Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SQUIDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High Resolution Thermometry for EXACT

High Resolution Thermometers (HRTs) based on SQUID detection of the magnetization of a paramagnetic salt or a metal alloy has been commonly used for sub-nano Kelvin temperature resolution in low temperature physics experiments. The main applications to date have been for temperature ranges near the lambda point of He-4 (2.177 K). These thermometers made use of materials such as Cu(NH4)2Br4 *2H2O, GdCl3, or PdFe. None of these materials are suitable for EXACT, which will explore the region of the He-3/He-4 tricritical point at 0.87 K. The experiment requirements and properties of several candidate paramagnetic materials will be presented, as well as preliminary test results.

Panek, J. S.↗

SAFIRE: A Far-Infrared Imaging Spectrometer for SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 micrometers-655 micrometers with spectral resolving power of approx. 1500 (200km/s). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background-limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors. An engineering prototype of SAFIRE with a small but cutting edge detector array will be available for use during the initial SOFIA operations; further expansion to larger format arrays will be incorporated during SAFIRE's lifetime.

Shafer, Richard A.↗

First Astronomical Use Of Multiplexed Transition Edge Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing five orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering delta-lamda/lamda = 1/7 at a resolution of delta-lamda/lamda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve doppler broadened line emission from external galaxies. FIBRE operates in the 350 micrometer and 450 micrometer bands. These bands cover line emission from the important PDR tracers neutral carbon [CI] and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Benford, D. J.↗

Microcalorimetry: The First Two Decades

Our group at GSFC began experimental and theoretical work on microcalorimetry almost twenty years ago, in August of 1982. Over the next 10 months, we completed the initial demonstration of a Si impurity thermometer-based calorimeter as an X-ray spectrometer. This successful demonstration resulted in the development by many investigators of scientific applications for microcalorimeters, ranging from optical spectroscopy to dark matter detection to particle physics applications. Many new technical approaches for cryogenic detectors were proposed by investigators and have been developed. In this presentation, I will describe the early development of microcalorimeters at GSFC and University of Wisconsin and the subsequent rapid growth of this work around the world The key milestones in the early development were the initial spectroscopy demonstrations and the selection of XRS, our microlcalorimeter-based instrument for the Advanced X-ray Astrophysics Facility (AXAF) and ultimately for ASTRO-E. An additional key event was the development of the direct detection of dark matter experiment and the formation of the Center for Particle Astrophysics. Both of these programs provided long term support for this technology in its precarious early days. A major additional technical step in the development of detectors was the demonstration of devices based on superconducting transition edge sensors (TES). These detectors promised (and have delivered) improved energy resolution and higher event rate capabilities. They couple naturally to SQUIDS, which operate well at the low temperatures where the detectors must operate. The past two decades have taken microcalorimeters from their infancy to applications in real experiments. I will provide an overview of the early development of the devices and review the breadth of the present technology and applications.

Moseley, Harvey↗

New technologies for the detection of millimeter and submillimeter waves

Voltage-biased superconducting bolometers have many operational advantages over conventional bolometer technology including sensitivity, linearity, speed, and immunity from environmental disturbance. A review is given of the Berkeley program for developing this new technology. Developments include fully lithographed individual bolometers in the spiderweb configuration, arrays of 1024 close-packed absorber-coupled bolometers, antenna-coupled bolometers, and a frequency-domain SQUID (superconducting quantum interference device) readout multiplexer.

Richards, P. L.↗

Kinetic Inductance Photodetectors Based on Nonequilibrium Response in Superconducting Thin-Film Structures

While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitivity at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of approximately 1 ms at 1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as approximately 10(exp -19) W/Hz(exp 1/2) at He4 temperatures.

Sergeev, A. V.↗

Multiplexed Readout of Thermal Bolometers with Superconducting Transition Edge Thermometers

History shows that in astronomy, more is better. In the near future, direct detector arrays for the far-infrared and submillimeter will contain hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and has been developed using SQUIDs. The technology permits a 32 x 32 array of bolometers to be read out using approximately 100 wires rather than the >2000 needed with direct wiring. These bolometer arrays are made by micromachining techniques, using superconducting transition edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the Submillimeter and Far Infrared Experiment (SAFIRE) instrument on Stratospheric Observatory for Infrared Astronomy (SOFIA), and is a candidate for a wide variety of other spectroscopic and photometric instruments.

Benford, Dominic J.↗

Far-Infrared Imaging Spectroscopy with SAFIRE on SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 100 micrometers - 655 micrometers, with spectral resolving power of approx. 1500 (200 kilometers per second). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up barometer array in a 16 x 32 format to provide background-limited imaging spectrometry. Superconducting transition edge barometers and SQUID amplifiers have been developed for these detectors.

Shafer, Richard A.↗

SAFIRE: Far-Infrared Imaging Spectroscopy with SOFIA

The SOFIA airborne observatory will provide a high spatial resolution, low background telescope for far-infrared astrophysical investigations. Selected as a PI instrument for SOFIA, SAFIRE is an imaging Fabry-Perot spectrograph covering 145 microns-655microns, with spectral resolving power of approx. 1500 (200 kilometers per second). This resolution is well matched to extragalactic emission lines and yields the greatest sensitivity for line detection. SAFIRE will make important scientific contributions to the study of the powering of ULIRGs and AGN, the role of CII cooling in extragalactic star formation, the evolution of matter in the early Universe, and the energetics of the Galactic center. SAFIRE will employ a two-dimensional pop-up bolometer array to provide background limited imaging spectrometry. Superconducting transition edge bolometers and SQUID amplifiers have been developed for these detectors.

Benford, Dominic↗

Design and Fabrication of a Two-Dimensional Superconducting Bolometer Array

Large format, two dimensional arrays of close-packed bolometers will enable submillimeter cameras and spectrometers to obtain images and spectra orders of magnitude faster than present instruments. The South Pole Imaging Fabry-Perot Interferometer (SPIFI) for the AST/RO observatory and the Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, closepacked bolometer arrays. Both these instruments are imaging Fabry-Perot spectrometers operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this purpose. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs of order 5x10(exp 18) W/square root of Hz. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. We have fabricated an engineering model array with this technology which features a very compact, modular approach for large format arrays.

Benford, Dominic↗

Design and Fabrication of Two-Dimensional Superconducting Bolometer Array for SAFIRE

The Submillimeter and Far-InfraRed Experiment (SAFIRE) on the SOFIA airborne observatory will employ a large-format, two-dimensional, close-packed bolometer array. SAFIRE is an imaging Fabry-Perot spectrometer operating at wavelengths between 100 micron and 700 micron. The array format is 16x32 pixels, using a 32-element multiplexer developed in part for this instrument. The low backgrounds achieved in spectroscopy require very sensitive detectors with NEPs (Noise Equivalent Powers) of order 5x10(exp 18)W/square root of Hz. An architecture which permits 512 pixels to be placed adjacent to each other in an area the size of a postage stamp, integrate them with multiplexers, and provide all the necessary wiring interconnections is a complex proposition, but can be achieved. Superconducting detectors can be close-packed using the Pop-Up Detector (PUD) format, and SQUID multiplexers operating at the detector bas temperature can be intimately coupled to them. The result is a compact array, easily scalable to kilopixel arrays. Engineering results from the first such detector arrays will be presented.

Benford, Dominic↗

Ideal Integrating Bolometer

We describe a new 'ideal integrator' bolometer as a prototype for a new generation of sensitive, flexible far-IR detectors suitable for use in large arrays. The combination of a non-dissipative sensor coupled with a fast heat switch provides breakthrough capabilities in both sensitivity and operation. The bolometer temperature varies linearly with the integrated infrared power incident on the detector, and may be sampled intermittently without loss of information between samples. The sample speed and consequent dynamic range depend only on the heat switch reset cycle and can be selected in software. Between samples, the device acts as an ideal integrator with noise significantly lower than resistive bolometers. Since there is no loss of information between samples, the device is well-suited for large arrays. A single SQUID readout could process an entire column of detectors, greatly reducing the complexity, power requirements, and cost of readout electronics for large pixel arrays.

Kogut, Alan↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Oceans, Ice Shells, and Life on Europa

The four large satellites of Jupiter are famous for their planet-like diversity and complexity, but none more so than ice-covered Europa. Since the provocative Voyager images of Europa in 1979, evidence has been mounting that a vast liquid water ocean may lurk beneath the moon's icy surface. Europa has since been the target of increasing and sometimes reckless speculation regarding the possibility that giant squid and other creatures may be swimming its purported cold, dark ocean. No wonder Europa tops everyone's list for future exploration in the outer solar system (after the very first reconnaissance of Pluto and the Kuiper belt, of course). Europa may be the smallest of the Galilean moons (so-called because they were discovered by Galileo Galilei in the early 17th century) but more than makes up for its diminutive size with a crazed, alien landscape. The surface is covered with ridges hundreds of meters high, domes tens of kilometers across, and large areas of broken and disrupted crust called chaos. Some of the geologic features seen on Europa resemble ice rafts floating in polar seas here on Earth-reinforcing the idea that an ice shell is floating over an ocean on this Moon-size satellite. However, such features do not prove that an ocean exists or ever did. Warm ice is unusually soft and will flow under its own weight. If the ice shell is thick enough, the warm bottom of the shell will flow, as do terrestrial glaciers. This could produce all the observed surface features on Europa through a variety of processes, the most important of which is convection. (Convection is the vertical overturn of a layer due to heating or density differences-think of porridge or sauce boiling on the stove.) Rising blobs from the base of the crust would then create the oval domes dotting Europa's surface. The strongest evidence for a hidden ocean beneath Europa's surface comes from the Galileo spacecraft's onboard magnetometer, which detected fluctuations in Jupiter's magnetic field consistent with a conductor inside Europa. The most likely conductor: a somewhat salty ocean.

Schenk, Paul↗

Antiferromagnetic Interlayer Exchange Coupling in All-Semiconducting EuS/PbS/EuS Trilayers

A comprehensive experimental study on the antiferromagnetic interlayer exchange coupling in high quality epitaxial all-semiconducting EuSPbSEuS trilayers is reported. The influence of substrates, the thickness of the non-magnetic PbS spacer layer, and of temperature, was investigated by means of SQUID magnetometry. In trilayers with a PbS thickness between 4 and 12 deg A the low temperature hysteresis loops showed the signature of antiferromagnetic coupling. The value of the interlayer exchange coupling energy was determined by simulating the data with a modified Stoner model, including Zeeman, anisotropy, and exchange coupling energies. An important observation was of a strong dependence of the interlayer exchange coupling energy on temperature, consistent with a power law dependence of the exchange coupling constant on the saturation magnetization of the EuS layers. While no theoretical description is readily available, we conjecture that the observed behavior is due to a dependence of the interlayer exchange coupling energy on the exchange splitting of the EuS conduction band.

Smits, C. J. P.↗

Investigations of Relatively Easy To Construct Antennas With Efficiency in Receiving Schumann Resonances: Preparations for a Miniaturized Reconfigurable ELF Receiver

Relatively little is known about the cavity between the Earth and the ionosphere, which opens opportunities for technological advances and unique ideas. One effective means to study this cavity is with extremely low frequency (ELF) antennas. Possible applications of these antennas are global weather prediction, earthquake prediction, planetary exploration, communication, wireless transmission of power, or even a free energy source. The superconducting quantum interference device SQUID) and the coil antenna are the two most acceptable receivers discovered for picking up ELF magnetic fields. Both antennas have the potential for size reduction, allowing them to be portable enough for access to space and even for personal ware. With improvements of these antennas and signal processing, insightful analysis of Schumann resonance (SR) can give the science community a band of radio frequency (RF) signals for improving life here on Earth and exploring beyond.

Farmer, Brian W.↗

A Dry-Etch Process for Low Temperature Superconducting Transition Edge Sensors for Far Infrared Bolometer Arrays

The next generation of ultra-low power bolometer arrays, with applications in far infrared imaging, spectroscopy and polarimetry, utilizes a superconducting bilayer as the sensing element to enable SQUID multiplexed readout. Superconducting transition edge sensors (TES s) are being produced with dual metal systems of superconductinghormal bilayers. The transition temperature (Tc) is tuned by altering the relative thickness of the superconductor with respect to the normal layer. We are currently investigating MoAu and MoCu bilayers. We have developed a dry-etching process for MoAu TES s with integrated molybdenum leads, and are working on adapting the process to MoCu. Dry etching has the advantage over wet etching in the MoAu system in that one can achieve a high degree of selectivity, greater than 10, using argon ME, or argon ion milling, for patterning gold on molybdenum. Molybdenum leads are subsequently patterned using fluorine plasma.. The dry-etch technique results in a smooth, featureless TES with sharp sidewalls, no undercutting of the Mo beneath the normal metal, and Mo leads with high critical current. The effects of individual processing parameters on the characteristics of the transition will be reported.

Allen, Christine A.↗

Development of a Cryogen-Free Continuous ADR for the Constellation-X Mission

Constellation-X is a multi-satellite x-ray astronomy mission presently being planned for launch in the 2010 time frame. Each of 4 identical satellites will contain a telescope and instruments for imaging and spectroscopic analysis of both hard and soft x-rays. The X- ray Microcalorimeter Spectrometer (XMS) instrument will use arrays of microcalorimeters to detect X-rays with energies from 0.2 to 6 keV. The technologies under development for this instrument include Transition-Edge Sensors (TES) with multiplexed SQUID readouts and NTD-Ge detectors with JFET readouts. Both will be operated at temperatures in the 50-60 mK range and both have a projected cooling power requirement of approximately 5 microwatts. In addition, in order to meet the lifetime requirement of 6 years (with a goal of 10 years), a mechanical cryocooler will be used to provide a heat sink for the low temperature cooler. The required performance is 20 mW at 6 K, with a goal of 4 K operation. In this paper we present the development status of an adiabatic demagnetization refigerator (ADR) that meets the cooling requirements of the X M S instrument. At present we have demonstrated a 4-stage ADR that operates continuously at 50 mK using a 4.2 K helium bath as a heat sink. The cooling power is 21 microwatts at 100 mK and 6 microwatts at 50 mK. Its efficiency when operating at 50 mK is 1 1 % of Carnot (accounting for all dissipation at 4.2 K and below, but not including power dissipation in the room temperature electronics), but this is expected to rise to 25% in the next generation system in which active gas-gap heat switches are replaced with passive devices. This will reduce the peak heat rejection rate of the ADR to less than 7 mW at 6 K. Details of the ADR s design and operation, as well as the development program leading up to a flight-qualified instrument, will be discussed.

Shirron, Peter↗