Automated Tracking of Shallow Cu Growth Rates on Geostationary Imagery and Linkages to Cloud Organization

Shallow moist convection is ubiquitous throughout the tropics and represents a key player in boundary layer processes. Common tropical cloud features, such as convective rolls and cold pool fronts, form and persist for different periods within environments that support such development. Determining differences in lifecycle amongst these features in varying environments requires viewing their evolution from initiation to decay. Geostationary satellites provide a means to follow the clouds with enhanced spatiotemporal sampling from space. We apply a cloud-tracking tool to study lifecycle properties of shallow cumulus sampled during the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP2Ex) field campaign of 2019. The mission conducted airborne and shipborne operations over the West Pacific Ocean, in tandem with Rapid Scan imagery from the Advanced Himawari Imager (AHI) on the Japan Meteorological Agency’s (JMA) Himawari-8 satellite. Shallow cumulus was segmented on AHI 0.5-km visible reflectance and tracked during the daylit hours of several research flights that exhibited ideal atmospheric conditions for tracking. The resulting cloud tracks were collected according to regions containing airborne sampling of individual clouds at various stages of their lifecycles, yielding ensembles of tracks in separate environments. We present an analysis on lifecycle properties extracted from the cloud-track ensembles and their potential connections to cloud organizations observed throughout CAMP2Ex. Each ensemble is evaluated by calculating cloud-layer growth rates and comparing to spatial parameters, including track-achieved area and cloud-top height. The apparent clustering of growth rates for specific ensembles is then compared against overall cloud organizations, such as isolated congestus and cold pool fronts, that are observed with the airborne data. Finally, we consider how such differences in cloud growth appear in the airborne radar observations of intercepted cloud tracks.

Cloud Tracking↗

Aspects of track-assisted mass

Track-assisted mass is a proxy for jet mass that only uses direction information from charged particles, allowing it to be measured at the Large Hadron Collider with very fine angular resolution. In this paper, we introduce a generalization of track-assisted mass and analyze its performance in both parton shower generators and resummed calculations. For the original track-assisted mass, the track-only mass is rescaled by the charged energy fraction of the jet. In our generalization, the rescaling factor includes both per-jet and ensemble-averaged information, facilitating a closer correspondence to ordinary jet mass. Using the track function formalism in electron-positron collisions, we calculate the spectrum of generalized track-assisted mass to next-to-leading-logarithmic order with leading-order matching. These resummed calculations provide theoretical insight into the close correspondence between track-assisted mass and ordinary jet mass. With the growing importance of jet grooming algorithms, we also calculate track-assisted mass on soft-drop groomed jets.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optofluidic solar concentrators using electrowetting tracking: Concept, design, and characterization

We introduce a novel optofluidic solar concentration system based on electrowetting tracking. With two immiscible fluids in a transparent cell, we can actively control the orientation of fluid fluid interface via electrowetting. The naturally-formed meniscus between the two liquids can function as a dynamic optical prism for solar tracking and sunlight steering. An integrated optofluidic solar concentrator can be constructed from the liquid prism tracker in combination with a fixed and static optical condenser (Fresnel lens). Therefore, the liquid prisms can adaptively focus sunlight on a concentrating photovoltaic (CPV) cell sitting on the focus of the Fresnel lens as the sun moves. Because of the unique design, electrowetting tracking allows the concentrator to adaptively track both the daily and seasonal changes of the sun's orbit (dual-axis tracking) without bulky, expensive and inefficient mechanical moving parts. This approach can potentially reduce capital costs for CPV and increases operational efficiency by eliminating the power consumption of mechanical tracking. Importantly, the elimination of bulky tracking hardware and quiet operation will allow extensive residential deployment of concentrated solar power. In comparison with traditional silicon-based photovoltaic (PV) solar cells, the electrowetting-based self-tracking technology will generate,similar to 70% more green energy with a 50% cost reduction. (C) 2013 Elsevier Ltd. All rights reserved.

Cheng, JT↗

Novel challenges in tracking self-interacting dark matter subhalos

Cosmological N-body simulations are among the primary tools for studying structure formation in the Universe. Analyses of these simulations critically depend on accurately identifying and tracking dark matter subhalos over time. In recent years, several new algorithms have been developed to improve the accuracy and consistency of subhalo tracking in cold dark matter (CDM) simulations. These algorithms should be revisited in the context of new physics beyond gravity, which can modify the evolution and final properties of subhalo populations. In this work, we apply the particle-tracking-based subhalo finder Symfind to velocity-dependent self-interacting dark matter (SIDM) simulations with large cross section amplitudes to assess the performance of particle-tracking methods beyond the CDM paradigm. We find that the core-particle-tracking technique, which is key to the success of these algorithms in CDM, does not always yield accurate results in SIDM. In particular, the interplay between dark matter self-interactions and tidal stripping can cause the diffusion of core particles to larger radii, leading particle-tracking-based algorithms to prematurely lose track of SIDM subhalos. For massive core-expansion subhalos and core-collapse subhalos that experience close or repeated pericentric passages, a significant fraction of core particles can be lost, and particle-tracking-based finders such as Symfind offer no clear advantage over traditional methods that rely on identifying phase-space overdensities. On the other hand, for subhalos with large pericentric distances or fewer, more distant passages, Symfind tends to outperform. These differences depend sensitively on the cross section amplitude and turnover velocity of the underlying SIDM model. We therefore recommend a hybrid approach that leverages the strengths of both techniques to produce complete and robust catalogs of core-expansion and core-collapse SIDM subhalos.

cosmological simulations↗

Minimum Cost Multi-way Data Association for Optimizing Multitarget Tracking of Interacting Objects

This paper presents a general formulation for a minimum cost data association problem which associates data features via one-to-one, m-to-one and one-to-n links with minimum total cost of the links. A motivating example is a problem of tracking multiple interacting nanoparticles imaged on video frames, where particles can aggregate into one particle or a particle can be split into multiple particles. Many existing multitarget tracking methods are capable of tracking non-interacting targets or tracking interacting targets of restricted degrees of interactions. The proposed formulation solves a multitarget tracking problem for general degrees of inter-object interactions. The formulation is in the form of a binary integer programming problem. We propose a polynomial time solution approach that can obtain a good relaxation solution of the binary integer programming, so the approach can be applied for multitarget tracking problems of a moderate size (for hundreds of targets over tens of time frames). The resulting solution is always integral and obtains a better duality gap than the simple linear relaxation solution of the corresponding problem. The proposed method was validated through applications to simulated multitarget tracking problems and a real multitarget tracking problem.

Binary Integer Programming↗

Four-dimensional dose distributions of step-and-shoot IMRT delivered with real-time tumor tracking for patients with irregular breathing: Constant dose rate vs dose rate regulation

Purpose: Dose-rate-regulated tracking (DRRT) is a tumor tracking strategy that programs the MLC to track the tumor under regular breathing and adapts to breathing irregularities during delivery using dose rate regulation. Constant-dose-rate tracking (CDRT) is a strategy that dynamically repositions the beam to account for intrafractional 3D target motion according to real-time information of target location obtained from an independent position monitoring system. The purpose of this study is to illustrate the differences in the effectiveness and delivery accuracy between these two tracking methods in the presence of breathing irregularities. Methods: Step-and-shoot IMRT plans optimized at a reference phase were extended to remaining phases to generate 10-phased 4D-IMRT plans using segment aperture morphing (SAM) algorithm, where both tumor displacement and deformation were considered. A SAM-based 4D plan has been demonstrated to provide better plan quality than plans not considering target deformation. However, delivering such a plan requires preprogramming of the MLC aperture sequence. Deliveries of the 4D plans using DRRT and CDRT tracking approaches were simulated assuming the breathing period is either shorter or longer than the planning day, for 4 IMRT cases: two lung and two pancreatic cases with maximum GTV centroid motion greater than 1 cm were selected. In DRRT, dose rate was regulated to speed up or slow down delivery as needed such that each planned segment is delivered at the planned breathing phase. In CDRT, MLC is separately controlled to follow the tumor motion, but dose rate was kept constant. In addition to breathing period change, effect of breathing amplitude variation on target and critical tissue dose distribution is also evaluated. Results: Delivery of preprogrammed 4D plans by the CDRT method resulted in an average of 5% increase in target dose and noticeable increase in organs at risk (OAR) dose when patient breathing is either 10% faster or slower than the planning day. In contrast, DRRT method showed less than 1% reduction in target dose and no noticeable change in OAR dose under the same breathing period irregularities. When {+-}20% variation of target motion amplitude was present as breathing irregularity, the two delivery methods show compatible plan quality if the dose distribution of CDRT delivery is renormalized. Conclusions: Delivery of 4D-IMRT treatment plans, stemmed from 3D step-and-shoot IMRT and preprogrammed using SAM algorithm, is simulated for two dynamic MLC-based real-time tumor tracking strategies: with and without dose-rate regulation. Comparison of cumulative dose distribution indicates that the preprogrammed 4D plan is more accurately and efficiently conformed using the DRRT strategy, as it compensates the interplay between patient breathing irregularity and tracking delivery without compromising the segment-weight modulation.

60 APPLIED LIFE SCIENCES↗

SU-D-18A-04: Quantifying the Ability of Tumor Tracking to Spare Normal Tissue

Purpose: Tumor tracking allows for smaller tissue volumes to be treated, potentially reducing normal tissue damage. However, tumor tracking is a more complex treatment and has little benefit in some scenarios. Here we quantify the benefit of tumor tracking for a range of patients by estimating the dose of radiation to organs at risk and the normal tissue complication probability (NTCP) for both standard and tracking treatment plans. This comparison is performed using both patient 4DCT data and extended Cardiac-Torso (XCAT) digital phantoms. Methods: We use 4DCT data for 10 patients. Additionally, we generate digital phantoms with motion derived from measured patient long tumor trajectories to compare standard and tracking treatment plans. The standard treatment is based on the average intensity projection (AIP) of 4DCT images taken over a breath cycle. The tracking treatment is based on doses calculated on images representing the anatomy at each time point. It is assumed that there are no errors in tracking the target. The NTCP values are calculated based on RTOG guidelines. Results: The mean reduction in the mean dose delivered was 5.5% to the lungs (from 7.3 Gy to 6.9 Gy) and 4.0% to the heart (from 12.5 Gy to 12.0 Gy). The mean reduction in the max dose delivered was 13% to the spinal cord (from 27.6 Gy to 24.0 Gy), 2.5% to the carina (from 31.7 Gy to 30.9 Gy), and 15% to the esophagus (from 69.6 Gy to 58.9 Gy). The mean reduction in the probability of 2nd degree radiation pneumonitis (RP) was 8.7% (3.1% to 2.8%) and the mean reduction in the effective volume was 6.8% (10.8% to 10.2%). Conclusions: Tumor tracking has the potential to reduce irradiation of organs at risk, and consequentially reduce the normal tissue complication probability. The benefits vary based on the clinical scenario. This study is supported by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

Sci—Sat AM: Stereo — 09: Accuracy of Liver Cancer Treatment on Cyberknife® with Synchrony™ Optical Tracking Throughout the Respiratory Cycle

The Cyberknife® robotic stereotactic body radiation therapy system is well-suited for treating liver lesions over the respiratory cycle as it includes room-mounted orthogonal x-ray tracking of internal fiducial markers and optical tracking of external markers. The Synchrony™ software generates a model of internal target positions during patient respiration and correlates it to the external optical tracking system for real-time optical-based position corrections of the linear accelerator during beam delivery. Although clinical studies have provided preliminary outcomes for liver lesions treated with the Cyberknife system, to date, there is little data demonstrating the ability of the Synchrony software to track targets in the liver, which deforms throughout the respiratory cycle. In this study, we investigated the respiratory motion model performance for predicting tumour motion. We conducted a retrospective analysis of fifteen liver cancer patients treated on the Cyberknife using the Synchrony optical tracking system. We analyzed Cyberknife tracking information stored in the log files to extract the left-right (LR), anterior-posterior (AP) and superior-inferior (SI) correlation errors between the model-predicted position and the internal fiducial centroid position determined by x-ray imaging. Only translational tracking and corrections were applied during treatment. Overall, the correlation errors were greatest in the SI direction. We calculated radial correlation errors, and determined that the 95{sup th}, 98{sup th} and 99{sup th} percentile errors were 3.4 mm, 4.4 mm and 5.1 mm, respectively. Based on translational correlation tracking errors we expect the clinical target volume will be within 3.4 mm of the planning target volume for 95 % of beam delivery time.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

60 APPLIED LIFE SCIENCES↗

Using dual-energy x-ray imaging to enhance automated lung tumor tracking during real-time adaptive radiotherapy

Purpose: Real-time, markerless localization of lung tumors with kV imaging is often inhibited by ribs obscuring the tumor and poor soft-tissue contrast. This study investigates the use of dual-energy imaging, which can generate radiographs with reduced bone visibility, to enhance automated lung tumor tracking for real-time adaptive radiotherapy. Methods: kV images of an anthropomorphic breathing chest phantom were experimentally acquired and radiographs of actual lung cancer patients were Monte-Carlo-simulated at three imaging settings: low-energy (70 kVp, 1.5 mAs), high-energy (140 kVp, 2.5 mAs, 1 mm additional tin filtration), and clinical (120 kVp, 0.25 mAs). Regular dual-energy images were calculated by weighted logarithmic subtraction of high- and low-energy images and filter-free dual-energy images were generated from clinical and low-energy radiographs. The weighting factor to calculate the dual-energy images was determined by means of a novel objective score. The usefulness of dual-energy imaging for real-time tracking with an automated template matching algorithm was investigated. Results: Regular dual-energy imaging was able to increase tracking accuracy in left–right images of the anthropomorphic phantom as well as in 7 out of 24 investigated patient cases. Tracking accuracy remained comparable in three cases and decreased in five cases. Filter-free dual-energy imaging was only able to increase accuracy in 2 out of 24 cases. In four cases no change in accuracy was observed and tracking accuracy worsened in nine cases. In 9 out of 24 cases, it was not possible to define a tracking template due to poor soft-tissue contrast regardless of input images. The mean localization errors using clinical, regular dual-energy, and filter-free dual-energy radiographs were 3.85, 3.32, and 5.24 mm, respectively. Tracking success was dependent on tumor position, tumor size, imaging beam angle, and patient size. Conclusions: This study has highlighted the influence of patient anatomy on the success rate of real-time markerless tumor tracking using dual-energy imaging. Additionally, the importance of the spectral separation of the imaging beams used to generate the dual-energy images has been shown.

60 APPLIED LIFE SCIENCES↗

Technical Note: Validation and implementation of a wireless transponder tracking system for gated stereotactic ablative radiotherapy of the liver

Purpose: Tracking soft-tissue targets has recently been cleared as a new application of Calypso, an electromagnetic wireless transponder tracking system, allowing for gated treatment of the liver based on the motion of the target volume itself. The purpose of this study is to describe the details of validating the Calypso system for wireless transponder tracking of the liver and to present the clinical workflow for using it to deliver gated stereotactic ablative radiotherapy (SABR). Methods: A commercial 3D diode array motion system was used to evaluate the dynamic tracking accuracy of Calypso when tracking continuous large amplitude motion. It was then used to perform end-to-end tests to evaluate the dosimetric accuracy of gated beam delivery for liver SABR. In addition, gating limits were investigated to determine how large the gating window can be while still maintaining dosimetric accuracy. The gating latency of the Calypso system was also measured using a customized motion phantom. Results: The average absolute difference between the measured and expected positional offset was 0.3 mm. The 2%/2 mm gamma pass rates for the gated treatment delivery were greater than 97%. When increasing the gating limits beyond the known extent of planned motion, the gamma pass rates decreased as expected. The 2%/2 mm gamma pass rate for a 1, 2, and 3 mm increase in gating limits was measured to be 97.8%, 82.9%, and 61.4%, respectively. The average gating latency was measured to be 63.8 ms for beam-hold and 195.8 ms for beam-on. Four liver patients with 17 total fractions have been successfully treated at our institution. Conclusions: Wireless transponder tracking was validated as a dosimetrically accurate way to provide gated SABR of the liver. The dynamic tracking accuracy of the Calypso system met manufacturer’s specification, even for continuous large amplitude motion that can be encountered when tracking liver tumors close to the diaphragm. The measured beam-hold gating latency was appropriate for targets that will traverse the gating limit each respiratory cycle causing the beam to be interrupted constantly throughout treatment delivery.

60 APPLIED LIFE SCIENCES↗

Large scale tracking algorithms

Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase signi cantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classfication steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

97 MATHEMATICS AND COMPUTING↗

Large Scale Tracking Algorithms

Low signal-to-noise data processing algorithms for improved detection, tracking, discrimination and situational threat assessment are a key research challenge. As sensor technologies progress, the number of pixels will increase significantly. This will result in increased resolution, which could improve object discrimination, but unfortunately, will also result in a significant increase in the number of potential targets to track. Many tracking techniques, like multi-hypothesis trackers, suffer from a combinatorial explosion as the number of potential targets increase. As the resolution increases, the phenomenology applied towards detection algorithms also changes. For low resolution sensors, "blob" tracking is the norm. For higher resolution data, additional information may be employed in the detection and classification steps. The most challenging scenarios are those where the targets cannot be fully resolved, yet must be tracked and distinguished for neighboring closely spaced objects. Tracking vehicles in an urban environment is an example of such a challenging scenario. This report evaluates several potential tracking algorithms for large-scale tracking in an urban environment.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Orbit determination with the tracking data relay satellite system

The possibility of employing the tracking data relay satellite system to satisfy the orbit determination demands of future applications missions is investigated. It is shown that when the relay satellites are continuously and independently tracked from ground stations it is possible, using six hour data arcs, to recover user satellite state with an average error of about 25 m radially, 260 m along track, and 20 m cross track. For this arc length, range sum data and range sum rate data are equally useful in determining orbits. For shorter arc lengths (20 min), range sum rate data is more useful than range sum data. When relay satellites are not continuously tracked, user satellite state can be recovered with an average error of about 140 m radially, 515 m along track, and 110 m cross track. These results indicate that the TDRS system can be employed to satisfy the orbit determination demands of applications missions, such as the MAGSAT and potential gradiometer missions, provided the relay satellites are continuously and independently tracked.

Argentiero, P.↗

Computer aided manual tracking

A scheme was developed to assist the human operator by augmenting an optic sight manual tracking loop with target rate estimates from a computer control algorithm which can either be a Kalman Filter or an alpha, beta, gamma filter. The idea is for the computer to provide rate tracking while the human operator is responsible for nullifying the tracking error. A simple schematic is shown to illustrate the implementation of this concept. A hybrid real-time man-in-loop simulation was used to compare the tracking performance of the same flight trajectory with or without this form of computer-aided track. Preliminary results show the advantage of computer-aided track against high speed aircraft at close range. However, good tracking before target state estimator maturity becomes more critical for aided track than without. Results are presented for a constant velocity flight trajectory.

Yin, Y. K.↗

Autonomous antenna tracking system for mobile symphonie ground stations

The implementation of a satellite tracking and antenna control system is described. Due to the loss of inclination control for the symphonie satellites, it became necessary to equip the parabolic antennas of the mobile Symphonie ground station with tracking facilities. For the relatively low required tracking accuracy of 0.5 dB, a low cost, step track system was selected. The step track system developed for this purpose and tested over a long period of time in 7 ground stations is based on a search step method with subsequent parabola interpolation. As compared with the real search step method, the system has the advantage of a higher pointing angle resolution, and thus a higher tracking accuracy. When the pilot signal has been switched off for a long period of time, as for instance after the eclipse, the antenna is repointed towards the satellite by an automatically initiated spiral search scan. The function and design of the tracking system are detailed, while easy handling and tracking results.

Ernsberger, K.↗

Method and apparatus for receiving and tracking phase modulated signals

An apparatus and technique are described for receiving and tracking analog or digital phase modulated signals from 0 deg to 360 deg phase shift. In order to track a signal with many phases, a detector discerns the phase modulation of the incoming signal and a phase shifter generates a negative phase shift opposite in angle to the detected phase angle. This produces a converted series sideband component barrier signal. The residual carrier signal and the converted series sideband component carrier are added together to produce a tracking carrier signal. The tracking carrier signal is multiplied with the output from a voltage controlled oscillator in the tracking loop to obtain an error signal which drives the voltage controlled oscillator and tracks the incoming signal frequency. The technique is less susceptible to carrier interference which may degrade tracking and tracking may be performed at lower signal to noise ratios and for lower input signal power levels.

Villarreal, S.↗

Hesitation in tracking induced by a concurrent manual task

When people are required to track with one hand and perform occasional discrete responses with the other hand, there is a strong possibility that errors will be induced in tracking attributable to the simultaneous action by the other. This problem was investigated by pairing pursuit tracking (right hand) with a handle movement response (left hand) guided by an auditory stimulus. Tracking is assumed to represent flight control and the left hand response to represent other aspects of aircraft system management. The general goal of this research is to identify the types of errors induced into tracking by the requirement of a secondary response with the other hand. An attempt is reported to determine if hesitations can be reduced further by combining tracking emphasis with a higher degree of practice. It is concluded that there is a tendency to freeze the tracking response when a discrete simultaneous response is required of the other hand. By contrast, practice seems to reduce hesitations while also improving left hand reaction time. Thus there appears to be a mode of control which permits tracking and discrete simultaneous responses to occur together.