Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Spectrometer technology recommendations

A typical heterodyne remote sensing system contains three major elements: the antenna, the radiometer, and the spectrometer. The radiometer consists of the local oscillator, the mixer, and the intermediate frequency amplifiers. This subsystem performs the function of down converting the high frequency incident thermal emission signal to a lower intermediate frequency. The spectrometer measures the power spectrum of the down-converted signal simultaneously in many contiguous frequency channels. Typical spectrum analysis requirements involve measurement of signal bandwidths of 100 to 1000 MHz with a channel resolution of 0.5 to 10 MHz. Three general approaches are used for spectrometers: (1) filter banks, (2) Acousto-Optic Spectrometers (AOS's), and (3) digital autocorrelators. In contrast to the two frequency domain techniques, an autocorrelator works in the time domain. The autocorrelation function (ACF) of the incoming signal is computed and averaged over the integration time. The averaged ACF is then Fourier transformed to obtain the signal power spectrum. Significant progress was made in the development of sub mm antennas and radiometers. It is now time to begin research in the development of low power spaceborne spectrometers and to reduce their size and weight. The near-term research goal will be to develop a prototype digital autocorrelation spectrometer, using VLSI gate array technology, which will have a small size, low power requirements, and can be used in spacecraft mm and sub mm radiometer systems. The long-range objective of this technology development is to make extremely low power, less than 10 mW/channel, small and stable wideband spectrometers which can be used in future mm and sub mm wavelength space missions such as the Large Deployable Reflector.

Wilson, William J.↗

Neural network acceleration of large-scale structure theory calculations

Here, we make use of neural networks to accelerate the calculation of power spectra required for the analysis of galaxy clustering and weak gravitational lensing data. For modern perturbation theory codes, evaluation time for a single cosmology and redshift can take on the order of two seconds. In combination with the comparable time required to compute linear predictions using a Boltzmann solver, these calculations are the bottleneck for many contemporary large-scale structure analyses. Here, we construct neural network-based surrogate models for Lagrangian perturbation theory (LPT) predictions of matter power spectra, real and redshift space galaxy power spectra, and galaxy-matter cross power spectra that attain ~ 0.1% (at one sigma) accuracy over a broad range of scales in a ωCDM parameter space. The neural network surrogates can be evaluated in approximately one millisecond, a factor of 1000 times faster than the full Boltzmann code and LPT computations. In a simulated full-shape redshift space galaxy power spectrum analysis, we demonstrate that the posteriors obtained using our surrogates are accurate compared to those obtained using the full LPT model. We make our surrogate models public at https://github.com/sfschen/EmulateLSS, so that others may take advantage of the speed gains they provide to enable rapid iteration on analysis settings, something that is essential in complex contemporary large-scale structure analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Operando XPS in reactive plasmas: The importance of the wall reactions

In this article, advancements in differential pumping and electron optics over the past few decades have enabled x-ray photoelectron spectroscopy (XPS) measurements at (near-)ambient pressures, bridging the pressure gap for characterizing realistic sample chemistries. Recently, we have demonstrated the capabilities of an ambient pressure XPS setup for in situ plasma environment measurements, allowing plasma-surface interactions to be studied in operando rather than using the traditional before-and-after analysis approach. This new “plasma-XPS” technique facilitates the identification of reaction intermediates critical for understanding plasma-assisted surface processes relevant to semiconductor nanomanufacturing, such as physical vapor deposition, etching, atomic layer deposition, and many other plasma applications. In this paper, we apply the plasma-XPS approach to monitor real-time surface chemical changes on a model Ag(111) single crystal exposed to oxidizing and reducing plasmas. We correlate surface-sensitive data with concurrent gas-phase XPS measurements and residual gas mass-spectrum analysis of species generated during plasma exposure, highlighting the significant role of plasma-induced chamber wall reactions. Ultimately, we demonstrate that plasma-XPS provides comprehensive insights into both surface and gas-phase chemistry, establishing it as a versatile and dynamic characterization tool with broad applications in microelectronics research. Finally, we outline potential enhancements and future metrology directions to advance plasma-XPS investigations further.

36 MATERIALS SCIENCE↗

Remote Radiation Sensing Using Aerial and Ground Platforms

Remote sensing of ionizing radiation has a significant role in waste management, nuclear material management and nonproliferation, and radiation safety. Robotic platforms can surpass the number of tasks that are achieved by humans. With this technique, the operator's radiation exposure can be decreased. Remote sensing allows for the evaluation and monitoring of radiological contamination. Gamma-ray and neutron sensors were integrated onto the robotic platforms. This approach allows for the radiation sensor data to be dynamically tracked and mapped thus enabling further analysis of the radiation flux in temporal and spatial domains. The goal is to complete scheduled tasks while the robot is being irradiated. To achieve this, electronic components must be shielded and radiation hardened. CZT Detector: Cadmium Zinc Telluride (CZT) detector technology has been a promising solution for gamma-ray and x-ray measurements. Detector data is transferred to the Odroid minicomputer that controls and powers the module via the USB. Robot Operating System (ROS) was utilized for data acquisition and data fusion. The Mariscotti method was employed for the spectrum analysis. A function was programmed in ROS for the automatic identification of photopeaks. CLYC Detector: A Cs{sub 2}LiYCl{sub 6}:Ce{sup 3+} (CLYC) detector was used for simultaneous medium-resolution gamma-ray measurements and neutron counting. A 2.54 cm diameter photomultiplier tube (PMT) was equipped with a high voltage supply and a miniature digitizer. Gamma-ray excitation: fast core-to-valence luminescence (CVL) with 1 ns decay constant, and prompt Ce{sup 3+} emission with 50 ns decay constant. Neutron excitation: slow cerium self-trapped excitation (Ce{sup 3+} STE), 1000 ns decay constant. Radiation Source Localization: Maximum Likelihood Estimation (MLE) and gradient-based methods were used to locate the position of a radiation source based on measured radiation intensities. Multi-Particle Transport Code FLUKA: Estimation of radiation damage of the electronic components is important in order to optimize the robot's operational time while it is irradiated. Displacement per atom (DPA) represents the radiation damage in materials exposed to the ionizing radiation. Various shielding layers of different thickness t were analyzed (< 5% statistical error). The model of the controller of the UAS was designed in FLUKA. Conclusion: CZT and CLYC detectors were integrated onto the robotic platforms. Radiation source localization and contour mapping using robotic platforms were studied. Functions for data analysis and fusion were developed in ROS. FLUKA code was utilized to analyze DPA values. Layers of low-density and high-density materials were used to shield the UAS electronics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-performance and scalable on-chip digital Fourier transform spectroscopy

Abstract On-chip spectrometers have the potential to offer dramatic size, weight, and power advantages over conventional benchtop instruments for many applications such as spectroscopic sensing, optical network performance monitoring, hyperspectral imaging, and radio-frequency spectrum analysis. Existing on-chip spectrometer designs, however, are limited in spectral channel count and signal-to-noise ratio. Here we demonstrate a transformative on-chip digital Fourier transform spectrometer that acquires high-resolution spectra via time-domain modulation of a reconfigurable Mach-Zehnder interferometer. The device, fabricated and packaged using industry-standard silicon photonics technology, claims the multiplex advantage to dramatically boost the signal-to-noise ratio and unprecedented scalability capable of addressing exponentially increasing numbers of spectral channels. We further explore and implement machine learning regularization techniques to spectrum reconstruction. Using an ‘elastic-D 1 ’ regularized regression method that we develop, we achieved significant noise suppression for both broad (>600 GHz) and narrow (<25 GHz) spectral features, as well as spectral resolution enhancement beyond the classical Rayleigh criterion.

47 OTHER INSTRUMENTATION↗

STEPWISE FILTER CORRELATION METHOD AND EVIDENCE OF SUPERPOSED VARIABILITY COMPONENTS IN GAMMA-RAY BURST PROMPT EMISSION LIGHT CURVES

Gamma-ray bursts (GRBs) have variable light curves. Although most models attribute the observed variability to one physical origin (e.g., central engine activity, clumpy circumburst medium, or relativistic turbulence), some models invoke two physically distinct variability components. We develop a method, namely, the stepwise filter correlation method, to decompose the variability components in a GRB light curve. Based on a low-pass filter technique, we progressively filter the high-frequency signals from the light curve, and then perform a correlation analysis between each adjunct pair of filtered light curves. Our simulations suggest that if a mock light curve contains a 'slow' variability component superposed on a rapidly varying time sequence, the correlation coefficient as a function of the filter frequency would display a prominent 'dip' feature around the frequency of the slow component. Through simulations, we demonstrate that this method can identify significant clustering structures of a light curve in the frequency domain, and we prove that it can catch superposed signals that are otherwise not easy to retrieve based on other methods (e.g., the power density spectrum analysis method). We apply this method to 266 Burst and Transient Source Experiment bright GRBs. We find that the majority of the bursts have clear evidence of such a superposition effect. We perform a statistical analysis of the identified variability components and discuss the implications for GRB physics.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrically interfaced Brillouin-active waveguide for microwave photonic measurements

New strategies for converting signals between optical and microwave domains could play a pivotal role in advancing both classical and quantum technologies. Traditional approaches to optical-to-microwave transduction typically perturb or destroy the information encoded on intensity of the light field, eliminating the possibility for further processing or distribution of these signals. In this paper, we introduce an optical-to-microwave conversion method that allows for both detection and spectral analysis of microwave photonic signals without degradation of their information content. This functionality is demonstrated using an optomechanical waveguide integrated with a piezoelectric transducer. Efficient electromechanical and optomechanical coupling within this system permits bidirectional optical-to-microwave conversion with a quantum efficiency of up to -54.16 dB. Leveraging the preservation of the optical field envelope in intramodal Brillouin scattering, we demonstrate a multi-channel microwave photonic filter by transmitting an optical signal through a series of electro-optomechanical waveguide segments, each with distinct resonance frequencies. Such electro-optomechanical systems could offer flexible strategies for remote sensing, channelization, and spectrum analysis in microwave photonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Winds aloft statistical analysis in support of day of launch Shuttle systems evaluation

In connection with the development of the Meteorological Interactive Data Display System (MIDDS) for utilization by the Launch Systems Evaluation Advisory Team (LSEAT), requirements have been established to expand the pre-launch analysis of winds aloft for the Space Shuttle. Statistical analyses developed for the system include: comparison of pre-launch wind component profiles to wind component extremes at each altitude calculated from launch site historical data; conditional probability ellipses for wind vectors at a future time given the wind vector at an initial time; comparison of observed extreme wind shear and associated wind speed with launch site historical data utilizing the bivariate extreme value (Gumbel) distribution; estimation of extremes of wind speed or wind shear at a future time given the extremes of either variable at an initial time, utilizing the conditional extreme value distribution; power spectrum analysis for tracking wind perturbation energy in sequential pre-launch Jimsphere wind profiles.

Adelfang, S. I.↗

Dynamic analysis of flexible rotor-bearing systems using a modal approach

The generalized dynamic equations of motion were obtained by the direct stiffness method for multimass flexible rotor-bearing systems. The direct solution of the equations of motion is illustrated on a simple 3-mass system. For complex rotor-bearing systems, the direct solution of the equations becomes very difficult. The transformation of the equations of motion into modal coordinates can greatly simplify the computation for the solution. The use of undamped and damped system mode shapes in the transformation are discussed. A set of undamped critical speed modes is used to transform the equations of motion into a set of coupled modal equations of motion. A rapid procedure for computing stability, steady state unbalance response, and transient response of the rotor-bearing system is presented. Examples of the application of this modal approach are presented. The dynamics of the system is further investigated with frequency spectrum analysis of the transient response.

Choy, K. C.↗

Enabling quantitative analysis of complex polymer blends by infrared nanospectroscopy and isotopic deuteration

Atomic-force microscopy coupled with infrared spectroscopy (AFM-IR) deciphers surface morphology of thin-film polymer blends and composites by simultaneously mapping physical topography and chemical composition. However, acquiring quantitative phase and composition information from multi-component blends can be challenging using AFM-IR due to the possible overlapping infrared absorption bands between different species. Isotope labeling one of the blend components introduces a new type of bond (carbon-deuterium vibration) that can be targeted using AFM-IR and responds at wavelengths sufficiently shifted toward unoccupied regions (around 2200 cm –1 ). In this project, AFM-IR was used to probe the surface morphology and chemical composition of three polymer blends containing deuterated polystyrene; each blend is expected to exhibit various degrees of miscibility. AFM-IR results successfully demonstrated that deuterium labeling prevents infrared spectral overlap and enables the visualization of blend phases that could not normally be distinguished by other scanning probe techniques. The nanoscale domain composition was resolved by fast infrared spectrum analysis. Overall, we presented isotope labeling as a robust approach for circumventing obstacles preventing the quantitative analysis of multiphase systems by AFM-IR.

36 MATERIALS SCIENCE↗

Design and Measurement of a Low-Noise 64-Channels Front-End Readout ASIC for CdZnTe Detectors

Cadmium zinc telluride (CdZnTe) detectors, as one of the principal detectors for the next-generation X-ray and γ-ray imagers, have high energy resolution and supporting electrode patterning in the radiation environment at room-temperature. In the present, a number of internationally renowned research institutions and universities are actively using these detector systems to carry out researches of energy spectrum analysis, medical imaging, materials characterization, high-energy physics, nuclear plant monitoring, and astrophysics. As the most important part of the readout system for the CdZnTe detector, the front-end readout application specific integrated circuit (ASIC) would have an important impact on the performances of the whole detector system. In order to ensure the small signal to noise ratio (SNR) and sufficient range of the output signal, it is necessary to design a front-end readout ASIC with very low noise and very high dynamic range. In addition, radiation hardness should be considered when the detectors are utilized in the space applications and high energy physics experiments. In this paper, we present measurements and performances of a novel multi-channel radiation-hardness low-noise front-end readout ASIC for CdZnTe detectors. The readout circuits in each channel consist of charge sensitive amplifier, leakage current compensation circuit (LCC), CR-RC shaper, S-K filter, inverse proportional amplifier, peak detect and hold circuit (PDH), discriminator and trigger logic, time sequence control circuit and driving buffer. All of 64 readout channels' outputs enter corresponding inputs of a 64 channel multiplexer. The output of the mux goes directly out of the chip via the output buffer. The 64-channel readout ASIC is implemented using the TSMC 0.35 μm mixed-signal CMOS technology. The die size of the prototype chip is 2.7 mm x 8 mm. At room temperature, the equivalent noise level of a typical channel reaches 66 e{sup -} (rms) at zero farad for a power consumption of 8 mW per channel. The linearity error is lower than 1% and the overall gain of the readout channel is 165 V/pC. The crosstalk between the channels is less than 3%. By connecting the readout ASIC to a CdZnTe detector, we obtained a γ-ray spectrum, the energy resolution is 5.1% at the 59.5-keV line of {sup 241}Am source. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interannual variability of the South Indian Countercurrent

In the present work, we investigate the interannual variability of the South Indian Countercurrent (SICC), a major and still understudied current of the Indian Ocean circulation. To characterize the interannual variability of the SICC, four different data sets (altimetry, GLORYS, OFAM3, and SODA) are analyzed using multiple tools, which include Singular Spectrum Analysis and wavelet methods. The quasi-biennial band dominates the SICC low-frequency variance, with the main peak in the 1.5–1.8 year interval. A secondary peak (2.1–2.5 year) is only found in the western basin. Interannual and decadal-type modulations of the quasi-biennial signal are also identified. In addition, limitations of SODA before the 1960s in the SICC region are revealed. Within the quasi-biennial band, the SICC system presents two main patterns with a multiple jet structure. One pattern is characterized by a robust northern jet, while in the other the central jet is well developed and northern jet is weaker. In both patterns, the southern jet has always a strong signature. Further, when the northern SICC jet is stronger, the northern cell of the subtropical gyre has a triangular shape, with its southern limb having a strong equatorward slant. The quasi-biennial variability of the SICC is probably related to the Indian Ocean tropical climate modes that are known to have a strong biennial characteristic.

54 ENVIRONMENTAL SCIENCES↗

Evaluating the mutagenicity of N-nitrosodimethylamine in 2D and 3D HepaRG cell cultures using error-corrected next generation sequencing

Human liver-derived metabolically competent HepaRG cells have been successfully employed in both two-dimensional (2D) and 3D spheroid formats for performing the comet assay and micronucleus (MN) assay. In the present study, we have investigated expanding the genotoxicity endpoints evaluated in HepaRG cells by detecting mutagenesis using two error-corrected next generation sequencing (ecNGS) technologies, Duplex Sequencing (DS) and High-Fidelity (HiFi) Sequencing. Both HepaRG 2D cells and 3D spheroids were exposed for 72 h to N-nitrosodimethylamine (NDMA), followed by an additional incubation for the fixation of induced mutations. NDMA-induced DNA damage, chromosomal damage, and mutagenesis were determined using the comet assay, MN assay, and ecNGS, respectively. The 72-h treatment with NDMA resulted in concentration-dependent increases in cytotoxicity, DNA damage, MN formation, and mutation frequency in both 2D and 3D cultures, with greater responses observed in the 3D spheroids compared to 2D cells. The mutational spectrum analysis showed that NDMA induced predominantly A:T → G:C transitions, along with a lower frequency of G:C → A:T transitions, and exhibited a different trinucleotide signature relative to the negative control. These results demonstrate that the HepaRG 2D cells and 3D spheroid models can be used for mutagenesis assessment using both DS and HiFi Sequencing, with the caveat that severe cytotoxic concentrations should be avoided when conducting DS. With further validation, the HepaRG 2D/3D system may become a powerful human-based metabolically competent platform for genotoxicity testing.

3D spheroids↗

Using Filter Methods to Guide Convergence for ADMM, with Applications to Nonnegative Matrix Factorization Problems

Nonconvex, nonlinear optimization problems arise naturally in parameter fitting and machine learning. While augmented Lagrangian methods have demonstrated robust convergence for classes of these problems, their convergence for block updates has been relatively unexplored outside of the context of the alternating direction method of multipliers (ADMM). ADMM has seen extensive use in these applications, but may exhibit uncertain convergence behavior in many practical nonconvex settings, and struggles with general nonlinear constraints. In contrast, filter methods have proved effective in enforcing convergence for sequential quadratic programming methods and interior point methods with feasibility criteria. We develop an ADMM-filter method for highly nonlinear and nonconvex problems. Here, we show convergence under mild assumptions for several types of coordinate descent schemes, and demonstrate our algorithm on nonnegative matrix factorization and completion problems in imaging and chemical spectrum analysis.

Nonconvex optimization↗

Long-lived contaminants in cyclotron-produced radiopharmaceuticals: measurement and dosimetry

Oxygenated target waters of cyclotron targets contain long-lived contaminants due to (p,n) reactions in the HAVAR target window that are spalled into the target water. These contaminants are largely removed during the synthesis of the final imaging agent. Currently the USP requires that the final drug product be 99.5% pure, so the total activity of the long-lived contaminants can be no more than 0.5% of the final radiopharmaceutical product. A method has been developed to identify and quantify the primary contaminants using high resolution gamma spectroscopy and VRF, a new spectrum analysis tool. Uptake, retention, and excretion functions for each of the contaminating isotopes in a soluble, injected chemical form have also been calculated using International Commission on Radiological Protection (ICRP) Publication 123 models and are presented in the Appendices A and B of Electronic Supplementary Material. In addition, specific organ and effective dose coefficients were also calculated using ICRP Publication 103 tissue weighting factors and are also presented in the Appendices A and B of Electronic Supplementary Material. As a result, typical imaging agents have contaminant loads far below the USP limit and contribute negligible doses to the patients receiving the drugs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Surface enhanced performance of La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ cathodes by infiltration Pr-Ni-Mn-O progress

Herein the present study reports the enhancement of electrochemical oxygen reduction activity of porous La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3–δ (LSCF) cathodes by coating a thin film of Pr-Ni-Mn oxide (PNM5) using a multi-step infiltration process. XRD examination reveals that PNM5 mainly contains a multiphase mixture of Pr 6 O 11 , PrNiO 3 , MnO and NiO. SEM morphology shows a thin PNM5 film and small particles are formed on the surface of LSCF backbone particles. Impedance spectrum analysis indicates that PNM5 infiltrated LSCF exhibits dramatically reduced polarization resistance (R p ), reaching R p of 0.244 Ω cm 2 at 973 K, which is one-half of the baseline LSCF cathode. The activation energy of LSCF cathodes infiltrated with PNM5 is 1.45 eV, slightly lower than the baseline LSCF cathode (1.77 eV). Distribution of relaxation time (DRT) function analysis shows PNM5 infiltration layer significantly promotes the oxygen reduction reaction (ORR) of cathode surface. With the increase in firing temperature, the total resistance increases and R p changes from ion transport to oxygen reduction reaction. Degradation rate of the PNM5-infiltrated LSCF is also lower, 0.02168% vs 0.07093% for the baseline LSCF over a 200-h period. A single cell testing indicated that the peak power density of the PNM5-infiltrated cell was increased by 140.66%. Overall, PNM5 could be a potential catalyst for boosting the performance of a commercial LSCF cathode for solid oxide fuel cells (SOFC).

36 MATERIALS SCIENCE↗

An unusual 3D interdigitated architecture assembled from Keggin polyoxometalates and dinuclear copper(II) complexes

A novel organic-inorganic hybrid compound, [Cu{sub 2}(bipy){sub 3}({mu}{sub 1}-H{sub 2}O){sub 2}({mu}{sub 2}-H{sub 2}O)({mu}{sub 2}-OH)(H{sub 2}BW{sub 12}O{sub 40})]{center_dot}4 H{sub 2}O (1) (bipy=4,4 Prime -bipy), has been synthesized in hydrothermal condition and characterized by elemental analysis, IR spectrum, TG analysis and single-crystal X-ray diffraction. Compound 1 possesses poly-pendant layered motifs composed of 12-tungstoborates and dinuclear copper(II) complexes, in which the mono-coordinated bipy molecules are orderly appended to both sides of the layer, respectively. Adjacent layers mutually engage in a zipper-like pattern to result in a novel 3D interdigitated architecture. The variable-temperature magnetic susceptibility of 1 showed that there existed weak antiferromagnetic interaction in 1. Toward the reduction of hydrogen peroxide, 1 has good electrocatalytic activity and remarkable stability. - A new compound has been obtained, which represents the first interdigitated architecture assembled by POMs and dinuclear copper(II) complexes. Highlights: Black-Right-Pointing-Pointer The first example of interdigitated architecture assembled by POMs and dinuclear copper(II) complexes is observed. Black-Right-Pointing-Pointer A zipper-like pattern is observed in the structure. Black-Right-Pointing-Pointer The IR, TG, XRPD, magnetism and electrochemical property of the title compound were studied.

36 MATERIALS SCIENCE↗