Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Seeing through noise in power laws

Despite widespread claims of power laws across the natural and social sciences, evidence in data is often equivocal. Modern data and statistical methods reject even classic power laws such as Pareto’s law of wealth and the Gutenberg–Richter law for earthquake magnitudes. We show that the maximum-likelihood estimators and Kolmogorov–Smirnov (K-S) statistics in widespread use are unexpectedly sensitive to ubiquitous errors in data such as measurement noise, quantization noise, heaping and censorship of small values. This sensitivity causes spurious rejection of power laws and biases parameter estimates even in arbitrarily large samples, which explains inconsistencies between theory and data. We show that logarithmic binning by powers of λ > 1 attenuates these errors in a manner analogous to noise averaging in normal statistics and that λ thereby tunes a trade-off between accuracy and precision in estimation. Binning also removes potentially misleading within-scale information while preserving information about the shape of a distribution over powers of λ, and we show that some amount of binning can improve sensitivity and specificity of K-S tests without any cost, while more extreme binning tunes a trade-off between sensitivity and specificity. We therefore advocate logarithmic binning as a simple essential step in power-law inference.

97 MATHEMATICS AND COMPUTING↗

Probabilistic-learning-based stochastic surrogate model from small incomplete datasets for nonlinear dynamical systems

We consider a high-dimensional nonlinear computational model of a dynamical system, parameterized by a vector-valued control parameter, in the presence of uncertainties represented by an uncontrolled parameter modeled by a vector-valued random variable, and possibly with stochastic excitation. The objective is to construct a statistical surrogate model where the input is any deterministic value of the control parameter, and the output is a vector-valued observation of the computational model, which is a random vector whose probability measure is updated using a target dataset. To construct this statistical surrogate model, the stochastic response of the computational model must be built, which is a vector-valued time-discretized stochastic process in high dimension, depending on the control parameter. It is assumed that the computational cost of a single evaluation of the deterministic model is high. For the probabilistic updating, we consider a subset of the components of the observation of the computational model, defined as the “identification observation” of the computational model, for which a small target dataset is available. Therefore, the target dataset is associated with partial observability, corresponding to an incomplete data case. Given a prior probability model of the random control and uncontrolled parameters, a training dataset is constructed, consisting of realizations of the random triplet composed of the stochastic response, the random identification observation, and the random control parameter. Since the computational cost of a single evaluation of the deterministic model is assumed to be large, the training dataset is also of small size. The main challenges in this problem are the high dimensionality, partial observability leading to incomplete data in the target dataset for the identification observation of the computational model (which is not sufficient to identify the computational stochastic responses), and the availability of a small training dataset. To address these challenges, we propose a methodology based on statistical methods for constructing necessary reduced representations, direct probabilistic learning under constraints using probabilistic learning on manifolds (PLoM) constrained by the target dataset, and the use of a weak formulation of the Fourier transform of probability measures. Statistical conditioning is also employed to explore the learned dataset. The constructed predictive statistical surrogate model can be implemented in the context of online computation. Here, we apply this approach to a problem of nonlinear stochastic dynamics in high dimensions within the framework of deformable solids mechanics.

Engineering↗

Deciphering the source of primary biological aerosol particles: a pollen case study

Primary biological aerosol particles (PBAPs) are microscopic solids suspended in the atmosphere emitted by biological systems and play critical roles in the atmosphere and at the atmosphere-biosphere interface, impacting human health, climate, and the ecosystem function. Understanding the sources of PBAPs is necessary to decipher the mechanistic interactions between aerosols, climate, and distinct ecosystem components. However, the detection of specific PBAPs in complex ambient aerosol samples is challenging. We performed metabolomics analyses of pollen from three pollinating tree species and ambient samples collected during the peak pollination period of each species. Random Forest and sPLS-DA machine learning methods were employed to evaluate whether metabolic signatures of ambient samples can reveal the source of the main pollen particles present in the atmosphere. Our results suggest that atmospheric eco-metabolomics techniques combined with sophisticated statistical methods can decipher the origin of abundant PBAPs from complex ambient samples. Developing complete libraries containing high-resolution metabolomic fingerprints of the major PBAPs present in the atmosphere would significantly advance future research to accurately understand the role of PBAPs in the atmosphere, ecosystems and human health.

Rivas-Ubach, Albert↗

Phase Space Dissimilarity Measures for Structural Health Monitoring

A novel method for structural health monitoring (SHM), known as the Phase Space Dissimilarity Measures (PSDM) approach, is proposed and developed. The patented PSDM approach has already been developed and demonstrated for a variety of equipment and biomedical applications. Here, we investigate SHM of bridges via analysis of time serial accelerometer measurements. This work has four aspects. The first is algorithm scalability, which was found to scale linearly from one processing core to four cores. Second, the same data are analyzed to determine how the use of the PSDM approach affects sensor placement. We found that a relatively low-density placement sufficiently captures the dynamics of the structure. Third, the same data are analyzed by unique combinations of accelerometer axes (vertical, longitudinal, and lateral with respect to the bridge) to determine how the choice of axes affects the analysis. The vertical axis is found to provide satisfactory SHM data. Fourth, statistical methods were investigated to validate the PSDM approach for this application, yielding statistically significant results.

47 OTHER INSTRUMENTATION↗

Innovative Coal Solids-Flow Monitoring and Measurement Using Phase-Doppler and Mie Scattering Techniques

Fuel flow to individual burners is complicated and difficult to determine on coal fired boilers, since coal solids were transported in a gas suspension that is governed by the complex physics of two-phase flow. The objectives of the project were the measurements of suspended coal solids-flows in the simulated test conditions. Various extractive methods were performed manually and can give only a snapshot result of fuel distribution. In order to measure particle diameter & velocity, laser based phase-Doppler particle analyzer (PDPA) and particle image velocimetry (PIV) were carefully applied. Statistical methods were used to analyze particle characteristics to see which factors have significant effect. The transparent duct model was carefully designed and fabricated for the laser-based-instrumentation of solids-flow monitoring (LISM). The experiments were conducted with two different kinds of particles with four different particle diameters. The particle types were organic particles and saw dust particles with the diameter range of 75-150 micron, 150-250 micron, 250-355 micron and 355-425 micron. The densities of the particles were measured to see how the densities affected the test results. Also the experiment was conducted with humid particles and fog particles. To generate humid particles, the humidifier was used. A pipe was connected to the humidifier to lead the particle flow to the intersection of the laser beam. The test results of the particle diameter indicated that, the mean diameter of humid particles was between 6.1703 microns and 6.6947 microns when the humid particle flow was low. When the humid particle flow was high, the mean diameter was between 6.6728 microns and 7.1872 microns. The test results of the particle mean velocity indicated that the mean velocity was between 1.3394 m/sec and 1.4556 m/sec at low humid particle flow. When the humid particle flow was high, the mean velocity was between 1.5694 m/sec and 1.7856 m/sec. The Air Flow Module, TQ AF 17 and shell ondina oil were used to generate fog particles. After the oil was heated inside the fog generator, the blower was used to generate the fog. The fog flew along the pipe to the intersection of the laser beam. The mean diameter of the fog particles was 5.765 microns. Compared with the humid particle diameter, we observed that the mean diameter of the fog particles was smaller than the humid particles. The test results of particle mean velocity was about 3.76 m/sec. Compared with the mean velocity of the humid particles, we can observed the mean velocity of fog particles were greater than humid particles. The experiments were conducted with four different kinds of particles with five different particle diameters. The particle types were organic particles, coal particles, potato particles and wheat particles with the diameter range of 63-75 micron, less than 150 micron, 150-250 micron, 250-355 micron and 355-425 micron. To control the flow rate, the control gate of the particle dispensing hopper was adjusted to 1/16 open rate, 1/8 open rate and 1/4 open rate. The captured image range was 0 cm to 5 cm from the control gate, 5 cm to 10 cm from the control gate and 10 cm to 15 cm from the control gate. Some of these experiments were conducted under both open environment conditions and closed environment conditions. Thus these experiments had a total of five parameters which were type of particles, diameter of particles, flow rate, observation range, and environment conditions. The coal particles (diameter between 63 and 75 microns) tested under the closed environment condition had three factors that were considered as the affecting factors. They were open rate, observation range, and environment conditions. In this experiment, the interaction of open rate and observation range had a significant effect on the lower limit. On the upper limit, the open rate and environment conditions had a significant effect. In addition, the interaction of open rate and environment conditions had a significant effect. The coal particles tested (diameter between 63 and 75 microns) under open environment, two factors were that considered as the affecting factors. They were the open rate and observation ranges. In this experiment, there was no significant effect on the lower limit. On the upper limit, the observation range had a significant effect. In addition, the interaction of open rate and observation range had a significant effect for the source of variation with 95% of confidence based on analysis of variance (ANOVA) results.

01 COAL, LIGNITE, AND PEAT↗

Discussion: the design and analysis of the Gaussian process model

The investigation of complex physical systems utilizing sophisticated computer models has become commonplace with the advent of modern computational facilities. In many applications, experimental data on the physical systems of interest is extremely expensive to obtain and hence is available in limited quantities. The mathematical systems implemented by the computer models often include parameters having uncertain values. This article provides an overview of statistical methodology for calibrating uncertain parameters to experimental data. This approach assumes that prior knowledge about such parameters is represented as a probability distribution, and the experimental data is used to refine our knowledge about these parameters, expressed as a posterior distribution. Uncertainty quantification for computer model predictions of the physical system are based fundamentally on this posterior distribution. Computer models are generally not perfect representations of reality for a variety of reasons, such as inadequacies in the physical modeling of some processes in the dynamic system. The statistical model includes components that identify and adjust for such discrepancies. A standard approach to statistical modeling of computer model output for unsampled inputs is introduced for the common situation where limited computer model runs are available. Extensions of the statistical methods to functional outputs are available and discussed briefly.

97 MATHEMATICS AND COMPUTING↗

A three-dimensional statistical approach to improved image quality for multislice helical CT

Multislice helical computed tomography scanning offers the advantages of faster acquisition and wide organ coverage for routine clinical diagnostic purposes. However, image reconstruction is faced with the challenges of three-dimensional cone-beam geometry, data completeness issues, and low dosage. Of all available reconstruction methods, statistical iterative reconstruction (IR) techniques appear particularly promising since they provide the flexibility of accurate physical noise modeling and geometric system description. In this paper, we present the application of Bayesian iterative algorithms to real 3D multislice helical data to demonstrate significant image quality improvement over conventional techniques. We also introduce a novel prior distribution designed to provide flexibility in its parameters to fine-tune image quality. Specifically, enhanced image resolution and lower noise have been achieved, concurrently with the reduction of helical cone-beam artifacts, as demonstrated by phantom studies. Clinical results also illustrate the capabilities of the algorithm on real patient data. Although computational load remains a significant challenge for practical development, superior image quality combined with advancements in computing technology make IR techniques a legitimate candidate for future clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Periodic Verification of the Scaling Factor for Radwastes in Korean NPPs - 13294

According to the acceptance criteria for a low and intermediate level radioactive waste (LILW) listed in Notice No. 2012-53 of the Nuclear Safety and Security Commission (NSSC), specific concentrations of radionuclides inside a drum has to be identified and quantified. In 5 years of effort, scaling factors were derived through destructive radiochemical analysis, and the dry active waste, spent resin, concentration bottom, spent filter, and sludge drums generated during 2004 ∼ 2008 were evaluated to identify radionuclide inventories. Eventually, only dry active waste among LILWs generated from Korean NPPs were first shipped to a permanent disposal facility on December 2010. For the LILWs generated after 2009, the radionuclides are being radiochemically quantified because the Notice clarifies that the certifications of the scaling factors should be verified biennially. During the operation of NPP, the radionuclides designated in the Notice are formed by neutron activation of primary coolant, reactor structural materials, corrosion products, and fission products released into primary coolant through defects or failures in fuel cladding. Eventually, since the radionuclides released into primary coolant are transported into the numerous auxiliary and support systems connected to primary system, the LILWs can be contaminated, and the radionuclides can have various concentration distributions. Thus, radioactive wastes, such as spent resin and dry active waste generated at various Korean NPP sites, were sampled at each site, and the activities of the regulated radionuclides present in the sample were determined using radiochemical methods. The scaling factors were driven on the basis of the activity ratios between a or β-emitting nuclides and γ-emitting nuclides. The resulting concentrations were directly compared with the established scaling factors' data using statistical methods. In conclusions, the established scaling factors were verified with a reliability of within 2σ, and the scaling factors will be applied for newly analyzed LILWs to evaluate the radionuclide inventories. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

THERMAL ANALYSIS OF 3013/9975 CONFIGURATION

The 3013 containers are designed in accordance with the DOE-STD-3013-2004 and are qualified to store plutonium (Pu) bearing materials for 50 years. The U.S. Department of Energy (DOE) certified Model 9975 shipping package is used to transport the 3013 containers to the K-Area Material Storage (KAMS) facility at the Savannah River Site (SRS) and to store the containers until the plutonium can be properly dispositioned. Detailed thermal analyses to support the storage in the KAMS facility are given in References 2, 3, and 4. The analyses in this paper serve to provide non-accident condition, non-bounding, specific 3013 container temperatures for use in the surveillance activities. This paper presents a methodology where critical component temperatures are estimated using numerical methods over a range of package and storage parameters. The analyses include factors such as ambient storage temperature and the content weight, density, heat generation rate, and fill height, that may impact the thermal response of the packages. Statistical methods are used to develop algebraic equations for ease of computations to cover the factor space. All computations were performed in BTU-FT-Hr-{sup o}F units.

42 ENGINEERING↗

Stereotactic Body Radiation Therapy and the Influence of Chemotherapy on Overall Survival for Large (≥5 Centimeter) Non-Small Cell Lung Cancer

Purpose: Stereotactic body radiation therapy (SBRT) for ≥5 cm lesions is poorly defined, largely owing to the low sample sizes in existing studies. The present analysis examined the SBRT outcomes and assessed the effect of chemotherapy in this population. Methods and Materials: The National Cancer Data Base was queried for primary non-small cell lung cancer ≥5 cm treated with SBRT (≤10 fractions). Patient, tumor, and treatment parameters were extracted. The primary outcome was overall survival (OS). Statistical methods involved Kaplan-Meier analysis and multivariable Cox proportional hazards modeling. Results: From 2004 to 2012, data from 201 patients were analyzed. The median follow-up was 41.1 months. The median tumor size was 5.5 cm (interquartile range 5.0-6.0), with cT2a, cT2b, and cT3 disease in 24.9%, 53.2%, and 21.9%, respectively. The median total SBRT dose and fractionation was 50 Gy in 4 fractions, and 92.5% of the patients underwent SBRT with ≤5 fractions. The median OS was 25.1 months. Of the 201 patients, 15% received chemotherapy. The receipt of chemotherapy was associated with longer OS (median 30.6 vs 23.4 months; P=.027). On multivariable analysis, worse OS was seen with increasing age (hazard ratio [HR] 1.03; P=.012), poorly differentiated tumors (HR 2.06; P=.049), and T3 classification (HR 2.13; P=.005). On multivariable analysis, chemotherapy remained independently associated with improved OS (HR 0.57; P=.039). Conclusions: SBRT has utility in the setting of tumors ≥5 cm, with chemotherapy associated with improved OS in this subset. These hypothesis-generating data now raise the necessity of performing prospective analyses to determine whether chemotherapy confers outcome benefits after SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodel Predictive System for Carbon Dioxide Solubility in Saline Formation Waters

The prediction of carbon dioxide solubility in brine at conditions relevant to carbon sequestration (i.e., high temperature, pressure, and salt concentration (T-P-X)) is crucial when this technology is applied. Eleven mathematical models for predicting CO{sub 2} solubility in brine are compared and considered for inclusion in a multimodel predictive system. Model goodness of fit is evaluated over the temperature range 304–433 K, pressure range 74–500 bar, and salt concentration range 0–7 m (NaCl equivalent), using 173 published CO{sub 2} solubility measurements, particularly selected for those conditions. The performance of each model is assessed using various statistical methods, including the Akaike Information Criterion (AIC) and the Bayesian Information Criterion (BIC). Different models emerge as best fits for different subranges of the input conditions. A classification tree is generated using machine learning methods to predict the best-performing model under different T-P-X subranges, allowing development of a multimodel predictive system (MMoPS) that selects and applies the model expected to yield the most accurate CO{sub 2} solubility prediction. Statistical analysis of the MMoPS predictions, including a stratified 5-fold cross validation, shows that MMoPS outperforms each individual model and increases the overall accuracy of CO{sub 2} solubility prediction across the range of T-P-X conditions likely to be encountered in carbon sequestration applications.

54 ENVIRONMENTAL SCIENCES↗

Grid-based minimization at scale: Feldman-Cousins corrections for light sterile neutrino search

High Energy Physics (HEP) experiments generally employ sophisticated statistical methods to present results in searches of new physics. In the problem of searching for sterile neutrinos, likelihood ratio tests are applied to short-baseline neutrino oscillation experiments to construct confidence intervals for the parameters of interest. The test statistics of the form Δχ2 is often used to form the confidence intervals, however, this approach can lead to statistical inaccuracies due to the small signal rate in the region-of-interest. In this paper, we present a computational model for the computationally expensive Feldman-Cousins corrections to construct a statistically accurate confidence interval for neutrino oscillation analysis. The program performs a grid-based minimization over oscillation parameters and is written in C++. Our algorithms make use of vectorization through Eigen3, yielding a single-core speed-up of 350 compared to the original implementation, and achieve MPI data parallelism by employing DIY. We demonstrate the strong scaling of the application at High-Performance Computing (HPC) sites. We utilize HDF5 along with HighFive to write the results of the calculation to file.

Wospakrik, Marianette↗

Creating a Face from a DNA Sample

The idea of creating a recognizable face from a sample of DNA is moving closer to reality as Oak Ridge National Laboratory (ORNL) researchers employ a novel statistical representation of the face and a genome-wide association study (GWAS) to relate facial characteristics to genetic mutations. The reduction in cost of DNA sequencing and genotyping technology is leading to the availability of massive datasets of human genome sequences and human genotypes representing mutational variation among people. These large-scale data provide for the first time the potential to correlate an individual’s specific genetic code with their physical appearance. Using a specialized statistical method for representing the entire 3D shape of faces, ORNL researchers performed a GWAS to discover associations between genetic mutations and aspects of face shape. Data from 3,556 subjects resulted in the discovery of a very large set of statistically significant associations, which is strong evidence for the viability of predicting faces from DNA.

59 BASIC BIOLOGICAL SCIENCES↗

Active galactic nucleus X-ray variability in the XMM-COSMOS survey

We used the observations carried out by XMM in the COSMOS field over 3.5 yr to study the long term variability of a large sample of active galactic nuclei (AGNs) (638 sources) in a wide range of redshifts (0.1 < z < 3.5) and X-ray luminosities (10{sup 41} < L {sub 0.5-10} <10{sup 45.5}). Both a simple statistical method to assess the significance of variability and the Normalized Excess Variance (σ{sub rms}{sup 2}) parameter were used to obtain a quantitative measurement of the variability. Variability is found to be prevalent in most AGNs, whenever we have good statistics to measure it, and no significant differences between type 1 and type 2 AGNs were found. A flat (slope –0.23 ± 0.03) anti-correlation between σ{sub rms}{sup 2} and X-ray luminosity is found when all significantly variable sources are considered together. When divided into three redshift bins, the anti-correlation becomes stronger and evolving with z, with higher redshift AGNs being more variable. We prove, however, that this effect is due to the pre-selection of variable sources: when considering all of the sources with an available σ{sub rms}{sup 2} measurement, the evolution in redshift disappears. For the first time, we were also able to study long term X-ray variability as a function of M {sub BH} and Eddington ratio for a large sample of AGNs spanning a wide range of redshifts. An anti-correlation between σ{sub rms}{sup 2} and M {sub BH} is found, with the same slope of anti-correlation between σ{sub rms}{sup 2} and X-ray luminosity, suggesting that the latter may be a by-product of the former. No clear correlation is found between σ{sub rms}{sup 2} and the Eddington ratio in our sample. Finally, no correlation is found between the X-ray σ{sub rms}{sup 2} and optical variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative methods and modeling to assess COVID–19–interrupted in vivo pharmacokinetic bioequivalence studies with two reference batches

The coronavirus disease 2019 (COVID-19) has presented unprecedented challenges to the generic drug development, including interruptions in bioequivalence (BE) studies. Per guidance published by the US Food and Drug Administration (FDA) during the COVID-19 public health emergency, any protocol changes or alternative statistical analysis plan for COVID-19-interrupted BE study should be accompanied with adequate justifications and not lead to biased equivalence determination. In this study, we used a modeling and simulation approach to assess the potential impact of study outcomes when two different batches of a Reference Standard (RS) were to be used in an in vivo pharmacokinetic BE study due to the RS expiration during the COVID-19 pandemic. Simulations were performed with hypothetical drugs under two scenarios: (1) uninterrupted study using a single batch of an RS, and (2) interrupted study using two batches of an RS. The acceptability of BE outcomes was evaluated by comparing the results obtained from interrupted studies with those from uninterrupted studies. The simulation results demonstrated that using a conventional statistical approach to evaluate BE for COVID-19-interrupted studies may be acceptable based on the pooled data from two batches. An alternative statistical method which includes a “batch” effect to the mixed effects model may be used when a significant “batch” effect was found in interrupted four-way crossover studies. However, such alternative method is not applicable for interrupted two-way crossover studies. Overall, the simulated scenarios are only for demonstration purpose, the acceptability of BE outcomes for the COVID19-interrupted studies could be case-specific.

60 APPLIED LIFE SCIENCES↗

coloring v.1.0

SAND2024-02435O The software coloring allows applications written in the C++ language to generate publication-quality 2D plots. Its functionality is similar to Microsoft Excel's chart functionality or the Python language's matplotlib package. The value of coloring is that it is written purely in C++ and thus can be compiled on systems where Python is not available and linked into high performance computing software. For drawing shapes onto an image, coloring uses the mathematical definition of quadratic Bezier splines and uses Newton's method to search for the closest point on a spline to a given query point. This is then used to do accurate sub-pixel sampling to get clean, non-pixelated images. For working with the actual plot data, coloring has basic statistical methods such as finding maxima and minima as well as axis scaling such as logarithms. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Ibanez, Daniel↗

Emerging anomaly detection techniques for electronic health records: A survey

Background Anomaly detection in electronic health records (EHRs) is a cornerstone of biomedical informatics, with direct implications for patient safety, clinical decision-making, and the prevention of healthcare fraud. Once guided primarily by simple rule-based methods, the field has advanced rapidly, driven by increased computing power, richer and more detailed health data, and the rise of machine learning and deep learning techniques. The objective of this paper is to provide a comprehensive overview of modern approaches to detecting anomalies in EHRs, outlining their strengths, limitations, and relevance to key healthcare challenges. We review traditional statistical methods alongside newer ML- and DL-based strategies and hybrid models, with particular attention to how these techniques support transparency and build clinical trust. Methods This paper presents a thorough and critical survey through systematic review (PRISMA-based) of the latest anomaly detection strategies in time-sequence data domains within electronic health record systems. Results We explore a broad spectrum of methodologies, including statistical models, supervised and unsupervised learning approaches, hybrid frameworks, and state-of-the-art ML-based techniques that collectively advance the precision and scalability of detecting anomalies in complex clinical datasets. In addition to mapping current capabilities, we address the enduring challenges that hinder widespread implementation and provide a forward-looking perspective on the future of anomaly detection in the data-rich landscape of modern healthcare. Summary The advancement in AI-based approaches is reported along with the basic principles of the individual approaches and their applicability. The increased availability of high-quality data, advancements in DL approaches, and enhanced computation power are leading to more frequent adaptation of DL-based approaches. Emerging DL-based approaches that have been adapted in other domains or recently applied in the EHR domain are also discussed in detail. Although DL-based approaches can improve model predictions by incorporating comorbidities, their application is limited in low-frequency data domains (e.g., when the total available data remains in the single digits). Therefore, the user must carefully consider the application based on data availability.

Anomaly detection↗

TURBULENT CHARACTERISTICS IN THE INTENSITY FLUCTUATIONS OF A SOLAR QUIESCENT PROMINENCE OBSERVED BY THE HINODE SOLAR OPTICAL TELESCOPE

We focus on Hinode Solar Optical Telescope (SOT) calcium II H-line observations of a solar quiescent prominence (QP) that exhibits highly variable dynamics suggestive of turbulence. These images capture a sufficient range of scales spatially ({approx}0.1-100 arcsec) and temporally ({approx}16.8 s-4.5 hr) to allow the application of statistical methods used to quantify finite range fluid turbulence. We present the first such application of these techniques to the spatial intensity field of a long-lived solar prominence. Fully evolved inertial range turbulence in an infinite medium exhibits multifractal scale invariance in the statistics of its fluctuations, seen as power-law power spectra and as scaling of the higher order moments (structure functions) of fluctuations which have non-Gaussian statistics; fluctuations {delta}I(r, L) = I(r + L) - I(r) on length scale L along a given direction in observed spatial field I have moments that scale as ({delta}I(r, L){sup p}) {approx} L{sup {zeta}(p)}. For turbulence in a system that is of finite size, or that is not fully developed, one anticipates a generalized scale invariance or extended self-similarity (ESS) ({delta}I(r, L){sup p}) {approx} G(L){sup {zeta}(p)}. For these QP intensity measurements we find scaling in the power spectra and ESS. We find that the fluctuation statistics are non-Gaussian and we use ESS to obtain ratios of the scaling exponents {zeta}(p): these are consistent with a multifractal field and show distinct values for directions longitudinal and transverse to the bulk (driving) flow. Thus, the intensity fluctuations of the QP exhibit statistical properties consistent with an underlying turbulent flow.

79 ASTRONOMY AND ASTROPHYSICS↗