Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STABLE BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Production of neutron-rich Ca, Sn, and Xe isotopes in transfer-type reactions with radioactive beams

The production cross sections of neutron-rich isotopes {sup 52,54,56,58,60}Ca, {sup 136,138,140,142}Sn, and {sup 146,148,150,152}Xe are predicted for future experiments in the diffusive multinucleon transfer reactions {sup 86,90,92,94}Kr, {sup 124,130,132,134}Sn, {sup 136,140,142,146}Xe, and {sup 138,144,146}Ba+{sup 48}Ca with stable and radioactive beams at incident energies close to the Coulomb barrier. Because of the small cross sections, the production of neutron-rich isotopes requires the optimal choice of projectile-target combinations and bombarding energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Charge Breeding of Radioactive Isotopes at the CARIBU Facility

An Electron Beam Ion Source Charge Breeder (EBIS-CB) has been developed at Argonne National Laboratory as part of the californium rare ion breeder upgrade. For the past year, the EBIS-CB has been undergoing commissioning as part of the ATLAS accelerator complex. It has delivered both stable and radioactive beams with A/Q < 6, breeding times < 30 ms, low background contamination, and charge breeding efficiencies > 18% into a single charge state. The operation of this device, challenges during the commissioning phase, and future improvements will be discussed. Published by AIP Publishing.

Vondrasek, Richard↗

Fast Transverse Beam Instability Caused by Electron Cloud Trapped in Combined Function Magnets

Electron cloud instabilities affect the performance of many circular high-intensity particle accelerators. They usually have a fast growth rate and might lead to an increase of the transverse emittance and beam loss. A peculiar example of such an instability is observed in the Fermilab Recycler proton storage ring. Although this instability might pose a challenge for future intensity upgrades, its nature had not been completely understood. The phenomena has been studied experimentally by comparing the dynamics of stable and unstable beam, numerically by simulating the build-up of the electron cloud and its interaction with the beam, and analytically by constructing a model of an electron cloud driven instability with the electrons trapped in combined function dipoles. Stabilization of the beam by a clearing bunch reveals that the instability is caused by the electron cloud, trapped in beam optics magnets. Measurements of microwave propagation confirm the presence of the cloud in the combined function dipoles. Numerical simulations show that up to 10$^{-2}$ of the particles can be trapped by their magnetic field. Since the process of electron cloud build-up is exponential, once trapped this amount of electrons significantly increases the density of the cloud on the next revolution. In a combined function dipole this multi-turn accumulation allows the electron cloud reaching final intensities orders of magnitude greater than in a pure dipole. The estimated fast instability growth rate of about 30 revolutions and low mode frequency of 0.4 MHz are consistent with experimental observations and agree with the simulations. The created instability model allows investigating the beam stability for the future intensity upgrades.

43 PARTICLE ACCELERATORS↗

Status and characterization of the lithium beam diagnostic on DIII-D

The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I= 15−20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt= 1−10 ms and the radial resolution of ΔR= 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

43 PARTICLE ACCELERATORS↗

Analysis of Coupled Bunch Instabilities in the NSLS-II Storage Ring with a 7-cell PETRA-III RF Structure

We studied the coupled-bunch instability driven by a 7-cell PETRA-III cavity structure, which is considered to be installed in the commissioning Phase 1 in the NSLS-II storage ring at an average current of 25mA. For instability threshold calculations we used the parameters of the bare lattice (no DW’s and Landau cavities). The transverse and longitudinal coupled-bunch instabilities can be driven by the higher order modes (HOM’s) of the 7-cell PETRA-III cavity structure. In the case of uniform filling the beam is longitudinally stable, and transversely unstable at zero chromaticity. To increase the transverse instability threshold we studied the stabilizing effect of the slow head-tail instability at positive chromaticity. We assume the slow head tail effect is driven by a broadband resonator impedance. In the case of all RF buckets filled (M=1320 bunches, N=3.1x10 8 particles per bunch) the beam is unstable for values of the chromaticity in the range [0 2]. To increase the damping provided by the slow head-tail effect, we discuss fillings with a larger number of particles per bunch. We analyze uniform filling configurations with M=132 (N=3.1x10 9 ) and M=66 (N=6.2x10 9 ). We also discussed HOM’s frequencies detuning based upon temperature change as a cure of the coupled-bunch instabilities, and proposed working points to make the 7-cell PETRA-III cavity structure stable under coupled-bunch interaction.

36 MATERIALS SCIENCE↗

Progress of resonant ionization laser ion source development at GANIL

SPIRAL2 (Système de Production d’Ions Radioactifs Accélérés en Ligne) is a research facility under construction at GANIL (Grand Accélérateur National d’Ions Lourds) for the production of radioactive ion beams by isotope separation on-line methods and low-energy in-flight techniques. A resonant ionization laser ion source will be one of the main techniques to produce the radioactive ion beams. GISELE (GANIL Ion Source using Electron Laser Excitation) is a test bench developed to study a fully operational laser ion source available for Day 1 operations at SPIRAL2 Phase 2. The aim of this project is to find the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results about the new ion source geometry will be presented.

43 PARTICLE ACCELERATORS↗

Development of a surface ionization source for the SPIRAL 2 project

Development of new radioactive beams, and thus of new target ion sources (TISs) for isotope-separator-on-line production systems are in progress at GANIL for the SPIRAL 2 project. The efficiency and time response measurements of each step in the production process are crucial to predict and maximize the available yields, in particular, for short lived isotopes. This paper presents a method for measuring these quantities that makes use of a stable alkali chopped beam of controlled intensity. This method was applied to surface ionization source test for high efficiency. Results of recent experiments are presented that include ionization efficiency measurements for Cs, Rb, K, Na, and Li with a graphite and rhenium ionizer and dwell time of these alkalis on graphite. The results enabled to design a first surface ionization source prototype which will be installed in the SPIRAL 2 TIS.

43 PARTICLE ACCELERATORS↗

Inductively driven surface-plasma negative ion source for N-NBI use (invited)

The long-pulse surface-plasma source prototype is developed at Budker Institute of Nuclear Physics for negative-ion based neutral beam injector use. The essential source features are (1) an active temperature control of the ion-optical system electrodes by circulation of hot thermal fluid through the channels, drilled in the electrode bodies, (2) the concaved transverse magnetic field in the extraction and acceleration gaps, preventing the electrons trapping and avalanching, and (3) the directed cesium deposition via distribution tubes adjacent to the plasma grid periphery. The long term effect of cesium was obtained just with the single cesium deposition. The high voltage strength of ion-optical system electrodes was improved with actively heated electrodes. A stable H{sup −} beam with a current ∼1 A and energy 90 keV was routinely extracted and accelerated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a hot-cavity type resonant ionization laser ion source

Resonant Ionization Laser Ion Source (RILIS) is nowadays an important technique in many Radioactive Ion Beam (RIB) facilities for its reliability and ability to ionize efficiently and element selectively. Grand Accélérateur National d’Ions Lourds (GANIL) Ion Source using Electron Laser Excitation (GISELE) is an off-line test bench for RILIS developed to study a fully operational resonant laser ion source at GANIL facility. The ion source body has been designed as a modular system to investigate different experimental approaches by varying the design parameters, to develop the future on-line laser ion source. The aim of this project is to determine the best technical solution which combines high selectivity and ionization efficiency with small ion beam emittance and stable long term operation. Latest results concerning emittance and time profile development as a function of the temperature for different ion source versions will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical substantiation of biological efficacy enhancement for β-delayed particle decay {sup 9}C beam: A Monte Carlo study in combination with analysis with the local effect model approach

Purpose: To improve the efficacy of heavy ion therapy, β-delayed particle decay {sup 9}C beam as a double irradiation source for cancer therapy has been proposed. The authors’ previous experiment showed that relative biological effectiveness (RBE) values at the depths around the Bragg peak of a {sup 9}C beam were enhanced and compared to its stable counterpart {sup 12}C beam. The purpose of this study was to explore the nature of the biological efficacy enhancement theoretically. Methods: A Monte Carlo simulation study was conducted in this study. First a simplified cell model was established so as to form a tumor tissue. Subsequently, the tumor tissue was imported into the Monte Carlo simulation software package GATE and then the tumor cells were virtually irradiated with comparable {sup 9}C and {sup 12}C beams, respectively, in the simulations. The transportation and particle deposition data of the {sup 9}C and {sup 12}C beams, derived from the GATE simulations, were analyzed with the authors’ local effect model implementation so as to deduce cell survival fractions. Results: The particles emitted from the decay process of deposited {sup 9}C particles around a cell nucleus increased the dose delivered to the nucleus and elicited clustered damages around the secondary particles’ trajectories. Therefore, compared to the {sup 12}C beam, the RBE value of the {sup 9}C beam increased at the depths around their Bragg peaks. Conclusions: Collectively, the increased local doses and clustered damages due to the decayed particles emitted from deposited {sup 9}C particles led to the RBE enhancement in contrast with the {sup 12}C beam. Thus, the enhanced RBE effect of a {sup 9}C beam for a simplified tumor model was shown theoretically in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Heavy ion linear accelerator for radiation damage studies of materials

A new eXtreme MATerial (XMAT) research facility is being proposed at Argonne National Laboratory to enable rapid in situ mesoscale bulk analysis of ion radiation damage in advanced materials and nuclear fuels. This facility combines a new heavy-ion accelerator with the existing high-energy X-ray analysis capability of the Argonne Advanced Photon Source. The heavy-ion accelerator and target complex will enable experimenters to emulate the environment of a nuclear reactor making possible the study of fission fragment damage in materials. Material scientists will be able to use the measured material parameters to validate computer simulation codes and extrapolate the response of the material in a nuclear reactor environment. Utilizing a new heavy-ion accelerator will provide the appropriate energies and intensities to study these effects with beam intensities which allow experiments to run over hours or days instead of years. The XMAT facility will use a CW heavy-ion accelerator capable of providing beams of any stable isotope with adjustable energy up to 1.2 MeV/u for 238 U 50+ and 1.7 MeV for protons. This energy is crucial to the design since it well mimics fission fragments that provide the major portion of the damage in nuclear fuels. The energy also allows damage to be created far from the surface of the material allowing bulk radiation damage effects to be investigated. Furthermore, the XMAT ion linac includes an electron cyclotron resonance ion source, a normal-conducting radio-frequency quadrupole and four normal-conducting multi-gap quarter-wave resonators operating at 60.625 MHz. This paper presents the 3D multi-physics design and analysis of the accelerating structures and beam dynamics studies of the linac.

47 OTHER INSTRUMENTATION↗

Application of an alkylammonium method for characterization of phyllosilicates in CI chondrites

Many meteorites and interplanetary dust particles (IDP's) with primitive compositions contain significant amounts of phyllosilicates, which are generally interpreted as evidence of protoplanetary aqueous alteration at an early period in the solar system. These meteorites are chondrites of the carbonaceous and ordinary varieties. Characterization of phyllosilicates in these materials is important because of the important physico-chemical information they hold, e.g., from well characterized phyllosilicates, thermodynamic stability relations and hence the conditions of formation of phyllosilicates in the parent body of the meteorite can be predicted. Although we are at a rudimentary level of understanding of the minerals resulting from the aqueous alteration in the early solar nebula, we know that the most common phyllosilicates present in chondritic extraterrestrial materials are serpentines, smectites, chlorites, and micas. The characterization of fine grained minerals in meteorites and IDP's rely heavily on electron beam instruments, especially transmission electron microscopy (TEM). Typically, phyllosilicates are identified by a combination of high resolution imaging of basal spacings, electron diffraction analysis, and chemical analysis. Smectites can be difficult to differentiate from micas because the smectites loose their interlayer water and the interlayers collapse to the same basal spacing as mica in the high vacuum of the TEM. In high-resolution TEM (HRTEM) images, smectite basal spacings vary from 1 nm up to 1.5 nm, while micas show 1 or 2 nm basal spacings. Not only is it difficult to differentiate smectites from micas, but there is no way of identifying different classes of smectites in meteorites and IDP's. To differentiate smectites from micas and also to recognize the charge differences among smectites, an alkylammonium method can be employed because the basal spacings of alkylammonium saturated smectites expand as a function of alkylamine chain length and the layer-charge density of the 2:1 expanding phyllosilicate, and the final product is significantly more stable under electron beam examination. Such a method was tested on standard clays and several meteorite samples using four alkylammonium salts.

Golden, D. C.↗

Molecular beam epitaxial growth of BaTiO{sub 3} single crystal on Ge-on-Si(001) substrates

Thin films of perovskite type BaTiO{sub 3} (BTO) oxide have been grown epitaxially directly on Ge(001) surface at high temperature using molecular beam epitaxy. A stable (2x1) BaGe{sub x} surface periodicity is the critical enabling template for subsequent BTO heteroepitaxy on Ge(001). Reflection high energy electron diffraction (RHEED) and transmission electron microscopy indicate that high quality heteroepitaxy on Ge-on-Si(001) take place with <100>BTO(001)||<110>Ge(001) confirming a 45 deg. rotation epitaxial relationship. X-ray diffraction has been used to study the BTO lattice parameters and we evidenced that both tetragonal and cubic phases of BTO are present in the epilayer.

36 MATERIALS SCIENCE↗

Design of a millimeter-wave polarimeter for NSTX-Upgrade and initial test on DIII-D

Polarimetry is a powerful diagnostic technique to probe plasma equilibria and magnetic fluctuations in fusion plasmas. In a high beta plasma such as the National Spherical Torus eXperiment (NSTX), these measurements are important to understand plasma stability and anomalous transport. A 288 GHz polarimeter operating along a major radial chord in retroreflection geometry has been developed and is being tested on the DIII-D tokamak to prepare for future implementation on NSTX-Upgrade. The system launches a rotating linearly polarized beam and detects the phase shift directly related to the polarization change caused by the plasma. To accomplish this, a pair of orthogonal linearly polarized beams with a stable difference frequency is generated using a single sideband modulation technique, then combined and transformed to be counter-rotating circularly polarized. To improve phase resolution, quasi-optical isolation, using Faraday rotators and polarizers, is utilized to eliminate a multi-path feedback effect, which is found to be the primary source of phase error. The bench tests in the laboratory and DIII-D power supply test discharges indicate {<=}1 Degree-Sign phase resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Micromegas TPC for Low Energy Heavy Ions Measurement for Nuclear Fission and Astrophysics Applications

Time Projection Chambers are widely used since many years for tracking and identification of charged particles in high energy physics. We present a new R and D project to investigate the feasibility of a Micromegas TPC for low energy heavy ions detection. Two physics cases are relevant for this project. The first is the study of the nuclear fission of actinides by measuring the fission fragments properties (mass, nuclear charge, kinetic energy) that will be performed at different installations and in particular at the NFS facility to be built in the framework of the SPIRAL2 project in GANIL. The second physics case is the study of heavy ion reactions, like ({alpha},{gamma}), ({alpha},p), ({alpha},n) and all the inverse reactions in the energy range between 1.5 and 3 AMeV using both stable and radioactive beams. These reactions have a key role in p process in nuclear astrophysics to explain the synthesis of heavy proton-rich nuclei. Within the project, a large effort is devoted to Monte-Carlo simulations and a detailed benchmark of different simulation codes on the energy loss and range in gas of heavy ions at low energy has been performed. A new approach for simulating the ion charge state evolution in GEANT4 is also presented. Finally, preliminary results of an experimental test campaign on prototype are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High fusion performance at high T i / T e in JET-ILW baseline plasmas with high NBI heating power and low gas puffing

This article presents the transport analysis of high density baseline discharges in the 2016 experimental campaign of the Joint European Torus with the ITER-Like Wall (JET-ILW), where a significant increase in the deuterium–deuterium (D–D) fusion neutron rate (~2.8 × 10 16 s -1 ) was achieved with stable high neutral beam injection (NBI) powers of up to 28 MW and low gas puffing. Increase in T i exceeding T e were produced for the first time in baseline discharges despite the high electron density; this enabled a significant increase in the thermal fusion reaction rate. As a result, the new achieved record in fusion performance was much higher than the previous record in the same heating power baseline discharges, where T i = T e . In addition to the decreases in collisionality and the increases in ion heating fraction in the discharges with high NBI power, T i > T e can also be attributed to positive feedback between the high T i /T e ratio and stabilisation of the turbulent heat flux resulting from the ion temperature gradient driven mode. The high T i /T e ratio was correlated with high rotation frequency. Among the discharges with identical beam heating power, higher rotation frequencies were observed when particle fuelling was provided by low gas puffing and pellet injection. Lastly, this reveals that particle fuelling played a key role for achieving high T i /T e , and the improved fusion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Runaway electron beam dynamics at low plasma density in DIII-D: energy distribution, current profile, and internal instability

Parameters of the post-disruption runaway electron (RE) beam in the collisionless background plasma achieved after deuterium injection are investigated in DIII-D. The spatially resolved RE energy distribution function is measured for the first time during the RE plateau stage by inverting hard X-ray bremsstrahlung spectra. It has maximum energy up to 20 MeV and a non-monotonous feature at 5{6 MeV observed only in the core of the beam supporting the possibility of kinetic instabilities. The RE current profile is reconstructed for the first time using the spatially resolved RE energy distribution. It is found to be more peaked than the pre-disruption plasma current, with higher internal inductance, suggesting preferential formation of REs in the core plasma or potentially a radially inward motion of the REs. The accessed relatively low-current (180 kA) RE beam is found stable, likely due to its elevated q profile. From this base stable equilibrium, instability is accessed by ramping the solenoid current. Under a large applied accelerating loop voltage an internal kink mode is observed. The kink mode leads to sawtooth-like relaxation of the RE current profile, but drives no RE loss. Under conditions of a large decelerating voltage, chirping Alfvénic instabilities driven by REs during the RE plateau stage are observed for the first time. The low-frequency (0.1{7 MHz) Alfvénic instabilities, supposedly compressional Alfvén eigenmodes, are found to be correlated with a RE loss signal. Finally, this provides novel plasma conditions to study these instabilities and investigate opportunities to utilize them for RE control. Bifurcated electron cyclotron emission (ECE) spectrum is measured during the collisionless RE plateau, with a break point at ≈100 GHz suggesting resonant absorption of the ECE at low frequencies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic quadrupole moments in 124 $\mathrm{Xe}$

The Xe isotopic chain with four valence protons above the Z=50 shell closure is an ideal laboratory for the study of the evolution of nuclear deformation. At the N=82 shell closure, 136 Xe presents all characteristics of a doubly closed shell nucleus with a spherical shape. In the very neutron-deficient isotopes close to N=50, the α-decay chain of Xe was investigated to probe the radioactive decay properties near the drip-line and the magicity of 100 Sn. Additionally, the Xe isotopes present higher order symmetries in the nuclear deformation such as the octupole degree of freedom near N=60 and N=90 or O(6) symmetry in stable isotopes. The relevance of the O(6) symmetry has been investigated by measuring the spectroscopic quadrupole moment of the first excited states in 124 Xe. In the O(6) symmetry limit, the spectroscopic quadrupole moment of collective states is expected to be null. A stable 124 Xe beam with energies of 4.03A MeV and 4.11 A MeV was used to bombard a nat W target at the GANIL facility. Excited states were populated via the safe Coulomb excitation reaction. The collision of the heavy ions with a large Z at low energy make this reaction sensitive to the diagonal E2 matrix element of the excited states. The recoils were detected in the VAMOS++ magnetic spectrometer and the γ rays in the AGATA tracking array. The least squares fitting code gosia was used for the analysis to extract both E2 and M1 transitional and E2 diagonal matrix elements. The rotational ground state band was populated up to the 8$^{+}_{1}$ state as well as the 2$^{+}_{2}$ and 4$^{+}_{2}$ states. Using high precision spectroscopic data to constrain the gosia fit, the spectroscopic quadrupole moments of the 2$^{+}_{1}$, 4$^{+}_{1}$, and 6$^{+}_{1}$ states were determined for the first time. The spectroscopic quadrupole moments were found to be negative, large, and constant in the ground state band underlining the prolate axially deformed ground state band of 124 Xe. Here, the present experimental data confirm that the O(6) symmetry is substantially broken in 124 Xe .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗