase such as halite (NaCl) or thenardite (Na 2 SO 4 ), with deviations equal to, or less than, 1.5 %. The model is much less ideal in reproducing the compositions in equilibrium with the assemblages of halite + thenardite, and of halite + thermonatrite (Na 2 CO 3 •H 2 O), with deviations up to 31 %. The high deviations from the experimental data for the multiple assemblages in this system at elevated temperatures may be attributed to the facts that the database has the Pitzer interaction parameters for Cl – —CO 3 2– and SO 4 2– —CO 3 2– only at 25 ° C. Finally, in the Na + —Ca 2+ —SO 4 2– —HCO 3 – system, the validation tests also demonstrate that the model reproduces the equilibrium compositions for one single phase such as gypsum better than the assemblages of more than one phase.

36 MATERIALS SCIENCE↗

Validation of Fault Displacements from Dynamic Rupture Simulations against the Observations from the 1992 Landers Earthquake

ABSTRACT Coseismic fault displacements in large earthquakes have caused significant damage to structures and lifelines on and near fault lines. Coseismic displacements represent a real threat, especially to distributed infrastructure systems. For infrastructure systems that can not avoid active faults, engineering displacement demands are defined using probabilistic fault-displacement hazard analyses (PFDHA). However, PFDHA models are sparse and poorly constrained partly due to the scarcity of detailed fault-displacement observations. Advancements in dynamic rupture simulation methods make them an attractive approach to address this important issue. Because fault displacements can be simulated for various geologic conditions as constrained by current knowledge about earthquake processes, they can be used to supplement the observation datasets. In addition to providing on-fault displacements, when used with appropriate constitutive models for the bulk medium, they can capture off-fault distributed inelastic deformations as well. For viable extrapolation, simulations must first be validated against data. In this article, we summarize the calibration and validation of the dynamic rupture model against the observations of the well-documented 1992 Landers earthquake. We defined a preferred model that reproduces several first-order fault-displacement metrics such as the on-fault partition of the total displacement, the mean fault-zone width, and the location of the peak displacement. Simulated ground motions consistent with the observations ensure that all physics important to modeling have been properly parameterized. For the extrapolation, we generated a suite of dynamic rupture models to quantify expected fault-displacement metrics, their intercorrelations, and magnitude dependencies, which are in part supported by the Landers and other recent earthquakes. Our validation and extrapolation exercise paves the way for using dynamic rupture modeling to quantitatively address fault-displacement hazard on a broader scale. The results are promising and are expected to be useful to inform PFDHA model development.

Geochemistry & Geophysics↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗