Dynamic gas temperature measurement system. Volume 2: Operation and program manual

The hot section technology (HOST) dynamic gas temperature measurement system computer program acquires data from two type B thermocouples of different diameters. The analysis method determines the in situ value of an aerodynamic parameter T, containing the heat transfer coefficient from the transfer function of the two thermocouples. This aerodynamic parameter is used to compute a fequency response spectrum and compensate the dynamic portion of the signal of the smaller thermocouple. The calculations for the aerodynamic parameter and the data compensation technique are discussed. Compensated data are presented in either the time or frequency domain, time domain data as dynamic temperature vs time, or frequency domain data.

Purpura, P. T.↗

Evaluation of Raytek infrared pyrometer for continuous propellant temperature measurement

The primary purpose of this evaluation was to determine if the Raytek IR pyrometer that was installed in the 600 gallon propellant mixers could be used to provide a continuous, accurate, reliable measurement of the propellant temperature during mixing. The Raytek infrared sensor is not recommended to be used for controlling propellant temperature nor for inspection buy-off. The first part of the evaluation was to determine the accuracy of the sensor in measuring the propellant temperature. The second part was to determine the reliability of the air purge design in preventing contamination of the IR window.

Dykstra, Mark D.↗

Method of and apparatus for measuring temperature and pressure

Laser beams are transmitted through gas to a reflecting target, which may be either a solid surface or particulate matter in gas or the gas molecules. The return beams are measured to determine the amount of energy absorbed by the gas. For temperature measurements, the laser beam has a wavelength at which the gas exhibits a relatively temperature sensitive and pressure insensitive absorption characteristic for pressure measurements, the laser beam has a wavelength at which the gas has a relatively pressure sensitive and temperature insensitive absorption characteristic. To reduce the effects of scattering on the absorption measurements a reference laser beam with a weak absorption characteristic is transmitted colinearly with the data beam having a strong absorption characteristic. The two signals are processed as a ratio to eliminate back scattering. Embodiments of transmitters and receivers described include a sequential laser pulse transmitter and receiver, a simultaneous laser pulse transmitter and receiver.

Korb, C. L.↗

Diagnostics of Carbon Nanotube Formation in a Laser Produced Plume: Spectroscopic in situ nanotube detection using spectral absorption and surface temperature measurements by black body emission

Carbon nanotubes hold great promise for material advancements in the areas of composites and electronics. The advancement of research in these areas is dependent upon the availability of carbon nanotubes to a broad spectrum of academic and industrial researchers. Although there has been much progress made in reducing the costs of carbon nanotubes and increasing the quality and purity of the products, an increase in demand for still less expensive and specific nanotubes types has also grown. This summer's work has involved two experiments that have been designed to further the understanding of the dynamics and chemical mechanisms of carbon nanotube formation. It is expected that a better understanding of the process of formation of nanotubes will aid current production designs and stimulate ideas for future production designs increasing the quantity, quality, and production control of carbon nanotubes. The first experiment involved the measurement of surface temperature of the target as a function of time with respect to the ablation lasers. A peak surface temperature of 5000 K was determined from spectral analysis of black body emission from the target surface. The surface temperature as a function of various changes in operating parameters was also obtained. This data is expected to aid the modeling of ablation and plume dynamics. The second experiment involved a time and spatial measurement of the spectrally resolved absorbance of the laser produced plume. This experiment explored the possibility of developing absorbance and fluorescence to detect carbon nanotubes during production. To attain control over the production of nanotubes with specific properties and reduce costs, a real time in situ diagnostics method would be very beneficial. Results from this summer's work indicate that detection of nanotubes during production may possibly be used for production feed back control.

DeBoer, Gary D.↗

Attachment of Free Filament Thermocouples for Temperature Measurements on CMC

Ceramic Matrix Composites (CMC) are being developed for use as enabling materials for advanced aeropropulsion engine and high speed civil transport applications. The characterization and testing of these advanced materials in hostile, high-temperature environments require accurate measurement of the material temperatures. Commonly used wire Thermo-Couples (TC) can not be attached to this ceramic based material via conventional spot-welding techniques. Attachment of wire TC's with commercially available ceramic cements fail to provide sufficient adhesion at high temperatures. While advanced thin film TC technology provides minimally intrusive surface temperature measurement and has good adhesion on the CMC, its fabrication requires sophisticated and expensive facilities and is very time consuming. In addition, the durability of lead wire attachments to both thin film TC's and the substrate materials requires further improvement. This paper presents a newly developed attachment technique for installation of free filament wire TC's with a unique convoluted design on ceramic based materials such as CMC's. Three CMC's (SiC/SiC CMC and alumina/alumina CMC) instrumented with type IC, R or S wire TC's were tested in a Mach 0.3 burner rig. The CMC temperatures measured from these wire TC's were compared to that from the facility pyrometer and thin film TC's. There was no sign of TC delamination even after several hours exposure to 1200 C. The test results proved that this new technique can successfully attach wire TC's on CMC's and provide temperature data in hostile environments. The sensor fabrication process is less expensive and requires very little time compared to that of the thin film TC's. The same installation technique/process can also be applied to attach lead wires for thin film sensor systems.

Lei, Jih-Fen↗

Further development of the dynamic gas temperature measurement system. Volume 1: Technical efforts

A compensated dynamic gas temperature thermocouple measurement method was experimentally verified. Dynamic gas temperature signals from a flow passing through a chopped-wheel signal generator and an atmospheric pressure laboratory burner were measured by the dynamic temperature sensor and other fast-response sensors. Compensated data from dynamic temperature sensor thermoelements were compared with fast-response sensors. Results from the two experiments are presented as time-dependent waveforms and spectral plots. Comparisons between compensated dynamic temperature sensor spectra and a commercially available optical fiber thermometer compensated spectra were made for the atmospheric burner experiment. Increases in precision of the measurement method require optimization of several factors, and directions for further work are identified.

Elmore, D. L.↗

Noncontact temperature measurement in glass and other transparent materials

The relationship between the optical properties of glass and temperature measurements in it by radiation pyrometry are described. Equations for the calculation of emissivity are presented and the transmittance, surface reflection and absorption characteristics of glass are defined. Recommendations are given regarding the selection of pyrometer wavelength sensitivity and the use of a blackbody radiator.

Doremus, Robert H.↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Design improvements for a recirculating reactor: Enhanced temperature measurement and sample-isolated reactivity in steady-state kinetic studies

Building upon a previous recirculating reactor design [S.A. Tenney, K. Xie, J.R. Monnier, A. Rodriguez, R.P. Galhenage, S. Audrey, D.A. Chen, Rev. Sci. Instrum. 84, 104101 (2013)], we present significant improvements that address key limitations in steady-state kinetic measurements for heterogeneous catalysis. The enhanced reactor design features direct sample heating with a focused IR lamp and temperature measurement in direct contact with the sample, enabling more accurate temperature control and improved kinetic analysis. A critical advancement is the isolation of sample reactivity from reactor wall contributions, ensuring that only the sample contributes to measured reaction rates. This was a limitation in earlier designs where the entire reactor contributed to the observed reactivity. The system incorporates a bypass flow cell for direct comparison with powder catalysts under identical conditions using a standard plug-flow reactor configuration. We demonstrate these capabilities through CO oxidation experiments on Pt(111) single crystals and graphene-passivated Pt(111), highlighting the system's ability to differentiate catalytic activity in model systems and directly compare them with high surface area powder catalysts. This reactor is particularly suited for thin films and low surface area catalysts that are not effectively evaluated in traditional flow reactors, especially for samples with low numbers of active sites or slow reaction rates.

36 MATERIALS SCIENCE↗

Complexities of nadir-looking radiometric temperature measurements of plant canopies

Effective radiant temperatures (ERTs) of five wheat canopies in different stages of development were measured during morning and noon periods. The observed variability in nadir sensor response was quantitatively described as a function of canopy structure and the vertical temperature profile of canopy components. In many cases, the nadir sensor ERT was a poor measure of vegetation temperature due to effects of soil emissions. Strong vertical temperature profiles of vegetation components were also observed. The theory and measurements presented document that remote measurements of vegetation canopy temperatures cannot be made indiscriminately over large spatial regions without consideration of the underlying physical principles.

Kimes, D. S.↗

2D velocity and temperature measurements in high speed flows based on spectrally resolved Rayleigh scattering

The use of molecular Rayleigh scattering for measurements of gas velocity and temperature is evaluated. Molecular scattering avoids problems associated with the seeding required by conventional laser anemometry and particle image velocimetry. The technique considered herein is based on the measurement of the spectrum of the scattered light. Planar imaging of Rayleigh scattering using a laser light sheet is evaluated for conditions at 30 km altitude (typical hypersonic flow conditions). The Cramer-Rao lower bounds for velocity and temperature measurement uncertainties are calculated for an ideal optical spectrum analyzer and for a planar mirror Fabry-Perot interferometer used in a static, imaging mode. With this technique, a single image of the Rayleigh scattered light from clean flows can be analyzed to obtain temperature and one component of velocity. Experimental results are presented for planar velocity measurements in a Mach 1.3 air jet.

Seasholtz, Richard G.↗

Floating Probe Assembly for Measuring Temperature of Water

A floating apparatus denoted a temperature probe aquatic suspension system (TPASS) has been developed for measuring the temperature of an ocean, lake, or other natural body of water at predetermined depths. Prior instruments built for the same purpose were found to give inaccurate readings because the apparatuses themselves significantly affected the temperatures of the water in their vicinities. The design of the TPASS is intended to satisfy a requirement to minimize the perturbation of the temperatures to be measured. The TPASS includes a square-cross-section aluminum rod 28 in. (=71 cm) long with floats attached at both ends. Each float includes five polystyrene foam disks about 3/4 in.(=1.9 cm) thick and 2.5 in. (=6.4 cm) in diameter. The disks are stacked to form cylinders, bolted to the rod, and covered with hollow plastic sleeves. A metal sleeve is clamped to the middle of the aluminum rod, from whence it hangs down into the water. Temperature probes (which can be thermocouples, thermistors, or resistance temperature devices) are placed within the sleeve at the desired measurement depths. Wires from the temperature probes are routed to the input terminals of a data logger.

Stewart, Randy↗