Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel technique applying spectral estimation to Johnson noise thermometry - 317

Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift free temperature measurements. The two techniques developed by Oak Ridge National Laboratory to remove transient and periodic EMI are briefly discussed in this paper. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying either technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: Oak Ridge National Laboratory, Sandia National Laboratory, and Tennessee Valley Authority (TVA) Kingston Steam Plant. Each of these locations enabled improvement on the EMI removal algorithm. The conclusions made from the results at each of these locations is discussed, as well as, possible future work. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nonlinear stimulated Brillouin scattering based photonic signal processors

Recent new methods in photonic signal processing based on stimulated Brillouin scattering, that enable the realization of photonic mixers with high conversion efficiency, ultra-wide continuously tunable high-resolution microwave photonic filters and programmable switchable microwave photonic tunable filters, are presented. These processors provide new capabilities for the realisation of high-performance and high-resolution signal processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nano-optomechanical transducer

A nano-optomechanical transducer provides ultrabroadband coherent optomechanical transduction based on Mach-wave emission that uses enhanced photon-phonon coupling efficiencies by low impedance effective phononic medium, both electrostriction and radiation pressure to boost and tailor optomechanical forces, and highly dispersive electromagnetic modes that amplify both electrostriction and radiation pressure. The optomechanical transducer provides a large operating bandwidth and high efficiency while simultaneously having a small size and minimal power consumption, enabling a host of transformative phonon and signal processing capabilities. These capabilities include optomechanical transduction via pulsed phonon emission and up-conversion, broadband stimulated phonon emission and amplification, picosecond pulsed phonon lasers, broadband phononic modulators, and ultrahigh bandwidth true time delay and signal processing technologies.

47 OTHER INSTRUMENTATION↗

Microwave Photonics for Distributed Sensing

In the past few years, microwave-photonics technologies have been investigated for optical fiber sensing. By introducing microwave modulation into the optical system, the optical detection is synchronized with the microwave modulation frequency. As a result, the system has a high SNR and thus an improved detection limit. In addition, the phase of the microwave-modulated light can be obtained and Fourier transformed to find the time-of-arrival information for distributed sensing. Recently, an incoherent optical-carrier-based microwave interferometry (OCMI) technique has been demonstrated for fully distributed sensing with high spatial resolution and large measurement range. Since the modal interference has little influence on the OCMI signal, the OCMI is insensitive to the types of optical waveguide. Motivated by the eeds of distributed measurement in the harsh environment, in the first part of this paper, several OCMI-based sensing systems were built by using special multimode waveguides to perform sensing for heavy duty applications. Driven by an interest on the high-resolution sensing, in the second part of the paper, I propose a coherence-gated microwave photonics interferometry (CMPI) technique, which uses a coherent light source to obtain the optical interference signal from cascaded weak reflectors. The coherence length of the light source is carefully chosen or controlled to gate the signal so that distributed sensing can be achieved. The experimental results indicate that the strain resolution can be better than 0.6 μ using a Fabry-Perot interferometer (FPI) iii with a cavity length of 1.5 cm. Further improvement of the strain resolution to the 1 n level is achievable by increasing the cavity length of the FPI to over 1m. The CMPI has also been utilized for distributed dynamic measurement of vibration by using a new signal processing method. The fast time-varying optical interference intensity change induced by the sub-scan rate vibration is recorded in the frequency domain. After Fourier transform, distinctive features are shown at the vibration location in the time domain signal, where the vibration frequency and intensity can be retrieved. The signal processing method supports vibration measurement of multiple points with the measurable frequency of up to 20 kHz.

Hua, Liwei↗

Search for a heavy Higgs boson decaying into two lighter Higgs bosons in the ττbb final state at 13 TeV

A search for a heavy Higgs boson H decaying into the observed Higgs boson h with a mass of 125 GeV and another Higgs boson hS is presented. The h and hS bosons are required to decay into a pair of tau leptons and a pair of b quarks, respectively. The search uses a sample of proton-proton collisions collected with the CMS detector at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 137 fb -1 . Mass ranges of 240–3000 GeV for m H and 60–2800 GeV for m h S are explored in the search. No signal has been observed. Model independent 95% confidence level upper limits on the product of the production cross section and the branching fractions of the signal process are set with a sensitivity ranging from 125 fb (for m H = 240 GeV) to 2.7 fb (for m H = 1000 GeV). These limits are compared to maximally allowed products of the production cross section and the branching fractions of the signal process in the next-to-minimal supersymmetric extension of the standard model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MA-NRBC: First successful attempt for neutron gamma discrimination in plastic scintillators

In this paper, a new electronic hardware and algorithms enabling discrimination between neutron and gamma in plastic scintillators together with the first associated experimental results, are presented. This electronic platform is mainly based onto a quad 200 MHz ADCs. Using phase rotating, it is possible to sample the signal up to 800 MHz equivalent, with 8 bits precision. This sampling frequency allows a real time signal processing. Despite all previous work, we have shown during this study that it is possible to discriminate neutron from gamma in plastic scintillators even for low energy neutrons (less than 10 MeV). Two patents have been accepted and registered; the first deals with the intrinsic signal processing and the second with thermal stabilization methods of photomultiplier tubes. The system could be used up to 100 000 events per second (both gamma and neutron). This system is currently dedicated to homeland security devices; this is due to its response time (in the order of 1 up to 3 seconds). The next step is to implement the thermal stabilization algorithm in the FPGA and micro-controller to obtain a global system free from any trouble caused by the environment thermal variations. This aspect of the research is crucial for measurements in the field. The time response should also be improved to make it a reliable alternative to Helium-3 shortage for neutron detection at borders checkpoint. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using pulse shape analysis to improve the position resolution of a resistive anode microchannel plate detector

Digital signal processing techniques were employed to investigate the joint use of charge division and risetime analyses for the resistive anode (RA) coupled to a microchannel plate detector (MCP). In contrast to the typical approach of using the relative charge at each corner of the RA, this joint approach results in a significantly improved position resolution. A conventional charge division analysis utilizing analog signal processing provides a measured position resolution of 170 μm (FWHM). By using the correlation between risetime and position we were able to obtain a measured resolution of 92μm (FWHM), corresponding to an intrinsic resolution of 64μm (FWHM) for a single Z-stack MCP detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Water Reactor Sustainability Program Potential to Extend the Range of Established Online Monitoring Technologies, Such as Guided Waves in Nuclear Power Plant Systems

The Light Water Reactor Sustainability Program began to evaluate technologies that could be used to perform online monitoring of piping and other secondary system structural components in commercial NPPs. These online monitoring systems have the potential to identify when a more detailed inspection is needed using real-time measurements, rather than at a pre-determined inspection interval. This transition to condition-based, risk informed automated maintenance will contribute to a significant reduction of operations and maintenance costs that account for most nuclear power generation costs. This report describes the current state of research related to ultrasonic guided wave testing and its application to defect detection in commercial nuclear power plants. The report analyses the applicability of the guided wave technology to secondary piping systems and also study the potential for expanding the range of guided wave technology to include bent piping and other piping components. The ultrasonic guided waves can inspect long stretches of straight piping, however more complex geometries such as elbows, welds, and tees are causing spurious reflections and coherent noise which significantly decrease the sensitivity of the technique. The report analyses two approaches to suppression of coherent noise in guided wave systems: advanced signal processing and pattern recognition based on independent component analysis and blind source separation and hardware-based technique of piezoelectric paint which can be used to facilitate the propagation of mechanical stress waves through piping. It is demonstrated on simulated guided wave data that the independent component analysis is capable of separating different coherent noise components and segregating them from useful signal. The piezoelectric paint approach seem to be a viable alternative to the signal processing methods, however it requires significantly more complicated logistics and initial financial outlay. The future efforts will be concentrated on applying the independent component analysis to real-world guided wave data recorded by the guided wave monitoring system installed on the shell of the low-pressure feedwater heater 13A at Exelon Corporation’s Braidwood Nuclear Generating Station. Also, the joint EPRI-INL research efforts will focus on experimental evaluation of piezoelectric paint as a technique to extend the range of guided wave technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strategies for simulating the time evolution of Hamiltonian lattice field theories

Simulating the time evolution of quantum field theories given some Hamiltonian H requires developing algorithms for implementing the unitary operator e -iHt . A variety of techniques exist that accomplish this task, with the most common technique used so far being Trotterization, which is a special case of the application of a product formula. However, other techniques exist that promise better asymptotic scaling in certain parameters of the theory being simulated, the most efficient of which are based on the concept of block encoding. In this work we study the performance of such algorithms in simulating lattice field theories. We derive and compare the asymptotic gate complexities of several commonly used simulation techniques in application to Hamiltonian lattice field theories. Using the scalar $\hat{φ}$ 4 theory as a test, we also perform numerical studies and compare the gate costs required by product formulas and signal-processing-based techniques to simulate time evolution. For the latter, we use the linear combination of unitaries (LCU) construction augmented with the quantum Fourier transform circuit to switch between the field and momentum eigenbases, which leads to immediate order-of-magnitude improvement in the cost of preparing the block encoding. Further, this paper also includes a pedagogical review of the techniques used, in particular product formulas, LCU, qubitization, quantum signal processing, as well as the technique for simulating geometrically-local Hamiltonians developed by Haah, Hastings, Kothari, and Low.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Queueing up for enzymatic processing: correlated signaling through coupled degradation

High-throughput technologies have led to the generation of complex wiring diagrams as a postsequencing paradigm for depicting the interactions between vast and diverse cellular species. While these diagrams are useful for analyzing biological systems on a large scale, a detailed understanding of the molecular mechanisms that underlie the observed network connections is critical for the further development of systems and synthetic biology. Here, we use queueing theory to investigate how ‘waiting lines’ can lead to correlations between protein ‘customers’ that are coupled solely through a downstream set of enzymatic ‘servers’. Using the E. coli ClpXP degradation machine as a model processing system, we observe significant cross-talk between two networks that are indirectly coupled through a common set of processors. We further illustrate the implications of enzymatic queueing using a synthetic biology application, in which two independent synthetic networks demonstrate synchronized behavior when common ClpXP machinery is overburdened. Our results demonstrate that such post-translational processes can lead to dynamic connections in cellular networks and may provide a mechanistic understanding of existing but currently inexplicable links.

59 BASIC BIOLOGICAL SCIENCES↗

Novel Modified Optical Fibers for High Temperature In-Situ Miniaturized Gas Sensors in Advanced Fossil Energy Systems

This report covers the technical progress on the program “Novel Modified Optical Fibers for High Temperature In-Situ Miniaturized Gas Sensors in Advanced Fossil Energy Systems”, funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed by the Materials Science & Engineering and Electrical & Computer Engineering Departments at Virginia Tech, and summarizes technical progress from July 1st, 2005 –June 30th, 2014. The objective of this program was to develop novel fiber materials for high temperature gas sensors based on evanescent wave absorption in optical fibers. This project focused on two primary areas: the study of a sapphire photonic crystal fiber (SPCF) for operation at high temperature and long wavelengths, and a porous glass based fiber optic sensor for gas detection. The sapphire component of the project focused on the development of a sapphire photonic crystal fiber, modeling of the new structures, fabrication of the optimal structure, development of a long wavelength interrogation system, testing of the optical properties, and gas and temperature testing of the final sensor. The fabrication of the 6 rod SPCF gap bundle (diameter of 70μm) with a hollow core was successfully constructed with lead-in and lead-out 50μm diameter fiber along with transmission and gas detection testing. Testing of the sapphire photonic crystal fiber sensor capabilities with the developed long wavelength optical system showed the ability to detect CO 2 at or below 1000ppm at temperatures up to 1000°C. Work on the porous glass sensor focused on the development of a porous clad solid core optical fiber, a hollow core waveguide, gas detection capabilities at room and high temperature, simultaneous gas species detection, suitable joining technologies for the lead-in and lead-out fibers and the porous sensor, sensor system sensitivity improvement, signal processing improvement, relationship between pore structure and fiber geometry to optical properties, and the development of a sensor packaging prototype for laboratory testing. Analysis and experiments determined that a bonding technique using a CO 2 laser is the most suitable joining technique. Pore morphology alteration showed that transmission improved with increasing annealing temperature (producing smaller pores), while the sensor response time increased and the mechanical strength decreased with increasing annealing temperature. Software was developed for data acquisition and signal processing to collect and interpret spectral gas absorption data. Gas detection on porous glass sensors was completed and the detection limit was evaluated using acetylene and was found to be around 1- 200ppm. A complete materials package for porous glass sensors was manufactured for testing.

36 MATERIALS SCIENCE↗

Methodology and Software for Gross Defect Detection of Spent Nuclear Fuel at the Atucha-I Reactor [Novel Methodology and Software for Spent Fuel Gross Defect Detection at the Atucha-I Reactor]

Here, fuel assemblies in the spent fuel pool are stored by suspending them in two vertically stacked layers at the Atucha Unit 1 nuclear power plant (Atucha-I). This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 wt% 235 U and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A gross defect detection tool, the spent fuel neutron counter (SFNC), has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups, the existing signal processing software of the tool was found to fail due to nonlinearity of the source term with burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Peri-prosthetic fracture vibration testing

The purpose of this study is to establish a test setup and vibration analysis method to predict femoral stem seating and prevent bone fracture using accelerometer or force response data from an instrument stem and impactor. This study builds upon earlier studies to identify a means to supplement a surgeon's tactile and auditory senses by using damage identification techniques normally used for civil and mechanical structures. Testing will be conducted using foam cortical shell sawbones prepared for stems of different geometries. Each stem will be instrumented with an accelerometer. Two impactor designs will be compared: a monolithic impactor with an integrated load cell and accelerometer and a two piece impactor. Acceleration and force measurements will be taken in the direction of impaction. Signal processing techniques will be applied to the acceleration time histories to determine features that can be used to assess device seating and potential fracture. A consistent energy input will be applied using a drop tower. The effect of introducing compliance under the bone support vise will also be investigated. The ultimate goal of this study is to design an integrated portable data acquisition system capable of being used in future cadaveric testing. This paper will discuss the experimental set-up, the signal processing techniques used and the subsequent results.

42 ENGINEERING↗

MREG V1.1 : a multi-scale image registration algorithm for SAR applications.

MREG V1.1 is the sixth generation SAR image registration algorithm developed by the Signal Processing&Technology Department for Synthetic Aperture Radar applications. Like its predecessor algorithm REGI, it employs a powerful iterative multi-scale paradigm to achieve the competing goals of sub-pixel registration accuracy and the ability to handle large initial offsets. Since it is not model based, it allows for high fidelity tracking of spatially varying terrain-induced misregistration. Since it does not rely on image domain phase, it is equally adept at coherent and noncoherent image registration. This document provides a brief history of the registration processors developed by Dept. 5962 leading up to MREG V1.1, a full description of the signal processing steps involved in the algorithm, and a user's manual with application specific recommendations for CCD, TwoColor MultiView, and SAR stereoscopy.

Eichel, Paul H.↗

Tailorable stimulated Brillouin scattering in nanoscale silicon waveguides

Nanoscale modal confinement is known to radically enhance the effect of intrinsic Kerr and Raman nonlinearities within nanophotonic silicon waveguides. By contrast, stimulated Brillouin-scattering nonlinearities, which involve coherent coupling between guided photon and phonon modes, are stifled in conventional nanophotonics, preventing the realization of a host of Brillouin-based signal-processing technologies in silicon. Here we demonstrate stimulated Brillouin scattering in silicon waveguides, for the first time, through a new class of hybrid photonic–phononic waveguides. Tailorable travelling-wave forward-stimulated Brillouin scattering is realized—with over 1,000 times larger nonlinearity than reported in previous systems—yielding strong Brillouin coupling to phonons from 1 to 18 GHz. Experiments show that radiation pressures, produced by subwavelength modal confinement, yield enhancement of Brillouin nonlinearity beyond those of material nonlinearity alone. In addition, such enhanced and wideband coherent phonon emission paves the way towards the hybridization of silicon photonics, microelectromechanical systems and CMOS signal-processing technologies on chip

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A New Method of Prompt Fission Neutron Energy Spectrum Unfolding

The prompt neutron emission in spontaneous fission of {sup 252}Cf has been investigated applying digital signal electronics along with associated digital signal processing algorithms. The goal was to find out the reasons of a long time existing discrepancy between theoretical calculations and the measurements of prompt fission neutron (PFN) emission dependence on the total kinetic energy (TKE) of fission fragments (FF). On the one hand the {sup 252}Cf(sf) reaction is one of the main references for nuclear data, on the other hand the understanding of PFN emission mechanism is very important for nuclear fission theory. Using a twin Frisch-grid ionization chamber for fission fragment (FF) detection and a NE213-equivalent neutron detector in total about 10{sup 7} fission fragment-neutron coincidences have been registered. Fission fragment kinetic energy, mass and angular distribution, neutron time-of-flight and pulse shape have been investigated using a 12 bit waveform digitizer. The signal waveforms have been analyzed using digital signal processing algorithms. For the first time the dependence of the number of emitted neutrons as a function of total kinetic energy (TKE) of the fragments is in very good agreement with theoretical calculations in the range of TKE from 140-220 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗