Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Storage ring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Study of Fluctuations in Undulator Radiation in the IOTA Ring at Fermilab

We study turn-by-turn fluctuations in the number of emitted photons in an undulator, installed in the IOTA electron storage ring at Fermilab, with an InGaAs PIN photodiode and an integrating circuit. In this paper, we present a theoretical model for the experimental data from previous similar experiments and in our present experiment, we attempt to verify the model in an independent and a more systematic way. Moreover, in our experiment we consider the regime of very small fluctuation when the contribution from the photon shot noise is significant, whereas we believe it was negligible in the previous experiments. Accordingly, we present certain critical improvements in the experimental setup that let us measure such a small fluctuation.

43 PARTICLE ACCELERATORS↗

Beam and Spin Optics Simulation Tutorials, Using Zgoubi Exercises and Solutions 2 - RHIC Run 22 Spin Transparency Experiment

High electron and ion polarizations are paramount design requirements for the future Electron Ion Collider (EIC) at BNL. A “spin transparency” mode of operation, inherited from the “figure-8” ring design [1], allows preservation and control of electron and ion spin polarization in a collider or storage ring [2, 3]. It makes the ring lattice “invisible” to the spin and allows for polarization control by small quasi-static magnetic fields with practically no effect on beam orbital parameters. Beam polarization can then be fully controlled by small adjustments of snake axis orientation (a few degrees) and snake strengths (a few percent); polarization orientation at IPs can be controlled without spin rotators, spins can be adiabatically flipped without the need of ac magnets. The transparent spin mode has been demonstrated in simulations [2] for the purpose of being tested experimentally during RHIC Run 22. This experiment was aimed at providing data to validate the principles. Yellow RHIC ring (Fig. 1.1) was configured in the transparent spin mode by aligning the axes of its two helical snakes (located respectively in the 3 o’clock and 9 o’clock sextants) parallel to the longitudinal axis. Experiment goals and expected results, ad hoc procedures and hardware requirements, are addressed in Refs. [2, 3].

43 PARTICLE ACCELERATORS↗

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057↗

The design of Optical Stochastic Cooling for IOTA

This report presents a journal version of the Design Report on the Optical Stochastic Cooling experiment to be carried out at IOTA ring in Fermilab later this year. It discusses the theory which experiment is based on, beam parameters, major requirements to the storage ring systems and technical details of the experiment implementation.

Instrumentation for particle accelerators↗

Linear Modelling from Betatron Phase Measurements at the Fermilab Recycler NOvA ring

Utilizing the measurement of coherent betatron oscillation phase has emerged as fast and precise approach for identifying and rectifying errors in implementing a desired lattice in CESR (Cornell Electron Storage Ring). One key advantage of betatron phase measurement over β measurement is its sensitivity to phase variations between widely separated points. This methodology has been successfully implemented for the Recycler NOvA Ring at Fermilab, with the adoption of TAO (Tool for Accelerator Optics) developed by Cornell University. By employing this technique, a linear model of the Recycler NOvA ring is established, enabling the correction of quadrupole errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Damping Ring for the Rapid Cycling Synchrotron

The Electron-Ion Collider (EIC) electron accelerator chain consists of a 400 MeV electron Linear Accelerator (LINAC), the Rapid Cycling Synchrotron (RCS), and the Electron Storage Ring (ESR). The LINAC injects into the RCS, the RCS ramps to a top energy of 18 GeV and the electron beam is extracted to the ESR. To minimize the momentum spread of the 400 MeV injected beam and serve as a 28 nC electron accumulator ring, a damping ring is proposed. This ring may also serve as an intermediate energy booster for the RCS. The damping ring is not within the current baseline of the EIC project.

43 PARTICLE ACCELERATORS↗

Magnetic Field Analysis for Fermilab Muon $g-2$

The Muon g-2 experiment E989 at Fermilab measures the anomalous magnetic moment of the muon $a_\mu$ with improved precision compared to the Brookhaven (E821) experiments. The Brookhaven results are in tension with the Standard Model by more than $3\sigma$. The determination of $a_\mu$ requires the measurement of both the muon anomaly frequency, $\omega_a$, and the magnetic field, $\mathbf{B}$, that confines muons in a storage ring. The field is monitored by a set of coordinated nuclear magnetic resonance (NMR) measurements. NMR probes at fixed locations above and below the storage region constantly monitor the field. An in-vacuum trolley equipped with 17 NMR probes maps the muon storage region, and a special water-based NMR probe provides the calibration for the trolley probes. This presentation focuses on the determination of the time-dependent field maps from combining the fixed probe measurements and the trolley maps. The field maps are combined with the muon distribution to derive the average field observed by the muons during the measurement. These proceedings will cover the analysis from the first data run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Schottky Tune Meter for the Fermilab Mu2E Delivery Ring

The Mu2E experiment will measure the ratio of the rate of the neutrinoless, coherent conversion of muons into electrons as a measure of Charged Lepton Flavor Violation. As part of the Mu2E experiment, a proton storage ring, called the Delivery Ring, will utilize resonant extraction to slow-spill protons to the experiment. To regulate and optimize the Delivery Ring resonant extraction process, a fast tune measurement scheme will be required. This Mu2E tune meter will measure the average tune and the tune spectrum, in multiple time slices, through the entire resonant extraction cycle of nominally 43 msec. The Mu2E tune meter system utilizes vertical and horizontal 21.4 MHz Schottky detector resonant pickups, taken from the decommissioned Tevatron, high-gain amplifiers and digital down-conversion FPGA logic for its signal processing. This paper will present the design of this Schottky tune meter as well as tune measurements from the Mu2E delivery ring.

43 PARTICLE ACCELERATORS↗

3D small-gain formula allowing strong focusing and harmonic lasing for a ring-based x-ray free electron laser oscillator

We present a detailed derivation of a formula for the small-gain calculation for an x-ray free electron laser oscillator (XFELO) based on a medium-energy (3–4 GeV) storage ring. We found harmonic lasing and strong focusing are essential for this beam energy range. Taking the small-signal low-gain formula developed by Kim and his colleagues, we modified it in such a way that the gain can be calculated without the “no focusing approximation,” and a strong focusing can be applied, as well as harmonic lasing. In this formula, the gain is represented as a product of two factors with one of them depending only on the harmonic number, undulator period, and gap. Using this factor, we show that it is favorable to use harmonic lasing to achieve hard x-ray FEL working in the small-signal low-gain regime with the medium-energy electron beam. Our formula also allows FEL optimization by varying the vertical gradient of the undulator, the vertical dispersion, and the horizontal and vertical focusing, independently. As an example, we applied this formula to study the feasibility of an XFELO option for the National Synchrotron Light Source II (NSLS-II) upgrade. Since a quite high peak current is required for the FEL, collective effects of beam dynamics in medium-energy synchrotrons significantly affect the electron beam parameters. We carried out a multiparameter optimization taking collective effects into account. Note, even though our example is for a ring-based XFELO at 3 to 4 GeV, the formula and, in particular, the approach developed here may be applied to other types of FELs. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Optical Properties of Wigglers for EIC Ring Electron Cooler

Electron Ion Collider (EIC) requires cooling of protons at top energy (275 GeV) to achieve the average design luminosity. Such a cooler must be capable of counteracting an IBS-driven emittance growth in proton bunches. The Ring Electron Cooler (REC) is a candidate for the EIC top energy cooler. The REC is a non-magnetized RF-based 150 MeV electron cooler, in which electrons are kept in the storage ring and re-utilized for several million turns. The REC is equipped with 18 damping wigglers, which keep electrons’ emittance constant by counteracting both electrons’ IBS and a proton electron beam-beam scattering happening in the cooling section. These wigglers operate at a relatively low energy but must have a rather high field to provide the required radiation cooling of electrons. As a result of this unique range of parameters, the wigglers’ optics exhibits interesting features The actual design parameters of the wigglers will be finalized in the REC lattice optimization.

43 PARTICLE ACCELERATORS↗

Empowering Scientific Discovery Through Computing at the Advanced Photon Source

This paper explores the challenges and solutions for managing and processing the vast amount of data generated by the Advanced Photon Source (APS), a synchrotron light source facility producing ultra-bright x-rays for diverse scientific domains. With 68 experimental beamlines covering materials research, biology, and more, the APS serves a wide user base across academia, government, and industry. The ongoing upgrade of the APS storage ring and installation of new instruments will amplify data generation and processing demands. This paper discusses the approach to address these demands through automated data processing using standardized workflows that produce faster scientific insights. The APS Data Management System coordinates various data related tasks to manage storage, data transfer, metadata cataloging, data processing, and interfaces with tools provided by Globus. Through integration with the Argonne Leadership Computing Facility (ALCF), APS users can efficiently access high-performance computing resources. Standardized workflows have led to reduced computational burdens on scientists and greater accessibility of high performance computing resources. We demonstrate how standardization and collaboration enable scientists to rapidly convert raw data into meaningful scientific results, establishing a streamlined path from data collection to analysis and ultimately to publication.

Parraga, Hannah↗

Analytical estimates of beam intensity limitations in the EIC Beam Accumulator Ring

This report summarizes analytical estimates of beam intensity limitations in the Beam Accumulator Ring (BAR), a part of the Electron-Ion Collider injector complex under development at Brookhaven National Laboratory. The BAR is designed to accumulate a polarized electron beam with a single-bunch charge up to 28 nC for subsequent acceleration in the Rapid Cycling Synchrotron and then injection into the Electron Storage Ring. Analytical models of longitudinal and transverse collective effects are developed using a broadband impedance model calibrated with the beam-based measurement results from NSLS VUV. The study evaluates the impact of resistive-wall and geometric impedances, assessing microwave and transverse mode coupling instabilities, bunch lengthening, and beam-induced heating.

43 PARTICLE ACCELERATORS↗

Dissociative electron recombination and rotational cooling of the deuterated triatomic hydrogen ions H 2 ⁡D + and D 2 ⁢H +

We have measured the dissociative recombination (DR) of the deuterated triatomic hydrogen ions H 2 ⁡D + and D 2 ⁢H + as a function of storage time at the Cryogenic Storage Ring (CSR). Both molecular ions were stored for up to 1000 s inside the cryogenic vacuum of the CSR prior to the electron recombination measurements, allowing them to cool to their lowest rotational states. We implement a comprehensive model for all relevant processes to predict the internal state evolution of the ions during storage inside the CSR, employing calculated radiative transition strengths and state-selective rate coefficients for electron collisions. Our DR rate coefficient measurements with deuterated triatomic hydrogen ions in defined quantum states allow for meaningful comparisons with state-of-the-art theoretical calculations, paving the way for a better understanding of the complex DR process for polyatomic molecular ions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical stochastic cooling at Fermilab’s IOTA ring

Stochastic cooling (SC) constitutes one of the greatest conceptual and technological achievements in particle beam cooling. Numerous SC systems have been built in the microwave regime and used to extend the science reach of accelerator facilities worldwide. The ability to sense and correct the particle ensemble using high-bandwidth feedback systems is at the core of the concept. Here, we describe the first realization of SC at optical frequencies and bandwidths. The demonstration was recently carried out at Fermilab’s integrable optics test accelerator (IOTA) storage ring using the transit-time method of optical stochastic cooling (OSC) and achieved an integrated system bandwidth of approximately 20 THz, which is more than 2000 times that of conventional SC systems. This demonstration establishes the foundation for more advanced OSC experiments with high-gain amplification, currently underway at Fermilab, and the eventual application of OSC to colliders and other accelerator facilities.

Jarvis, Jonathan D. [Fermilab]↗

First Results of the IOTA Ring Research at Fermilab

The IOTA ring at Fermilab is a unique machine exclusively dedicated to accelerator beam physics R&D. The research conducted at IOTA includes topics such as nonlinear integrable optics, suppression of coherent beam instabilities, optical stochastic cooling and quantum science experiments. In this talk we report on the first results of experiments with implementations of nonlinear integrable beam optics. The first of its kind practical realization of a two-dimensional integrable system in a strongly-focusing storage ring was demonstrated allowing among other things for stable beam circulation near or at the integer resonance. Also presented will be the highlights of the world’s first demonstration of optical stochastic beam cooling and other selected results of IOTA’s broad experimental program.

43 PARTICLE ACCELERATORS↗

Linear optics compensation for the HEX superconducting wiggler at NSLS-II

At the NSLS-II ring, a 1.2 m long superconducting wiggler with the maximum 4.34T magnetic field has been installed at a low-β straight section (cell 27) to drive the high energy engineering X-ray scattering (HEX) beamline. To mitigate the potential performance degradation due to the linear optics distortion, a local compensation scheme was adopted and confirmed with the online beam measurement. A feedforward control to enable a dynamic compensation of the linear optics distortion was deployed. It can maintain the storage ring lattice performance when the device main coil current ramps.

36 MATERIALS SCIENCE↗

On the Possibility of Installing the Rapid Cycling Synchrotron of the Electron Ion Collider in the AGS Tunnel

This report describes electron injector concepts for the Electron Ion Collider (EIC) using the tunnel of the Alternating Gradient Synchrotron (AGS) of Brookhaven National Laboratory which is to be compared to the RCS in the RHIC tunnel or a new ring in a new tunnel. Possible designs of the electron booster synchrotron, the Rapid Cycling Synchrotron (RCS) with good spin transparency with electron energies of up to 10 GeV and 18 GeV and placing the injector linac in the adjacent Building 912 for are worked out. The main reason for studying such options is the expectation that it will reduce the Electron Ion Collider injector cost because no civil construction is required, the machine is very compact, and existing infrastructure can be used. The design of an RCS with a top energy of 10 GeV with good spin transparency is quite conventional. However, for collider operation with 18 GeV electrons, this option would require accelerating the 10 GeV beam in the Electron Storage Ring (ESR) to 18 GeV and relying on the Sokolov Ternov self-polarization at 18 GeV in the ESR. Solutions for an RCS with Electron energies of up to 18 GeV with or without spin transparency are found to be possible but push the envelope of conventional magnet technology.

43 PARTICLE ACCELERATORS↗

Beam Dynamics of the Muon $g\textrm{-}2$ Experiment

The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab aims to measure the muon anomalous magnetic moment $a_{\mu}$ with unprecedented precision, potentially uncovering physics beyond the Standard Model of particle physics. The result based on Runs 1-3, released in 2023, achieved a precision of 0.20 ppm. The experiment circulates muons in a storage ring, measuring $a_{\mu}$ from decay positron time and energy measurements collected with calorimeters. To achieve the required accuracy, it is crucial to measure and control the magnetic field in the ring with high precision. Beam dynamics corrections are necessary for muons not orbiting exactly in the midplane, for their oscillations, and for electric field effects. Highly accurate beam dynamics simulations are instrumental for quantifying and validating the beam dynamics corrections, ultimately improving the precision of the $a_{\mu}$ measurement and facilitating the achievement of the ambitious $70\:\mathrm{ppb}$ systematic uncertainty goal. The measured field data was incorporated into models for simulations using three codes: \texttt{gm2ringsim} (an internal Geant4-based code), \textit{COSY INFINITY}, and \textit{BMAD}. The advantages of \texttt{gm2ringsim} include using CAD-based geometry and modelling the detector effects. \textit{COSY INFINITY} is a highly accurate and efficient code that uses high-order differential-algebraic transfer maps, precise fringe field calculations, and advanced symplectification methods. Symplectification is important for maintaining the physical correctness of the muon beam behaviour with high precision over the storage time, ensuring conservation of phase space volume and preventing artificial damping or excitation of particle motion. The experiment completed its final Run 6 in July 2023, collecting 21 times more data than the previous BNL experiment. Analyses of data from Runs 4-6 are ongoing, with results planned for release in 2025, potentially resolving the current tension between experiment and theory.

43 PARTICLE ACCELERATORS↗