Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tucker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Developing cathode infiltration processes for all-solid-state bilayer LLZO cells

To realize the bilayer architecture of lithium lanthanum zirconate (LLZO) for application in solid-state batteries (SSBs), the scaffold structure must be optimized, and effective cathode infiltration strategies must be established. In this study, we fabricate a modified bilayer LLZO using a sacrificial layer to enhance surface porosity, and systematically investigate various cathode infiltration techniques to fill the scaffold with oxide cathode active materials (CAM). Structural characterizations showed that the sacrificial layer significantly increased open surface porosity, enabling the surface of the scaffold to be filled with CAM. To further increase infiltration depth, applying vacuum or vibration was compared, with the full-depth infiltration achieved using a sonicator-based vibration. Full cells prepared using the modified bilayer LLZO and vibration-assisted technique demonstrated successful operation. This work demonstrates a practical and scalable approach for engineering bilayer LLZO structures and integrating oxide cathodes into porous scaffolds, offering a promising pathway toward high-performance solid-state batteries.

Bilayer↗

Robust dynamic operation of high temperature electrolysis solid oxide cells

Here, this study evaluates the durability of Ni/YSZ-supported SOECs under dynamic operating conditions relevant to real-world applications. Systematic tests were conducted to assess cell performance under steam cycling (3 to 75% humidified H 2 ), mode cycling between SOFC and SOEC operation, thermal cycling (150 to 750 °C at OCV, and 600 to 800 °C at 1.3V), and redox cycling (between 50% humidified H 2 and 50% humidified N 2 ). Steam cycling, mode cycling, and thermal cycling at OCV do not significantly accelerate performance degradation. Thermal cycling at 1.3V caused minimal damage within 600 to 800 °C. Full redox cycling (multi-hour oxidation holds) induced cell structural failure, while partial redox cycling (0.5 h holds) was tolerated. Extensive characterization revealed some material evolution, namely Sr and Co secondary phase formation, within the oxygen electrode due to La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ instability, especially for steam cycling and mode cycling. Minimal changes were identified within the Ni-YSZ fuel electrodes. These findings provide critical insights into SOEC reliability under dynamic conditions, supporting their application in dynamic or intermittent energy systems.

08 HYDROGEN↗

Origin of enhanced performance when Mn-rich rocksalt cathodes transform to δ -DRX

Most Mn-rich cathodes are known to undergo phase transformation into structures resembling spinel-like ordering upon electrochemical cycling. Recently, the irreversible transformation of Ti-containing Mn-rich disordered rock-salt cathodes into a phase — named δ — with nanoscale spinel-like domains has been shown to increase energy density, capacity retention, and rate capability. However, the nature of the boundaries between domains and their relationship with composition and electrochemistry are not well understood. In this work, we discuss how the transformation into the multi-domain structure results in eight variants of Spinel domains, which is crucial for explaining the nanoscale domain formation in the δ -phase. We study the energetics of crystallographically unique boundaries and the possibility of Li-percolation across them with a fine-tuned CHGNet machine learning interatomic potential. Energetics of 16 d vacancies reveal a strong affinity to segregate to the boundaries, thereby opening Li-pathways at the boundary to enhance long-range Li-percolation in the δ structure. Defect calculations of the relatively low-mobility Ti show how it can influence the extent of Spinel ordering, domain morphology and size significantly; leading to guidelines for engineering electrochemical performance through changes in composition.

Anand, Shashwat↗

The formation and evolution of Ni 2 Cr precipitates in Ni–Cr model alloys as a function of stoichiometry characterized by synchrotron x-ray diffraction

Ni-based alloys containing significant amounts of Cr, may precipitate new phases during long-term service at elevated temperatures. In Ni–Cr model alloys, the formation of Ni 2 Cr has been found to impact the material properties, including the strength and ductility after isothermal aging below the critical temperature of 590°C. In this work, we quantify the formation and evolution of long-range ordering in four Ni–Cr binary model alloys (Ni/Cr = 1.8, 2.0, 2.2, 2.4) after isothermal aging up to 10,000h at temperatures between 373 and 475°C. The alloys were characterized by hardness testing and synchrotron-based x-ray diffraction to quantify the impact of Ni 2 Cr phase fraction and precipitate size on mechanical properties. After 500h of isothermal aging, the formation of Ni 2 Cr was detected in all four alloys at 475°C. In the stochiometric alloy samples (Ni/Cr = 2.0), the formation of Ni 2 Cr was found after 500 and 3000h aging at 418 and 373°C, respectively. We found that the matrix lattice contraction and Ni 2 Cr phase fraction both saturate after early aging times. This is in stark contrast to the hardness and Ni 2 Cr precipitate size that both continue to increase with increasing aging time. Our results highlight that changes in hardness correlate linearly with Ni 2 Cr precipitate size rather than phase fraction. This important structure-property relationship can potentially help define Ni–Cr-based component lifetimes directly through an understanding of how Ni 2 Cr formation impacts strength and ductility. Here, we find that a precipitation hardening model for critical resolved shear stress with weakly coupled dislocations shows good agreement with the material property changes quantified from experimental measurements.

36 MATERIALS SCIENCE↗

Role of Fe in long-range ordered Ni 2 Cr precipitates in Ni-Cr-Fe model alloys during isothermal aging

The precipitation of new phases during long-term service at elevated temperatures is a concern for the thermal stability of engineering alloys. In Ni-Cr-based alloys, e.g., Alloy 690, the formation of long-range ordered Ni 2 Cr causes embrittlement and may impact the lifetime of nuclear power plant components. In this work, we quantify the formation and evolution of Ni 2 Cr precipitation in eleven Ni-Cr-Fe model alloys with 0, 5, 7, and 10wt % Fe contents, and with Ni/Cr atomic ratios of 1.8, 2.0, 2.2, 2.4. These alloys were isothermally aged up to 10,000h at temperatures between 330 and 475°C. The alloys were characterized by synchrotron-based x-ray diffraction and Vickers hardness testing to quantify Ni 2 Cr precipitate size, and the impact of precipitate size on the mechanical properties as a function of Fe content. After 10,000 h of aging at 475°C and 418°C, the formation of Ni 2 Cr was observed in all alloys with 0 and 5wt % Fe. After 10,000h of aging at 418°C, Ni 2 Cr precipitates were also observed in the 7wt % Fe containing Ni/Cr=2.0 sample. Further, no clear evidence of Ni 2 Cr was observed in any of the 10wt % Fe samples at any time and temperature combination. We find that the face-centered cubic matrix lattice contraction and Vickers hardness are correlated with the Ni 2 Cr formation. The greatest change in hardness and lattice contraction occurs in stoichiometric alloys (Ni/Cr=2.0) with 0wt % Fe at 475°C. The rate of change in the material properties for the 5wt % Fe alloys is reduced, however the magnitude of changes is similar to 0wt % Fe alloys. A precipitation hardening model developed for Ni-Cr alloys based on critical resolved shear stress with weakly coupled dislocations shows a clear link between Ni 2 Cr precipitate size and hardness. This trend held across all alloys with Ni 2 Cr formation regardless of Fe concentration. This important structure-property relationship can potentially help define Ni-Cr-Fe-based component lifetimes directly through an understanding of how Ni 2 Cr formation impacts mechanical properties as a function of Fe content.

36 MATERIALS SCIENCE↗

Synthesis, microstructure and micro-mechanical characterization of metal (Nb, Ti) – MAX phase (Ti 2 AlC) nanolaminates

We utilize elevated temperature physical vapor deposition (PVD) techniques to design metal/MAX multilayered nanocomposite thin films with alternating nanoscale metallic (Nb, Ti) and MAX phase (Ti 2 AlC) layer thicknesses. These metal/MAX nanolaminate architectures attempt to exploit a unique hierarchical topology – as interfaces between the layers are expected to be in direct competition with the internal interfaces within the MAX layers, to drive their tunable macroscopic mechanical behavior. Two metal/MAX nanolaminates – Nb/Ti 2 AlC and Ti/Ti 2 AlC – were deposited. The Nb/Ti 2 AlC metal/MAX system showed highly diffused layer interfaces with distinct Ti – rich and Nb–Al – rich layers, with the presence of MAX phase alongside TiC and other Ti–Al and Nb–Al intermetallic phases. The Nb/Ti 2 AlC system possessed a layered architecture, though the MAX phases were not found to be continuously present in each alternating layer. The second Ti/Ti 2 AlC system showed a non-lamellar nanocomposite microstructure and the formation of mixed Ti n+1 AlC n phases (a mix of n = 1, 2), and no indication of layering. Diffusion occurring between the metal/MAX layers in both cases, likely due to the elevated temperatures during the deposition process, is speculated as the likely cause of these resultant microstructures. The mechanical properties of both systems were evaluated using micromechanical (nanoindentation and micro-pillar compression) techniques, which demonstrated high strengths for both systems (Nb system: yield and instability strengths of 4.88 ± 0.1 GPa and 5.57 ± 0.03 GPa, Ti system: yield and instability strength of 5.61 ± 0.28 GPa and 6.21 ± 0.25 GPa). In conclusion, this work highlights the promising mechanical properties of metal/MAX multilayered depositions and summarizes the challenges in PVD synthesis of metal/MAX multilayered nanolaminates.

MAX phase↗

Measurement of G-phase volume fraction and number density in duplex stainless steels using transmission electron microscopy

Duplex stainless steels (DSS) have a high toughness and strength due the presence of both austenitic and ferritic phases. These alloys have had limited use in power production applications due to thermal embrittlement caused by spinodal decomposition and development of G-phase precipitates in the ferrite. Lean grade DSS alloys (e.g., 2101, 2003) may offer improved thermal stability due to the reduction of Cr- and Ni-equivalent elements when compared to standard grade compositions (e.g., 2205, 2209). The abundance of the G-phase was measured in five duplex stainless steels, three wrought alloys (2101, 2003, 2205) and their matching filler metals (2101-w, 2209-w), after aging at 427 °C for 1000 h and 10,000 h. The G-phase volume fraction, number density, size, and precipitate spacing were found using quantitative analysis of transmission electron microscopy dark field images and the composition of G-phase precipitates on other clusters were characterized with atom probe tomography (APT). In the welded alloys, the G-phase was found to develop rapidly, relative to the wrought material. A positive correlation was found between the nickel equivalent composition of the alloy and the G-phase volume fraction. The alloys 2205, 2209, and 2101-w, which are higher in Cr and Ni, all showed significant G-phase precipitation, further strengthening the hypothesis that lean grade DSS alloys are more thermally stable against precipitation in the ferrite. Electron diffraction showed a secondary phase present in the 2101 wrought alloy at 10,000 h, but it was not crystallographically consistent with the G-phase; APT showed the presence of nanoclusters rich in both nickel and copper for this alloy. In conclusion, no secondary phases or clusters were found in 2003 after 10,000 h of aging, so it may be a candidate alloy for applications that require long-life times at high operating temperatures.

36 MATERIALS SCIENCE↗

The CLAS12 Silicon Vertex Tracker

Silicon Vertex Tracker (SVT) has been designed for the CLAS12 spectrometer using single-sided microstrip sensors fabricated by Hamamatsu Photonics. The sensors have a graded angle design to minimize dead areas and a readout pitch of 156 um, with intermediate strips. Each double-sided SVT module hosts three daisy-chained sensors on each side with a full strip length of 33 cm. There are 512 channels per module, read out by four Fermilab Silicon Strip Readout (FSSR2) chips, featuring data-driven architecture, mounted on a rigid–flex hybrid board. The modules are assembled in a barrel configuration using a unique cantilevered geometry to minimize the amount of material in the tracking volume. This paper is focused on the design, qualification of the performance, and experience in operating and commissioning the tracker during the first year of the data taking.

47 OTHER INSTRUMENTATION↗

Evaluating Fracture Behavior of Bioinspired Alumina-YSZ Composites through Static and Dynamic Mechanical Testing

Ceramic materials are known for their high hardness and strength but are limited by low toughness and sudden failure. Inspired by the microstructure of dental enamel, which features undulating rods that promote crack deflection and energy absorption, architected specimens were designed and manufactured. A bespoke ball-on-ring (BoR) testing apparatus measured the static biaxial rupture strength of these bioinspired materials. Additionally, impact testing with spherical steel projectiles assessed their behavior under dynamic conditions. Monolithic alumina specimens were compared to architected alumina reinforced with yttria-stabilized zirconia (YSZ) rods produced via direct ink write 3D printing. BoR tests revealed that monolithic alumina had a Weibull modulus of 10.53 and a characteristic strength of 372.3 MPa, while the composite specimens showed a Weibull modulus of 5.46 and a characteristic strength of 213.3 MPa. Although the composite failed at lower stresses and projectile velocities, it exhibited notable crack deflection and fracture resistance, with cracks being effectively interrupted by the rod inclusions. The composite specimens also resulted in fewer and larger fragments upon impact. Finite element simulations confirmed the effectiveness of the rod structures in enhancing fracture resistance.

Bioinspired materials↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma, electron beam and X-ray irradiation effects on polymers in an advanced bone cement mixer device

The medical device industry has been investigating ways to increase the use of alternatives to cobalt-60 gamma radiation and ethylene-oxide gas sterilization, such as electron beam (E-beam) and X-ray radiation, due to regulatory and market pressures. One impediment to switching to E-beam or X-ray technology for sterilization is the lack of data on the effects of these radiation sources on medical device polymers. To provide such data this work considers irradiation and testing of a common single-use medical bone cement mixing system, the Stryker Advanced Cement Mixer (ACM®), that is composed of seven polymer materials. The ACM® devices considered here were processed to sterilization-relevant doses (15, 25, 50, and 70 kGy) using three radiation technologies: gamma, E-beam, and X-ray. The system and its polymer components were tested for product functionality, as well as mechanical and visual properties to determine how exposure effects may be influenced by radiation technology and dose level. We found that although there were instances of statistically significant differences in effects between the gamma-irradiated products and those irradiated with E-beam and X-ray, those effects were negligible in terms of retained functionality of the product and retained mechanical properties of the polymer components. Overall, results of this study demonstrate that, for of the effects studied, E-beam and X-ray are viable alternatives to cobalt-60 gamma radiation for sterilization of the polymer-based device investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

Anisotropic growth of Ni 2 (Cr,Mo) ordered phase in proton irradiated Ni-Cr-Mo alloys

Ni-Cr-Mo alloys are widely used in the nuclear industry as structural materials due to their high temperature strength and corrosion resistance. Ni-based alloys containing around 33 at.% (Cr+Mo) developed a long-range ordered Ni 2 (Cr,Mo) phase after thermal aging and/or irradiation. The ordering mechanism for thermally-aged Ni 2 (Cr,Mo) phase is well-understood, characterized to be sluggish, homogeneous, and isotropic. The ordering mechanism for irradiation-induced Ni 2 (Cr,Mo) phase is not fully understood, characterized as having rapid formation and demonstrating anisotropic precipitation. Here, this work elucidates the anisotropic precipitation and anisotropic precipitation mechanism of Ni 2 (Cr,Mo) after proton irradiation in Ni-Cr-Mo alloys. Selected area electron diffraction and bright-field scanning transmission electron microscopy imaging are used to image superlattice reflections from the ordered phase and irradiation-induced defects, respectively. A higher degree of anisotropic precipitation is observed with increasing dislocation loop and void size; a phenomenon not observed in thermally aged samples.

36 - MATERIALS SCIENCE↗