Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VAPORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Identifying Controlling Variables for Mercury Vapors in Alpha-4 at Y-12: Two Year Data Collection Update

Multiple sensor packages were deployed at Alpha-4 by SRNL, in collaboration with United Cleanup Oak Ridge LLC (UCOR), to monitor mercury vapor concentrations and meteorological parameters. These sensors collected data, inside and outside of the legacy-use facility, for approximately two years. Though data gaps still exist, particularly in colder months, several controlling variables were identified that govern mercury vapor concentrations within Alpha-4. Temperature, barometric pressure gradients, humidity, and wind speed have been identified as controlling variables. A strong positive correlation was seen between mercury vapor concentrations and temperature which generally followed diurnal fluctuations. Temperatures below approximately 10 degrees Celsius did not show any spikes above the PEL, indicating more work can be performed at any time during the winter months – more data should be collected to confirm consistency in this finding. Additionally, spikes in mercury vapor concentrations above that of the permissible exposure limit (PEL; 100 µg/m 3 ) occurred primarily in late afternoon or evening/overnight hours (between 3 PM and 6 AM), which suggests D&D operations might be best scheduled during morning or daytime hours prior to the late afternoon. However, a limited number of spikes did occur outside of the identified window, although this may be attributed to disturbances in air flow and mercury vapor release from work activities performed inside of the Alpha-4 building. The analysis conducted allows for a strong predictive capability for estimating mercury vapor concentrations based upon accurate meteorological parameters. Still, additional data collection, particularly in the winter months, could help to strengthen the predictive power and validate the identified data trends. Further, increased temporal resolution could also help to better characterize the incipient stages of the increases and decreases in the mercury vapor concentration. Continued monitoring support by SRNL at Y-12 is underway at Alpha-4 to further close remaining data gaps and support deactivation and decommissioning work. Within a collaborative effort with UCOR, the SRNL team is collecting mercury vapor data to study the efficacy of a novel mercury suppressant, FerroBlack® which was recently deployed at Alpha-4. In addition, modifications to the current monitoring setup to increase measurement resolution is also being investigated.

54 ENVIRONMENTAL SCIENCES↗

High-resolution mass spectrometric analysis of biomass pyrolysis vapors

Vapors generated from the pyrolysis of lignocellulosic biomass are made up of a complex mixture of oxygenated compounds. Direct analysis of these vapors provides insight into the mechanisms of depolymerization of cellulose, hemicellulose, and lignin as well as insight into reactions that may occur during condensation of pyrolysis vapors into bio-oil. Studies utilizing pyrolysis molecular beam mass spectrometry have provided valuable information regarding the chemical composition of pyrolysis vapors. Mass spectrometers generally employed with these instruments have low mass resolution of approximately a mass unit. The presence of chemical species with identical unit mass but differing elemental formulas cannot be resolved with these instruments and are therefore detected as a single ion. In this study we analyzed the pyrolysis vapors of several biomass sources using a high-resolution double focusing mass spectrometer. High-resolution analysis of pyrolysis vapors allowed for speciation of several compounds that would be detected as a single ion with unit mass resolution. Lastly, these data not only provide greater detail into the composition of pyrolysis vapors but also highlight differences between vapors generated from multiple biomass feedstocks.

09 BIOMASS FUELS↗

Anisotropic Vapor-Deposited Glasses: Hybrid Organic Solids

CONSPECTUS: The term "organic solids" encompasses both crystals and glasses. Organic crystals are commonly grown for purification and structure determination and are being extensively explored for applications in organic electronics including field effect transistors. The ability to control the packing of one molecule relative to its neighbors is of critical importance for most uses of organic crystals. Often, anisotropic packing is also highly desirable as it enhances charge transport and optimizes light absorption/emission. When compared to crystals, the local packing in organic glasses is highly disordered and often isotropic. Glasses, however, offer two key advantages with respect to crystals. First, glasses typically lack grain boundaries and thus exhibit better macroscopic homogeneity. Second, glass composition can often be varied over a wide range while maintaining homogeneity. Besides electronic materials, many modern plastics used in a wide range of technologies are organic glasses, and the glassy state is being increasingly utilized to deliver pharmaceuticals because of higher bioavailability. In this article, we introduce vapor-deposited organic glasses as hybrid materials that combine some of the useful features of crystals and traditional liquid-cooled glasses. Physical vapor deposition produces glasses by directly condensing molecules from the gas phase onto a temperature-controlled substrate and allows film thickness to be controlled with nanometer precision. Just as liquid-cooled glasses, vapor-deposited glasses have smooth surfaces and lack grain boundaries. These attributes are critical for applications such as organic light emitting diodes (OLEDs), in which vapor-deposited glasses of organic semiconductors form the active layers. In common with crystals, vapor-deposited glasses can exhibit anisotropic packing, and the extent of anisotropy can be comparable to that of the typical organic crystal. For vapor-deposited glasses, in contrast to crystals, anisotropic packing can generally be controlled as a continuous variable. Deposition conditions can be chosen to produce glasses with significant molecular orientation (molecules "standing up" or "lying down" relative to the substrate), and pr-stacking can be directed along different directions relative to the substrate. Over the last five years, we have gained a fundamental understanding of the mechanism that controls the anisotropy of vapor-deposited glasses and learned how to control many aspects of anisotropic packing. Two key elements that enable such control are the high mobility present at the surface of an organic glass and the tendency of the surface to promote anisotropic packing of molecules. In contrast to traditional epitaxial growth, for vapor-deposited glasses, the free surface (not the substrate) acts as a template that controls the structure of a growing film. Lastly, the structure of any given layer is decoupled from those beneath it, thereby providing considerable freedom in producing layered glassy structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shock Vaporization of Silica and the Thermodynamics of Planetary Impact Events

The most energetic planetary collisions attain shock pressures that result in abundant melting and vaporization. Accurate predictions of the extent of melting and vaporization require knowledge of vast regions of the phase diagrams of the constituent materials. To reach the liquid-vapor phase boundary of silica, we conducted uniaxial shock-and-release experiments, where quartz was shocked to a state sufficient to initiate vaporization upon isentropic decompression (hundreds of GPa). The apparent temperature of the decompressing fluid was measured with a streaked optical pyrometer, and the bulk density was inferred by stagnation onto a standard window. To interpret the observed post-shock temperatures, we developed a model for the apparent temperature of a material isentropically decompressing through the liquid-vapor coexistence region. Using published thermodynamic data, we revised the liquid-vapor boundary for silica and calculated the entropy on the quartz Hugoniot. The silica post-shock temperature measurements, up to entropies beyond the critical point, are in excellent qualitative agreement with the predictions from the decompressing two-phase mixture model. Furthermore, shock-and-release experiments provide an accurate measurement of the temperature on the phase boundary for entropies below the critical point, with increasing uncertainties near and above the critical point entropy. Our new criteria for shock-induced vaporization of quartz are much lower than previous estimates, primarily because of the revised entropy on the Hugoniot. As the thermodynamics of other silicates are expected to be similar to quartz, vaporization is a significant process during high-velocity planetary collisions.

36 MATERIALS SCIENCE↗

Diffuse scattering from the liquid-vapor interfaces of dilute Bi:Ga, Tl:Ga, and Pb:Ga alloys

As part of a study of the in-plane wave-vector (q{sub xy}) dependence of the effective Hamiltonian for the liquid-vapor interface, H(q), the wave-vector dependences of diffuse x-ray scattering from the liquid-vapor interfaces of dilute alloys of Bi in Ga, Tl in Ga, and Pb in Ga have been measured. In these dilute alloys the solute component segregates as a monolayer that forms the outermost stratum of the liquid-vapor interfaces, and the density distribution along the normal to the interface is stratified. Over the temperature ranges that the alloy interfaces were studied, the Tl and Pb monolayers exhibit both crystalline and liquid phases while the Bi monolayer is always liquid. The diffuse scattering from the liquid-vapor interfaces of these alloys displays interesting differences with that from the liquid-vapor interface of pure Ga. The presence of a segregated monolayer of solute in the liquid-vapor interface of the alloy appears to slightly suppress the fluctuations in an intermediate wave-vector range in a fashion that preserves the validity of the macroscopic capillary wave model to smaller wavelengths than in pure liquid Ga, and there is an increase in diffuse scattering when the Tl and Pb monolayers melt. The surface intrinsic roughness from fitting the wave-vector dependence of surface tension is 5.0 pm for the Tl:Ga alloy and 1.4 pm for the Bi:Ga alloy. Also, a mode of excitation that contributes to diffuse scattering from the liquid-vapor interface of Pb in Ga, but does not contribute to diffuse scattering from the liquid-vapor interface of Ga, has been identified. It is proposed that this mode corresponds to the separation of the Pb and Ga layers in the regime 1 nm{sup -1} {le} q{sub xy} {le} 10 nm{sup -1}.

36 MATERIALS SCIENCE↗

Experimental and Numerical Investigation of Flow Boiling in Additive Manufactured Foam Structures With Vapor Pathways

Abstract The unique properties of metal foams make them potential candidates for a range of applications, including microsystem thermal management. Using additive manufacturing to create foam-type structures can improve upon prior thermal solutions by eliminating thermal interface materials and allowing for customization/local control of parameters. In the present investigation, flow boiling in additive-manufactured metal foams is investigated both experimentally and numerically. Two test samples, one with uniform structure and the other with pathways for vapor removal, are compared both experimentally and numerically. A conjugate computational fluid dynamics and heat transfer (CFD-HT) model utilizing a three-dimensional volume of fluid (VOF) model with accompanying evaporation/condensation model provided in-depth visualization of the boiling flow phenomena. The experiments generated the thermohydraulic performance over a range of heat fluxes, demonstrating that the sample incorporating dedicated vapor pathways performed better in both pressure and heat transfer performance metrics compared to the uniform foam. Additionally, negative system-level effects (i.e., hydraulic oscillations) were shown to be abated using the vapor removal structures. The numerical model yielded further insight into the factors contributing to the improved performance. Results indicated the pathways functioned as vapor removal channels, allowing the generated vapor to vent from the foam structure into the lanes. Further computational investigations demonstrated changes in flow regimes, where the addition of vapor channels caused the flow to change from churn to annular. Bubble behavior unique to the vapor pathway structure was studied, showing stagnant regions that eject vapor into the channel.

Engineering↗

Detection and variability of combustion-derived vapor in an urban basin

Abstract. Water emitted during combustion may comprise a significant portion of ambient humidity (> 10 %) in urban areas, where combustion emissions are strongly focused in space and time. Stable water vapor isotopes can be used to apportion measured humidity values between atmospherically transported and combustion-derived water vapor, as combustion-derived vapor possesses an unusually negative deuterium excess value (d-excess, d = δ 2 H − 8 δ 18 O). We investigated the relationship between the d-excess of atmospheric vapor, ambient CO 2 concentrations, and atmospheric stability across four winters in Salt Lake City, Utah. We found a robust inverse relationship between CO 2 excess above background and d-excess on sub-diurnal to seasonal timescales, which was most prominent during periods of strong atmospheric stability that occur during Salt Lake City winter. Using a Keeling-style mixing model approach, and assuming a molar ratio of H 2 O to CO 2 in emissions of 1.5, we estimated the d-excess of combustion-derived vapor in Salt Lake City to be −179 ± 17 ‰, consistent with the upper limit of theoretical estimates. Based on this estimate, we calculate that vapor from fossil fuel combustion often represents 5–10 % of total urban humidity, with a maximum estimate of 16.7 %, consistent with prior estimates for Salt Lake City. Moreover, our analysis highlights that changes in the observed d-excess during periods of high atmospheric stability cannot be explained without a vapor source possessing a strongly negative d-excess value. Further refinements in this humidity apportionment method, most notably empirical validation of the d-excess of combustion vapor or improvements in the estimation of the background d-excess value in the absence of combustion, can yield more certain estimates of the impacts of fossil fuel combustion on urban humidity and meteorology.

54 ENVIRONMENTAL SCIENCES↗

Free-jet expansions from laser-vaporized planar surfaces

Characteristics of free-jet vapor expansions created by the pulsed-laser vaporization of some refractory materials are examined. Such expansions were generated from planar surfaces at laser power densities up to 2.5 MW/sq cm. Time-integrated and time-resolved photography were used to show that the structure and pressures of such flows are correlated by the same relationship that is valid for free jets from orifice flows. Data show that the vapor velocity becomes sonic at or very near the vaporizing surface. A method is presented for deriving vaporization pressure from flow-field photos; such pressures from carbon-vaporization data for temperatures to 4500 K are in good agreement with extrapolated equilibrium vapor pressures. It is shown that this technique may be a means to determine vapor pressures of refractory materials at high temperatures.

Covington, M. A.↗

A passive microwave technique for profiling of atmospheric water vapor

There is considerable interest in remote measurements of the vertical distribution of water vapor, particularly under cloud conditions. The net integrated amount of water vapor has been measured using the 22.235-GHz water vapor line (Staelin et al., 1975). Attempts to use this line for obtaining vertical distribution information have not been fruitful because of the weakness of absorption even at line center. The 183.310-GHz line is much stronger and thus provides a possibility of profiling water vapor. The paper presents a preliminary analysis of this possibility. A technique is described for retrieval of water vapor profiles from microwave radiometric measurements near the 183-GHz water vapor line, and weighting functions useful in the retrievals are developed. The results suggest that microwave radiometry near the 183-GHz water vapor line could yield interesting water vapor profiles, at least over oceans.

Schaerer, G.↗

Fatigue crack growth in 7475-T651 aluminum alloy plate in hard vacuum and water vapor

Compact specimens of 25 mm thick aluminum alloy plate were subjected to constant amplitude fatigue testing at a load ratio of 0.2. Crack growth rates were determined at frequencies of 1 Hz and 10 Hz in hard vacuum and laboratory air, and in mixtures of water vapor and nitrogen at water vapor partial pressures ranging from 94 Pa to 3.8 kPa. A significant effect of water vapor on fatigue crack growth rates was observed at the lowest water vapor pressure tested. Crack rates changed little for pressures up to 1.03 kPa, but abruptly accelerated at higher pressures. At low stress intensity factor ranges, cracking rates at the lowest and highest water vapor pressure tested were, respectively, two and five times higher than rates in vacuum. Although a frequency was observed in laboratory air, cracking rates in water vapor and vacuum are insensitive to a ten-fold change in frequency. Surfaces of specimens tested in water vapor and vacuum exhibited different amounts of residual deformation. Reduced deformation on the fracture surfaces of the specimens tested in water vapor suggests embrittlement of the plastic zone ahead of the crack tip as a result of environmental interaction.

Dicus, D. L.↗

The effect of tropospheric fluctuations on the accuracy of water vapor radiometry

Line-of-sight path delay calibration accuracies of 1 mm are needed to improve both angular and Doppler tracking capabilities. Fluctuations in the refractivity of tropospheric water vapor limit the present accuracies to about 1 nrad for the angular position and to a delay rate of 3x10(exp -13) sec/sec over a 100-sec time interval for Doppler tracking. This article describes progress in evaluating the limitations of the technique of water vapor radiometry at the 1-mm level. The two effects evaluated here are: (1) errors arising from tip-curve calibration of WVR's in the presence of tropospheric fluctuations and (2) errors due to the use of nonzero beamwidths for water vapor radiometer (WVR) horns. The error caused by tropospheric water vapor fluctuations during instrument calibration from a single tip curve is 0.26 percent in the estimated gain for a tip-curve duration of several minutes or less. This gain error causes a 3-mm bias and a 1-mm scale factor error in the estimated path delay at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor column density present in the troposphere during the astrometric observation. The error caused by WVR beam averaging of tropospheric fluctuations is 3 mm at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor (and is proportionally higher for higher water vapor content) for current WVR beamwidths (full width at half maximum of approximately 6 deg). This is a stochastic error (which cannot be calibrated) and which can be reduced to about half of its instantaneous value by time averaging the radio signal over several minutes. The results presented here suggest two improvements to WVR design: first, the gain of the instruments should be stabilized to 4 parts in 10(exp 4) over a calibration period lasting 5 hours, and second, the WVR antenna beamwidth should be reduced to about 0.2 deg. This will reduce the error induced by water vapor fluctuations in the estimated path delays to less than 1 mm for the elevation range from zenith to 6 deg for most observation weather conditions.

Wilcox, J. Z.↗

Buoyancy-Driven Heat Transfer During Application of a Thermal Gradient for the Study of Vapor Deposition at Low Pressure Using and Ideal Gas

A mathematical model has been developed to determine heat transfer during vapor deposition of source materials under a variety of orientations relative to gravitational accelerations. The model demonstrates that convection can occur at total pressures as low as 10-2 mm Hg. Through numerical computation, using physical material parameters of air, a series of time steps demonstrates the development of flow and temperature profiles during the course of vapor deposition. These computations show that in unit gravity vapor deposition occurs by transport through a fairly complicated circulating flow pattern when applying heat to the bottom of the vessel with parallel orientation with respect to the gravity vector. The model material parameters for air predict the effect of kinematic viscosity to be of the same order as thermal diffusivity, which is the case for Prandtl number approx. 1 fluids. Qualitative agreement between experiment and the model indicates that 6-(2-methyl-4-nitroanilino)-2,4-hexadiyn-l-ol (DAMNA) at these pressures indeed approximates an ideal gas at the experiment temperatures, and may validate the use of air physical constants. It is apparent that complicated nonuniform temperature distribution in the vapor could dramatically affect the homogeneity, orientation, and quality of deposited films. The experimental test i's a qualitative comparison of film thickness using ultraviolet-visible spectroscopy on films generated in appropriately oriented vapor deposition cells. In the case where heating of the reaction vessel occurs from the top, deposition of vapor does not normally occur by convection due to a stable stratified medium. When vapor deposition occurs in vessels heated at the bottom, but oriented relative to the gravity vector between these two extremes, horizontal thermal gradients induce a complex flow pattern. In the plane parallel to the tilt axis, the flow pattern is symmetrical and opposite in direction from that where the vessel is positioned vertically. The ground-based experiments are sufficient preliminary tests of theory and should be of significant interest regarding vapor deposited films in microgravity.

Frazier, D. O.↗

Atmospheric Pre-Corrected Differential Absorption Techniques to Retrieve Columnar Water Vapor: Application to AVIRIS 91/95 Data

Water vapor is one of the main forces for weather development as well as for mesoscale air transport processes. The monitoring of water vapor is therefore an important aim in remote sensing of the atmosphere. Current operational systems for water vapor detection use primarily the emission in the thermal infrared (AVHRR, GOES, ATSR, Meteosat) or in the microwave radiation bands (DMSP). The disadvantage of current satellite systems is either a coarse spatial (horizontal) resolution ranging from one to tens of kilometers or a limited insight into the lower atmosphere. Imaging spectrometry on the other hand measures total column water vapor contents at a high spatial horizontal resolution and has therefore the potential of filling these gaps. The sensors of the AVIRIS instrument are capable of acquiring hyperspectral data in 224 bands located in the visible and near infrared at 10 nm resolution. This data includes the information on constituents of the earth's surface as well as of the atmosphere. The optical measurement of water vapor can be performed using sensor channels located in bands or lines of the absorption spectrum. The AVIRIS sensor has been used to retrieve water vapor and with less accuracy carbon dioxide, oxygen and ozone. To retrieve the water vapor amount, the so called differential absorption technique has been applied. The goal of this technique is to eliminate background factors by taking a ratio between channels within the absorption band and others besides the band. Various ratioing methods on the basis of different channels and calculation techniques were developed. The influence of a trace gas of interest on the radiance at the sensor level is usually simulated by using radiative transfer codes. In this study, the spectral transmittance and radiance are calculated by MODTRAN3 simulations with the new DISORT option. The objective of this work is to test the best performing differential absorption techniques for imaging spectrometry of tropospheric water vapor.

Schlaepfer, Daniel↗

LASE validation experiment: preliminary processing of relative humidity from LASE derived water vapor in the middle to upper troposphere

Lidar Atmospheric Sensing Experiment (LASE) is the first fully engineered, autonomous airborne DIAL (Differentials Absorption Lidar) system to measure water vapor, aerosols, and clouds throughout the troposphere. This system uses a double-pulsed Ti:sapphire laser, which is pumped by a frequency-doubled flashlamp-pumped Nd: YAG laser, to transmit light in the 815 mn absorption band of water vapor. LASE operates by locking to a strong water vapor line and electronically tuning to any spectral position on the absorption line to choose the suitable absorption cross-section for optimum measurements over a range of concentrations in the atmosphere. During the LASE Validation Experiment, which was conducted over Wallops Island during September, 1995, LASE operated on either the strong water line for measurements in middle to upper troposphere, or on the weak water line for measurements made in the middle to lower troposphere including the boundary layer. Comparisons with water vapor measurements made by airborne dew point and frost point hygrometers, NASA/GSFC (Goddard Space Flight Center) Raman Lidar, and radiosondes showed the LASE water vapor mixing ratio measurements to have an accuracy of better than 6% or 0.01 g/kg, whichever is larger, throughout the troposphere. In addition to measuring water vapor mixing ratio profiles, LASE simultaneously measures aerosol backscattering profiles at the off-line wavelength near 815 nm from which atmospheric scattering ratio (ASR) profiles are calculated. ASR is defined as the ratio of total (aerosol + molecular) atmospheric scattering to molecular scattering. Assuming a region with very low aerosol loading can be identified, such as that typically found just below the tropopause, then the ASR can be determined. The ASR profiles are calculated by normalizing the scattering in the region containing enhanced aerosols to the expected scattering by the "clean" atmosphere at that altitude. Images of the total ASR clearly depict cloud regions, including multiple cloud layers, thin upper level cirrus, etc., throughout the troposphere. New data products that are being derived from the LASE aerosol and water measurements include: 1) aerosol extinction coefficient, 2) aerosol optical thickness, 3) precipitable water vapor, and 4) relative humidity (RH). These products can be compared with airborne in-situ, and ground and satellite remote sensing measurements,. This paper presents a preliminary examination of RH profiles in the middle to upper troposphere that are generated from LASE measured water vapor mixing ratio profiles coupled with rawinsonde profiles of temperature and pressure.

Brackett, Vincent G.↗

High Temperature Corrosion of Silicon Carbide and Silicon Nitride in Water Vapor

Silicon carbide (SiC) and silicon nitride (Si3N4) are proposed for applications in high temperature combustion environments containing water vapor. Both SiC and Si3N4 react with water vapor to form a silica (SiO2) scale. It is therefore important to understand the durability of SiC, Si3N4 and SiO2 in water vapor. Thermogravimetric analyses, furnace exposures and burner rig results were obtained for these materials in water vapor at temperatures between 1100 and 1450 C and water vapor partial pressures ranging from 0.1 to 3.1 atm. First, the oxidation of SiC and Si3N4 in water vapor is considered. The parabolic kinetic rate law, rate dependence on water vapor partial pressure, and oxidation mechanism are discussed. Second, the volatilization of silica to form Si(OH)4(g) is examined. Mass spectrometric results, the linear kinetic rate law and a volatilization model based on diffusion through a gas boundary layer are discussed. Finally, the combined oxidation and volatilization reactions, which occur when SiC or Si3N4 are exposed in a water vapor-containing environment, are presented. Both experimental evidence and a model for the paralinear kinetic rate law are shown for these simultaneous oxidation and volatilization reactions.

Opila, E. J.↗

The Potential of Water Vapor & Precipitation Estimation with a Differential-frequency Radar

In the presence of rain, the radar return powers from a three-frequency radar, with center frequency at 22.235 GHz and upper and lower frequencies chosen with equal water vapor absorption coefficients, can be used to estimate water vapor density and parameters of the precipitation. A linear combination of differential measurements between the center and lower frequencies on one hand and the upper and lower frequencies on the other provide an estimate of differential water vapor absorption. Conversely, the difference in radar reflectivity factors (in dB) between the upper and lower frequencies is independent of water vapor absorption and can be used to estimate the median mass diameter of the hydrometeors. For a down-looking radar, path-integrated estimates of water vapor absorption may be possible under rain-free as well as raining conditions by using the surface returns at the three frequencies. Cross-talk or interference between the precipitation and water vapor estimates depends on the frequency separation of the channels as well as on the phase state and the median mass diameter of the hydrometeors. Simulations of the retrieval of water vapor absorption show that the largest source of variability arises from the variance in the measured radar return powers while the largest biases occur in the mixed-phase region. Use of high pulse repetition frequencies and signal whitening methods may be needed to obtain the large number of independent samples required. Measurements over a fractional bandwidth, defined as the ratio of the difference between the upper and lower frequencies to the center frequency, up to about 0.2 should be passible in a differential frequency mode, where a single transceiver and antenna are used. Difficulties in frequency allocation may require alternative choices of frequency where the water vapor absorptions at the low and high frequencies are unequal. We consider the degradation in the retrieval accuracy when the frequencies are not optimum.

Meneghini, Robert↗

Vertical Profiles of Mars 1.27 Micrometer O2 Dayglow from MRO CRISM Limb Spectra: Seasonal/global Behaviors, Comparisons to LMDGCM Simulations, and a Global Definition for Mars Water Vapor Profiles

Since July of 2009, The Compact Reconnaissance Imaging Spectral Mapper (CRISM) onboard the Mars Re- connaissance Orbiter (MRO) has periodically obtained pole-to-pole observations (i.e., full MRO orbits) of limb scanned visible/near IR spectra (lambda= 0.4 - 4.0 micrometers, delta lambda approx. 10 nm- Murchie et al., 2007). These CRISM limb observations support the first seasonally and spatially extensive set of Mars 1.27 micometers O2 (1 delta(sub g)) day-glow profile retrievals (approx. 1100) over greater than or equal to 8-80 km altitudes. Their comparison to Laboratoire de Meteorologie Dynamique (LMD) global climate model (GCM) simulated O2 (1 delta(sub g)) volume emission rate (VER) profiles, as a function of altitude, latitude, and season (solar longitude, L(sub s), supports several key conclusions regarding Mars atmospheric water vapor (which is derived from O2 (1 delta(sub g)) emission rates), Mars O3, and the collisional de-excitation of O2 (1 delta(sub g)) in the Mars CO2 atmosphere. Current (Navarro et al., 2014) LMDGCM simulations of Mars atmospheric water vapor fall 2-3 times below CRISM derived water vapor abundances at 20-40 km altitudes over low-to-mid latitudes in northern spring (L(sub s) = 30-60 deg), and northern mid-to-high latitudes over northern summer (L(sub s) = 60-140 deg). In contrast, LMDGCM simulated water vapor is 2-5 times greater than CRISM derived values at all latitudes and seasons above 40 km, within the aphelion cloud belt (ACB), and over high-southern to mid-southern latitudes in southern summer (L(sub s) = 190-340 deg) at 15-35 km altitudes. Overall, the solstitial summer-to-winter hemisphere gradients in water vapor are reversed between the LMDGCM modeled versus the CRISM derived water vapor abundances above 10-30 km altitudes. LMDGCM-CRISM differences in water vapor profiles correlate with LMDGCM-CRISM differences in cloud mixing profiles; and likely reflect limitations in simulating cloud microphysics and radiative forcing, both of which restrict meridional transport of water from summer- to-winter hemispheres on Mars (Clancy et al., 1996; Montmessin et al., 2004; Steele et al., 2014; Navarro et al., 2014) and depend on uncertain cloud microphysical properties (Navarro et al., 2014). The derived low-to-mid latitude changes in Mars water vapor vertical distributions should reduce current model- data disagreements in column O3 and H2O2 abundances over low-to-mid latitudes (e.g., within the ACB; Lefevre et al., 2008; Encrenaz et al., 2015; Clancy et al., 2016). Lastly, the global/seasonal average com- parison of CRISM and LMDGCM O2 (1 delta(sub g)) VER below 20 km altitudes indicates a factor of approx. 3 times lower value (0.25 x 10(exp -20) cu cm sec(exp -1)) for the CO2 collisional de-excitation rate coefficient of O2 (1 delta(sub g)) than derived recently by Guslyakova et al. (2016).

Clancy, R. Todd↗

GEOS Constituent Data Assimilation Beyond Aura MLS: Assimilating NASA SAGE III/ISS Profiles of Stratospheric Water Vapor and Ozone

Ozone and water vapor in the lower stratosphere are important trace gases for atmospheric chemistry and radiative budget. The Stratospheric Aerosol and Gas Experiment (SAGE) missions have been crucial in monitoring the stratospheric ozone loss and the subsequent recovery as well as the trends in water vapor linked to surface temperature trends. The SAGE III instrument aboard the International Space Station (ISS) continues the SAGE mission record, with high vertical resolution profiles of ozone and water vapor available since mid 2017. The NASA GEOS Earth system model has the new capability to assimilate multi-constituents from ground and space-based instruments using the GEOS Constituent Data Assimilation System (CoDAS). The recently released MERRA-2 Stratospheric Composition Reanalysis with Aura MLS (M2-SCREAM) assimilates version 4.2 MLS ozone, water vapor and other chemically-reactive species with the NASA GEOS model coupled to a stratospheric-only chemistry mechanism and transport constrained to the MERRA-2 reanalysis. While the number of solar occultation observations a day from SAGE III/ISS is about 1% of the total number of profiles observed globally by MLS, the chemical timescales of ozone and water vapor in the lower stratosphere are long enough that the SAGE III/ISS data may provide a useful constraint on the assimilated product. Using the same GEOS CoDAS configuration as M2-SCREAM, we will present a series of experiments to investigate if ozone and water vapor trends are consistent with the assimilation of SAGE observations with and without Aura retrievals, and to determine if the assimilation of SAGE observations produces a steady product for trend analysis, especially as the end of the Aura mission nears. In our experiments, assimilating only SAGE III/ISS water vapor profiles results in water vapor fields more consistent with experiments that assimilate MLS v5; however, in the polar regions SAGE III/ISS observations are not available and the values are unconstrained. We are encouraged by the positive benefit assimilating the less frequent SAGE III/ISS observations has on stratospheric composition. Sensitivity experiments such as these will allow us to assess the added value of SAGE data for continued monitoring of the stratospheric composition for climate and ozone recovery assessments.

SAGE↗