Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Closing the Gap Between Experiment and Theory: Reactive Scattering of HCl from Au(111)

Accurate simulation of molecules reacting on metal surfaces, which can help in improving heterogeneous catalysts, remains out of reach for several reactions. For example, a large disagreement between theory and experiment for HCl reacting on Au(111) still remains, despite many efforts. In this work, the dissociative chemisorption of HCl on Au(111) is investigated with a recently developed MGGA density functional (MS-RPBEl) and a high-dimensional neural network potential. Additionally, previous experimental sticking probabilities are re-examined. A considerably improved agreement between experiment and theory is obtained, although theory still overestimates experimental sticking probabilities by a factor of 2-7 at the highest incidence energy. Computed and measured vibrational transition probabilities are also in improved agreement. Several dynamical effects such as angular steering and energy transfer from the molecule to the surface are found to play an important role.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared Signatures for Phase Identification in Hafnium Oxide Thin Films

Phase identification in HfO 2 -based thin films is a prerequisite to understanding the mechanisms stabilizing the ferroelectric phase in these materials, which hold great promise in next-generation non-volatile memory and computing technology. While grazing-incidence X-ray diffraction is commonly employed for this purpose, it has difficulty unambiguously differentiating between the ferroelectric phase and other metastable phases that may exist due to similarities in the d-spacings, their low intensities, and the overlapping of reflections. Infrared signatures provide an alternative route. However, their use in phase identification remains limited because phase control has overwhelmingly been accomplished via substituents, thereby convoluting infrared signatures between the substituent and the phase changes they induce. Herein, we report the infrared optical responses of three undoped hafnium oxide films where annealing conditions have been used to create films consisting primarily of the ferroelectric polar orthorhombic Pca2 1 , antipolar orthorhombic Pbca, and monoclinic P2 1 /c phases, as was confirmed via transmission electron microscopy (TEM), UVvisible optical properties, and electrical property measurements. Vibrational signatures acquired from synchrotron nano-Fourier transform infrared spectroscopy (nano-FTIR) are shown to be capable of differentiating between the phases in a non-destructive, rapid, and nanoscale manner. The utility of nano-FTIR is illustrated for a film exhibiting an antiferroelectric polarization response. In this sample, it is proven that this behavior results from the Pbca phase rather than the often-cited tetragonal phase. Here, by demonstrating that IRspectroscopy can unambiguously distinguish phases in this material, this work establishes a tool needed to isolate the factors dictating ferroelectric phase stability in HfO 2 -based materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Methodology for the Characterisation of Air-coupled Ultrasound Probes

This study is aimed at developing a technique for the characterisation of air-coupled ultrasound probes, starting from the analysis of the mechanical behaviour of the probe membrane. The vibratory behaviour of the emission membrane is studied using laser-Doppler vibrometry techniques with high frequency demodulation system (20 MHz). The determination of the vibration provides information which are useful for the assessment of the performance of the probe, in particular concerning the Quality factor and the portion of the membrane which really contributes to the emission. During the second step the results of the vibration measurements are used to calculate, by means of numerical boundary element method, the ultrasound beam emitted in terms of intensity in space. The obtained field is compared with the direct measurements carried out by scanning with the receiver probe and a pinhole plate. This comparison allows the potential and the problems of the two different characterisation techniques to be determined, even if the pinhole technique (which is currently considered the state of the art) cannot be used as an absolute reference. This study appears to be useful for paving the way for a new methodology for the calibration of air-coupled ultrasound probes, which potentially could be used not only to improve the probe manufacturing process, but also to control conformity to specifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical phonon modes in Al{sub 1−x}Sc{sub x}N

Optical phonons are measured to probe the origins of the reported anomalously high piezoelectric response in aluminum scandium nitride (Al{sub 1−x}Sc{sub x}N). Epitaxial layers with 0 ≤ x ≤ 0.16 deposited on sapphire(0001) exhibit a refractive index below the band gap, which increases from 2.03 for x = 0 to 2.16 for x = 0.16, corresponding to a dielectric constant ε{sub ∞} = 4.15 + 3.2x. Raman scattering shows that zone-center E{sub 2}(H) and A{sub 1}(TO) phonon modes shift to lower frequencies with increasing x, following linear relationships: ω(E{sub 2}(H)) = 658–233x (cm{sup −1}) and ω(A{sub 1}(TO)) = 612–159x (cm{sup −1}). Similarly, zone-center E{sub 1}(TO) and A{sub 1}(LO) phonon mode frequencies obtained from specular polarized infrared reflectance measurements red-shift to ω(E{sub 1}(TO)) = 681–209x (cm{sup −1}) and ω(A{sub 1}(LO)) = 868–306x (cm{sup −1}). The measured bond angle decreases linearly from 108.2° to 106.0°, while the length of the two metal-nitrogen bonds increase by 3.2% and 2.6%, as x increases from 0 to 0.16. This is associated with a 3%–8% increase in the Born effective charge and a simultaneous 6% decrease in the covalent metal-N bond strength, as determined from the measured vibrational frequencies described with a Valence-Coulomb-Force-Field model. The overall results indicate that bonding in Al-rich Al{sub 1−x}Sc{sub x}N qualitatively follows the trends expected from mixing wurtzite AlN with metastable hexagonal ScN. However, extrapolation suggests non-linear composition dependencies in bond angle, length, and character for x ≥ 0.2, leading to a structural instability that may be responsible for the reported steep increase in the piezoelectric response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical coherence tomography (OCT) leading to more insight into cochlear mechanics

Optical Coherence Tomography (OCT) was used to measure vibrations of the basilar membrane (BM) and the Reticular Lamina (RL) in the cochlea of the guinea pig, at frequencies up to 25 kHz. Because of the difficulty of the experiments the data have limited sets of parameters and are subject to high noise levels. In a viable guinea-pig cochlea, the RL moves in the region of maximum response with a larger amplitude than the BM. We cannot rule out that some of that difference is due to a geometrical factor. We also found a consistent increase of this amplitude difference with frequency, which points to a low-pass filtering process. That process might be linked to the mass of the fluid contained in the Organ of Corti channel (OoC channel)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural, morphological and optical properties of CeO{sub 2} thin films deposited by RF sputtering

Cerium oxide (CeO{sub 2}) thin films were deposited on glass substrates by sputtering at various substrate temperatures. CeO{sub 2} films were characterized by X-ray diffraction, FESEM, PL and Raman analyses. X-ray diffraction patterns of films reveal fcc cubic structure with preferential orientation along (2 2 0) crystallographic plane. SEM images show that the particles are uniformly distributed on the film surface. The films were found to be well adheared to the substrates and pin holes are not observed on the surface of the films. PL spectra exhibits a strong near band-gap-edge emission and a broad blue, green luminescence, which can be assigned to the presence of Ce and O vacancies, amorphous phases, deep level impurities and structural defects. The relative intensity between the different peaks of the bands related to defects or impurities was studied as a tool for quality control of the films. Moreover, vibrational measurements through Raman analysis were carried out and the results are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy improvement in a calibration test bench for accelerometers by a vision system

A procedure is described in this paper for the accuracy improvement of calibration of low-cost accelerometers in a prototype rotary test bench, driven by a brushless servo-motor and operating in a low frequency range of vibrations (0 to 5 Hz). Vibration measurements by a vision system based on a low frequency camera have been carried out, in order to reduce the uncertainty of the real acceleration evaluation at the installation point of the sensor to be calibrated. A preliminary test device has been realized and operated in order to evaluate the metrological performances of the vision system, showing a satisfactory behavior if the uncertainty measurement is taken into account. A combination of suitable settings of the control parameters of the motion control system and of the information gained by the vision system allowed to fit the information about the reference acceleration at the installation point to the needs of the procedure for static and dynamic calibration of three-axis accelerometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatiotemporal dispersion compensation for a 200-THz noncollinear optical parametric amplifier

A noncollinear optical parametric amplifier (NOPA) can produce few-cycle femtosecond laser pulses that are ideally suited for time-resolved optical spectroscopy measurements. However, the nonlinear-optical process giving rise to ultrabroadband pulses is susceptible to spatiotemporal dispersion problems. Here, we detail refinements, including chirped-pulse amplification (CPA) and pulse-front matching (PFM), that minimize spatiotemporal dispersion and thereby improve the properties of ultrabroadband pulses produced by a NOPA. Here, the description includes a rationale behind the choices of optical and optomechanical components, as well as assessment protocols. We demonstrate these techniques using a 1 kHz, second-harmonic Ti:sapphire pump configuration, which produces ~5-fs duration pulses that span from about 500 to 800 nm with a bandwidth of about 200 THz. To demonstrate the utility of the CPA-PFM-NOPA, we measure vibrational quantum beats in the transient–absorption spectrum of methylene blue, a dye molecule that serves as a reference standard.

47 OTHER INSTRUMENTATION↗

Initial Fulcher band observations from high resolution spectroscopy in the MAST-U divertor

High resolution D$^*_2$ Fulcher band spectroscopy was used in the MAST-U divertors during Super-X and (shorter-legged) elongated divertor density ramps with D 2 fuelling from the mid-plane high-field side. In the Super-X case, the upper divertor showed ground state rotational temperatures of the D 2 molecules increasing from ~6000 K, starting at the detachment onset, to ~9000 K during deepening detachment. This was correlated with the movement of the Fulcher emission region towards the X-point, which is in turn correlated with the movement of the ionisation source. The increase in rotational temperature occurred throughout the divertor except near the divertor entrance, where ionisation was still the dominant process. Qualitative agreement was obtained between the lower and upper divertor. Similar rotational temperatures were obtained in the elongated divertor before the detachment onset, although the increase in rotational temperature during detachment was less clearly observed as less deep detachment was obtained. The measured vibrational distribution of the upper Fulcher state does not agree with a ground state Boltzmann distribution but shows a characteristically elevated population in the ν = 2 and ν = 3 bands in particular; which is strongly correlated to the rotational temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating two-photon double ionization of D{sub 2} by XUV-pump-XUV-probe experiments

We used a split-mirror setup attached to a reaction microscope at the free-electron laser in Hamburg (FLASH) to perform an XUV-pump-XUV-probe experiment by tracing the ultrafast nuclear wave-packet motion in the D{sub 2}{sup +}(1s{sigma}{sub g}) with <10 fs time resolution. Comparison with time-dependent calculations shows excellent agreement with the measured vibrational period of 22{+-}4 fs in D{sub 2}{sup +}, points to the importance of accurately knowing the internuclear distance-dependent ionization probability, and paves the way to control sequential and nonsequential two-photon double-ionization contributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analyzing data from a PDV microphone

Photon Doppler Velocimetry (PDV) is used at Los Alamos National Laboratory to measure extremely fast velocities (on the order of 0.01 - 5 km/s) of projectiles during material testing procedures. This kind of testing is extremely important to understand how materials behave in extreme conditions (such as in nuclear explosions). PDV data is created by summing an incident beam with a Doppler shifted reflection, forming a beat frequency. The beat frequency is directly proportional to the velocity of the reflecting surface. We explored a new way of using PDV: measuring slow velocities (less than 1 m/s). The principle method we used was to measure vibrations in a Mylar sheet due to incident sound waves. I analyzed these files using both my own coding as well as a program designed at NSTec for this purpose. Analysis included performing Fourier Transforms, extracting velocity as a function of time, and playing the velocity function through a speaker to recreate the initial sound. We were able to create a successful microphone, though playback quality was poor. The limiting factor was the low velocity of the Mylar sheet, which was about 0.2 m/s. Other methods are now being explored to extract velocity data in a more efficient manner. During this project I gained extensive experience in programming, data analysis, problem solving, and communication. I learned that one must be creative in order to solve complex problems, approaching them from various angles. I also gained a lot of practice working on a team, which consisted of a high school student, another college intern, and our mentor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Matrix Infrared Spectroscopic and Computational Investigations of Novel Small Uranium Containing Molecules - Final Technical Report

Direct reactions of f-element uranium, thorium and lanthanide metal atoms were investigated with small molecules. These metal atoms were generated by laser ablation and mixed with the reagent molecules then condensed with noble gases at 4K. The products were analyzed by absorption of infrared light to measure vibrational frequencies which were confirmed by quantum chemical calculations. We have learned more about the reactivity of uranium atoms with common molecules, which will aid in the develolpment of further applications of uranium.

Andrews, Lester↗

Gear Test Assembly - Report on Experimental Testing (FY2020)

The Gear Test Assembly (GTA) has completed Campaign #2 of in-sodium testing at the Mechanisms Engineering Test Loop (METL). Campaign #1 was conducted in 2019 and completed 19,600 cycles, correlating to 9,800 fuel assembly maneuvers. Campaign #1 was terminated following a shaft seizure caused by a failed bearing in the sodium gearbox. Campaign #2 was conducted in the spring of 2020 and completed 2,768 cycles, correlating to 1,384 fuel assembly maneuvers. Campaign #2 was terminated following elevated vibration measurements coming from the sodium gearbox. Following cleaning and disassembly, a bearing was found to have failed in the sodium gearbox. Campaign #1 used tapered roller bearings made of 52100 steel with a heat treatment from the manufacturer that allows for operation to 350°C. Campaign #2 used the same tapered roller bearings, but with no heat treatment. A new dynamic shaft seal design was used in Campaign #2 that led to significant reductions in argon consumption and graphite debris generation. A modified external gearbox system led to no external bearing failures and allowed for higher torque output. Finally, modifications to the Carbonation System led to a more effective carbonation process and all-around reduction in turnaround time.

42 ENGINEERING↗

A Heterogeneous System for Eagle Detection, Deterrent, and Wildlife Collision Detection for Wind Turbines (Final Technical Report)

This report summarizes the design, implementation, and test of an integrated system for automated detection and deterrence of eagles, with included wind turbine blade strike detection and imaging functionality. A machine learning approach was used in conjunction with a 360° camera system for automated detection and classification of golden eagles. This was developed using footage obtained from trained golden eagles and other raptors, in collaboration with wildlife biologists and professional bird handlers. Oregon State University developed a visual deterrent system, which uses inflatable anthropomorphic sculptures with random, kinetic motion to deter eagles, and conducted limited field testing on live eagles; the deterrent can be triggered by the visual detection of eagles using the vision system. Finally, a multi-sensor module was developed that is mounted at the turbine blade root. This module measures vibration and other motions to detect blade strikes, and an integrated on-blade camera captures an image of any impacting objects. Long-term, this blade strike detection system is intended to support an automatic monitoring and certification system for the eagle detection and deterent system. Independent field testing of each system component is described. Testing of the integrated system on an operational wind turbine was conducted across three separate field tests. This includes multi-day fields tests on a General Electric 1.5MW wind turbine at the National Renewable Energy Laboratory (NREL) National Wind Technology Center (NWTC) in Boulder, CO in October 2018 and July 2019; installation procedures, test procedures, and a summary of collected data are presented. A third multi-day on-turbine field test is also presented, which was performed using a General Electric 1.5MW wind turbine at the North American Wind Research and Training Center (NAWRTC) at Mesalands Community College, Tucumcari, NM in April 2019. Across these field tests, the vision system was demonstrated using unmanned aerial vehicles (UAV), and the eagle classification algorithm was not tested; the visual deterrent system was demonstrated, including automatic, remote deployment following surrogate visual detections; and, multi-sensor on-blade data was recorded across multiple wind turbine operational conditions and through more than 100 surrogate blade strikes using soft projectiles, including the successful demonstration of automatic image capture of striking objects. This data set was also used for offline development and validation of enhanced collision detection algorithms. As summarized in this report, the development and field validation of an integrated detection, deterrent, and blade collision detection system represents a critical proof of concept for future technology development of related detection and deterrent technologies, where both deterrent as well as collision detection recording devices are needed for future siting, monitoring, and operation of wind turbine installations, both onshore and offshore.

17 WIND ENERGY↗