Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transmission Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Comparative Study of Distribution System Parameter Estimation Methods

In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

distribution system analysis↗

Transmission-and-Distribution Dynamic Co-simulation Framework for Distributed Energy Resource Frequency Response

The rapid deployment of distributed energy resources (DERs) in distribution networks has made it challenging to balance the transmission system and stabilize frequency. DERs have the ability to provide frequency regulation services; however, existing frequency dynamic simulation tools - which were developed mainly for the transmission system - lack the capability to simulate distribution network dynamics with high penetrations of DERs. Although electromagnetic transient simulation tools can simulate distribution network dynamics, the computation efficiency limits their use for large-scale transmission-and-distribution (T&D) co-simulation. This paper presents an efficient open-source T&D dynamic co-simulation framework for DER frequency response based on the HELICS platform and off-the-shelf T&D simulators. The challenge of synchronizing the simulation time between the transmission network and the DERs in the distribution network is solved through the detailed modeling of DERs in frequency dynamic models while DER power flow models are also preserved in the distribution networks, thereby respecting local voltage constraints when dispatching DER power for frequency response. DER frequency response (primary and secondary) is simulated in case studies to validate the proposed framework. Last, the accuracy of the proposed co-simulation model is benchmarked, and a large T&D system simulation (2k transmission and 1M distribution nodes) is presented to demonstrate the efficiency and effectiveness of the overall framework.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Integrating Hydrogen Production and Electricity Markets: Analytical Insights from California

This report compares the cost of different pathways for producing hydrogen in California. In addition to capturing the current cost of electrolyzers and other equipment, the pathways apply current retail electricity tariff options offered by utilities Southern California Edison (SCE), Pacific Gas & Electric Company (PG&E), and San Diego Gas & Electric Company (SDG&E). The analysis also tests the cost of combining hydrogen production with utility-scale wind or solar generation in California. Scenarios examine current costs as well as projections for 2030. The cost benchmark - a relatively low electrolytic hydrogen production cost - is based on the wholesale price of electricity used by a theoretical hydrogen production plant connected directly to the California Independent System Operator (CAISO) transmission system. California law currently prohibits this approach in CAISO, but it is permissible in other organized wholesale electricity markets. The cost for producing hydrogen under 2019 conditions in this theoretical case was approximately $3/kg. Different scenarios are used to examine current costs, e.g., 2019, as well as projections for 2030.

08 HYDROGEN↗

A Novel Method for Setting Meaningful Thresholds for RMS-Energy Oscillation Detectors

Oscillation detection and mitigation is a crucial aspect of reliable power system operation. Several transmission system operators and reliability coordinators use the RMS-energy method of oscillation detection, but the process of setting thresholds is time and labor intensive. The current industry practice in the United States is to set thresholds based on the RMS-energy's value during ambient conditions, which can often lead to nuisance alarms that require thresholds to be manually retuned. In this paper, we propose a method for setting RMS-energy thresholds that directly accounts for oscillation amplitudes specified by the user. A theoretical analysis of the statistical properties of the RMS-energy incorporates these user-specified amplitudes, resulting in thresholds that reliably detect oscillations of interest while avoiding nuisance alarms. Theoretical results are validated with simulated measurements and the real-world practicality of the method is established with publicly available field-measured data from the Grid Event Signature Library.

Follum, James D.↗

Research requirements to reduce civil helicopter life cycle cost

The problem of the high cost of helicopter development, production, operation, and maintenance is defined and the cost drivers are identified. Helicopter life cycle costs would decrease by about 17 percent if currently available technology were applied. With advanced technology, a reduction of about 30 percent in helicopter life cycle costs is projected. Technological and managerial deficiencies which contribute to high costs are examined, basic research and development projects which can reduce costs include methods for reduced fuel consumption; improved turbine engines; airframe and engine production methods; safety; rotor systems; and advanced transmission systems.

Blewitt, S. J.↗

Study of a co-designed decision feedback equalizer, deinterleaver, and decoder

A technique that promises better quality data from band limited channels at lower received power in digital transmission systems is presented. Data transmission, in such systems often suffers from intersymbol interference (ISI) and noise. Two separate techniques, channel coding and equalization, have caused considerable advances in the state of communication systems and both concern themselves with removing the undesired effects of a communication channel. Equalizers mitigate the ISI whereas coding schemes are used to incorporate error-correction. In the past, most of the research in these two areas has been carried out separately. However, the individual techniques have strengths and weaknesses that are complementary in many applications: an integrated approach realizes gains in excess to that of a simple juxtaposition. Coding schemes have been successfully used in cascade with linear equalizers which in the absence of ISI provide excellent performance. However, when both ISI and the noise level are relatively high, nonlinear receivers like the decision feedback equalizer (DFE) perform better. The DFE has its drawbacks: it suffers from error propagation. The technique presented here takes advantage of interleaving to integrate the two approaches so that the error propagation in DFE can be reduced with the help of error correction provided by the decoder. The results of simulations carried out for both, binary, and non-binary, channels confirm that significant gain can be obtained by codesigning equalizer and decoder. Although, systems with time-invariant channels and simple DFE having linear filters were looked into, the technique is fairly general and can easily be modified for more sophisticated equalizers to obtain even larger gains.

Peile, Robert E.↗

Single-lens computed tomography imaging spectrometer and method of capturing spatial and spectral information

Computed tomography imaging spectrometers ("CTISs") employing a single lens are provided. The CTISs may be either transmissive or reflective, and the single lens is either configured to transmit and receive uncollimated light (in transmissive systems), or is configured to reflect and receive uncollimated light (in reflective systems). An exemplary transmissive CTIS includes a focal plane array detector, a single lens configured to transmit and receive uncollimated light, a two-dimensional grating, and a field stop aperture. An exemplary reflective CTIS includes a focal plane array detector, a single mirror configured to reflect and receive uncollimated light, a two-dimensional grating, and a field stop aperture.

Wilson, Daniel W.↗

Ceramic Integration Technologies for Advanced Energy Systems: Critical Needs, Technical Challenges, and Opportunities

Advanced ceramic integration technologies dramatically impact the energy landscape due to wide scale application of ceramics in all aspects of alternative energy production, storage, distribution, conservation, and efficiency. Examples include fuel cells, thermoelectrics, photovoltaics, gas turbine propulsion systems, distribution and transmission systems based on superconductors, nuclear power generation and waste disposal. Ceramic integration technologies play a key role in fabrication and manufacturing of large and complex shaped parts with multifunctional properties. However, the development of robust and reliable integrated systems with optimum performance requires the understanding of many thermochemical and thermomechanical factors, particularly for high temperature applications. In this presentation, various needs, challenges, and opportunities in design, fabrication, and testing of integrated similar (ceramic ceramic) and dissimilar (ceramic metal) material www.nasa.gov 45 ceramic-ceramic-systems have been discussed. Experimental results for bonding and integration of SiC based Micro-Electro-Mechanical-Systems (MEMS) LDI fuel injector and advanced ceramics and composites for gas turbine applications are presented.

Singh, Mrityunjay↗

Control and Simulation of a Grid-Forming Inverter for Hybrid PV-Battery Plants in Power System Black Start

Power system restoration is an important part of system planning. Power utilities are required to maintain black start capable generators that can energize the transmission system and provide cranking power to non-blackstart capable generators. Traditionally, hydro and diesel units are used as black start capable generators. With the increased penetration of bulk size solar farms, inverter based generation can play an important role in faster and parallel black start thus ensuring system can be brought back into service without the conventional delays that can be expected with limited black start generators. Inverter-based photovoltaic (PV) power plants have advantages that are suitable for black start. This paper proposes the modeling, control, and simulation of a grid-forming inverter-based PV-battery power plant that can be used as a black start unit. The inverter control includes both primary and secondary control loops to imitate the control of a conventional synchronous machine. The proposed approach is verified using a test system modified from the IEEE 9-bus system in the time-domain electromagnetic transient simulation tool PSCAD. The simulation results shows voltage and frequency stability during a multi-step black-start and network energization process.

Nguyen, Quan H.↗

State-of-the-art of data collection, analytics, and future needs of transmission utilities worldwide to account for the continuous growth of sensing data

Nowadays, transmission system operators require higher degree of observability in real-time to gain situational awareness and improve the decision-making process to guarantee a safe and reliable operation. Digitalization of energy systems allows utilities to monitor the system dynamic performance in real-time at fast time scales. The use of such technologies has unlocked new opportunities to introduce new data driven algorithms for improving the stability assessment and control of the system. Motivated by these challenges, a group of experts have worked together to highlight and establish a baseline set of these common concerns, which can be used as motivation to propose innovative analytics and data-driven solutions. In this document, the results of a survey on 10 transmission system operators around the world are presented and it aims to understand the current practices of the participating companies, in terms of data acquisition, handling, storage, modelling and analytics. The overall objective of this document is to capture the actual needs from the interviewed utilities, thereby laying the groundwork for setting valid assumptions for the development of advanced algorithms in this field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Structural Analysis of the US ITER ECH Transmission Line System

The electron cyclotron heating (ECH) and current drive system is one of the main plasma heating systems for ITER. It uses high-power microwave beams with the power deposition location steerable across the plasma cross section. Microwave power is conveyed via transmission lines (TLs) that run from the gyrotrons in the radio frequency building through the assembly hall and tokamak building to the ECH launchers within the tokamak vacuum vessel. The ECH system includes a vast array of interconnected TL waveguides, in-line components, and support structures.Finite element (FE) modeling provides an essential means of simulating the system, applying loads and determining deflections, rotations, forces, moments, and stresses in order to evaluate various structural and microwave transmission performance metrics. A representative FE model of the overall ECH TL system is developed in ANSYS®. This top-level model defines the centerline of the waveguide system. Waveguide segments are represented by line elements (beams and pipes) with equivalent section properties, and support structures are represented by boundary conditions. A systematic approach is used to model each ECH component with lumped masses and structurally equivalent stiffness matrices or ANSYS superelements.The top-level TL FE model is used to evaluate the various loads (thermal, vacuum, seismic, etc.) and operating scenarios. The top-level model directly calculates stresses in the straight aluminum waveguide segments. The model provides the forces and moments acting on the in-line components for detailed submodel assessments. Displacement results from the top-level analysis feed into a separate microwave performance model to help determine operational efficiency. All TL performance and thermal-structural requirements are met, as specified by the applicable codes and standards, and successfully documented in numerous technical reports and demonstrated at the final design review.

Shanmugasundaram, Aravind↗

Analysis of the eastern range multiplexed fiber optic IRIG B120 distribution system

A study was conducted to assess the effects of transmitting a precision clock synchronization signal over a commercial multiplexed fiber optic communication system. This study is an evaluation of the distortion and jitter introduced into the signal by this type of transmission system. An analysis comparing signal quality at the multiplexing and demultiplexing ends of the fiber optic communication system shows that the amplitude and phase distortion added to the clock synchronization signal by the transmission system is minimal.

Duncan, Michael J.↗

Solar power satellite microwave power transmission and reception system

The microwave power transmission and reception system of the Satellite Power System (SPS) has been intensively reviewed and assessed in a three-year concept development and evaluation program. This paper will review some concepts of SPS with particular emphasis on the design of the microwave power transmission and reception system. Technology requirements and proposals for meeting them will be discussed for various parts of the microwave system and to some degree for critical components such as power amplifiers. Specific subjects to be discussed are SPS concepts, antenna design, phase control, rectenna, and technology.

Finnell, W.↗

Three-Phase Unbalanced Transient Dynamics and Powerflow for Modeling Distribution Systems With Synchronous Machines

Unlike transmission systems, distribution feeders in North America operate under unbalanced conditions at all times, and generally have a single strong voltage source. When a distribution feeder is connected to a strong substation source, the system is dynamically very stable, even for large transients. However if a distribution feeder, or part of the feeder, is separated from the substation and begins to operate as an islanded microgrid, transient dynamics become more of an issue. To assess the impact of transient dynamics at the distribution level, it is not appropriate to use traditional transmission solvers, which generally assume transposed lines and balanced loads. Full electromagnetic solvers capture a high level of detail, but it is difficult to model large systems because of the required detail. This paper proposes an electromechanical transient model of synchronous machine for distribution-level modeling and microgrids. This approach includes not only the machine model, but also its interface with an unbalanced network solver, and a powerflow method to solve unbalanced conditions without a strong reference bus. The presented method is validated against a full electromagnetic transient simulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wide Area Security Region Final Report

This report develops innovative and efficient methodologies and practical procedures to determine the wide-area security region of a power system, which take into consideration all types of system constraints including thermal, voltage, voltage stability, transient and potentially oscillatory stability limits in the system. The approach expands the idea of transmission system nomograms to a multidimensional case, involving multiple system limits and parameters such as transmission path constraints, zonal generation or load, etc., considered concurrently. The security region boundary is represented using its piecewise approximation with the help of linear inequalities (so called hyperplanes) in a multi-dimensional space, consisting of system parameters that are critical for security analyses. The goal of this approximation is to find a minimum set of hyperplanes that describe the boundary with a given accuracy. Methodologies are also developed to use the security hyperplanes, pre-calculated offline, to determine system security margins in real-time system operations, to identify weak elements in the system, and to calculate key contributing factors and sensitivities to determine the best system controls in real time and to assist in developing remedial actions and transmission system enhancements offline . A prototype program that automates the simulation procedures used to build the set of security hyperplanes has also been developed. The program makes it convenient to update the set of security hyperplanes necessitated by changes in system configurations. A prototype operational tool that uses the security hyperplanes to assess security margins and to calculate optimal control directions in real time has been built to demonstrate the project success. Numerical simulations have been conducted using the full-size Western Electricity Coordinating Council (WECC) system model, and they clearly demonstrated the feasibility and the effectiveness of the developed technology. Recommendations for the future work have also been formulated.

24 POWER TRANSMISSION AND DISTRIBUTION↗