Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Preliminary Deposition Modeling: For Determining the Deposition of Corrosive Contaminants on SNF Canisters

This report fulfills the M3 milestone M3SF-20PN010207045. During fiscal year (FY) 2019, Pacific Northwest National Laboratory (PNNL) worked to develop initial deposition and particle tracking models which could be used to better understand how corrosive contaminants deposit on the surfaces of spent nuclear fuel (SNF) canisters during dry storage. These models may be useful in understanding the likelihood of chloride induced stress corrosion cracking (CISCC) on SNF canisters

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Phased Construction Completion Report for Decontamination Laundry Demolition at the Oak Ridge National Laboratory

This Phased Construction Completion Report (PCCR) documents completion of demolition, waste disposition, and slab stabilization activities of Building 2523 (Decontamination Laundry) for the Oak Ridge National Laboratory (ORNL). The Decontamination Laundry is located directly north of the intersection of White Oak Avenue and the 2519 Access Road. This demolition scope included the removal of the above-grade structures and facility components associated with Building 2523. This scope included the removal of Building 2523 (and all remaining contents inside), Trailer 2523A (and all remaining contents inside), an above-grade wastewater tank, and a wooden access porch connecting Buildings 2523 and Trailer 2523A. On the north side of Building 2523, above-grade portions of selected remaining foundations/stairs were removed from former Building 2517 to make room to stage waste containers. Building 2621 is west of the Laundry Building and Buildings 2547 and 2649 are to the east, while Building 2525 is to the north. Building 2523 is located within Bethel Valley Exposure Unit (EU) 3. The total area of the EU is approximately 39 acres. The area within EU 3 is bounded by First Street on the west, Central Avenue on the north, Third Street on the east and south. The slab of Building 2523 has been stabilized with a cap of flowable fill concrete and asphalt to contain residual radiological contamination and to provide surface suitable for vehicle parking. No below-grade demolition actions were performed during this task.

99 GENERAL AND MISCELLANEOUS↗

Closure Report for Corrective Action Unit 116: Area 25 Test Cell C Facility, Nevada National Security Site, Nevada with ROTC-1

CR loaded to this OSTI record. Just adding new file which includes CR plus new ROTC 1 and update the metadata to the following: This Closure Report (CR) presents information supporting closure of Corrective Action Unit (CAU) 116, Area 25 Test Cell C Facility. This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; the U.S. Department of Energy (DOE), Environmental Management; the U.S. Department of Defense; and DOE, Legacy Management (FFACO, 1996 [as amended March 2010]). CAU 116 consists of the following two Corrective Action Sites (CASs), located in Area 25 of the Nevada National Security Site: (1) CAS 25-23-20, Nuclear Furnace Piping and (2) CAS 25-41-05, Test Cell C Facility. CAS 25-41-05 consisted of Building 3210 and the attached concrete shield wall. CAS 25-23-20 consisted of the nuclear furnace piping and tanks. Closure activities began in January 2007 and were completed in August 2011. Activities were conducted according to Revision 1 of the Streamlined Approach for Environmental Restoration Plan for CAU 116 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2008). This CR provides documentation supporting the completed corrective actions and provides data confirming that closure objectives for CAU 116 were met. Site characterization data and process knowledge indicated that surface areas were radiologically contaminated above release limits and that regulated and/or hazardous wastes were present in the facility. The Record of Technical Change 1 updated the use restriction information.

54 ENVIRONMENTAL SCIENCES↗

Emulsified Oil Bio-Barrier to Remediate CEE in the Distal Portion of a Groundwater Plume - 20210

A non-time critical (NTC) removal action (RA) was designed at the Savannah River Site (SRS) to inject an emulsified oil mixture with a bioaugmentation culture to prevent trichloroethylene (TCE) discharging to surface water above maximum contaminant levels (MCLs). The emulsified oil mixture is expected to sequester the TCE and then be broken down into harmless compounds through microbial biodegradation. At 15 locations 8,290 L (2,190 gal) of oil mixture, buffer and chase water were injected into the subsurface creating two bio-barriers. At each location half of the oil mixture was injected, then 2 L (0.528 gal) of an enriched bioaugmentation culture was injected, and then the second half of the oil mixture was injected into the subsurface. Finally, at each location 151 L (40 gal) of buffer mixed with 575 L (200 gal) of dilution water was then injected followed by 1,135 L (300 gal) of chase water. SRS estimates this created two emulsified oil barriers totaling 73 m (240 ft) long, approximately 3 m (10 ft) high and 4.9 m (16 ft) wide in the subsurface. Similar emulsified oil barriers have been effective for 3 to 5 years, and SRS anticipates a similar longevity for these barriers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cation Exchange Capacity, Anion Exchange Capacity, and Mineralogy of F-Area Aquifer Sediments

Strontium-90 (Sr-90) is a contaminant of concern in groundwater and surface water at both F-Area and H-Area Seepage Basins. This contaminant was disposed of, along with other heavy metals and radionuclides, into a series of unlined seepage basins from 1955 until 1988. The acidity of the wastewater increased Sr-90 mobility from the basin soil through the vadose zone and into the Upper Aquifer Zone (UAZ), creating a groundwater plume that discharges into wetlands areas and a local stream called Fourmile Branch.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Functionalized Magnetic Nanoparticles for Technetium Sequestration from Groundwater

Technetium 99 (Tc) is among the most common environmental contaminants at DOE sites and one of the most common risk drivers in low- and high-level waste disposal sites. The majority of Tc is generated from anthropogenic sources, such as nuclear power plants, global weapons, nuclear storage facilities and medical applications. Through these sources, Tc contamination has been unintentionally introduced in to the environment. The most common chemical form of Tc is Tc(VII)O{sub 4}{sup -}. Due to its high solubility and mobility, Tc can enter the food chain and cause adverse health effects to humans. Currently, ion exchange resins and reduction processes are the most common approaches for Tc immobilization. Although these techniques have shown to be effective, they also possess major drawbacks, such as high cost, low adsorption capacity, and complex creation and maintenance. Therefore, development of more efficient and simple technologies for the remediation of Tc-contaminated systems are needed. Functionalized magnetic nanoparticles have been used to remove organic and inorganic contaminants from water resources. These nanoparticles have attracted extensive attention as an adsorbent material due to their large surface area, high efficiency, low-cost, easy functionalization and separation with a magnet. This study seek to develop functionalized magnetic iron oxide nanoparticles for the efficient removal of Tc and other heavy metal contaminants from water resources under ambient conditions. Objectives: Synthesize magnetic iron oxide nanoparticles and functionalize their surface with Cetyltrimethylammonium Bromide (CTAB) and tetraethyl-orthosilicate (TEOS). Characterize the synthesized nanoparticles using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDS), Dynamic Light Scattering (DLS) and Zeta PALS. Perform adsorption studies to evaluate their adsorption behavior and capacity for (a) Technetium using Rhenium (ReO{sub 4}{sup -}) as a surrogate and (b) heavy metals, e.g. Cu{sup 2+}. Conclusions: Magnetic iron oxide nanoparticles were successfully functionalized with CTAB and TEOS. The functionalization of the iron oxide nanoparticles affects their surface charge and their hydrodynamic diameter. The addition of CTAB or TEOS decreased the hydrodynamic diameter of the nanoparticles due to repulsive and steric forces. The SEM micrographs show spherical nanoparticles of different sizes. The EDX analysis shows the presence of iron and oxygen from the iron oxide crystalline structure, and the different constituents of the CTAB and TEOS molecules. Proof-of-concept shows the successful adsorption of rhenium (ReO{sub 4}{sup -}) and copper Cu{sup 2+}) onto CTAB-Fe{sub 2}O{sub 3} and TEOS-Fe{sub 2}O{sub 3} respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Remediation Options for a Perched-Water Unit at the Hanford Site - 20378

At the U.S. Department of Energy's Hanford Site, liquid-phase waste was discharged using surface disposal features such as ponds, trenches, and cribs. These practices distributed contaminants in the subsurface, some of which are currently in the vadose zone above the groundwater. At the 200-DV-1 operable unit (OU) at the Hanford Site, a key feature is a perched-water zone. This perched-water zone contains several million liters of water contaminated with high concentrations of uranium, technetium-99 (Tc-99), and nitrate that serves as a continuing source of contamination to the underlying aquifer. Currently, a pumping system is used to remove contaminant mass from the perched-water zone. However, water extraction will become more challenging as the perched unit dewaters. As a result, residual contaminants remaining after pumping is no longer effective needs to be addressed with post-extraction mitigation approaches, appropriate monitoring, and selection of suitable remediation endpoints. Thus, a remedy evaluation needs to include the unique conditions of this perched-water zone. As part of the initial evaluation, a set of technologies have been preliminarily identified as potentially applicable to the perched-water zone, including in situ remediation technologies to sequester uranium and Tc-99 and to degrade nitrate. While there is sufficient information available for direct consideration of some of the reviewed technologies in a feasibility study, five in situ remediation technologies were identified as needing additional information on their effectiveness under the geochemical and contaminant conditions of the perched-water zone. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alteration of the Cesium-137 soil profile by wild boar rooting after the Fukushima Daiichi Nuclear Power Plant accident

Large amounts of Cesium-137 ( 137 Cs, physical half-life ca. 30 years) were released into the environment from the 2011 Fukushima Daiichi Nuclear Power Plant (FDNPP) accident in Japan. Initially contaminants from the accident were deposited on the surface soil layers in terrestrial ecosystems, but over time vertical migration of 137 Cs has occurred, with most 137 Cs now distributed a few centimeters below the soil surface. Wild boar (Sus scrofa) rooting likely alters the distribution of contaminants in soil profiles. Such impacts may be particularly pronounced in areas contaminated from the FDNPP accident, given the increase in abundance of wild boar in these areas. Our objective was to determine whether rooting by wild boar alters the distribution of 137 Cs contamination within soil profiles through collection of soil cores from control sites and two different types of rooting samples, “new depressions” and “old depressions” within the difficult-to-return zone surrounding the FDNPP. The 137 Cs ratio [activity concentration of 137 Cs at each depth / the maximum activity concentration of 137 Cs in each core sample] rapidly decreased after reaching a peak at the control sites. However, the 137 Cs ratio at all rooted sites decreased more slowly, and 137 Cs was distributed deeper into the soil layers than control sites, across both new and old rooting sites. Moreover, the 137 Cs soil profiles varied greatly among core samples and sampling sites. Furthermore, these results demonstrate that soil disturbance from wild boar rooting can directly influence the distribution of contaminants within soil profiles. However, the extent to which deeper layers are affected by contamination depends on the unique characteristics (i.e., depth of rooting) of each wild boar rooting disturbance. Further studies are needed to examine the effects of long-term rooting on the alteration of 137 Cs in soil profiles.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Multidecadal Biological Monitoring and Abatement Program assessing human impacts on aquatic ecosystems within the Oak Ridge Reservation in eastern Tennessee, USA

Human activities can be powerful drivers of ecosystem change within catchments. While most long-term catchment studies have been conducted at pristine sites, such studies are less common from sites more impacted by human activity. The Oak Ridge National Laboratory's Biological Monitoring and Abatement Program (BMAP) was developed in the mid-1980s to (1) assess compliance with environmental regulations, (2) identify causes of adverse ecological impacts, (3) provide data for human and ecological risk assessments, and (4) evaluate the effectiveness of remedial actions taken to mitigate the impacts of contaminants in soils, groundwater, and surface water by documenting ecological recovery on the Oak Ridge Reservation (ORR), a federally owned 33,476-acre site in eastern Tennessee, USA, managed by the U.S. Department of Energy. The ORR is composed of multiple watersheds containing many small to mid-size streams. BMAP uses an integrated approach for determining stream health; its databases include long-term seasonal records of contaminant concentrations in water and biota, data from aquatic toxicity testing, and surveys of macroinvertebrate and fish assemblages from impacted and reference streams. These long-term data provide valuable records of degradation and recovery in catchment ecosystems. Our objective in this work is to describe our study system and data series in order to increase awareness of the availability of these long-term data to the catchment science community.

54 ENVIRONMENTAL SCIENCES↗

Algebraic expressions for estimating the impact depths of a surface barrier over a homogeneous soil

Engineered surface barriers are used to isolate subsurface contaminants for effective long-term containment of municipal solid waste, other nonhazardous solid and liquid waste, hazardous and toxic wastes, and radioactive waste. The impact depths of a surface barrier are affected by the pre-barrier recharge rate and the properties of the soil beneath the barrier. In this paper, the pore-size-specific (PSS) water velocity is defined and an algebraic expression of PSS velocity is derived based on the stream tube concept and the Brooks and Corey hydraulic retention model. Algebraic expressions are developed to estimate drainage velocities and barrier impact depths after the emplacement of a surface barrier. Four impact depth terms are used to convey the protective effect: drainage front, average drainage, the location with 50% impact, and drainage tail. The drainage front depth is the deepest point at which the barrier has a detectable impact at a specific time (also called the near zero-impact depth). The average-impact depth is the depth at which average drainage occurs. At the 50% impact depth, the water flux rate is reduced by half because of the surface barrier. Lastly, the drainage tail depth (also called the full-impact depth) is the deepest depth at which the water conditions above it are in equilibrium with the barrier. The algebraic expressions show that the average-impact depth is no more than 1/3 of near zero-impact depth, while the 50% impact depth is slightly larger than 1/2 of the near zero-impact depth. The full-impact depth, depending on the final recharge rate from the surface barrier, is usually much smaller than the other impact depths. These differences lead to a very large transition zone beneath a surface barrier. Numerical simulations were conducted to replicate the same conditions. The numerical results corroborated the analytical models by predicting very similar water content profiles and near zero-, average-, 50%, and full-impact depths. The algebraic expressions provided in this paper are useful for quickly identifying sites where the depth of the existing contaminants could be beyond the protection of a surface barrier.

54 ENVIRONMENTAL SCIENCES↗

Surface Regulating of a Double–Perovskite Electrode for Protonic Ceramic Fuel Cells to Enhance Oxygen Reduction Activity and Contaminants Poisoning Tolerance

Protonic ceramic fuel cells (PCFCs) are one of the most efficient energy conversion devices. However, the performance of current PCFCs is greatly limited by the sluggish oxygen reduction reaction (ORR) kinetics and the fast degradation of cathode due to contaminants poisoning (such as Cr species and steam). In this work, we report a surface regulating of a double perovskite PrBa 0.5 Sr 0.5 Co 1.5 Fe 0.5 O 5+δ (PBSCF) cathode by a Pr 0.9 Fe 0.7 Co 0.3 O 3 (PFC) catalyst coating to enhance the ORR activity and stability. When tested in direct contact with Cr in the air with 3% H 2 O at 650 °C, the polarization resistance (Rp) of the PFC-PBSCF electrode increases from $\approx$0.39 to 0.45 Ω cm 2 after 100 h operation; in contrast, the R p of a PBSCF electrode increases from 0.63 to 0.82 Ω cm 2 . Further, a PCFC with the PFC-PBSCF cathode demonstrates an excellent peak power density ($\approx$1.08 W cm -2 at 650 °C) and significantly enhanced durability (degradation rate of 0.03 % h -1 ), much better than those of the cells with a PBSCF cathode ($\approx$0.75 W cm -2 and degradation rate of 0.12 % h -1 ). Raman spectroscopy and density functional theory calculations indicate that the PFC catalyst coating diminishes the formation of Cr species, such as (Ba 1-x Sr x )CrO 4 , on the cathode surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular speciation controls arsenic and lead bioaccessibility in fugitive dusts from sulfidic mine tailings

Communities nearby mine wastes in arid and semi-arid regions are potentially exposed to high concentrations of toxic metal(loid)s from fugitive dusts deriving from impoundments. To assess the relation between potentially lofted particles and human health risk, we studied the relationship between pharmacokinetic bioaccessibility and metal(loid) molecular speciation for mine tailings dust particulate matter (PM), with elevated levels of arsenic and lead (up to 59 and 34 mmol kg -1 , respectively), by coupling in vitro bioassay (IVBA) with X-ray absorption spectroscopy (XAS). Mine tailing efflorescent salts (PM ES ) and PM from the surface crust (0–1 cm, PM SC ) and near surface (0–25 cm) were isolated to <10 μm and <150 μm effective spherical diameter (PM 10 and PM 150 ) and reacted with synthetic gastric and lung fluid for 30 s to 100 h to investigate toxic metal(loid) release kinetics. Bioaccessible (BAc) fractions of arsenic and lead were about 10 and 100 times greater in gastric than in lung fluid simulant, respectively, and 10–100% of the maximum gastric BAc from PM 10 and PM 150 occurred within 30 s, with parabolic dissolution of fine, highly-reactive particles followed by slower release from less soluble sources. Evaporite salts were almost completely solubilized in gastric-fluid simulants. Arsenate within jarosite and sorbed to ferrihydrite, and lead from anglesite, were identified by XAS as the principal contaminant sources in the near surface tailings. In the synthetic lung fluid, arsenic was released continuously to 100 h, suggesting that residence time in vivo must be considered for risk determination. Analysis of pre- and post-IVBA PM indicated the release of arsenic in lung fluid was principally from arsenic-substituted jarosite, whereas in synthetic gastric fluid arsenic complexed on ferrihydrite surfaces was preferentially released and subsequently repartitioned to jarosite-like coordination at extended exposures. Lead dissolved at 30 s was subsequently repartitioned back to the solid phase as pyromorphite in phosphate rich lung fluid. The bioaccessibility of lead in surface tailings PM was limited due to robust sequestration in plumbojarosite. Kinetic release of toxic elements in both synthetic biofluids indicated that a single IVBA interval may not adequately describe release dynamics.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Analysis of Salmonella enterica Isolated from a Mixed-Use Watershed in Georgia, USA: Antimicrobial Resistance, Serotype Diversity, and Genetic Relatedness to Human Isolates

As the cases of Salmonella enterica infections associated with contaminated water are increasing, this study was conducted to address the role of surface water as a reservoir of S. enterica serotypes. We sampled rivers and streams (n = 688) over a 3-year period (2015 to 2017) in a mixed-use watershed in Georgia, USA, and 70.2% of the total stream samples tested positive for Salmonella. A total of 1,190 isolates were recovered and characterized by serotyping, antimicrobial susceptibility testing, and pulsed-field gel electrophoresis (PFGE). A wide range of serotypes was identified, including those commonly associated with humans and animals, with S. enterica serotype Muenchen being predominant (22.7%) and each serotype exhibiting a high degree of strain diversity by PFGE. About half (46.1%) of the isolates had PFGE patterns indistinguishable from those of human clinical isolates in the CDC PulseNet database. A total of 52 isolates (4.4%) were resistant to antimicrobials, out of which 43 isolates were multidrug resistant (MDR; resistance to two or more classes of antimicrobials). These 52 resistant Salmonella isolates were screened for the presence of antimicrobial resistance genes, plasmid replicons, and class 1 integrons, out of which four representative MDR isolates were selected for whole-genome sequencing analysis. The results showed that 28 MDR isolates resistant to 10 antimicrobials had blacmy-2 on an A/C plasmid. Persistent contamination of surface water with a high diversity of Salmonella strains, some of which are drug resistant and genetically indistinguishable from human isolates, supports a role of environmental surface water as a reservoir for and transmission route of this pathogen.

59 BASIC BIOLOGICAL SCIENCES↗

Variation in Cation Adsorption Mechanism Controlled by Chemical and Structural Heterogeneities at the Quartz (101)–Water Interface

Mineral–water interfacial reactions are central to chemical processes that control the fate of nutrients and contaminants in natural environments. Mineral surfaces commonly have complex structures and compositions whose impact on interfacial reactivity is poorly understood. Here, in this work, we investigated the effects of surface heterogeneities on Rb + sorption at the quartz (101)–10 mM RbCl solution interface at pH 9.8 using in situ high-resolution X-ray reflectivity. Two surface locales (i.e., Spots A and B) having distinct interfacial structures were chosen: Spot A was characterized by its low defect density (≤20% topmost Si vacancies) and Rb + adsorption occurred predominantly as an inner-sphere complex. In comparison, Spot B had a higher defect density (~50% vacancies) and was covered with poorly crystalline SiO 2 . A substantially larger Rb + uptake (i.e., 7-times higher coverage) was observed on this defective surface where Rb + incorporated in the vacancy sites (confirmed by density functional tight binding-based molecular dynamics simulations) or adsorbed directly on the disordered film. These results provide a direct quantification of how surface heterogeneity influences the geochemical behavior of mineral–water interfaces, in particular highlighting the important role of chemical and structural defects on the sorbate speciation and coverage at silicate mineral surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct-bonded diamond membranes for heterogeneous quantum and electronic technologies

Diamond has superlative material properties for a broad range of quantum and electronic technologies. However, heteroepitaxial growth of single crystal diamond remains limited, impeding integration and evolution of diamond-based technologies. Here, we directly bond single-crystal diamond membranes to a wide variety of materials including silicon, fused silica, sapphire, thermal oxide, and lithium niobate. Our bonding process combines customized membrane synthesis, transfer, and dry surface functionalization, allowing for minimal contamination while providing pathways for near unity yield and scalability. We generate bonded crystalline membranes with thickness as low as 10 nm, sub-nm interfacial regions, and nanometer-scale thickness variability over 200 by 200 μm 2 areas. We measure spin coherence times T 2 for nitrogen vacancy centers in 150 nm-thick bonded membranes of up to 623 ± 21 μs, suitable for advanced quantum applications. We demonstrate multiple methods for integrating high quality factor nanophotonic cavities with the diamond heterostructures, highlighting the platform versatility in quantum photonic applications. Furthermore, we show that our ultra-thin diamond membranes are compatible with total internal reflection fluorescence (TIRF) microscopy, which enables interfacing coherent diamond quantum sensors with living cells while rejecting unwanted background luminescence. The processes demonstrated herein provide a full toolkit to synthesize heterogeneous diamond-based hybrid systems for quantum and electronic technologies.

color center↗

Analysis and design of fast flow liquid Li divertor for fusion nuclear science facility (FNSF) using coupled plasma boundary and LM MHD/heat transfer codes *

The SOLPS-ITER code is utilized to analyze the boundary plasma associated with a fast-flow lithium (Li) divertor configuration in the fusion nuclear science facility (FNSF) tokamak and identify operational regimes with acceptable divertor and core conditions. Plasma transport from the SOLPS-ITER code has been coupled with a liquid metal (LM) MHD/heat transfer code to model a Li open-surface divertor design and assess its impact on the scrape-off-layer (SOL) and core plasma performance. Simulations with only Neon (Ne) impurity seeding have been conducted to evaluate its impact on meeting FNSF design demands for the divertor and upstream plasma parameters. Simulation results indicate that Ne seeding significantly mitigates divertor heat flux but potentially reduces both upstream electron and main ion density due to fuel dilution. The combined application of Ne seeding and deuterium (D 2 ) puffing is required to satisfy the FNSF design requirements on upstream density ($n^{OMP}_{e,sep}$~1× 10 20 m -3 ) and divertor energy flux ($q^{Odiv}_{\bot,max}$<10 MW m -2 ). D 2 puffing plays a role in counteracting upstream density drops and augmenting energy and momentum losses through atomic and molecular processes. The inlet Li flow velocity is systematically varied across a wide range to identify acceptable flows and corresponding LM surface temperatures. This comprehensive analysis identifies the acceptable Li flow parameters, LM surface temperature, and emitted Li fluxes necessary to meet the major design constraints. The emitted Li fluxes exhibit minimal impact on the main plasma at surface temperatures up to approximately ~525 °C, corresponding emitted Li fluxes of up to φ Li ~2X10 23 atoms s -1 . Uncertainties in the Li emission processes from the surface are also investigated, primarily influencing Li loss in the lower surface temperature range (<525 °C), with simulation results indicating a minor impact on the divertor and upstream plasma. Conversely, evaporation predominantly drives the Li loss processes at higher surface temperature ranges (>525 °C), contaminating both the divertor and upstream plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗