Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Seyfert galaxies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Hard X-ray tests of the unified model for an ultraviolet-detected sample of Seyfert 2 galaxies

An ultraviolet-detected sample of Seyfert 2 galaxies shows heavy photoelectric absorption in the hard X-ray band. The presence of UV emission combined with hard X-ray absorption argues strongly for a special geometry which must have the general properties of the Antonucci and Miller unified model. The observations of this sample are consistent with the picture in which the hard X-ray photons are viewed directly through the obscuring matter (molecular torus?) and the optical, UV, and soft X-ray continuum are seen in scattered light. The large range in X-ray column densities implies that there must be a large variation in intrinsic thicknesses of molecular tori, an assumption not found in the simplest of unified models. Furthermore, constraints based on the cosmic X-ray background suggest that some of the underlying assumptions of the unified model are wrong.

Mulchaey, John S.↗

The Ubiquity of AGN Winds in Seyfert 1 Galaxies at Low Redshift

The optical spectra of 3896 Seyfert 1 (Sy1) galaxies detected with WISE at z < 0.4 were analyzed for evidence of outflows. In 37% of the Sy1s in our sample, the outflows appear as broad, blue-shifted, spectrally resolved components of the [O iii]λ5007 Å emission line, with a mean maximum velocity V {sub max} ∼ 1014 km s{sup −1} that is consistent with AGN winds. For each Sy1, we deduced the black hole (BH) mass, bolometric luminosity, Eddington ratio, and power-law index of the continuum, which we compared with the star formation rate (SFR) and host morphology. Having separated our sample in two spectroscopic subgroups—Sy1s with only broad Balmer lines (Sy1B) and those with both narrow and broad (Sy1N) lines—and distinguishing those that show as outflow (Sy1Bw and Sy1Nw), we report the following differences: (1) the BH mass is systematically higher and the power-law steeper in the Sy1B–Sy1Bw than in the Sy1N–Sy1Nw; (2) V {sub max} is higher in the Sy1Bw than in the Sy1Nw, correlated in both groups with the BH mass and bolometric luminosity; (3) the Eddington ratio and SFR are higher in the Sy1 with outflows; and (4) the specific star formation rates (sSFRs) of the Sy1s are normal for their morphology and mass, typical of early-type spiral galaxies in the green valley, far from the quenched regime. From these results, we conclude that AGN winds in Sy1s are triggered by higher accretion rates and probably radiatively launched, and there is no clear evidence of an effect on the star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical and infrared spectrophotometry of 18 Markarian galaxies

Slit spectra, spectrophotometric scans and infrared broad band observations are presented. Eight of the program galaxies can be classified as Seyfert galaxies. Arguments are given that thermal, nonthermal and stellar radiation components were present. One group of Seyfert galaxies was characterized both by the presence of a high density region of gas and by a continuum dominated by nonthermal radiation. The continua of the remaining program Seyferts, which did not have a high density region of gas, were dominated by thermal radiation from dust and a stellar continuum. Ten of the galaxies, which are not Seyfert galaxies, are shown to be examples of extragalactic H 2 regions.

Becklin, E. E.↗

Optical and infrared spectrophotometry of 18 Markarian galaxies

Slit spectra, spectrophotometric scans, and infrared broad-band observations are presented for 18 Markarian galaxies with emission lines. Eight of the program galaxies can be classified as Seyfert galaxies. Arguments are given that thermal, nonthermal, and stellar radiation components are present. Broadly speaking, one group of Seyfert galaxies is characterized both by the presence of a high-density region of gas and by a continuum dominated by nonthermal radiation. The continua of the remaining program Seyferts, which do not have a high-density region of gas, are dominated by thermal radiation from dust and a stellar continuum. The 10 galaxies which are not Seyfert galaxies are shown to be examples of extragalactic H II regions; there is evidence for thermal emission from dust being present at 10 microns in four of these galaxies.

Neugebauer, G.↗

Gemini Near Infrared Field Spectrograph Observations of the Seyfert 2 Galaxy MRK 573: In Situ Acceleration of Ionized and Molecular Gas Off Fueling Flows

We present near-infrared and optical emission-line and stellar kinematics of the Seyfert 2 galaxy Mrk 573 using the Near-Infrared Field Spectrograph (NIFS) at Gemini North and Dual Imaging Spectrograph at Apache Point Observatory, respectively. By obtaining full kinematic maps of the infrared ionized and molecular gas and stellar kinematics in approximately 700 x 2100 pc(exp 2) circumnuclear region of Mrk 573, we find that kinematics within the Narrow-Line Region are largely due to a combination of both rotation and in situ acceleration of material originating in the host disk. Combining these observations with large-scale, optical long-slit spectroscopy that traces ionized gas emission out to several kpcs, we find that rotation kinematics dominate the majority of the gas. We find that outflowing gas extends to distances less than 1 kpc, suggesting that outflows in Seyfert galaxies may not be powerful enough to evacuate their entire bulges.

galaxies: active – galaxies: individual (Mrk 573↗

An Expanded RXTE Survey of Long-Term X-ray Variability in Seyfert 1 Galaxies

The first seven years of RXTE monitoring of Seyfert 1 active galactic nuclei have been systematically analyzed to yield five homogenous samples of 2-12 keV light curves, probing hard X-ray variability on successively longer durations from approx. 1 day to approx. 3.5 years. 2-10 keV variability on time scales of approx. 1 day, as probed by ASCA, are included. All sources exhibit stronger X-ray variability towards longer time scales, with variability amplitudes saturating at the longest time scales, but the increase is greater for relatively higher luminosity sources. The well-documented anticorrelation between variability amplitude and luminosity is confirmed on all time scales. However, anticorrelations between variability amplitude and black hole mass estimate are evident on only the shortest time scales probed. The data are consistent with the models of power spectral density (PSD) movement described in Markowitz et al. (2003) and McHardy et al. (2004), whereby Seyfert 1 galaxies variability can be described by a single, universal PSD shape whose cutoff frequency scales with black hole mass. The best-fitting scaling relations between variability time scale, black hole mass and X-ray luminosity support an average accretion rate of 2% of the Eddington limit for the sample. Nearly all sources exhibit stronger variability in the relatively soft 2-4 keV band compared to the 7-12 keV band on all time scales. Color-flux diagrams support also Seyfert 1s' softening as they brighten. There are indications that relatively less luminous or less massive sources exhibit a greater degree of spectral variability for a given increase in overall flux.

Markowitz, A.↗

Rapid X-ray variability from the Seyfert 1 Galaxy NGC 4051

Strong variable X-ray emission from the nearby low luminosity Seyfert 1 galaxy NGC 4051 was discovered during observations with the imaging proportional counter of the Einstein Observatory. During one 2304 second observation, the X-ray flux more than doubled in an approximately linear fashion, and a 70% increase for 150 seconds was seen during another 968 second observation. Evidence is presented which demonstrates that the X-ray spectrum of NGC 4051 is unusually soft compared to Seyfert 1 galaxies or QSOs. The emission mechanism is probably not synchrotron or synchrotron self-Compton, but the emission can be plausibly explained by various black hole accretion models.

Marshall, F. E.↗

Rapid X-ray variability from the Seyfert 1 galaxy NGC 4051

Strong variable X-ray emission from the nearby low luminosity Seyfert 1 galaxy NGC 4051 was discovered during observations with the imaging proportional counter of the Einstein Observatory. During one 2304 second observation, the X-ray flux more than doubled in an approximately linear fashion, and a 70 percent increase for 150 seconds was seen during another 968 second observation. Evidence is presented which demonstrates that the X-ray spectrum of NGC 4051 is unusually soft compared to Seyfert 1 galaxies or QSOs. The emission mechanism is probably not synchrotron or synchrotron self-Compton, but the emission can be plausibly explained by various black hole accretion models. Previously announced in STAR as N83-23265

Marshall, F. E.↗

Variable Iron K(alpha) Lines in Seyfert 1 Galaxies

We find that variability of the iron K alpha line is common in Seyfert 1 galaxies. Using data from the ASCA archive for objects that have been observed more than once during the mission, we study the time-averaged spectra from individual observations, thereby probing variability on timescales that range from days to years. Since the statistics of the data do not warrant searches for line variability in terms of a complex physical model, we use a simple Gaussian to model the gross shape of the line and then use the centroid energy, intensity, and equivalent width as robust indicators of changes in the line profile. We find that approximately 70% of Seyfert 1 galaxies (10 out of 15) show variability in at least one of these parameters: the centroid energy, intensity, and equivalent width vary in six, four, and eight sources, respectively. Because of the low signal-to-noise ratio, limited sampling, and time averaging, we consider these results to represent lower limits to the rate of incidence of variability. In most cases changes in the line do not appear to track changes in the continuum. In particular, we find no evidence for variability of the line intensity in NGC 4151, suggesting an origin in a region larger than the putative accretion disk, where most of the iron line has been thought to originate. Mrk 279 is investigated on short timescales. The time-averaged effective line energy (as measured by the Gaussian center energy, which is weighted by emission in the entire line profile) is 6.5 keV in the galaxy rest frame. As the continuum flux increases by 20% in a few hours, the Fe K line responds within approximately 10,000 seconds with the effective line energy increasing by 0.22 keV (approximately 10,500 kilometers per second). We also examine the ROSAT PSPC spectrum of Mrk 279 but find inconsistencies with ASCA. Problems with the ASCA and ROSAT calibration that affect simultaneous spectral fits at low energies are discussed in an appendix.

Weaver, K. A.↗

HEAO 1 observations of high-energy X-rays from the Seyfert I galaxy Mkn 509

The results of observations of the Seyfert I galaxy Mkn 509 at high X-ray energies (14-140 keV) with the UCSD/MIT instrument aboard HEAO 1 are reported. The source is detected at energies above 40 keV, and the spectrum is consistent with an extrapolation of the power-law spectrum obtained at lower X-ray energies. Observations on four separate days in 1978 October indicate that the source is varying on a time scale of days.

Dil, S.↗

Ultraviolet and optical spectrophotometry of the Seyfert 1.8 galaxy Markarian 609

Ultraviolet and optical observations of the Seyfert 1.8 galaxy Mrk 609 were collected simultaneously. The observations reveal strong line and continuum emission in the UV, an increase in the flux of H-beta and He I 5876, and a decrease in the H-alpha/H-beta value since the measurements by Osterbrock (1978, 1981), as well as an extended population of early-type stars, which is considered to be the source powering the larger part of the far-IR emission. Special attention is given to the origin of steep broad-line Balmer decrement measured by Osterbrock, since the strong UV continuum and the emission lines of Mrk 609 observed rule out reddening as the cause of the Balmer decrement. It is suggested that smaller-than-normal optical depths are likely to be the cause of the decrement.

Rudy, Richard J.↗

Radio and infrared observations of (almost) one hundred non-Seyfert Markarian galaxies

The 13 cm flux densities of 96 non-Seyfert Markarian galaxies were measured at Arecibo Observatory. Far infrared flux densities have been published for 78 of these galaxies in the IRAS catalog. The radio, infrared, and optical fluxes of these galaxies and of a magnitude limited sample of normal galaxies were compared to clarify the nature of the radio emission in Markarian galaxies. It was found that Markarian galaxies of a given apparent magnitude and Hubble type generally have radio fluxes several times higher that the fluxes typical of normal galaxies of the same magnitude and type. Remarkably, the ratio of radio flux to far infrared flux is nearly the same for most of these starburst galaxies and for normal spiral disks. However, the compact and peculiar Markarian galaxies consistently have about 60% more radio flux per unit infrared flux than the other Markarian galaxies and the normal spirals. It is not clear whether this difference reflects a difference in the evolution of the starbursts in these galaxies or whether there is excess radio emission of nonstellar origin.

Dressel, Linda L.↗

Hubble Space Telescope imaging of the Seyfert 2 galaxy NGC 2110

Hubble Space Telescope (HST) images of the Seyfert 2 galaxy NGC 2110 in the emission lines of (O III) lambda lambda-4959, 5007 and H-alpha + (N II) lambda lambda-6548, 6584 and the nearby continuum are presented. After deconvolution, the resolution of these images is approximately 0.1 sec, corresponding to a linear scale of approximately 23 pc at the assumed distance (46.8 Mpc) to this galaxy. The dominant line emission is associated with a strongly curved, narrow, 1 sec (230 pc) long feature emanating from the nucleus to the north. The morphology of this feature suggests that it may represent gas flowing outward from the nucleus (perhaps as a 'jet'). While this optical emission-line feature and the jetlike radio emission extend along a similar P.A., their detailed brightness distributions are loosely anticorrelated. In particular, there is no line emission associated with the off-nuclear 6 cm peaks and only weak radio emission along the optical 'jet'. On a larger scale, there is an S-shaped distribution of ionized gas (seen best in H-alpha) extending approximately 4 sec north and south of the nucleus. Ground-based kinematical data suggest this larger scale component represents normally rotating, ambient, interstellar gas photoionized by the central source. A continuum color map derived from HST observations shows evidence for an unresolved region (scale less than 23 pc) of very strong reddening at the location of the optical and radio nucleus. The location and size of the reddened region are consistent with obscuration by a dusty torus, but the observed reddening provides only a lower limit (A(sub V) greater than or equal to 4.6(sub -1.7 sup +1.2) mag) on the amount of obscuration to the nucleus. Nevertheless, this obscuration is sufficient to account for the 'energy deficit' previously reported in this object.

Mulchaey, John S.↗

HEAO 1 spectra of X-ray emitting Seyfert 1 galaxies

The paper presents the 2-50-keV X-ray spectra and time variability information on seven Seyfert 1 galaxies NGC 3783, NGC 4151, NGC 5548, NGC 6814, MK 509, MCG 8-11-11, and ESO 141-G55, obtained with the A2(2) experiment on HEAO 1. It is concluded that the spectra of Seyfert 1 galaxies can be well represented by flat power laws of high-temperature thermal breamsstrahlung models with relatively low column densities.

Mushotzky, R. F.↗

A multifrequency characterization of the extragalactic hard X-ray sky

Context: Nowadays, we know that the origin of the cosmic X-ray background (CXB) is mainly due to the integrated emission of active galactic nuclei. Therefore, in order to obtain a precise estimate of the contribution of different source classes to the CXB, it is crucial to achieve full characterization of the hard-X ray sky. Aims: We present a multifrequency analysis of all sources listed in the third release of the Palermo Swift-BAT hard X-ray catalog (3PBC) with the goal of (i) identifying and classifying the largest number of sources adopting multifrequency criteria, with particular emphasis on extragalactic populations and (ii) extracting sources belonging to the class of Seyfert galaxies to present here the release of the second version of the Turin-SyCAT. Methods: We outline a classification scheme based on radio, infrared (IR), and optical criteria that allows us to distinguish between unidentified and unclassified hard X-ray sources, as well as to classify those sources belonging to the Galactic and the extragalactic populations. Results: Our revised version of the 3PBC lists 1176 classified, 820 extragalactic, and 356 Galactic sources, as well as 199 unclassified and 218 unidentified sources. According to our analysis, the hard X-ray sky is mainly populated by Seyfert galaxies and blazars. For the blazar population, we report trends between the hard X-ray and the gamma-ray emissions based on the fact that a large fraction of them also have a counterpart detected by the Fermi satellite. These trends are all in agreement with the expectations of inverse Compton models which are widely adopted to explain the blazar broadband emission. For the Seyfert galaxies, we present the second version of the Turin-SyCAT, including a total of 633 Seyfert galaxies, with 282 new sources corresponding to an increase of ~80% with respect to the previous release. Comparing the hard X-ray and the infrared emissions of Seyfert galaxies, we confirm that there is no clear difference between the flux distribution of the infrared-to-hard X-ray flux ratio of Seyfert galaxies Type 1 and Type 2. However, there is a significant trend between the mid-IR flux and hard X-ray flux, confirming previous statistical results in the literature. Conclusions: We provide two catalog tables. The first is the revised version of the 3PBC catalog based on our multifrequency analyses. The second catalog table is a release of the second version of the Turin-SyCAT catalog. Finally, we highlight that extensive soft X-ray data are already available in the form of the Swift archive which can be used to search for potential counterparts of unidentified hard X-ray sources. All these datasets will be reduced and analyzed in a forthcoming analysis to determine the precise position of low-energy counterparts in the 0.5–10 keV energy range for 3PBC sources that can be targets of future optical spectroscopic campaigns; this is necessary to obtain their precise classification.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft X-ray spectra of Seyfert 2 galaxies

The paper presents soft X-ray spectra of three Seyfert 2 galaxies obtained with the ROSAT PSPC. For two of these objects, NGC 5506 and MCG -5-23-16, most of the flux occurs at energies greater than 1 keV and probably represents a low-energy extension of the source seen at higher (greater than 2 keV) energies. The third source, Mrk 348, has very little flux in the ROSAT band, suggesting a photoelectric cutoff at energies above the ROSAT band, in agreement with Ginga observations. In all three galaxies, X-rays are detected at energies below these photoelectric cutoffs with flux above that expected from a model in which the source has the same spectral index as at higher energies (2-10 keV) and is covered by a uniform, cold, photoelectric absorber. This result indicates the presence of an additional component at soft energies, which is referred to as a 'soft excess'. The monochromatic flux of the soft excess measured at 1 keV is about 1-2 percent of the directly viewed hard X-ray continuum in all three galaxies.

Mulchaey, John S.↗

New hard X-ray sources observed with HEAO-A2

A search for new hard X-ray sources using data from the first complete view of the sky with the HEAO-A2 experiment discovered 47 new sources, detected 7 sources recently discovered with other experiments, and significantly reduced the size of the error boxes for 6 previously known sources. Intensities and error boxes are given for each of these sources; identifications are suggested when an error contains an object similar to known X-ray sources. The new identifications consist of seven Type 1 Seyfert galaxies, including two whose Seyfert characteristics were discovered due to their location in an X-ray error box; one intermediate Seyfert galaxy; three Abell clusters; five N-galaxies; two bursting radio sources; and an additional three nearby galaxies with bright nuclei and narrow emission lines.

Marshall, F. E.↗

New hard X-ray sources observed with HEAO A-2

A search for new hard X-ray sources using data from the first complete view of the sky with the HEAO A-2 experiment has discovered 47 new sources, detected seven sources recently discovered with other experiments, and significantly reduced the size of the error boxes for six previously known sources. Intensities and error boxes are given for each of these sources; identifications are suggested when an error box contains an object similar to known X-ray sources. The new identifications consist of seven type 1 Seyfert galaxies, including two whose Seyfert characteristics were discovered as a result of their location in an X-ray error box; one intermediate Seyfert galaxy; three Abell clusters; five N galaxies; two bursting radio sources; and an additional three nearby galaxies with bright nuclei and narrow emission lines.

Marshall, F. E.↗