Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Heat pipe cooled probe

The basic heat pipe principle is employed to provide a self-contained passively cooled probe that may be placed into a high temperature environment. The probe consists of an evaporator region of a heat pipe and a sensing instrument. Heat is absorbed as the working fluid evaporates in the probe. The vapor is transported to the vapor space of the condenser region. Heat is dissipated from the condenser region and fins causing condensation of the working fluid, which returns to the probe by gravity and the capillary action of the wick. Working fluid, wick and condenser configurations and structure materials can be selected to maintain the probe within an acceptable temperature range.

Camarda, C. J.↗

First measurements of electron temperature in the D region with a symmetric double probe

Measurement of the altitude profile of electron temperature in the ionospheric D region with the aid of a symmetric double probe flown on a Nike-Cajun payload launched on Oct. 13, 1971. The procedure for determining the electron temperature from the parameters of the double probe's current-voltage characteristic under conditions of nonnegligible ion-atom collision frequencies is described. It is shown that in its first lower ionospheric application the technique of the symmetric double probe has yielded the lowest values of electron temperature yet measured and has provided the very first direct measurement of electron temperature in the D region.

Szuszczewicz, E. P.↗

Electron temperature measurements using a 12-channel array probe

The most common technique for determining the mean kinetic energy of electrons in low-temperature plasmas utilizes the so-called Langmuir probe. The present investigation is concerned with the study of the electron temperature in a pulsed high-beta plasma as a function of time by means of a miniature array of 12 planar Langmuir probes. By using a probe with many individually collecting surfaces, each biased at a different fixed voltage, an approximation to the true probe characteristic is obtained when monitoring the collected currents for each independent subprobe. The employed method, by using many points, provides enough information to reconstruct the entire I-V curve. Attention is given to the principle of operation of the new probe, calibration, accuracy, time resolution, and applications of the new method. By employing two probes it is possible to perform correlation measurements to study heat flow and temperature fluctuations.

Wild, N.↗

In-stream measurements of combustion during Mach 5 to 7 tests of the Hypersonic Research Engine (HRE)

Results of in-stream combustion measurements taken during Mach 5 to 7 true simulation testing of the Hypersonic Research Engine/Aerothermodynamic Integration Model (HRE/AIM) are presented. These results, the instrumentation techniques, and configuration changes to the engine installation that were required to test this model are described. In test runs at facility Mach numbers of 5 to 7, an exhaust instrumentation ring which formed an extension of the engine exhaust nozzle shroud provided diagnostic measurements at 10 circumferential locations in the HRE combustor exit plane. The measurements included static and pitot pressures using conventional conical probes, combustion gas temperatures from cooled-gas pyrometer probes, and species concentration from analysis of combustion gas samples. Results showed considerable circumferential variation, indicating that efficiency losses were due to nonuniform fuel distribution or incomplete mixing. Results using the Mach 7 facility nozzle but with Mach 6 temperature simulation, 1590 to 1670 K, showed indications of incomplete combustion. Nitric oxide measurements at the combustor exit peaked at 2000 ppmv for stoichiometric combustion at Mach 6.

Lezberg, Erwin A.↗

The effect of an isotopic non-equilibrium plasma on electron temperature measurements

Electron temperatures determined by electrostatic probe, diffuse resonance, and radar backscatter techniques in an isotropic two temperature plasma are presented. Plasma models corresponding to the addition of a minor component of energetic electrons, and models corresponding to a process that cools a fraction of the ionospheric electrons are considered. The diffuse resonance temperature is found to lie between the probe and radar backscatter temperatures. The isotropic models corresponding to the addition of energetic electrons cannot support the reported discrepancies between radio wave and probe electron temperature measurements. Temperature differences similar to the observed differences can be produced by models with a fraction of the electrons at a temperature cooler than that of the main component of electrons.

Benson, R. F.↗

Cooling method prolongs life of hot-wire transducer

To cool a hot-wire transducer, the two ends of the wire are supported on thermally and electrically conductive rods, surrounded by a fluid cooling medium. By keeping the supporting rods at a substantially constant temperature, the probe is prevented from overheating.

Baldwin, L. V.↗

Millivolt signal limiter

Low-voltage limiter circuit suppresses the output of platinum probes at temperatures beyond their operating range. The limiter circuit comprises an operational amplifier with a dual feedback loop. The signal limiter is useful in low-voltage instrumentation circuits normally operable or set for cryogenic temperatures.

Hansen, I. G.↗

System design of the Pioneer Venus spacecraft. Volume 7: Communication subsystem studies

Communications subsystem tradeoffs were undertaken to establish a low cost and low weight design consistent with the mission requirements. Because of the weight constraint of the Thor/Delta launched configuration, minimum weight was emphasized in determining the Thor/Delta design. In contrast, because of the greatly relaxed weight constraint of the Atlas/Centaur launched configuration, minimum cost and off the shelf hardware were emphasized and the attendant weight penalities accepted. Communication subsystem hardware elements identified for study included probe and bus antennas (CM-6, CM-17), power amplifiers (CM-10), and the large probe transponder and small probe stable oscillator required for doppler tracking (CM-11, CM-16). In addition, particular hardware problems associated with the probe high temperature and high-g environment were investigated (CM-7).

Newlands, D. M.↗

Stark broadening of Balmer lines in the density range /2-8/ x 10 to the 14/cu cm

Experimental profiles of the hydrogen Balmer lines (H gamma-H sub 10) have been measured over the density range (2-8) x 10 to the 14/cu cm and compared with theoretical profiles. Electron densities were measured using a multipass interferometer, while plasma homogeneity was demonstrated using a Langmuir probe. Electron temperatures were in the range 1-2.0 eV. The electron density as deduced from line profiles tended to be as much as 10% lower than that from the interferometer at higher densities. At lower densities, the two methods agreed to within experimental error. Evidence for asymmetries on the line wings was noted.

Bengtson, R. D.↗

Studies of low-mass star formation with the large deployable reflector

Estimates are made of the far-infrared and submillimeter continuum and line emission from regions of low mass star formation. The intensity of this emission is compared with the sensitivity of the large deployable reflector (LDR), a large space telescope designed for this wavelength range. The proposed LDR is designed to probe the temperature, density, chemical structure, and the velocity field of the collapsing envelopes of these protostars. The LDR is also designed to study the accretion shocks on the cores and circumstellar disks of low-mass protostars, and to detect shock waves driven by protostellar winds.

Hollenbach, D. J.↗

Measuring Thicknesses of Wastewater Films

Sensor determines when thickness of film of electrically conductive wastewater on rotating evaporator drum exceeds preset value. Sensor simple electrical probe that makes contact with liquid surface. Made of materials resistant to chemicals in liquid. Mounted on shaft in rotating cylinder, liquid-thickness sensor extends toward cylinder wall so tip almost touches. Sensor body accommodates probe measuring temperature of evaporated water in cylinder.

Schubert, F. H.↗

Theoretical infrared spectra of SN 1987A

A simple model for the ejecta of SN 1987A is used to show that the expected fluxes in infared fine structure lines from nickel, cobalt, iron, argon, sulfur, silicon, and neon are likely to be detectable for several years following the supernova explosion. Energy sources due to radioactive decay and a central pulsar are considered separately. Most of the mass of heavy elements resides in the inner, pure metal shells of the ejecta, so that the infrared lines will probe the temperature, ejecta masses, and dynamics of this region and not the overlying, hydrogen-rich envelope.

Colgan, Sean W. J.↗

An experimental study of shock wave/vortex interaction

The interaction of a supersonic streamwise vortices (of Mach number 2.2, 3.0, and 3.5) with a normal shock wave has been experimentally investigated, and is found to be highly unsteady. Five-hole pressure-probe and temperature measurements ahead of the interaction are used as initial conditions for an axisymmetric Navier-Stokes calculation. The numerical results supports the hypothesis that supersonic vortex breakdown is an important factor in the observed interaction flow pattern.

Metwally, O. M.↗

Room-temperature InGaAs detector arrays for 2.5 microns

This paper describes new alloy heterojunction detectors of In(.8)Ga(.2)As/InAs(.6)P(.4) which can detect light between 1.7 and 2.6 microns with 50 percent quantum efficiency and 5 mA/sq cm dark current (-1 V) density at room temperature. Wafer probe data showed that over 50 good contiguous 100 micron diameter devices (spaced 400 microns) could be made on a 25 x 30 mm wafer with overall yield above 93 percent. The ability to operate under -1 V reverse bias makes these devices ideally compatible with existing commercial multiplexer readouts.

Olsen, G. H.↗

Probe For Measuring Dynamic Gas Temperature In Reversing Flows

In proposed technique for determining time-varying temperature of flowing gas, raw measurements of three thermocouples of different sizes processed by relatively simple data-reduction software. Three-thermocouple technique overcomes limitation of single-thermocouple technique.

Fralick, Gustave C.↗