Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Service Quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Cloud-Control of Legacy Building Automation System: A case study

As Internet of Things devices and cloud-based platforms become more mature, Energy Management and Information Systems (EMIS) are increasingly gaining momentum in the building industry. In large commercial buildings, Fault-Detection and Diagnostic (FDD) and energy information systems (EIS) are now established technologies with tens of providers and thousands of deployment sites across North America. The new frontier for the EMIS technology is now represented by control systems that use advanced system optimization (ASO) methods to improve the operations of the HVAC system. Given the complexity of the integration of such systems with the existing building automation systems (BAS) and the higher risk involved with direct control of the HVAC, these systems are still emerging in the market. This paper presents the results of a project in which a start-up company partnered with a research institution to develop a cloud-based software EMIS solution and deployed it in a university campus in California. The software system included advanced sensing, data acquisition, storage and advanced control and analytics applications developed on top of the native BAS. The new platform controls ten buildings on the campus and the FDD and the ASO applications deployed on this platform were able to generate energy savings of up to 35% and 25% in certain buildings for each functionality respectively. Where the platform did not save energy, it improved building service (air quality). Lessons learned include the importance of collaborating with and training the building operators and evaluating whether the legacy system can work reliably with the new technology.

Prakash, Anand Krishnan↗

Bishop Paiute Weatherization Training Program

The DOE Weatherization Training Grant assisted Native American trainees in developing weatherization competencies, creating employment opportunities for Bishop Paiute tribal members in a growing field. The trainees completed all the necessary training and certification requirements and delivered high-quality weatherization services on the Bishop Paiute Reservation. Six tribal members received all three certifications for weatherization; four of the trainees are currently employed. The public benefit includes (1) development of marketable skills by low-income Native individuals, (2) employment for low-income Native individuals in a growing industry, and (3) economic development opportunities that were previously not available to these individuals or the Tribe.

99 GENERAL AND MISCELLANEOUS↗

Use of Residential Smart Appliances for Peak-Load Shifting and Spinning Reserves Cost/Benefit Analysis

In this report, we present the results of an analytical cost/benefit study of residential smart appliances from a utility/grid perspective in support of a joint stakeholder petition to the ENERGY STAR program within the Environmental Protection Agency (EPA) and Department of Energy (DOE). The goal of the petition is in part to provide appliance manufacturers incentives to hasten the production of smart appliances. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the societal challenges, such as anthropogenic global warming, associated with increased electricity demand, and facilitate increased penetration of renewable sources of power. The appliances we consider include refrigerator/freezers, clothes washers, clothes dryers, room air-conditioners, and dishwashers. The petition requests the recognition that providing an appliance with smart grid capability, i.e., products that meet the definition of a smart appliance, is at least equivalent to a corresponding five percent in operational machine efficiencies. It is then expected that given sufficient incentives and value propositions, and suitable automation capabilities built into smart appliances, residential consumers will be adopting these smart appliances and will be willing participants in addressing the aforementioned societal challenges by more effectively managing their home electricity consumption. The analytical model we utilize in our cost/benefit analysis consists of a set of user-definable assumptions such as the definition of on-peak (hours of day, days of week, months of year), the expected percentage of normal consumer electricity consumption (also referred to as appliance loads) that can shifted from peak hours to off-peak hours, the average power rating of each appliance, etc. Based on these assumptions, we then formulate what the wholesale grid operating-cost savings, or benefits, would be if the smart capabilities of appliances were invoked, and some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads served power-system balancing needs such as spinning reserves that would otherwise have to be provided by generators. The rationale is that appliance loads can be curtailed for about ten minutes or less in response to a grid contingency without any diminution in the quality of service to the consumer. We then estimate the wholesale grid operating-cost savings based on historical wholesale-market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States. The savings derived from the smart grid capabilities of an appliance are then compared to the savings derived from a five percent increase in traditional operational machine efficiencies, referred to as cost in this report, to determine whether the savings in grid operating costs (benefits) are at least as high as or higher than the operational machine efficiency credit (cost).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using the Sirocco File System for high-bandwidth checkpoints.

The Sirocco File System, a file system for exascale under active development, is designed to allow the storage software to maximize quality of service through increased flexibility and local decision-making. By allowing the storage system to manage a range of storage targets that have varying speeds and capacities, the system can increase the speed and surety of storage to the application. We instrument CTH to use a group of RAM-based Sirocco storage servers allocated within the job as a high-performance storage tier to accept checkpoints, allowing computation to potentially continue asynchronously of checkpoint migration to slower, more permanent storage. The result is a 10-60x speedup in constructing and moving checkpoint data from the compute nodes. This demonstration of early Sirocco functionality shows a significant benefit for a real I/O workload, checkpointing, in a real application, CTH. By running Sirocco storage servers within a job as RAM-only stores, CTH was able to store checkpoints 10-60x faster than storing to PanFS, allowing the job to continue computing sooner. While this prototype did not include automatic data migration, the checkpoint was available to be pushed or pulled to disk-based storage as needed after the compute nodes continued computing. Future developments include the ability to dynamically spawn Sirocco nodes to absorb checkpoints, expanding this mechanism to other fast tiers of storage like flash memory, and sharing of dynamic Sirocco nodes between multiple jobs as needed.

99 GENERAL AND MISCELLANEOUS↗

Report on DOE support for GSC13 travel award

Consortium. The 3-day conference was held at the Kingkey Palace Hotel, Shenzhen, China, on March 5-7th, 2012, and was hosted by the Beijing Genomics Institute (BGI). The meeting was entitled ‘From Genomes to Interactions to Communities to Models’ and aimed to be a scientific meeting that highlighted the role of data standards associated with genomic, metagenomic and amplicon sequence data, and the contextual information associated with the sample that data was generated from. To this end the meeting focused on genomic projects for animals, plants, fungi and viruses, metagenomic studies in host-microbe interactions, and community dynamics in microbial communities. In addition the meeting hosted a Genomic Observatories Network session, a GSC biodiversity working group session, and a Microbiology of the Built Environment session sponsored by the Alfred P. Sloan Foundation. The meeting was very well organized by the local hosts at BGI, and all attendees reported that they were very happy with the outcome, service and quality of the science presented. Highlights were keynotes by Rita Colwell, Mitch Sogin and Jim Tiedje. The 5 attendees paid for by the DOE award were Daniel Smith and Jared Wilkening (University of Chicago); Patrick Chain (Los Alamos National Laboratory), Austin Davis-Richardson (University of Florida) and Greg Caporoaso (University of Northern Arizona). Each attendee was able to either present or become involved with the attending scientists, and each reported that they had got something significant out of the meeting. Here are detailed their personal accounts of the GSC13 meeting. We thank DOE for the helping to fund this valuable outreach initiative, and for supporting the attendance of these bright young scientists at this important meeting.

59 BASIC BIOLOGICAL SCIENCES↗

Coordinated Multi-layer Multi-domain Optical Network (COMMON) for Large-Scale Science Applications (COMMON)

We intend to implement a Coordinated Multi-layer Multi-domain Optical Network (COMMON) Framework for Large-scale Science Applications. In the COMMON project, specific problems to be addressed include 1) anycast/multicast/manycast request provisioning, 2) deployable OSCARS enhancements, 3) multi-layer, multi-domain quality of service (QoS), and 4) multi-layer, multidomain path survivability. In what follows, we outline the progress in the above categories (Year 1, 2, and 3 deliverables).

Vokkarane, Vinod↗

Coordination and Control of Flexible Building Loads for Renewable Integration; Demonstrations using VOLTTRON

Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivation and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate variable generation sources. The flexible loads can successfully track a power dispatch signal from the coordinator, while having little impact on the quality of service to the end-users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic Characterization of Communication Network Latency for Wide Area Grid Control Applications.

This report characterizes communications network latency under various network topologies and qualities of service (QoS). The characterizations are probabilistic in nature, allowing deeper analysis of stability for Internet Protocol (IP) based feedback control systems used in grid applications. The work involves the use of Raspberry Pi computers as a proxy for a controlled resource, and an ns-3 network simulator on a Linux server to create an experimental platform (testbed) that can be used to model wide-area grid control network communications in smart grid. Modbus protocol is used for information transport, and Routing Information Protocol is used for dynamic route selection within the simulated network.

97 MATHEMATICS AND COMPUTING↗

A Scalable HPC Insider Threat Monitoring System

Cyber Equations, Inc. is reporting on the results of its DOE SBIR Phase I project for the development of a Scalable HPC Insider Threat Monitoring System. This final report to the Department of Energy for Task DE-FOA-0001618 covers the period from 02/21/2017 to 02/20/2018 and summarizes the larger research accomplishments, which can be divided in theoretical and laboratory experiments. One of the many challenges for the U.S. Department of Energy (DOE) is the support of the high-performance computing (HPC) centers while providing quality information services, strategic vision, leadership, technical expertise, and capabilities necessary to enable the DOE to deliver effective, efficient, economical, and secure HPC services. In order to realize a secure DOE laboratory enterprise, DOE facilities operations must counter a wide range of cyber insider threats, from unsophisticated adversaries up to advanced, nation state sponsored actors. The DOE laboratories also presents an enormous insider attack surface of an ever-growing number of computers, networks, and devices all running a myriad of software. In addition, the DOE laboratories are connected to a variety of external organizations which multiplies the possibility of insider threat. During this SBIR project Cyber Equations developed a strategic combination of supervised and unsupervised machine learning techniques to control scale and classify whether entities, such as hosts, actors, or documents, are showing suspicious insider behavior. We conducted experiments using real cyber data to show that changes in observable behavior (e.g., changes in outbound traffic patterns) are indicative of attacks executing (e.g., insiders exfiltrating data, bots calling home, or an attack spreading). The features and methods we use, have been used in the anomaly detection research and development community for a significant amount of time and robust implementations are openly available. K-Means clustering, Decision Trees, and Support Vector Machine based classifiers are readily available through the R language and open source H20 machine learning framework. The Cyber Equations approach is novel in its use of these classifiers combined with Hadoop based parallel processing technology. The five stages of processing used by CyberInsider improve scalability and reduce the high number of false positives normally associated with network anomaly detection. In summary, the Cyber Equations has successfully accomplished all of its Phase I tasks and demonstrated the feasibility of the Insider Threat Monitoring System.

97 MATHEMATICS AND COMPUTING↗

Performance Understanding and Analysis for Exascale Data Management Workflows (Collaboration)

The general approach of the MONA project is depicted in Figure 1. The figure shows performance monitoring applied to an I/O workflow associated with a scientific simulation, with online measurements captured from this workflow informing methods for workflow reconfiguration and dynamic adjustment. The goal is to maintain suitable levels of Quality of Service for workflow execution, by understanding the underlying causes of workflow performance and behavior. One outcome will be workflow performance models able to characterize realistic workflows. Another outcome will be performance ‘mini-apps’ implementing such workflow behavior. Out of scope for this project are advanced methods for online workflow control.

97 MATHEMATICS AND COMPUTING↗

Performance Understanding and Analysis for Exascale Data Management Workflows

The goal of the Exascale Data Management Workflows project is to create tools to support techniques for in-situ data analysis and data management. Online data management co-running with simulations accelerates the scientific processes being carried out, provides rapid and timely scientific insights, and can help avoid unnecessary and scientifically invalid simulation computations, particularly when combined with or able to utilize data from experimental instrument and/or from past simulation runs. The University of Oregon team is contributing to the performance instrumentation and analysis aspect of this project. Our focus has been on efficient performance monitoring of data management at scale. The general approach of the MONA project is depicted in Figure 1 below. The figure shows performance monitoring applied to an I/O workflow associated with a scientific simulation, with online measurements captured from this workflow informing methods for workflow reconfiguration and dynamic adjustment. The goal is to maintain suitable levels of Quality of Service for workflow execution, by understanding the under lying causes of workflow performance and behavior. One outcome is workflow performance models able to characterize realistic workflows. Another outcome is performance ’mini-apps’ implementing such workflow behavior. Out of scope for this project are advanced methods for online workflow control.

97 MATHEMATICS AND COMPUTING↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Hyperloop Technologies on the Electric Grid and Transportation Energy

Hyperloop technology, initially proposed in 2013 as an innovative means for intermediate range or intercity travel, is now being developed by several companies. Proponents point to potential benefits for both passenger travel and freight transport, including time-savings, convenience, quality of service and, in some cases, increased energy efficiency. Because the system is powered by electricity, its interface with the grid may require strategies that include energy storage. The added infrastructure, in some cases, may present opportunities for gridwide system benefits from integrating hyperloop systems with variable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tariff Setting in the District Heating Sector: Recommendations Based on International Experience

Ukraine’s district heating (DH) system is an essential resource for the country and has the potential to provide efficient, local, and renewable energy to a large share of the population. However, inefficient regulation and management have caused the sector to experience a vicious cycle of financial, operational, and technological problems. Overcoming these challenges and building a sustainable DH system requires comprehensive reforms, which could attract significant investment, improve the quality of services, and increase the efficiency of DH. One of the key elements of a comprehensive reform program should be a comprehensive reform of the tariff system. The purpose of this report is to provide analysis of European models for tariff regulation and recommendations for reforms to Ukraine’s DH tariff system. The report presents several case studies from European countries, followed by analysis of the current tariff system in Ukraine and barriers to effective regulation. Based on these findings, the report proposes actions Ukraine could take to improve the tariff regulatory system and promote a sustainable DH sector.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Evaluation of Interference in 2.4 GHz Wireless Network

To attain automation across different applications, nuclear power plants are beginning to leverage advancements in wireless communication technologies. A “one-size-fits-all” solution cannot be applied since wireless technologies are selected according to application needs, quality of service requirements, and economic restrictions. To balance the trade-off between technical and economic requirements, a multi-band heterogeneous wireless network architecture is needed. Numerous wireless technologies including Wi-Fi, Zigbee, and Bluetooth share the 2.4 GHz industrial, scientific, and medical band. However, due to different channel access mechanisms and transmit power levels, and very importantly, uncoordinated use, coexistence of these devices in the same vicinity can cause interference and degradation in performance. This report provides the technical basis for understanding the coexistence of these wireless technologies through an experimental evaluation of their performance. This report investigates interactions encompassing variables such as transmission power level, distance between the devices, data rates, and the utilization of co-channel or adjacent channels. The results show that the operation of both Zigbee and Bluetooth is severely compromised when coexisting with Wi-Fi within the same frequency spectrum. On the other hand, the performance of Bluetooth is not impaired by Zigbee and vice versa unless there exists any external interference from Wi-Fi.

2.4 GHz↗

Compliance of NNSS Activities with P322-4 Issues Management and NNSSWAC Requirements

The Institutional Quality and Performance Assurance Division's Quality Support Services Group conducted a surveillance of the compliance of Waste Management Program activities to Issues Management/Corrective Action requirements communicated in P322-4 and the Nevada National Security Site Waste Acceptance criteria (NNSSWAC). All corrective actions reviewed and records examined were found to be compliant with appropriate and relevant procedures. There were no Findings or Opportunities for Improvement noted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surveillance LANL-ASMT-2026-0059 Procurement – NNSS Supplier Review

The Institutional Quality and Performance Assurance Division's Quality Support Services Group conducted a surveillance of IQPA-IQ Supplier Evaluation group's required assessments of suppliers providing items and services relevant to the Nevada National Security Site. Based upon records examined, the surveillance team has determined that all supplier evaluation/oversight requirements are being met, and no Findings or Opportunities for Improvement are noted.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Best Practices for Grid Communications

As the grid evolves, the communications architecture will need to evolve with it. That architecture affords a structured means by which the evolving complexities of the modern electric grid can be managed. This document provides best practices that can be implemented in the grid of today and evolve towards the grid and grid architecture of the future. The evolving grid and its control communications increasingly rely on commercial communications providers and a variety of technologies, from wireless (e.g., 5G, microwave, Wi-Fi) to wireline (fiber, copper) to radio communications (P25, other repeater-based systems), and all these communications systems rely on electric power. A reliable and resilient grid must account for this complex set of interdependencies in its planning activities, especially those involving restoration and recovery. The participation of all relevant parties in both planning and exercising of plans can prevent unexpected conditions that impede the reliable operation and recovery of the grid. Best practices for grid communications include using a Network Management System to document the operational state, define and monitor baselines, detect changes, and accelerate response to abnormalities. If transitioning from SONET to IP/packet-based systems, translating grid requirements into communications requirements for latency, bandwidth and throughput, IP packet delay variation, packet loss, and availability should inform and drive technology planning and selection as well as that communication system’s Quality of Service (QoS) policies and Service Level Agreements (SLAs). Secure and reliable timing is another key component of a reliable and resilient grid that can operate through adverse events. A trusted internal NTP configuration, an integrated and diverse timing delivery system, optimizing the timing architecture based on the transport technologies of the communications system, and using established standards can deliver the level of timing accuracy required by a range of time-sensitive power system applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗