Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Step”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY↗

A Two-Step PCR Protocol Enabling Flexible Primer Choice and High Sequencing Yield for Illumina MiSeq Meta-Barcoding

High-throughput amplicon sequencing that primarily targets the 16S ribosomal DNA (rDNA) (for bacteria and archaea) and the Internal Transcribed Spacer rDNA (for fungi) have facilitated microbial community discovery across diverse environments. A three-step PCR that utilizes flexible primer choices to construct the library for Illumina amplicon sequencing has been applied to several studies in forest and agricultural systems. The three-step PCR protocol, while producing high-quality reads, often yields a large number (up to 46%) of reads that are unable to be assigned to a specific sample according to its barcode. Here, we improve this technique through an optimized two-step PCR protocol. We tested and compared the improved two-step PCR meta-barcoding protocol against the three-step PCR protocol using four different primer pairs (fungal ITS: ITS1F-ITS2 and ITS1F-ITS4, and bacterial 16S: 515F-806R and 341F-806R). We demonstrate that the sequence quantity and recovery rate were significantly improved with the two-step PCR approach (fourfold more read counts per sample; determined reads ≈90% per run) while retaining high read quality (Q30 > 80%). Given that synthetic barcodes are incorporated independently from any specific primers, this two-step PCR protocol can be broadly adapted to different genomic regions and organisms of scientific interest.

16S rDNA↗

A comparison of artificial compressibility and fractional step methods for incompressible flow computations

We have applied and compared the efficiency and accuracy of two commonly used numerical methods for the solution of Navier-Stokes equations. The artificial compressibility method augments the continuity equation with a transient pressure term and allows one to solve the modified equations as a coupled system. Due to its implicit nature, one can have the luxury of taking a large temporal integration step at the expense of higher memory requirement and larger operation counts per step. Meanwhile, the fractional step method splits the Navier-Stokes equations into a sequence of differential operators and integrates them in multiple steps. The memory requirement and operation count per time step are low, however, the restriction on the size of time marching step is more severe. To explore the strengths and weaknesses of these two methods, we used them for the computation of a two-dimensional driven cavity flow with Reynolds number of 100 and 1000, respectively. Three grid sizes, 41 x 41, 81 x 81, and 161 x 161 were used. The computations were considered after the L2-norm of the change of the dependent variables in two consecutive time steps has fallen below 10(exp -5).

Chan, Daniel C.↗

Laser holographic interferometric measurements of the flow behind a rearward facing step

A holographic interferometer has been designed, constructed, and evaluated in an experimental study of the supersonic flow over a rearward facing step. The nominal Mach number at the corner was 2.05 +/- 0.04 and the Reynolds number per inch was 11.9 x 10 exp 6. The holographic interferometric measurements were supplemented by classical measurements of surface pressure, oil flow, and schlieren visualization. The effects of step height and step width were examined. A method to determine the reattachment point from the interferograms was examined and found to be in good agreement with the other measurement techniques. The reattachment point moved closer to the step as the step height was decreased, but its location did not change with varying step width. In addition to providing surface data for the flow over a rearward facing step, this study provides quantitative off-surface density data and Mach number data throughout the flow, obtained from the holographic interferometry measurements, which are suited for code validation.

Leonard, Rachel↗

Stepping-Motor Drive Suppresses Torsional Oscillation

Excitation in stepping-motor drive differs from conventional excitation in that each step is divided into two equal smaller steps separated by small interval, tau. Interval chosen to equal half period of torsional oscillation, so second step excitation equal in amplitude but opposite in phase to first step excitation. Thus, although first step unavoidably excites torsional oscillation, second step deexcites oscillation at end of first half cycle.

Bhat, Mahabaleshwar K. P.↗

Effects of Adverse Pressure Gradient on the Incompressible Reattaching Flow Over a Rearward-Facing Step

The turbulent, incompressible reattaching flow over a rearward-facing step has been studied by many researchers over the years. One of the principal quantities determined in these experiments has been the distance from the step to the point (or region) where the separated shear layer reattaches to the surface (x(r)). The values for x(r)/h, where h is the step height, have covered a wider range than can reasonably be attributed to experimental technique or inaccuracy. Often the reason for a largely different value of x(r)/h can be attributed to an incompletely developed turbulent layer, or a transitional or laminar boundary layer. However, for the majority of experiments where the boundary layer is believed to be fully developed and turbulent, x(r)/h still varies several step heights; generally, 5 1/2 approximately < x(r)/h approximately < 7 1/2. This observed variation has usually been attributed to such variables as l/h (step length to height, h/delta (step height to initial boundary-layer thickness), R(e)(theta)), or the experimental technique for determining reattachment location. However, there are so many different combinations of variables in the previous experiments that it was not possible to sort out the effects of particular conditions on the location of reattachment. In the present experiment velocity profiles have been measured in and around the region of separated flow. Results show a large influence of adverse pressure gradient on the reattaching flow over a rearward-facing step that has not been reported previously. Further, the many previous experiments for fully developed, turbulent flow in parallel-walled channels have shown a range of reattachment location that has not been explained by differences in initial flow conditions. Although these initial flow conditions might contribute to the observed variation of reattachment location, it appears that the pressure gradient effect can explain most of that variation.

Kuehn, Donald M.↗

Volume Diffusion Growth Kinetics and Step Geometry in Crystal Growth

The role of step geometry in two-dimensional stationary volume diff4sion process used in crystal growth kinetics models is investigated. Three different interface shapes: a) a planar interface, b) an equidistant hemispherical bumps train tAx interface, and c) a train of right angled steps, are used in this comparative study. The ratio of the super-saturation to the diffusive flux at the step position is used as a control parameter. The value of this parameter can vary as much as 50% for different geometries. An approximate analytical formula is derived for the right angled steps geometry. In addition to the kinetic models, this formula can be utilized in macrostep growth models. Finally, numerical modeling of the diffusive and convective transport for equidistant steps is conducted. In particular, the role of fluid flow resulting from the advancement of steps and its contribution to the transport of species to the steps is investigated.

Mazuruk, Konstantin↗

New Reduced Two-Time Step Method for Calculating Combustion and Emission Rates of Jet-A and Methane Fuel With and Without Water Injection

A simplified kinetic scheme for Jet-A, and methane fuels with water injection was developed to be used in numerical combustion codes, such as the National Combustor Code (NCC) or even simple FORTRAN codes that are being developed at Glenn. The two time step method is either an initial time averaged value (step one) or an instantaneous value (step two). The switch is based on the water concentration in moles/cc of 1x10(exp -20). The results presented here results in a correlation that gives the chemical kinetic time as two separate functions. This two step method is used as opposed to a one step time averaged method previously developed to determine the chemical kinetic time with increased accuracy. The first time averaged step is used at the initial times for smaller water concentrations. This gives the average chemical kinetic time as a function of initial overall fuel air ratio, initial water to fuel mass ratio, temperature, and pressure. The second instantaneous step, to be used with higher water concentrations, gives the chemical kinetic time as a function of instantaneous fuel and water mole concentration, pressure and temperature (T4). The simple correlations would then be compared to the turbulent mixing times to determine the limiting properties of the reaction. The NASA Glenn GLSENS kinetics code calculates the reaction rates and rate constants for each species in a kinetic scheme for finite kinetic rates. These reaction rates were then used to calculate the necessary chemical kinetic times. Chemical kinetic time equations for fuel, carbon monoxide and NOx were obtained for Jet-A fuel and methane with and without water injection to water mass loadings of 2/1 water to fuel. A similar correlation was also developed using data from NASA's Chemical Equilibrium Applications (CEA) code to determine the equilibrium concentrations of carbon monoxide and nitrogen oxide as functions of overall equivalence ratio, water to fuel mass ratio, pressure and temperature (T3). The temperature of the gas entering the turbine (T4) was also correlated as a function of the initial combustor temperature (T3), equivalence ratio, water to fuel mass ratio, and pressure.

Molnar, Melissa↗

Steps in Solution Growth: Revised Gibbs-Thomson Law, Turbulence and Morphological Stability

Two groups of new phenomena revealed by AFM and high resolution optical interferometry on crystal faces growing from solutions will be discussed. 1. Spacing between strongly polygonized spiral steps with low less than 10(exp -2) kink density on lysozyme and K- biphtalate do not follow the Burton-cabrera-Frank theory. The critical length of the yet immobile first Short step segment adjacent to a pinning defect (dislocation, stacking fault) is many times longer than that following from the step free energy. The low-kink density steps are typical of many growth conditions and materials, including low temperature gas phase epitaxy and MBE. 2. The step bunching pattern on the approx. 1 cm long { 110) KDP face growing from the turbulent solution flow (Re (triple bonds) 10(exp 4), solution flow rate approx. 1 m/s) suggests that the step bunch height does not increase infinitely as the bunch path on the crystal face rises, as is usually observed on large KDP crystals. The mechanism controlling the maximal bunch width and height is based on the drag of the solution depleted by the step bunch down thc solution stream. It includes splitting, coagulation and interlacing of bunches

Chernov, A. A.↗

Simplified Two-Time Step Method for Calculating Combustion and Emission Rates of Jet-A and Methane Fuel With and Without Water Injection

A simplified kinetic scheme for Jet-A, and methane fuels with water injection was developed to be used in numerical combustion codes, such as the National Combustor Code (NCC) or even simple FORTRAN codes. The two time step method is either an initial time averaged value (step one) or an instantaneous value (step two). The switch is based on the water concentration in moles/cc of 1x10(exp -20). The results presented here results in a correlation that gives the chemical kinetic time as two separate functions. This two time step method is used as opposed to a one step time averaged method previously developed to determine the chemical kinetic time with increased accuracy. The first time averaged step is used at the initial times for smaller water concentrations. This gives the average chemical kinetic time as a function of initial overall fuel air ratio, initial water to fuel mass ratio, temperature, and pressure. The second instantaneous step, to be used with higher water concentrations, gives the chemical kinetic time as a function of instantaneous fuel and water mole concentration, pressure and temperature (T4). The simple correlations would then be compared to the turbulent mixing times to determine the limiting rates of the reaction. The NASA Glenn GLSENS kinetics code calculates the reaction rates and rate constants for each species in a kinetic scheme for finite kinetic rates. These reaction rates are used to calculate the necessary chemical kinetic times. Chemical kinetic time equations for fuel, carbon monoxide and NOx are obtained for Jet-A fuel and methane with and without water injection to water mass loadings of 2/1 water to fuel. A similar correlation was also developed using data from NASA's Chemical Equilibrium Applications (CEA) code to determine the equilibrium concentrations of carbon monoxide and nitrogen oxide as functions of overall equivalence ratio, water to fuel mass ratio, pressure and temperature (T3). The temperature of the gas entering the turbine (T4) was also correlated as a function of the initial combustor temperature (T3), equivalence ratio, water to fuel mass ratio, and pressure.

Molnar, Melissa↗

Influence of a Backward-Facing Step on Swept-Wing Boundary-Layer Transition

Experimental measurements were performed on a swept flat-plate model with an airfoil leading edge and imposed chordwise pressure gradient to determine the effects of a backward-facing step on transition in a low-speed stationary crossflow-dominated boundary layer. Detailed hot-wire measurements were performed for three step heights ranging from 36 to 49% of the boundary-layer thickness at the step and corresponding to subcritical, nearly critical, and critical cases. In general, the step had a small localized effect on the growth of the stationary crossflow vortex, whereas the unsteady disturbance amplitudes increased with increasing step height. Intermittent spikes in instantaneous velocity began to appear for the two larger step heights. A physical explanation was provided for the mechanism leading to transition and the sudden movement in the transition front due to the critical steps. The large localized velocity spikes, which ultimately led to an intermittent breakdown of the boundary layer, were the result of nonlinear interactions of the different types of unsteady instabilities with each other and with the stationary crossflow vortices. Thus, the unsteady disturbances played the most important role in transition, but the stationary crossflow vortices also had a significant role via the modulation and the increased amplitude of the unsteady disturbances.

Eppink, Jenna L.↗

Mechanisms of Stationary Crossflow Instability Growth and Breakdown Induced by Forward-Facing Steps

An experimental study is performed to determine the mechanisms by which a forward-facing step impacts the growth and breakdown to turbulence of the stationary cross-flow instability. Particle image velocimetry measurements are obtained in the boundary layer of a 30◦swept flat plate with a pressure body. Step heights range from 53 % to 71 % of the boundary-layer thickness. The critical step height is approximately 60 % of the boundary-layer thickness for the current study, although it is also shown that the critical step height depends on the initial amplitude of the stationary cross-flow vortices. For the critical cases, the stationary cross-flow amplitude grows sharply downstream of the step, decays for a short region and then grows again. The initial growth region is linear, and can be explained primarily through the impact of the step on the mean flow. Namely, the step causes abrupt changes to the mean flow, resulting in large values of wall-normal shear, as well as highly inflectional profiles, due to either cross-flow reversal, separation or both. These inflectional profiles are highly unstable for the stationary cross-flow. Additionally,the reversed flow regions are significantly modulated by the stationary cross-flow vortices. The second region of growth occurs due to the stationary-cross-flow-induced modulation of the shear layer, which leads to multiple smaller wavelength stream wise vortices. High-frequency fluctuations indicate that the unsteady transition mechanism for the critical cases relates to the shedding of vortices downstream of reattachment of the modulated separated regions.

boundary layer stability↗

XSP Methane Sensors Test and Evaluation Project “M-Step”

Methane sensor technology is employed in industry sectors from oil and gas to agriculture, landfills, and monitoring of natural emissions. The US oil and gas sector is extensive in scale, critical to fulfilling US energy needs, and deals with commodities presenting enormous challenges for personnel safety and the environment. Thus, it is imperative that they have accurate and responsive sensors to detect hazardous gases such as methane. US space launch systems will increasingly also use liquefied methane and liquefied natural gas (LNG), which is mostly methane, in quantities large and small, as main and auxiliary propulsion and power. Some of these systems will be reusable, which adds the unique challenge of processing a vehicle that has residual commodities and has returned to its launch site to be readied for its next launch. The methane sensors test and evaluation project (M-STEP) began within the context of a reusable launch system, the Defense Advanced Research Projects Agency (DARPA) Experimental Spaceplane (XSP) program, which would have employed a high-pressure gaseous methane and gaseous oxygen reaction control system. Although the XSP partnership between Boeing and DARPA was terminated by Boeing in early 2020, DARPA and KSC have continued to collaborate in the area of gas sensors with the hydrogen sensor test and evaluation project (H-STEP) and with M-STEP. The NASA Launch Services program (LSP) invested in M-STEP in FY 2021 “to evaluate and understand the state-of-the-art in methane gas sensors”. M-STEP and the LSP effort was complementary, pushing in the same direction to understand US launch system stakeholder needs and approaches, requirements internal (NASA) and external, and commercially available or forthcoming methane sensing technologies, practices, and approaches. In addition, M-STEP (as with H-STEP) enhances KSC capabilities and understanding of these technologies, informing agency investments and further research in these areas.

Tracy L. Gibson↗

LEAKAGE CHARACTERISTICS OF A STEPPED BALANCE PISTON LABYRINTH SEAL IN SUPERCRITICAL CO2

In an integrally geared compressor, there is a net thrust load on the pinion shaft from gear loads and aerodynamic forces. The net thrust on the pinion is resolved with either a thrust bearing or a thrust collar (rider ring). As the pressure increases, this increases the aerodynamic force proportionally. In highpressure systems this can overwhelm the thrust bearing or thrust collar if thrust is mismanaged. In a recent test program for an sCO2 integrally geared compander (compressor/turbine), a balance piston was created on the opposite end of the turbine to provide an equalizing thrust; while this is not novel, the balance piston provided a test apparatus for measuring the leakage on a 20 tooth stepped labyrinth seal operating at pressures in excess of 250 bar (3600 psi). The stepped balance piston seal is a 20 tooth tooth-onrotor balance piston seal. This type of seal was selected since it was predicted to have substantially less leakage than a comparably sized straight through labyrinth seal. Comparisons between the two designs will be made, showing that the leakage of the stepped balance piston seal is considerably lower. The tooth clearance on the seal was selected to be 30 mils radial. While this seems large, a stack-up tolerance assessment showed that this magnitude of clearance was appropriate to prevent rotor stator contact. During the testing campaign, data was recorded showing the leakage across this stepped balance piston seal at pressures in excess of 250 bar (3600 psi) with a pressure ratio of 2. This leakage data was measured, and will be compared to leakage data predicted with CFD. Two measurement methods are presented for the stepped balance piston seal: an orifice plate and valve. The predicted seal leakage from a straight through seal was four times that of the predicted stepped labyrinth seal. The measured flow from the stepped seal was on the same order as the CFD prediction and offered adequate rotordynamic performance

wilkes, jason↗

Short‐term time step convergence in a climate model

Abstract This paper evaluates the numerical convergence of very short (1 h) simulations carried out with a spectral‐element (SE) configuration of the Community Atmosphere Model version 5 (CAM5). While the horizontal grid spacing is fixed at approximately 110 km, the process‐coupling time step is varied between 1800 and 1 s to reveal the convergence rate with respect to the temporal resolution. Special attention is paid to the behavior of the parameterized subgrid‐scale physics. First, a dynamical core test with reduced dynamics time steps is presented. The results demonstrate that the experimental setup is able to correctly assess the convergence rate of the discrete solutions to the adiabatic equations of atmospheric motion. Second, results from full‐physics CAM5 simulations with reduced physics and dynamics time steps are discussed. It is shown that the convergence rate is 0.4—considerably slower than the expected rate of 1.0. Sensitivity experiments indicate that, among the various subgrid‐scale physical parameterizations, the stratiform cloud schemes are associated with the largest time‐stepping errors, and are the primary cause of slow time step convergence. While the details of our findings are model specific, the general test procedure is applicable to any atmospheric general circulation model. The need for more accurate numerical treatments of physical parameterizations, especially the representation of stratiform clouds, is likely common in many models. The suggested test technique can help quantify the time‐stepping errors and identify the related model sensitivities.

54 ENVIRONMENTAL SCIENCES↗

Models implemented in the methodological approach to design the initial STEP first wall contour

The official Spherical Tokamak for Energy Production mission aims to demonstrate the ability to generate net electricity from fusion with the STEP Prototype Power plant. One of the key technological and engineering challenges in fusion power plants is managing the loads on the first wall within acceptable limits. Therefore, the conceptual design development of the STEP Prototype Power plant needs to be based on load estimates derived using legitimate plasma physics assumptions through dynamic and flexible tools. The current design foresees the STEP main chamber first wall to withstand steady-state heat loads of up to ~1 MW/m 2 , excluding critical regions expected to receive higher heat loads such as the baffle regions approaching the divertors. These critical areas will require ad hoc assessments and will be designed with the presence of limiters. This article focuses on the models and methodology adopted for designing the 2-D poloidal contour of the STEP first wall, based on the anticipated charged particle and radiation heat loads during normal operation. Firstly, the models adopted for calculating the charged particle and radiation heat loads are introduced. The first model is validated through benchmarking against the particle tracing code SMARDDA, while the second model is verified by comparing it with data from the MAST-U experiment. Secondly, the model used to design the 2-D first wall contour according to the heat loads is explained. We acknowledge that this preliminary design stage assumes certain simplifications, notably an axisymmetric geometry, for computational efficiency and clarity in presentation. It is understood that subsequent design phases will address the complexities of real-world engineering, including non-axisymmetric effects, transient plasma scenarios, and the impact of disruptions on the first wall design. Finally, an automatic procedure based on these models is presented for defining the 2-D poloidal contour of the STEP first wall to minimize heat loads, taking into account the need to radiate most of the alpha-particle and auxiliary heating power. Here, by providing an overview of the models, methodology, and an automatic procedure, this paper contributes to the design process of the STEP first wall, addressing the engineering challenges associated with fusion power plant development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Storm Surge Modeling as an Application of Local Time-Stepping in MPAS-Ocean

This paper presents the first practical application of local time-stepping (LTS) schemes in the Model for Prediction Across Scales-Ocean (MPAS-O). We use LTS schemes in a single-layer, global ocean model that predicts the storm surge around the eastern coast of the United States during Hurricane Sandy. The variable-resolution meshes used are of unprecedentedly high resolution in MPAS-O, containing cells as small as 125 m wide in Delaware Bay. It is shown that a particular, third-order LTS scheme (LTS3) produces sea-surface height solutions that are of comparable quality to solutions produced by the classical four-stage, fourth-order Runge-Kutta method (RK4) with a uniform time step on the same meshes. Furthermore, LTS3 is up to 35% faster in the best cases considered, where the number of cells using the coarse time-step relative to those using the fine time-step is as low as 1:1. This shows that LTS schemes are viable for use in MPAS-O with the added benefit of substantially less computational cost. The results of these performance experiments inform us of the requirements for efficient mesh design and configuration of LTS regions for LTS schemes. In particular, we see that for LTS to be efficient on a given mesh, it is important to have enough cells using the coarse time-step relative to those using the fine time-step, typically at least 1:5 to see an increase in performance.

54 ENVIRONMENTAL SCIENCES↗

Fall Prevention in Community Settings: Results from Implementing Stepping On in Three States

Stepping On is a community-based intervention that has been shown in a randomized controlled trial to reduce fall risk. The Wisconsin Institute for Healthy Aging adapted Stepping On for use in the United States and developed a training infrastructure to enable dissemination. The purpose of this study is to: (1) describe the personal characteristics of Stepping On participants; (2) quantify participants’ functional and self-reported health status at enrollment, and (3) measure changes in participants’ functional and self-reported health status after completing the program. Both survey and observed functional status [timed up and go (TUG) test] data were collected between September 2011 and December 2013 for 366 participants enrolled in 32 Stepping On programs delivered in Colorado, New York, and Oregon. Paired t-tests and general estimating equations models adjusted for socio-demographic factors were performed to assess changes over the program period. Among the 266 participants with pre–post survey data, the average participant age was 78.7 (SD ± 8.0) years. Most participants were female (83.4%), white (96.9%), and in good health (49.4%). The TUG test scores decreased significantly (p < 0.001) for all 254 participants with pre–post data. The change was most noticeable among high risk participants where TUG time decreased from 17.6 to 14.4 s. The adjusted odds ratio of feeling confident about keeping from falling was more than three times greater after completing Stepping On. Further, the adjusted odds ratios of reporting “no difficulty” for getting out of a straight back chair increased by 89%. Intended for older adults who have fallen in the past or are afraid of falling, Stepping On has the potential to reduce the frequency and burden of older adult falls.

59 BASIC BIOLOGICAL SCIENCES↗