Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Status”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

DUNE Physics Program and Status

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino experiment with a 70-kt liquid argon detector at the Sanford Underground Research Facility (SURF) 1300 km from Fermilab. This programme includes studies of neutrino oscillations with a high-intensity muon-neutrino beam from Fermilab; as well as, proton decay and supernova neutrino burst searches. DUNE will resolve the neutrino mass hierarchy to a precision of 5σ, for all δ$_{CP}$ values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3σ (5σ) after an exposure of 5 (10) years, for 50% of all δ$_{CP}$ values. The status and schedule of the project is also presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of LBNF/DUNE near site liquid argon proximity and external cryogenics systems development.

The Deep Underground Neutrino Experiment (DUNE) near site located at Fermilab will host the neutrino beam complex. It includes a high voltage liquid argon time projection chamber located 60-meter underground used as beamline instrumentation. The LAr cryogenic system provided by the Long-Baseline Neutrino Facility (LBNF) regulates thermohydraulic conditions of the membrane cryostat hosting the detector with 285 Ton purified LAr. The purification system uses molecular sieve and copper oxide pellets to manage the argon contamination below 100 ppt (parts per trillion) oxygen equivalent. The detector and its cryogenics are capable to move a stroke of 30 meters on/off beam. The cryogenic system modes of operation include the cryostat pressure test, purge in open loop, detector cooldown, cryostat fill, closed loop purification, liquid empty, and purification system activation/regeneration process. The system design status and schedule, and technical details such as operating modes and interfaces are reported in this paper.

43 PARTICLE ACCELERATORS↗

Overview and status of the Long-Baseline Neutrino Facility Far Site cryogenics system

The Sanford Underground Research Facility (SURF) will host the Far Detector of the Deep Underground Neutrino Experiment (DUNE), an international multi-kiloton Long-Baseline neutrino experiment that will be installed about one and a half kilometers underground in Lead, SD. Detectors will be located inside four cryostats filled with almost 70,000 metric tons of ultrapure liquid argon, with a level of impurities lower than 100 parts per trillion of oxygen equivalent contamination. The cryogenics infrastructure supporting this experiment is provided by the Long-Baseline Neutrino Facility (LBNF). This contribution presents modes of operation, layout, and main features of the LBNF Far Site cryogenic system, which is composed of three subsystems: Infrastructure, Proximity, and Internal cryogenics. The Infrastructure cryogenics supports the needs of the cryostat and Proximity cryogenics. It includes the equipment to receive the argon in liquid phase, vaporize it and transfer it underground as a gas, the nitrogen system (composed of the refrigeration system, liquid nitrogen buffer tanks and liquid and gaseous nitrogen distribution), liquid and gaseous argon distribution and process controls. The Proximity cryogenics receives fluids from the Infrastructure cryogenics and delivers them to the Internal cryogenics at the required temperature, pressure, purity and mass flow rate. It includes the argon condensers, liquid and gaseous argon purification and regeneration systems, nitrogen and argon phase separators, piping, valves, and instrumentation. The Internal cryogenics comprises the liquid and gaseous argon distribution inside the cryostats for the commissioning, cool down, fill, and steady state operations of the cryostats and detectors. An international engineering team is designing these systems and will manufacture, install, commission, and qualify them. This contribution describes the main features, performance, functional requirements, and modes of operation of the LBNF Far Site cryogenics system. It also presents the status of the design, along with present and future needs to support the DUNE experiment.

43 PARTICLE ACCELERATORS↗

Direct-drive laser fusion: status, plans and future

Laser-direct drive (LDD), along with laser indirect (X-ray) drive (LID) and magnetic drive with pulsed power, is one of the three viable inertial confinement fusion approaches to achieving fusion ignition and gain in the laboratory. The LDD programme is primarily being executed at both the Omega Laser Facility at the Laboratory for Laser Energetics and at the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory. LDD research at Omega includes cryogenic implosions, fundamental physics including material properties, hydrodynamics and laser–plasma interaction physics. LDD research on the NIF is focused on energy coupling and laser–plasma interactions physics at ignition-scale plasmas. Limited implosions on the NIF in the ‘polar-drive’ configuration, where the irradiation geometry is configured for LID, are also a feature of LDD research. The ability to conduct research over a large range of energy, power and scale size using both Omega and the NIF is a major positive aspect of LDD research that reduces the risk in scaling from OMEGA to megajoule-class lasers. Furthermore, the paper will summarize the present status of LDD research and plans for the future with the goal of ultimately achieving a burning plasma in the laboratory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lessons Learned From the Prototypes of the MQXFA Low-Beta Quadrupoles for HL-LHC and Status of Production in the US

With the successful test of the first two pre-series magnets the US HL-LHC Accelerator Upgrade Project has started production of the MQXFA magnets to be used in Q1/Q3 inner triplet elements of the HL-LHC. This good start comes after the test of two prototypes with limited performance, and it demonstrates the importance of learning from past issues. Therefore, in this paper we want to share the most important lessons learned so far, focusing on those which may be more interesting for similar projects. Additionally, we will present the status of MQXFA fabrication in the US.

43 PARTICLE ACCELERATORS↗

Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are building a new High Field Vertical Magnet Test Facility (HFVMTF) for testing superconducting cables in high magnetic field. The background magnetic field of 15 T in the HFVMTF will be produced by a magnet provided by LBNL. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics (HEP), and Fusion Energy Sciences (FES), and will serve as a superconducting cable test facility in high magnetic fields and a wide range of temperatures for HEP and FES communities. This facility will also be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program (MDP). The paper describes the status of the facility, including construction, cryostat designs, top and lambda plates, and systems for powering, and quench protection and monitoring.

43 PARTICLE ACCELERATORS↗

Status of the Top Plate and Anticryostat for High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (Fermilab) is currently constructing a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing High Temperature Superconducting (HTS) cables under high magnetic fields. This facility is expected to offer capabilities similar to those of EDIPO at PSI and FRESCA2 at CERN. The background magnetic field of 15 T will be generated by a magnet supplied by Lawrence Berkeley National Laboratory. The primary function of HFVMTF will be to serve as a superconducting cable test facility, facilitating tests under high magnetic fields and a broad spectrum of cryogenic temperatures. Additionally, the facility will be utilized for testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Program (MDP). This paper provides a comprehensive description of the current status of two pivotal components of the facility: the Top/Lambda Plates Assembly and the Anticryostat for the Test Sample Holder. The latter will serve as a principal interface component connecting cable test samples with the facility's cryostat.

43 PARTICLE ACCELERATORS↗

Status and Challenges in the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

The inner triplet (or low-β) quadrupole magnets are among the components to be upgraded in LHC interaction regions for the HL-LHC project. The new quadrupole magnets, called MQXF, are based on Nb 3 Sn superconducting magnet technology, with a conductor peak field of 11.3 T. CERN is in charge of the fabrication of the MQXFB variant, the longest Nb 3 Sn accelerator magnets designed and manufactured up to now, with a magnetic length of 7.2 m. Two magnets, MQXFBP3 and MQXFB02, reached the HL-LHC project requirements. However, they still exhibited a limitation at 4.5 K with a phenomenology similar to the one observed on the first two prototypes. After improvements on the cold mass (longitudinal welding) and magnet assembly (elimination of overstress on the conductor during loading) procedures, a series of modifications were implemented in MQXFB03 at the level of the coil fabrication to address and/or reduce weaknesses in the coils. The magnet was tested and was the first to achieve performance requirements at both 1.9 K and 4.5 K, with no signs of conductor limitation at 4.5 K. MQXFB is now in the series production phase, with around 2/3 of the coils completed and half of the magnets assembled. We provide in this paper an overview of the MQXFB program, with a summary of the main recent achievements and an overall status of the fabrication.

43 PARTICLE ACCELERATORS↗

The Materials Plasma Exposure eXperiment: Status of the Physics Basis Together With the Conceptual Design and Plans Forward

The Materials Plasma Exposure eXperiment (MPEX) is a linear plasma device that will address the plasma–material interaction (PMI) science for future fusion reactors and will enable testing of plasma-facing components (PFCs). It is designed as a steady-state device eventually delivering an ion fluence of up to 10 31 m -2 to the target. The device will be designed to handle neutron-activated materials. These capabilities should push the technical readiness level of PFCs up to six for some end-of-life aspects. In order to achieve the relevant plasma conditions, as they are expected in future fusion reactor divertors, MPEX will utilize a novel plasma source concept. This plasma source concept uses a high-power helicon (200 kW, 13.56 MHz), an electron cyclotron heating (ECH) system, which will heat electrons via electron Bernstein wave (EBW) heating (about 400 kW, 70 GHz), and an ion cyclotron heating (ICH) system (400 kW, 6–9 MHz). The physics basis for this plasma source concept including the heating physics and transport is based on experiments on Proto-MPEX. An overview of the experimental results and the physics basis will be given. The physics basis directly translates into functional requirements of MPEX and the conceptual design. The status of the conceptual design of MPEX will be shown.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current status and future outlook for patient‐derived cancer models from a rare cancer research perspective

Abstract Rare cancers are a group of approximately 200 malignancies with extremely low incidences and with a wide variety of genotypes and phenotypes. Collectively, they are more common than any single malignancy. However, given the small numbers of individuals diagnosed with rare cancers, it is difficult to design clinical trials with sufficient patient numbers. Therefore, few effective anticancer drugs have been developed, and evidence‐based medicine is not always feasible for rare cancers. Consequently, their clinical outcomes are generally poorer. Cancer research requires adequate models that faithfully recapitulate molecular features and reproduce treatment responses of the original tumors. Such models allow us to focus on more efficacious drugs in the clinical studies. For rare cancers, patient‐derived cancer models are particularly important because the enrollment of sufficient patients is rarely attainable within a reasonable period of time. However, extremely few models are available for rare cancers. For example, cell lines and xenografts are available for only a limited number of histological subtypes of sarcomas; therefore, most sarcoma research is performed without such models, and a lack of adequate cancer models causes a lag in therapeutic development. The establishment of novel rare cancer models will dramatically facilitate rare cancer research and treatment development in the near future. This review focuses on the status of patient‐derived rare cancer models and discusses their pivotal problems and possibilities, using sarcomas as a representative rare cancer type. Multi‐institutional collaboration will help address the scarcity of patient‐derived rare cancer models.

Kondo, Tadashi↗

Allopregnanolone as an Adjunct Therapy to Midazolam is More Effective Than Midazolam Alone in Suppressing Soman‐Induced Status Epilepticus in Male Rats

ABSTRACT Aims Humans and animals acutely intoxicated with the organophosphate soman can develop sustained status epilepticus (SE) that rapidly becomes refractory to benzodiazepines. We compared the antiseizure efficacy of midazolam, a current standard of care treatment for OP‐induced SE, versus combined therapy with midazolam and allopregnanolone (ALLO) in a rat model of soman‐induced SE. Methods Soman‐intoxicated male rats with robust seizure behavior and high‐amplitude electroencephalographic (EEG) activity were administered midazolam (0.65 mg, i.m.) 20 min after seizure initiation and 10 min later either a second dose of midazolam or ALLO (12 or 24 mg/kg, i.m.). Seizure behavior and EEG were monitored for 4 h after treatment. Brains were collected at the end of the monitoring period for histological analyses. Results Animals receiving 2 doses of midazolam exhibited persistent SE. Sequential dosing with midazolam followed by ALLO suppressed electrographic seizure activity. The combination therapy also significantly reduced soman‐induced neurodegeneration and neuroinflammation compared to 2 doses of midazolam. High but not low dose ALLO was associated with transitory and reversible respiratory compromise during the 1 h period after dosing. Conclusions Treatment with midazolam followed by ALLO was more effective than 2 doses of midazolam in suppressing benzodiazepine‐refractory, soman‐induced SE, and in mitigating its acute neuropathological consequences.

Andrew, Peter M. [Department of Molecular Bioscien↗

Plastoquinone redox status influences carboxysome integrity via a RpaA ‐ and reactive oxygen species‐dependent regulatory network

SUMMARY Carboxysomes are bacterial microcompartments that encapsulate Rubisco and are a core component of the cyanobacterial carbon concentration mechanism (CCM). While carboxysome number, size, and spatial organization vary in different environmental conditions (CO 2 , light availability, redox state, temperature, and light quality), the molecular mechanisms underlying this potentially adaptive process remain elusive. Herein, we observe that mutants of the circadian rhythm/metabolism factor, Regulator of Phycobilisome Association A (RpaA), exhibit a striking breakdown of carboxysomes under certain environmental conditions. We find that conditions leading to overreduction of the plastoquinone (PQ) pool (mixotrophic growth, high irradiance, or chemical inhibition of electron transfer from PQ to the cytochromeb 6 fcomplex) are accompanied by an elevated generation of reactive oxygen species (ROS) and correlate with the loss of carboxysome integrity. Carboxysome breakdown is reversed by environmental conditions or chemical inhibitors that prevent PQ overreduction and accompanying ROS generation. Taken together, our data support a novel link between the redox status of the PQ pool and carboxysome integrity. Our results have implications for the fundamental understanding of cyanobacterial energy‐balancing pathways and may indicate new research directions for understanding how the carboxysome is remodeled in response to changing environments.

Plant Sciences↗

Status of Lattice QCD Determination of Nucleon Form Factors and Their Relevance for the Few-GeV Neutrino Program

Calculations of neutrino–nucleus cross sections begin with the neutrino–nucleon interaction, making the latter critically important to flagship neutrino oscillation experiments despite limited measurements with poor statistics. Alternatively, lattice quantum chromodynamics (LQCD) can be used to determine these interactions from the Standard Model with quantifiable theoretical uncertainties. Recent LQCD results of g A are in excellent agreement with data, and results for the (quasi-)elastic nucleon form factors with full uncertainty budgets are expected within a few years. We review the status of the field and LQCD results for the nucleon axial form factor, F A ( Q 2 ), a major source of uncertainty in modeling sub-GeV neutrino–nucleon interactions. Results from different LQCD calculations are consistent but collectively disagree with existing models, with potential implications for current and future neutrino oscillation experiments. We describe a road map to solidify confidence in the LQCD results and discuss future calculations of more complicated processes, which are important to few-GeV neutrino oscillation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inertial Confinement Fusion: Status and Challenges

While a variety of laboratory-based fusion schemes have been studied for decades, the only fusion scheme yet to demonstrate fusion ignition and significant energy gain has been X-ray-driven inertially confined fusion. Ignition was demonstrated to occur at the thermodynamic conditions where it had long been expected, but the energy required for the implosion system to reach these conditions was more than projected years ago. This short review gives a status update on the three principal inertial confinement fusion schemes and research challenges going forward.

gain↗

Assured Timing Detector - Status Display

The Assured Timing Detector Status Display allows for Web browser hosted monitoring of system health and annunciation of timing anomaly alerts reported by the companion Assured Timing Detector software.

Beauchamp, BrockR↗

Predicting Postoperative Injury and Military Discharge Status After Knee Surgery in the US Army

Background: Researchers have assessed postoperative injury or disability predictors in the military setting but typically focused on 1 type of surgical procedure at a time, used relatively small sample sizes, or investigated mixed cohorts with civilian populations. Purpose: To identify the relationship between baseline variables and injury incidence or military discharge status in US Army soldiers after knee surgery. Study Design: Case-control study; Level of evidence, 3. Methods: Data were obtained from a repository containing personnel, performance, and medical records for all active-duty US Army soldiers. Multivariate logistic regressions were used to estimate the effects of numerous variables on postoperative injury or on medical discharge. Variable selection and model validation were conducted using the k-fold method. Results: A total of 7567 soldiers underwent knee surgery between 2017 and 2019. Meniscal procedures were the most common type of surgery (39%), and approximately 71% of the cohort had a postoperative injury. Significant predictors for sustaining a postoperative injury included having a previous nonknee injury (odds ratio [OR], 1.5), female sex (OR, 1.3), and Black race (OR, 1.2). Within 4 years after surgery, 17% of soldiers were discharged from the military because of knee-related disability. Significant predictors for discharge from duty included enlisted rank (OR, 2.3), recent fitness test failure (OR, 1.9), number of previous knee surgeries (OR, 1.7), and having a previous nonknee injury (OR, 1.6). Conclusion: After knee surgery, nearly three-fourths of the soldiers in this cohort sustained a postoperative injury and almost one-fifth of soldiers were medically discharged from the military within 4 years. This study identified variables that indicate statistically increased risk for these postoperative outcomes and highlighted potentially modifiable factors.

Orthopedics↗

The legacy of weapons grade plutonium production: Health status of Hanford complex workers who manage the waste

The extent and etiology of health effects in workers who maintain underground storage tanks at the Hanford Nuclear Reservation (Hanford) have been subjects of controversy and concern for several decades. Hanford is a decommissioned nuclear production complex managed by the US Department of Energy in southeast Washington State. This integration-of-evidence review evaluates the relationship between exposure to vapors from mixed chemical and radioactive waste stored in underground storage tanks at Hanford and worker health. Hanford workers’ health information was gathered from technical reports, media reports, and published literature, including the systematic search of seven databases. This review describes the health status and health concerns of Hanford tank farm workers based on the integration of the available health effects data from disparate sources. In interviews with external groups, Hanford workers reported both irritant-type symptoms and diseases that they believe are attributable to tank farm vapors. However, the results of this integration-of-evidence review indicated that no pervasive pattern of occupational disease was identified that can be associated with exposure to tank farm vapors. Inhalation exposure to asbestos and beryllium is associated with lung disease from various types of nuclear industry work but not from work on tank farms. This review concluded that while irritant-type symptoms and isolated cases of occupational disease are plausible under certain conditions, the currently available data do not support a pervasive pattern of occupational disease associated with vapor exposure.

Cherry, Debra↗