Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Bragg curve spectroscopy for improved fission fragment identification

We report on the development of Bragg curve spectroscopy techniques to improve fission fragment identification in the measurement of independent fission product yields. The NIFFTE collaboration’s fissionTPC detector provides ionization energy and particle tracking information from neutroninduced fission targets. A joint effort between PNNL, LLNL, LANL, and the Colorado School of Mines is investigating the ionization profiles deposited by U-235, U-238, and Pu-239 fission products in this detector, with the goal of including additional stopping power information beyond a standard 2E analysis. The aim is to improve the determination of fragment atomic and mass numbers with this information, via methods such as parametric fits and machine learning techniques.

Fulsom, Bryan G.↗

Calibration of the DUNE Far Detector Using Cosmic-ray Muon Events

The Deep Underground Neutrino Experiment (DUNE) aims to set new limits on parameters associated with neutrino oscillations, neutrino astrophysics, and beyond the Standard Model (SM) searches such as nucleon decay. DUNE will quantify the magnitude of CP violation in the lepton sector, and determine the neutrino mass ordering. These benefit highly from the large target mass and excellent imaging, tracking, and particle identification capabilities of Liquid Argon Time Projection Chambers (LArTPCs). Detector calibration is essential to make precise physics measurements. For instance, accurate energy reconstruction is necessary for measuring many of the aforementioned quantities with the precision required for discovering new physics and fully exploiting the capabilities of the detector. Cosmic muons are a freely available natural source of calorimetric data and can be used for calibrating various detector parameters. This thesis provides an analysis of simulated cosmic-ray muon events generated with the Muon Simulation Underground (MUSUN) generator in the DUNE horizontal drift (HD) far detector (FD). The study focuses on analysing the energy and angular distribution of various classes of muon events, as well as characterising the different particles produced by cosmic muon interactions. The analysis of π0 → 2γ events within the cosmic-ray muon sample is presented in this thesis with a detailed study of reconstructing electromagnetic showers. The π0 mass is reconstructed within the DUNE FD, yielding a value of (136 ± 7) MeV/c2. Additionally, the thesis introduces methods for dE/dx calibration using simulated and reconstructed muon tracks. A calibration constant Ccal = (5.469 ± 0.003) × 10−3 ADC × tick/e is obtained through a model-dependent calibration process, where 1 tick corresponds to 500 ns of sampling time of an ADC. Furthermore, a calibration technique is presented, demonstrating precise translation from dQ/dx to dE/dx. This calibration method is applied to stopping muons, charged pions, and protons in the DUNE FD, addressing the measurement of energy loss in the detector volume. These are important calibrations of the DUNE FD and will contribute to achieving the exciting physics goals of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic tumor tracking using the Elekta Agility MLC

Purpose: To evaluate the performance of the Elekta Agility multileaf collimator (MLC) for dynamic real-time tumor tracking. Methods: The authors have developed a new control software which interfaces to the Agility MLC to dynamically program the movement of individual leaves, the dynamic leaf guides (DLGs), and the Y collimators (“jaws”) based on the actual target trajectory. A motion platform was used to perform dynamic tracking experiments with sinusoidal trajectories. The actual target positions reported by the motion platform at 20, 30, or 40 Hz were used as shift vectors for the MLC in beams-eye-view. The system latency of the MLC (i.e., the average latency comprising target device reporting latencies and MLC adjustment latency) and the geometric tracking accuracy were extracted from a sequence of MV portal images acquired during irradiation for the following treatment scenarios: leaf-only motion, jaw + leaf motion, and DLG + leaf motion. Results: The portal imager measurements indicated a clear dependence of the system latency on the target position reporting frequency. Deducting the effect of the target frequency, the leaf adjustment latency was measured to be 38 ± 3 ms for a maximum target speed v of 13 mm/s. The jaw + leaf adjustment latency was 53 ± 3 at a similar speed. The system latency at a target position frequency of 30 Hz was in the range of 56–61 ms for the leaves (v ≤ 31 mm/s), 71–78 ms for the jaw + leaf motion (v ≤ 25 mm/s), and 58–72 ms for the DLG + leaf motion (v ≤ 59 mm/s). The tracking accuracy showed a similar dependency on the target position frequency and the maximum target speed. For the leaves, the root-mean-squared error (RMSE) was between 0.6–1.5 mm depending on the maximum target speed. For the jaw + leaf (DLG + leaf) motion, the RMSE was between 0.7–1.5 mm (1.9–3.4 mm). Conclusions: The authors have measured the latency and geometric accuracy of the Agility MLC, facilitating its future use for clinical tracking applications.

60 APPLIED LIFE SCIENCES↗

Charge changing cross-sections for 300 A MeV Fe{sup 26+} ion beam in Al target

In the present study, total and partial charge changing cross-sections of 300 A MeV Fe{sup 26+} ion beam in Al target were measured. The CR39 nuclear track detectors were used to identify the incident charged particles and their fragments using an automated image analyzer system installed with Leica QWin Plus software. The measured value of the total charge changing cross-section is {sigma}{sub tot}= (1663 {+-} 236) mb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studying the effect of drug-to-excipient ratio on drug release profile for drug coated balloons

Drug-coated balloons (DCB) have emerged as the alternative procedure for restenosis because of their ability to treat a variety of occlusion types with a uniform dose of anti-proliferative drugs. DCB are balloons coated with antiproliferative drugs encapsulated in a polymer matrix. There are several types of coating matrices used to produce DCB. In this study, the relationship between coating composition and drug release under physiologically relevant conditions was examined to understand how differences in coating composition impacts the drug transfer from the balloon surface to the simulated body fluids. To conduct the experiments, the balloons were coated with different paclitaxel (drug)-to-iopromide (excipient) ratios (3:1, 3:2 and 1:2) using an in-house developed micro-pipetting method. Scanning electron microscopy (SEM) images showed that the 3:1 PTX:IOP ratio produced a more uniform, crystalline microstructure with a thinner coating throughout the balloon surface compared to the other drug-to-excipient ratios. The 1:2 PTX:IOP ratio showed the least crystalline microstructure among the three ratios evaluated in this study. Three different drug elution conditions were tested. The amount of drug released to the medium was quantified by high performance liquid chromatography (HPLC). Our soaking study and submerge & deploy study showed that ~20% of the drug transferred to the target site under physiological conditions. A track and deploy method was performed using a “mock” artery, to simulate an in vitro environment. Coated balloons were passed through the mock artery to mimic tracking turns the balloon within the arteries during the angioplasty procedures. Seven elution samples were collected at different stages of the procedure. Finally, drug release results suggest that the higher excipient ratio helps to deliver the lipophilic drug to the target site under simulated conditions but causes higher drug loss during the balloon transfer process.

60 APPLIED LIFE SCIENCES↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Evaluation of potential internal target volume of liver tumors using cine-MRI

Purpose: Four-dimensional computed tomography (4DCT) is widely used for evaluating moving tumors, including lung and liver cancers. For patients with unstable respiration, however, the 4DCT may not visualize tumor motion properly. High-speed magnetic resonance imaging (MRI) sequences (cine-MRI) permit direct visualization of respiratory motion of liver tumors without considering radiation dose exposure to patients. Here, the authors demonstrated a technique for evaluating internal target volume (ITV) with consideration of respiratory variation using cine-MRI. Methods: The authors retrospectively evaluated six patients who received stereotactic body radiotherapy (SBRT) to hepatocellular carcinoma. Before acquiring planning CT, sagittal and coronal cine-MRI images were acquired for 30 s with a frame rate of 2 frames/s. The patient immobilization was conducted under the same condition as SBRT. Planning CT images were then acquired within 15 min from cine-MRI image acquisitions, followed by a 4DCT scan. To calculate tumor motion, the motion vectors between two continuous frames of cine-MRI images were calculated for each frame using the pyramidal Lucas–Kanade method. The target contour was delineated on one frame, and each vertex of the contour was shifted and copied onto the following frame using neighboring motion vectors. 3D trajectory data were generated with the centroid of the contours on sagittal and coronal images. To evaluate the accuracy of the tracking method, the motion of clearly visible blood vessel was analyzed with the motion tracking and manual detection techniques. The target volume delineated on the 50% (end-exhale) phase of 4DCT was translated with the trajectory data, and the distribution of the occupancy probability of target volume was calculated as potential ITV (ITV {sub Potential}). The concordance between ITV {sub Potential} and ITV estimated with 4DCT (ITV {sub 4DCT}) was evaluated using the Dice’s similarity coefficient (DSC). Results: The distance between blood vessel positions determined with motion tracking and manual detection was analyzed. The mean and SD of the distance were less than 0.80 and 0.52 mm, respectively. The maximum ranges of tumor motion on cine-MRI were 2.4 ± 1.4 mm (range, 1.0–5.0 mm), 4.4 ± 3.3 mm (range, 0.8–9.4 mm), and 14.7 ± 5.9 mm (range, 7.4–23.4 mm) in lateral, anterior–posterior, and superior–inferior directions, respectively. The ranges in the superior–inferior direction were larger than those estimated with 4DCT images for all patients. The volume of ITV {sub Potential} was 160.3% ± 13.5% (range, 142.0%–179.2%) of the ITV {sub 4DCT}. The maximum DSC values were observed when the cutoff value of 24.7% ± 4.0% (range, 20%–29%) was applied. Conclusions: The authors demonstrated a novel method of calculating 3D motion and ITV {sub Potential} of liver cancer using orthogonal cine-MRI. Their method achieved accurate calculation of the respiratory motion of moving structures. Individual evaluation of the ITV {sub Potential} will aid in improving respiration management and treatment planning.

60 APPLIED LIFE SCIENCES↗

A bronchoscopic navigation system using bronchoscope center calibration for accurate registration of electromagnetic tracker and CT volume without markers

Purpose: Various bronchoscopic navigation systems are developed for diagnosis, staging, and treatment of lung and bronchus cancers. To construct electromagnetically navigated bronchoscopy systems, registration of preoperative images and an electromagnetic tracker must be performed. This paper proposes a new marker-free registration method, which uses the centerlines of the bronchial tree and the center of a bronchoscope tip where an electromagnetic sensor is attached, to align preoperative images and electromagnetic tracker systems. Methods: The chest computed tomography (CT) volume (preoperative images) was segmented to extract the bronchial centerlines. An electromagnetic sensor was fixed at the bronchoscope tip surface. A model was designed and printed using a 3D printer to calibrate the relationship between the fixed sensor and the bronchoscope tip center. For each sensor measurement that includes sensor position and orientation information, its corresponding bronchoscope tip center position was calculated. By minimizing the distance between each bronchoscope tip center position and the bronchial centerlines, the spatial alignment of the electromagnetic tracker system and the CT volume was determined. After obtaining the spatial alignment, an electromagnetic navigation bronchoscopy system was established to real-timely track or locate a bronchoscope inside the bronchial tree during bronchoscopic examinations. Results: The electromagnetic navigation bronchoscopy system was validated on a dynamic bronchial phantom that can simulate respiratory motion with a breath rate range of 0–10 min{sup −1}. The fiducial and target registration errors of this navigation system were evaluated. The average fiducial registration error was reduced from 8.7 to 6.6 mm. The average target registration error, which indicates all tracked or navigated bronchoscope position accuracy, was much reduced from 6.8 to 4.5 mm compared to previous registration methods. Conclusions: An electromagnetically navigated bronchoscopy system was constructed with accurate registration of an electromagnetic tracker and the CT volume on the basis of an improved marker-free registration approach that uses the bronchial centerlines and bronchoscope tip center information. The fiducial and target registration errors of our electromagnetic navigation system were about 6.6 and 4.5 mm in dynamic bronchial phantom validation.

60 APPLIED LIFE SCIENCES↗

Tracking of buried layers during plasma-assisted femtosecond laser drilling of compound targets

It was shown that drilling of multi-layered target placed in the air by tightly focused femtosecond laser radiation with high fluence (up to 1000 J/cm{sup 2}) can be monitored online using plasma-induced X-ray emission and second harmonic of incident laser radiation. The technique based on X-rays registration is appeared to be more flexible than the method based on detection of second harmonic since its accuracy depends crucially on the target type. We demonstrated that the X-ray signal clearly indicates the transition from one layer to another during the microdrilling of targets consisting of 2–4 layers of titanium foil when a laser beam is focused beneath the target surface at a depth comparable to the layer thickness. The diagnostics of microchannel production in the chicken eggshell was performed for the first time. It was found that the presence of albumen beneath the shell accounts for longtime generation of X-ray pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-dimensional liver motion tracking using real-time two-dimensional MRI

Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Physics Coupling to Model a RbCl-RbCl-Ga Target Stack

A computational model has been developed to simulate the performance of the Los Alamos Isotope Production Facility's (IPF) routine production target configuration, which consists of two Inconel-encapsulated RbCl salt targets and one niobium-encapsulated gallium target separated by water cooling channels. The methodology involves iteratively coupling particle transport and thermal hydraulic codes to determine the time dependent behavior of the target. Phase and density changes seen in targets are known to impact beam penetration and distribution. In addition, evidence of energy distributions seen in experimental radionuclide yield measurements at IPF do not match those seen in previous MCNP predictions. Density reduction as a result of heat deposition affects proton energy loss along the particle's track, impacting both radionuclide yields and target design. Accurate modeling of the thermal behavior of these multi-phase targets and the corresponding impact on beam behavior will significantly improve our understanding of incident and exit proton energy distributions and resulting radionuclide yields in downstream targets. Thermal hydraulic modeling, including computational fluid dynamics (CFD) and heat transfer, was performed with ANSYS CFX while particle transport was performed with the Monte Carlo N-Particle code (MCNP). (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Elliptical ejecta of asteroid Dimorphos is due to its surface curvature

Kinetic deflection is a planetary defense technique delivering spacecraft momentum to a small body to deviate its course from Earth. The deflection efficiency depends on the impactor and target. Among them, the contribution of global curvature was poorly understood. The ejecta plume created by NASA’s Double Asteroid Redirection Test impact on its target asteroid, Dimorphos, exhibited an elliptical shape almost aligned along its north-south direction. Here, we identify that this elliptical ejecta plume resulted from the target’s curvature, reducing the momentum transfer to 44 ± 10% along the orbit track compared to an equivalent impact on a flat target. We also find lower kinetic deflection of impacts on smaller near-Earth objects due to higher curvature. A solution to mitigate low deflection efficiency is to apply multiple low-energy impactors rather than a single high-energy impactor. Rapid reconnaissance to acquire a target’s properties before deflection enables determining the proper locations and timing of impacts.

79 ASTRONOMY AND ASTROPHYSICS↗

Potential benefits of dosimetric VMAT tracking verified with 3D film measurements

Purpose: To evaluate three different plan adaptation strategies using 3D film-stack dose measurements of both focal boost and hypofractionated prostate VMAT treatments. The adaptation strategies (a couch shift, geometric tracking, and dosimetric tracking) were applied for three realistic intrafraction prostate motions. Methods: A focal boost (35 × 2.2 and 35 × 2.7 Gy) and a hypofractionated (5 × 7.25 Gy) prostate VMAT plan were created for a heterogeneous phantom that allows for internal prostate motion. For these plans geometric tracking and dosimetric tracking were evaluated by ionization chamber (IC) point dose measurements (zero-D) and measurements using a stack of EBT3 films (3D). The geometric tracking applied translations, rotations, and scaling of the MLC aperture in response to realistic prostate motions. The dosimetric tracking additionally corrected the monitor units to resolve variations due to difference in depth, tissue heterogeneity, and MLC-aperture. The tracking was based on the positions of four fiducial points only. The film measurements were compared to the gold standard (i.e., IC measurements) and the planned dose distribution. Additionally, the 3D measurements were converted to dose volume histograms, tumor control probability, and normal tissue complication probability parameters (DVH/TCP/NTCP) as a direct estimate of clinical relevance of the proposed tracking. Results: Compared to the planned dose distribution, measurements without prostate motion and tracking showed already a reduced homogeneity of the dose distribution. Adding prostate motion further blurs the DVHs for all treatment approaches. The clinical practice (no tracking) delivered the dose distribution inside the PTV but off target (CTV), resulting in boost dose errors up to 10%. The geometric and dosimetric tracking corrected the dose distribution’s position. Moreover, the dosimetric tracking could achieve the planned boost DVH, but not the DVH of the more homogeneously irradiated prostate. A drawback of both the geometric and dosimetric tracking was a reduced MLC blocking caused by the rotational component of the MLC aperture corrections. Because of the used CTV to PTV margins and the high doses in the considered fractionation schemes, the TCP differed less than 0.02 from the planned value for all targets and all correction methods. The rectal NTCP constraints, however, could not be realized using any of these methods. Conclusions: The geometric and dosimetric tracking use only a limited input, but they deposit the dose distribution with higher geometric accuracy than the clinical practice. The latter case has boost dose errors up to 10%. The increased accuracy has a modest impact [Δ(NT)CP < 0.02] because of the applied margins and the high dose levels used. To allow further margin reduction tracking methods are vital. The proposed methodology could further be improved by implementing a rotational correction using collimator rotations.

60 APPLIED LIFE SCIENCES↗

Motion correction for passive radiation imaging of small vessels in ship-to-ship inspections

Passive radiation detection remains one of the most acceptable means of ascertaining the presence of illicit nuclear materials. In maritime applications it is most effective against small to moderately sized vessels, where attenuation in the target vessel is of less concern. Unfortunately, imaging methods that can remove source confusion, localize a source, and avoid other systematic detection issues cannot be easily applied in ship-to-ship inspections because relative motion of the vessels blurs the results over many pixels, significantly reducing system sensitivity. This is particularly true for the smaller watercraft, where passive inspections are most valuable. We have developed a combined gamma-ray, stereo visible-light imaging system that addresses this problem. Data from the stereo imager are used to track the relative location and orientation of the target vessel in the field of view of a coded-aperture gamma-ray imager. Using this information, short-exposure gamma-ray images are projected onto the target vessel using simple tomographic back-projection techniques, revealing the location of any sources within the target. Here,the complex autonomous tracking and image reconstruction system runs in real time on a 48-core workstation that deploys with the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the polar neutron-imaging aperture for use at the National Ignition Facility

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 μm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 μm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing trigger-level track reconstruction for sensitivity to exotic signatures

Many compelling beyond the Standard Model scenarios predict signals that result in unconventional charged particle trajectories. Signatures for which unusual tracks are the most conspicuous feature of the event pose significant challenges for experiments at the Large Hadron Collider (LHC), particularly for the trigger. This article presents a study of track-based triggers for a representative set of long-lived and unconventional signatures at the upcoming High Luminosity LHC, as well as resulting recommendations for the target parameters of a hardware-based tracking system. Scenarios studied include large multiplicities of low-p T tracks produced in a soft-unclustered-energy-pattern model, displaced leptons and anomalous prompt tracks predicted in a Supersymmetry model with long-lived staus, and displaced hadrons predicted in a Higgs portal scenario with long-lived scalars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Toward the development of intrafraction tumor deformation tracking using a dynamic multi-leaf collimator

Purpose: Intrafraction deformation limits targeting accuracy in radiotherapy. Studies show tumor deformation of over 10 mm for both single tumor deformation and system deformation (due to differential motion between primary tumors and involved lymph nodes). Such deformation cannot be adapted to with current radiotherapy methods. The objective of this study was to develop and experimentally investigate the ability of a dynamic multi-leaf collimator (DMLC) tracking system to account for tumor deformation. Methods: To compensate for tumor deformation, the DMLC tracking strategy is to warp the planned beam aperture directly to conform to the new tumor shape based on real time tumor deformation input. Two deformable phantoms that correspond to a single tumor and a tumor system were developed. The planar deformations derived from the phantom images in beam's eye view were used to guide the aperture warping. An in-house deformable image registration software was developed to automatically trigger the registration once new target image was acquired and send the computed deformation to the DMLC tracking software. Because the registration speed is not fast enough to implement the experiment in real-time manner, the phantom deformation only proceeded to the next position until registration of the current deformation position was completed. The deformation tracking accuracy was evaluated by a geometric target coverage metric defined as the sum of the area incorrectly outside and inside the ideal aperture. The individual contributions from the deformable registration algorithm and the finite leaf width to the tracking uncertainty were analyzed. Clinical proof-of-principle experiment of deformation tracking using previously acquired MR images of a lung cancer patient was implemented to represent the MRI-Linac environment. Intensity-modulated radiation therapy (IMRT) treatment delivered with enabled deformation tracking was simulated and demonstrated. Results: The first experimental investigation of adapting to tumor deformation has been performed using simple deformable phantoms. For the single tumor deformation, the A{sub u}+A{sub o} was reduced over 56% when deformation was larger than 2 mm. Overall, the total improvement was 82%. For the tumor system deformation, the A{sub u}+A{sub o} reductions were all above 75% and the total A{sub u}+A{sub o} improvement was 86%. Similar coverage improvement was also found in simulating deformation tracking during IMRT delivery. The deformable image registration algorithm was identified as the dominant contributor to the tracking error rather than the finite leaf width. The discrepancy between the warped beam shape and the ideal beam shape due to the deformable registration was observed to be partially compensated during leaf fitting due to the finite leaf width. The clinical proof-of-principle experiment demonstrated the feasibility of intrafraction deformable tracking for clinical scenarios. Conclusions: For the first time, we developed and demonstrated an experimental system that is capable of adapting the MLC aperture to account for tumor deformation. This work provides a potentially widely available management method to effectively account for intrafractional tumor deformation. This proof-of-principle study is the first experimental step toward the development of an image-guided radiotherapy system to treat deforming tumors in real-time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and evaluation of a prototype tracking system using the treatment couch

Purpose: Tumor motion increases safety margins around the clinical target volume and leads to an increased dose to the surrounding healthy tissue. The authors have developed and evaluated a one-dimensional treatment couch tracking system to counter steer respiratory tumor motion. Three different motion detection sensors with different lag times were evaluated. Methods: The couch tracking system consists of a motion detection sensor, which can be the topometrical system Topos (Cyber Technologies, Germany), the respiratory gating system RPM (Varian Medical Systems) or a laser triangulation system (Micro Epsilon), and the Protura treatment couch (Civco Medical Systems). The control of the treatment couch was implemented in the block diagram environment Simulink (MathWorks). To achieve real time performance, the Simulink models were executed on a real time engine, provided by Real-Time Windows Target (MathWorks). A proportional-integral control system was implemented. The lag time of the couch tracking system using the three different motion detection sensors was measured. The geometrical accuracy of the system was evaluated by measuring the mean absolute deviation from the reference (static position) during motion tracking. This deviation was compared to the mean absolute deviation without tracking and a reduction factor was defined. A hexapod system was moving according to seven respiration patterns previously acquired with the RPM system as well as according to a sin{sup 6} function with two different frequencies (0.33 and 0.17 Hz) and the treatment table compensated the motion. Results: A prototype system for treatment couch tracking of respiratory motion was developed. The laser based tracking system with a small lag time of 57 ms reduced the residual motion by a factor of 11.9 ± 5.5 (mean value ± standard deviation). An increase in delay time from 57 to 130 ms (RPM based system) resulted in a reduction by a factor of 4.7 ± 2.6. The Topos based tracking system with the largest lag time of 300 ms achieved a mean reduction by a factor of 3.4 ± 2.3. The increase in the penumbra of a profile (1 × 1 cm{sup 2}) for a motion of 6 mm was 1.4 mm. With tracking applied there was no increase in the penumbra. Conclusions: Couch tracking with the Protura treatment couch is achievable. To reliably track all possible respiration patterns without prediction filters a short lag time below 100 ms is needed. More scientific work is necessary to extend our prototype to tracking of internal motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗