Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VANES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Experimental verification of film-cooling concepts on a turbine vane

An investigation was conducted to verify some film cooling concepts applied to gas turbine vanes. The film cooling air was ejected from a single row of holes on the convex surface and a double row of holes of the concave surface. Tests were conducted at a gas temperature of 1260 K, a gas pressure of 3 atmospheres, and a coolant temperature of 280 K. Mass-velocity ratios were varied between 0 and 2.0. Data were taken without film-cooling holes, with film-cooling holes but without blowing, and with blowing. A small amount of blowing into a nonturbulent boundary layer caused an increase in vane temperatures. Film cooling when combined with convection cooling was verified to be more effective than either film or convective cooling alone.

Gladden, H. J.↗

Cyclic structural analysis of air-cooled gas turbine blades and vanes

The creep fatigue behavior of a fully impingement cooled blade for four cyclic cases was analyzed by using the Elas 55, finite element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of strainrange partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange partitioning was also applied to previous results from a one dimensional cyclic analysis of a film impingement cooled vane. The analyses indicated that strainrange partitioning is more applicable to a constrained airfoil such as the film impingement cooled vane than to the relatively unconstrained fully impingement cooled airfoil.

Kaufman, A.↗

Numerical solution for the temperature distribution in a cooled guide vane blade of a radial gas turbine

A two dimensional finite difference numerical technique is presented to determine the temperature distribution of an internal cooled blade of radial turbine guide vanes. A simple convection cooling is assumed inside the guide vane blade. Such cooling has relatively small cooling effectiveness at the leading edge and at the trailing edge. Heat transfer augmentation in these critical areas may be achieved by using impingement jets and film cooling. A computer program is written in FORTRAN IV for IBM 370/165 computer.

Hosny, W. M.↗

Stalled and stall-free performance of axial-flow compressor stage with three inlet-guide-vane and stator-blade settings

The performance of the first stage of a transonic, multistage compressor was mapped over a range of inlet-guide-vane and stator-blade settings. Both stall-free and deep-stall performance data were obtained. For the settings tested, as stall was encountered and flow was further reduced, a relatively sharp drop in pressure ratio occurred and was followed by a continuing but more gradual reduction in pressure ratio with reduced flow. The position of the stall line on the map of pressure ratio against equivalent weight flow was essentially unaffected over the range of inlet-guide-vane and stator-blade settings.

Urasek, D. C.↗

Heat transfer in cooled guide vanes

A numerical study to determine the temperature distribution in the guide vanes of a radial inflow turbine is presented. A computer program has been developed to calculate the temperature distribution when the vanes are cooled internally using a combination of impingement and film cooling techniques. The study is based on the use of the finite difference method in a two dimensional heat conduction problem. The results are then compared to determine the best cooling configuration for a certain coolant to primary mass flow ratio.

Tabakoff, W.↗

Cyclic structural analyses of air-cooled gas turbine blades and vanes

The creep-fatigue behavior of a fully impingement-cooled blade for four cyclic cases was analyzed by using the Elas 55, finite-element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of Strainrange Partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange Partitioning was also applied to previous results from a one-dimensional cyclic analysis of a film-impingement-cooled vane. The analyses indicated that Strainrange Partitioning is more applicable to a constrained airfoil such as the film-impingement-cooled vane than to the relatively unconstrained fully impingement-cooled airfoil.

Kaufman, A.↗

Computation of the temperature distribution in cooled radial inflow turbine guide vanes

A two-dimensional finite-difference numerical technique is presented to determine the temperature distribution of an internally-cooled blade of radial turbine guide vanes. A simple convection cooling is assumed inside the guide vane. Such an arrangement results in relatively small cooling effectiveness at the leading edge and at the trailing edge. Heat transfer augmentation in these critical areas may be achieved by using impingement jets and film cooling. A computer program is written in Fortran IV for IBM 370/165 computer.

Tabakoff, W.↗

Effect of coolant flow ejection on aerodynamic performance of low-aspect-ratio vanes. 2: Performance with coolant flow ejection at temperature ratios up to 2

The aerodynamic performance of a 0.5 aspect ratio turbine vane configuration with coolant flow ejection was experimentally determined in a full annular cascade. The vanes were tested at a nominal mean section ideal critical velocity ratio of 0.890 over a range of primary to coolant total temperature ratio from 1.0 to 2.08 and a range of coolant to primary total pressure ratio from 1.0 to 1.4 which corresponded to coolant flows from 3.0 to 10.7 percent of the primary flow. The variations in primary and thermodynamic efficiency and exit flow conditions with circumferential and radial position were obtained.

Hass, J. E.↗

Manufacture and engine test of advanced oxide dispersion strengthened alloy turbine vanes

Oxide-Dispersion-strengthened (ODS) Ni-Cr-Al alloy systems were exploited for turbine engine vanes which would be used for the space shuttle thermal protection system. Available commercial and developmental advanced ODS alloys were evaluated, and three were selected based on established vane property goals and manufacturing criteria. The selected alloys were evaluated in an engine test. Candidate alloys were screened by strength, thermal fatigue resistance, oxidation and sulfidation resistance. The Ni-16Cr (3 to 5)Al-ThO2 system was identified as having attractive high temperature oxidation resistance. Subsequent work also indicated exceptional sulfidation resistance for these alloys.

Bailey, P. G.↗

FORTRAN program for calculating coolant flow and metal temperatures of a full-coverage-film-cooled vane or blade

A computer program that calculates the coolant flow and the metal temperatures of a full-coverage-film-cooled vane or blade was developed. The analysis was based on compressible, one-dimensional fluid flow and on one-dimensional heat transfer and treats the vane or blade shell as a porous wall. The calculated temperatures are average values for the shell outer-surface area associated with each film-cooling hole row. A thermal-barrier coating may be specified on the shell outer surface, and centrifugal effects can be included for blade calculations. The program is written in FORTRAN 4 and is operational on a UNIVAC 1100/42 computer. The method of analysis, the program input, the program output, and two sample problems are provided.

Meitner, P. L.↗

Analysis of metal temperature and coolant flow with a thermal-barrier coating on a full-coverage-film-cooled turbine vane

The potential benefits of combining full-coverage film cooling with a thermal-barrier coating were investigated analytically for sections on the suction and pressure sides a high-temperature, high-pressure turbine vane. Metal and ceramic coating temperatures were calculated as a function of coating thickness and coolant flow. With a thermal-barrier coating, the coolant flows required for the chosen sections were half those of an uncoated design, and the metal outer temperatures were simultaneously reduced by over 111 K (200 F). For comparison, transpiration cooling was also investigated. Full-coverage film cooling of a coated vane required more coolant flow than did transpiration cooling.

Meitner, P. L.↗

Wind-tunnel fan noise reduction including effects of turning vanes on noise propagation

Fan silencers with low-pressure drop have been designed and installed in the NASA Ames 7- by 10-Foot Wind Tunnel No. 1. The silencers are composed of an absorbent lining flush with the wind-tunnel walls upstream of the fan and an absorbent splitter in the duct downstream of the fan. An acoustical insertion loss of 4 to 12 dB was measured between 100 and 1000 Hz. High-frequency performance of the silencers was reduced by test-section noise and by corner vanes which turned the sound waves so they followed the duct axis. Sound below 1.2 kHz diffracted around the 305-mm-long vanes and impinged on acoustically absorbent corner walls. Wind-tunnel flow losses are discussed.

Soderman, P. T.↗

Prediction method for two-dimensional aerodynamic losses of cooled vanes using integral boundary-layer parameters

A generalized analysis to predict the two-dimensional aerodynamic losses of film-cooled vanes by using integral boundary-layer parameters is presented. Heat-transfer and trailing-edge injection effects are included in the method. An approximate solution of the generalized equations is also included to show more clearly the effect of the different boundary-layer and cooling parameters on the losses. The analytical predictions agree well with the experimental results, indicating that available boundary-layer calculations for cooled vanes are of sufficient accuracy to use in the prediction method.

Goldman, L. J.↗

Plenum response to simulated disturbances of the model and fan inlet guide vanes in a transonic tunnel

In order to aid in the design of the National Transonic Facility (NTF) control system, test section/plenum response studies were carried out in a 0.186 scale model of the NTF high speed duct. Two types of disturbances, those induced by the model and those induced by the compressor inlet guide vanes were simulated. Some observations with regard to the test section/plenum response tests are summarized as follows. A resonance frequency for the test section/plenum area of the tunnel of approximately 50 Hz was observed for Mach numbers from 0.40 to 0.90. However, since the plenum is 3.1 times (based on volume) too large for the scaled size of the test section, care must be taken in extrapolating these data to NTF conditions. The plenum pressure data indicate the existence of pressure gradients in the plenum. The test results indicate that the difference between test section static pressure and plenum pressure is dependent on test section flow conditions. Plenum response to inlet guide vane type disturbances appears to be slower than plenum response to test section disturbances.

Gloss, B. B.↗

Significance of thermal contact resistance in two-layer, thermal-barrier-coated turbine vanes

The paper studies calculated and measured metal wall temperatures of uncoated vanes and the same vanes coated with a thermal barrier coating system of NiCrAlY bond and yttria-stabilized zirconia ceramic. It is shown that thermal contact between layers is negligible. The significance of data scatter and of published ceramic thermal conductivity values is discussed.

Liebert, C. H.↗

Thermal and flow analysis of a convection air-cooled ceramic coated porous metal concept for turbine vanes

The heat transfer and pressure drop through turbine vanes made of a sintered, porous metal coated with a thin layer of ceramic and convection cooled by spanwise flow of cooling air were analyzed. The analysis was made to determine the feasibility of using this concept for cooling very small turbines, primarily for short duration applications such as in missile engines. The analysis was made for gas conditions of approximately 10 and 40 atm and 1644 K and with turbine vanes made of felt type porous metals with relative densities from 0.2 to 0.6 and ceramic coating thicknesses of 0.076 to 0.254 mm.

Stepka, F. S.↗

NASA gas turbine stator vane ring

Four monolithic stator vane rings from reaction-bonded silicon nitride were produced. This paper describes the various steps involved: wax injection of stator vane patterns, precise fixturing of patterns, mold fabrication, slip preparation, casting, prenitriding, nitriding, and ceramic machining. Each process step is discussed and illustrated, and tables of property measurements are included.

Gersch, H. M.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model for a radial turbine with pivoting, variable-area stators is developed through a combination of analytical modeling and experimental data analysis. A viscous loss model is used for the variation in stator loss with setting angle, and stator vane end-clearance leakage effects are predicted by a clearance flow model. The variation of rotor loss coefficient with stator setting angle is obtained by means of an analytical matching of experimental data for a rotor that was tested with six stators, having throat areas from 20 to 144% of the design area. An incidence loss model is selected to obtain best agreement with experimental data. The stator vane end-clearance leakage model predicts increasing mass flow and decreasing efficiency as a result of end-clearances, with changes becoming significantly larger with decreasing stator area.

Meitner, P. L.↗