Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURGERY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Intrusions into the lower stratospheric Arctic vortex during the winter of 1991-1992

Investigations of the kinematics of the lower stratospheric Arctic vortex during the winter of 1991-1992 using the contour advection with surgery technique reveal three distinct events in which there was substantial intrusion of midlatitude air into the vortex, in apparent contradiction of the view that the polar vortex constitutes an isolated air mass. Two of these events, in late January and mid-February, were well documented. They were predicted in high-resolution forecasts by the European Centre for Medium-Range Weather Forecasts, most clearly in experimental forecasts with reduced diffusion. Direct confirmation of the presence of the intrusions and of their calculated locations was provided by aerosol observations from the airborne differential absorption laser lidar aboard the NASA DC-8, taken as part of the second Airborne Arctic Stratospheric Expedition campaign; aerosol-rich air of midlatitude origin was seen in the expected position of the intrusions. The reality of the February event was also confirmed by in situ measurements from the NASA ER-2. Such events may be significant for the chemical processes taking place within the winter vortex. The intrusions were evidently related to the meteorology of the northern stratosphere during this winter and in particular to persistent tropospheric blocking over the northeastern Atlantic Ocean and western Europe and concomitant ridging into the lower stratospheric vortex in this region. Nevertheless, preliminary investigations have indicated that such events are not uncommon in other northern hemisphere winters, although no such events were found in the southern hemisphere during the Antarctic winter of 1987.

Plumb, R. A.↗

Microvascular responses to body tilt in cutaneous maximus muscle of conscious rats

We investigated microvascular responses to head-up tilt (HUT) and head-down tilt (HDT) in striated muscle of conscious male rats. To observe the microcirculation in the cutaneous maximus muscle, a transparent polycarbonate chamber was implanted aseptically into a skin fold created between the shoulders. Rats were trained to sit quietly during HUT and HDT while positioned on a horizontal microscope that rotated in the sagittal plane. At 4-5 days after surgery, arteriole and venule diameters were recorded using videomicroscopy while the rat experienced 10 min each (in random order) of HUT or HDT at 20 deg or 40 deg separated by 2-h rest periods. HUT had no affect on microvessel diameter; 20 deg HDT had little affect. In response to 40 deg HDT, 'large' arterioles constricted by 18 +/- 2% and 'small' arterioles dilated by 21 +/- 3%; this difference suggested variation in mechanisms controlling arteriolar responses. Venules exhibited a larger fluctuation in diameter during 40 deg HDT compared with other body positions, suggesting that venomotor activity may be induced with sufficient fluid shift or change in central venous pressure. These observations illustrate a viable model for studying microvascular responses to gravitational stress in conscious rats.

Puri, Rohit K.↗

A Compact Fiber Optic Eye Diagnostic System

A new fiber optic probe developed for determining transport properties of sub-micron particles in fluid experiments in a microgravity environment has been applied to study different parts of an eye. The probe positioned in front of an eye, delivers a low power (approximately few microW) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like materials in the vitreous humor. In a clinical setting, the probe can be mounted on a standard slit-lamp apparatus simply using a Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

Ophthalmic Diagnostics Using a New Dynamic Light Scattering Fiber Optic Probe

A new fiber optic probe is developed to study different parts of the eye. The probe positioned in front of an eye, delivers a low power light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. We report alpha-crystalline size distributions, as a function of penetration depth, inside the lens and hyaluronic acid molecular size distribution in the vitreous body. In a clinical setting, the probe can be mounted on a slit-lamp apparatus simply by using a H-ruby lens holder. The capability of detecting cataracts, both nuclear and peripheral, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before surgery is necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber, e.g., posterior vitreous detachment.

Ansari, Rafat R.↗

A Compact Fiber Optic Eye Diagnostics System

A new fiber optic probe development for determining transport properties of sub-micron particles in fluids experiments in a microgravity environment has been applied to study different parts of the eye. The probe positioned in front of an eye, delivers a low power (approximately a few mu W) light from a laser diode into the eye and guides the light which is back scattered by different components (aqueous humor, lens, and vitreous humor) of the eye through a receiving optical fiber to a photo detector. The probe provides rapid determination of macromolecular diffusivities and their respective size distributions in the eye lens and the gel-like material in the vitreous humor. For a clinical use, the probe is mounted on a standard slit-lamp apparatus simply using Hruby lens holder. The capability of detecting cataracts, both nuclear and cortical, in their early stages of formation, in a non invasive and quantitative fashion, has the potential in patient monitoring and in developing and testing new drugs or diet therapies to 'dissolve' or slow down the cataract formation before the surgery becomes necessary. The ability to detect biochemical and macromolecular changes in the vitreous structure can be very useful in identifying certain diseases of the posterior chamber and their complications, e.g., posterior vitreous detachment and diabetic retinopathy.

Ansari, Rafat R.↗

A Well Connected Future: Networking Trends

It is clear networks of various types are beginning to have a substantial impact on every aspect of our lives, our jobs, society and the way we perceive and use information. Commerce is moving onto the Internet; doctors are performing surgery and diagnosis with the aid of high performance networks and satellites; and political revolutions and coups are reported through the use of networks. This is only the first glimpse of what is yet to come. This paper is a brief survey of technology research in networking, with emphasis on the use of satellites present and future as a component of a global information mesh.

St.Johns, Michael↗

Design of a Bearingless Blood Pump

In the field of open heart surgery, centrifugal blood pumps have major advantages over roller pumps. The main drawbacks to centrifugal pumps are however problems with the bearings and with the sealing of the rotor shaft. In this paper we present a concept for a simple, compact and cost effective solution for a blood pump with a totally magnetically suspended impeller. It is based on the new technology of the 'Bearingless Motor' and is therefore called the 'Bearingless Blood Pump.' A single bearingless slice motor is at the same time a motor and a bearing system and is able to stabilize the six degrees of freedom of the pump impeller in a very simple way. Three degrees of freedom are stabilized actively (the rotation and the radial displacement of the motor slice). The axial and the angular displacement are stabilized passively. The pump itself (without the motor-stator and the control electronics) is built very simply. It consists of two parts only: the impeller with the integrated machine rotor and the housing. So the part which gets in contact with blood and has therefore to be disposable, is cheap. Fabricated in quantities, it will cost less than $10 and will therefore be affordable for the use in a heart-lung-machine.

Barletta, Natale↗

Production of New Trabecular Bone in Osteopenic Ovariectomized Rats by Prostaglandin E2

Serum chemistry and bone morphometry of the proximal tibial metaphysis were performed in 3 month-old double fluorescent-labeled, female Sprague-Dawley rats subjected to bilateral ovariectomy or sham surgery for 4 months prior to treatment with 0, 0.3, 1,3, or 6 mg of prostaglandin E2 (PGE2)/kg/day subcutaneously for 30 days. The 4 month postovariectomized rats possessed an osteopenic proximal tibial metaphysis with 7% trabecular area compared with controls (19%). PGE2 treatment elevated osteocalcin levels and augmented proximal tibial metaphyseal bone area in ovariectomized and sham-operated rats. Osteopenic, ovariectomized rats treated with 6 mg (PGE2)/kg/day for 30 days restored bone area to levels of agematched sham-operated rats. Morphometric analyses showed increased woven and lamellar bone area, fluorescent-labeled perimeter (osteoblastic recruitment), mineral apposition rate (osteoblastic activity), bone formation rate (BFR/BV), and longitudinal bone growth. These dramatic bone changes were all significantly increased at the doseresponse manner. This study showed that in vivo PGE2 is a powerful activator of bone remodeling, it increases both bone resorption and bone formation, and produces an anabolic effect by shifting bone balance to the positive direction. Furthermore, PGE2-induced augmentation of metaphyseal bone area in ovariectomized rats was at least two times greater than in sham-operated rats.

Mori, S.↗

Light and Gravity Effects on Circadian Rhythms of Rhesus Macaques

Temporal integration of a biological organism's physiological, behavioral and biochemical systems depends upon its circadian timing system. The endogenous period of this timing system is typically synchronized to the 24- hour day by environmental cues. The daily alternation of light and dark has long been known as one of the most potent environmental synchronizers influencing the circadian timing system. Alterations in the lighting environment (length or intensity of light exposure) can also affect the homeostatic state of the organism. A series of experiments was performed using rhesus monkeys with the objective of defining the fundamental properties of the circadian rhythm of body temperature. Three major experiments were performed in addition to several preliminary studies. These experiments explored 1.) the response of the rhesus body temperature rhythm to varying day length and light intensity; 2.) the response of the body temperature rhythm to light exposure as a function of time of day; and 3.) the characteristics of the metabolic heat production rhythm which is responsible for the daily cycle in body temperature. Results of these three completed experiments will be reported here. In addition, preliminary experiments were also performed in social entrainment of rhesus circadian rhythms and the properties of rhesus body temperature rhythms in constant conditions, where no external time cues were provided. Four adult male rhesus monkeys served as subjects in all experiments. All experiments were performed at the California Regional Primate Research Center. Each animal was implanted with a biotelemetry unit that measured deep body temperature. All surgeries were performed by a board certified veterinary surgeon under sterile conditions. The biotelemetry implants also provided an index of activity level in each animal. For metabolic heat production measurements, oxygen consumption and carbon dioxide production were measured and the caloric equivalent of these was calculated. Specific methodologies are described in detail.

Fuller, Charles↗

Vascular Responsiveness in Adrenalectomized Rats with Corticosterone Replacement

To determine under resting, unstressed conditions the circulating glucocorticoid concentrations that best maintain sensitivity of the vascular smooth muscle and baroreceptor responses to vasoactive agents, rats with vascular cannulas were sham-adrenalectomized (sham) or adrenalectomized (ADRX) and provided with four levels of corticosterone replacement (-100 mg fused pellets of corticosterone: cholesterol 0, 20, 40, and 80% implanted subcutaneously at the time of adrenal surgery). Changes in vascular and baroreflex responses were determined after intravenous injection of varying doses of phenylephrine and nitroglycerin with measurement of arterial blood pressure and heart rate in the conscious, chronically cannulated rats. Vascular sensitivity was decreased, and resting arterial blood pressure tended to be decreased in the adrenalectomized rats; both were restored to normal with levels of corticosterone (40%), which also maintained body weight gain, thymus weight, and plasma corticosteroid binding globulin concentrations at normal values. The baroreflex curve generated from the sham group was different from the curves generated from the ADRX+O, 20, and 40% groups, but not different from that of the ADRX+80% group, suggesting that the baroreflex is maintained by higher levels of corticosterone than are necessary for the maintenance of the other variables. These data demonstrate that physiological levels of corticosterone (40% pellet) restore vascular responsiveness, body weight, thymus weight, and transcortin levels to normal in ADRX rats, whereas higher levels (80% pellet) are necessary for restoration of the baroreflex.

Darlington, Daniel N.↗

Fiber Pulling Apparatus

The fiber optics industry has grown into a multi-billion marketplace that will continue to grow into the 21st century. Optical fiber communications is currently dominated by silica glass technology. Successful efforts to improve upon the low loss transmission characteristics of silica fibers have propelled the technology into the forefront of the communications industry. However, reaching the theoretical transmission capability of silica fiber through improved processing has still left a few application areas in which other fiber systems can provide an influential role due to specific characteristics of high theoretical transmission in the 2 - 3 micron wavelength region. One of the other major materials used for optical fibers is the systems based upon Heavy Metal Fluoride Glass (HMFG). Commercial interest is driven primarily by the potential for low loss repeaterless infrared fibers. An example of the major communications marketplace which would benefit from the long distance repeaterless capability of infrared fibers is the submarine cables which link the continents. When considering commercial interests, optical fiber systems provide a healthy industrial position which continues to expand. Major investments in the systems used for optical fiber communications have continued to increase each year and are predicted to continue well into the next century. Estimates of 8.5% compounded annually are predicted through 1999 for the North American market and 1 1 % worldwide. The growth for the optical fiber cable itself is expected to continue between 44 and 50 per cent of the optical fiber communications budget through 1999. The total budget in 1999 world-wide is expected to be in the neighborhood of $9 billion. Another survey predicts that long haul telecommunications represents 15% of a world-wide fiber optics market in 1998. The actual amount allotted to cable was not specified. However, another market research had predicted that the cable costs alone represents more than 50% of the total budget each year through 1998. A newly emerging activity is the commercial development of doped optical fibers which can be pumped by laser diodes to provide amplification of the communication signals. This technology is newly emerging and will be developed for commercial interests in the United States by Galileo Electro-optical Incorporated in Sturbridge, MA on a license from British Telecom. Long repeaterless communication links provide the biggest stimulus for this technology. As an example of the of the revenues involved in the optical fiber communications 3 industry, the current trade journal lists that for the fiscal years, 1991 - 1994, 185 separate undersea links were established. In addition, another 105 links are planned through 1998. The distribution of revenues involved in the undersea installations is roughly $8.5 billion through 1993 and another $13 billion planned through 1998. A large portion of the future activity (34%) is planned for Southeast Asia and the Pacific Region. Other examples of the commercial utility of optical fiber networks is given in a recent scientific symposium in which the outlook for HMFG infrared fiber was determined to be very bright.Another area of interest lies in the use of fiber optics for laser surgery delivery systems.

Workman, Gary L.↗

Potentiation of Hormonal Responses to Hemorrhage and Fasting, but not Hypoglycemia in Conscious Adrenalectomized Rats

Bilateral adrenalectomy (ADRX) in rats removes the source of two major stress-responsive hormones, corticosterone and epinephrine. To test how ADRX rats with-stand stress, we performed the following experiments in adult male rats provided with indwelling femoral arterial and venous cannulae and either ADRX or sham-adrenalectomized (Sham) 3 days later and given 0.5% NaCl to drink. Five to 6 days after adrenal surgery the rats were studied after either a 15 ml/kg.5 min hemorrhage or after an overnight fast followed by insulin-induced hypoglycemia. In fed unstressed ADRX rats, basal mean arterial blood pressure was slightly decreased; heart rate was increased; blood volume, vasopressin, and oxytocin concentrations were not different from sham values; and renin and norepinephrine were significantly elevated. The recovery of arterial pressure after hemorrhage in the ADRX rats was similar to that in the sham group over a 5-h period; however, the responses of vasopressin and oxytocin were significantly greater, and those of renin and norepinephrine were markedly potentiated in the ADRX group. Heart rate recovered faster in the ADRX group and was elevated, compared to the sham value, for most of the 5-h period. Restitution of blood volume was attenuated in the ADRX group, although the restitution of plasma protein was not different between the groups. A significant difference in the change in plasma osmolality between groups after hemorrhage may account for the attenuated restitution of blood volume. After an overnight fast, which reduced blood volume in both groups of rats, the plasma renin concentration rose still further in ADRX rats; the differences in other measured variables observed between fed ADRX and sham groups remained the same. The insulin-induced 50% decrease in glucose caused minor effects on arterial blood pressure and heart rate and occasioned responses in renin and norepinephrine of similar magnitudes in the two groups. We conclude that in the absence of the adrenals, rats restore arterial pressure after hemorrhage remarkably well through potentiation of the responses of other vasoactive neural and hormonal systems. In these studies the marked potentiation of the renin response suggests that the renin-angiotensin system may be important in the maintenance of arterial blood pressure after reductions in blood volume.

Darlington, Daniel N.↗

Exercise Countermeasures for Bone Loss During Space Flight: A Method for the Study of Ground Reaction Forces and their Implications for Bone Strain

Effective countermeasures to prevent loss of bone mineral during long duration space flight remain elusive. Despite an exercise program on MIR flights, the data from LeBlanc et al. (1996) indicated that there was still a mean rate of loss of bone mineral density in the proximal femur of 1.58% per month (n=18, flight duration 4 - 14.4 months). The specific mechanisms regulating bone mass are not known, but most investigators agree that bone maintenance is largely dependent upon mechanical demand and the resultant local bone strains. A plausible hypothesis is that bone loss during space flight, such as that reported by LeBlanc et al. (1996), may result from failure to effectively load the skeleton in order to generate localized bone strains of sufficient magnitude to prevent disuse osteoporosis. A variety of methods have been proposed to simulate locomotor exercise in reduced gravity. In such simulations, and in an actual microgravity environment, a gravity replacement load (GRL) must always be added to return the exercising subject to the support surface and the resulting skeletal load is critically dependent upon the magnitude of the GRL. To our knowledge, GRLs during orbital flight have only been measured once (on STS 81) and it is likely that most or all prior treadmill exercise in space has used GRLs that were less than one body weight. McCrory (1997) has shown that subjects walking and running in simulated zero-G can tolerate GRLs of 1 if an appropriate harness is used. Several investigators have attempted to measure in vivo strains and forces in the bones of humans, but have faced ethical and technical limitations. The anteromedial aspect of the tibial midshaft has been a common site for the placement of strain gauges; one reason to measure strains in the anterior tibia is that this region is surgically accessible. Aamodt et al. (1997) were able to measure strains on the lateral surface of the proximal femur only because their experimental subjects were already scheduled for hip surgery. Lu et al. (1997) used an instrumented massive proximal femoral prosthesis along with electromyographic measurements to demonstrate that femoral forces depend on muscular activity. These analyses of in vivo bone mechanics are valuable. The invasive nature of the procedures involved, however, limits both the number of subjects and the number of strain gauge locations. Further, the results of these studies may be confounded by the inclusion of subjects with pathological conditions. Gross et al. (1992) measured strain at three locations on the equine third metacarpal and used those data to construct a computer model of the internal strain environment of the bone. An analogous placement of multiple gauges in living humans would be difficult and potentially hazardous because of the depth of soft tissue overlying the tibia and femur.

Peterman, M.↗

Neurovestibular Session Summary

Oman - The early mission operational problems caused by space motion sickness have been largely resolved in recent years. This has been achieved by appropriate timeline adjustments, voluntary head movement restriction, and judicious use of promethazine. Crew members now simply accept that some symptoms "come with the job," and usually last only a few days. But as more people have flown longer flights, we've seen cases of space sickness and inversion illusion that take several weeks to resolve. Visual reorientation illusions continue throughout long flights, and occasionally cause difficulties. EVA astronauts sometimes suddenly fear they will fall out of the payload bay or off of the RMS or Strella arms. Orientation and navigation in three dimensions in the MIR station reportedly does not come naturally, because modules have different visual verticals. It is clear that the neurovestibular problems of spaceflight have not disappeared. After return to Earth, many crew members are disoriented and ataxic in the first hour after return, and require assistance leaving the vehicle, Flight surgeons say that the longer the mission, the stronger the aftereffects, certain of which last for weeks. We do not yet know how to predict who will be afflicted. Looking ahead to 3-4 month long voyages to Mars, it seems obvious that if cruise is in O-G, the crew may encounter neurovestibular problems on arrival. Artificial G may be broadly effective as a countermeasure for many of the physiological changes of spaceflight, but from the neurovestibular perspective, it is a double-edged sword. We know that the Coriolis stimulus resulting from rotation is potentially disorienting and nauseogenic. But we don't yet know how much artificial G will be enough, nor how successfully people can adapt to a specific angular velocity and hypo G level. Development of countermeasures remains a big challenge for our neurovestibular community. Maintaining an interdisciplinary perspective is important. Three examples were presented at this meeting: 1) Transgenic animal experiments suggest that in addition to the light illumination cycle, vestibular inputs may also serve as an important input to the circadian system. 2) Radiation can cause important CNS effects in animals, including loss of spatial memory. 3) As described in our session, otolith inputs may contribute to cardiovascular regulation of orthostatic tolerance. Over the past three days, we've all enjoyed catching up with old friends, and making many new ones. On behalf of my colleagues, I want to thank Al Coats and the USRA DSLS staff for the great job they did in running this meeting. And keeping the emphasis on fun. And also my Co- Chair, Mal Cohen, who had more stamina than many of us, despite major surgery only three weeks ago. Mal and I have written a few lines describing each of the seventeen papers in our session, to give you a quick over-view, and as a guide to the full abstracts, We have grouped them under five themes: preflight and inflight countermeasurements, postlanding posture and locomotion deficits: assessment and prediction, adaptive processes, relationships among physical simuli, perceptions, and eye movements, vestibular contribution to human autonomic responses, and implications and recommendations.

Oman, Charles↗

Evaluation of Manganese Doped Ca5(PO4)3F as a Near Infrared (1-2 microns) Solid-State Laser Material

Tunable solid-state lasers are of enormous interest for applications including fundamental spectroscopy, remote sensing of the earth atmosphere, medical surgery, and optical communications. Efficient and widely tunable lasers have been developed for the 800-1100 nm region based on transition metal doped insulators like e.g. Ti:Sapphire. The development of transition metal lasers operating at longer wavelength, however, has been limited by the luminescence efficiency of existing materials. We are currently evaluating Mn doped Ca5(PO4)3F as a new solid-state laser material for the 1-2 micro-m region. Preliminary spectroscopic studies revealed that Mn:Ca5(PO4)3F exhibits an intense near infrared luminescence which extends from 1100-1300 nm. Based on lifetime measurements we estimated the luminescence quantum efficiency to be as high as 90 deg./0 at room temperature. The near infrared luminescence properties of Mn doped Ca5(PO4)3F and its potential for solid-state laser applications will be discussed in detail.

Turner, Matthew↗

Otolith and Vertical Canal Contributions to Dynamic Postural Control

The objective of this project is to determine: 1) how do normal subjects adjust postural movements in response to changing or altered otolith input, for example, due to aging? and 2) how do patients adapt postural control after altered unilateral or bilateral vestibular sensory inputs such as ablative inner ear surgery or ototoxicity, respectively? The following hypotheses are under investigation: 1) selective alteration of otolith input or abnormalities of otolith receptor function will result in distinctive spatial, frequency, and temporal patterns of head movements and body postural sway dynamics. 2) subjects with reduced, altered, or absent vertical semicircular canal receptor sensitivity but normal otolith receptor function or vice versa, should show predictable alterations of body and head movement strategies essential for the control of postural sway and movement. The effect of altered postural movement control upon compensation and/or adaptation will be determined. These experiments provide data for the development of computational models of postural control in normals, vestibular deficient subjects and normal humans exposed to unusual force environments, including orbital space flight.

Black, F. Owen↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside the orifices of the body. This limits their use to the larger natural orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example, can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (less than or equal to 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. This work describes an approach for recovering images from tightly confined spaces using multimode. The concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront, which was predistorted with the characteristics of the fiber. The approach described here also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually inaccessible).

Jackson, Deborah↗

Multimode-Optical-Fiber Imaging Probe

Currently, endoscopic surgery uses single-mode fiber-bundles to obtain in vivo image information inside orifices of the body. This limits their use to the larger natural bodily orifices and to surgical procedures where there is plenty of room for manipulation. The knee joint, for example can be easily viewed with a fiber optic viewer, but joints in the finger cannot. However, there are a host of smaller orifices where fiber endoscopy would play an important role if a cost effective fiber probe were developed with small enough dimensions (< 250 microns). Examples of beneficiaries of micro-endoscopes are the treatment of the Eustatian tube of the middle ear, the breast ducts, tear ducts, coronary arteries, fallopian tubes, as well as the treatment of salivary duct parotid disease, and the neuro endoscopy of the ventricles and spinal canal. To solve this problem, this work describes an approach for recovering images from. tightly confined spaces using multimode fibers and analytically demonstrates that the concept is sound. The proof of concept draws upon earlier works that concentrated on image recovery after two-way transmission through a multimode fiber as well as work that demonstrated the recovery of images after one-way transmission through a multimode fiber. Both relied on generating a phase conjugated wavefront which was predistorted with the characteristics of the fiber. The described approach also relies on generating a phase conjugated wavefront, but utilizes two fibers to capture the image at some intermediate point (accessible by the fibers, but which is otherwise visually unaccessible).

Jackson, Deborah↗