Low-frequency noise in β-(Al x Ga1 −x )2O3 Schottky barrier diodes

We report on the low-frequency electronic noise in β-(AlxGa1−x)2O3 Schottky barrier diodes. The noise spectral density reveals 1/f dependence, characteristic of the flicker noise, with superimposed Lorentzian bulges at the intermediate current levels (f is the frequency). The normalized noise spectral density in such diodes was determined to be on the order of 10−12 cm2/Hz (f = 10 Hz) at 1 A/cm2 current density. At the intermediate current regime, we observed the random telegraph signal noise, correlated with the appearance of Lorentzian bulges in the noise spectrum. The random telegraph signal noise was attributed to the defects near the Schottky barrier. The defects can affect the local electric field and the potential barrier and, correspondingly, impact the electric current. The obtained results help in understanding the noise in Schottky barrier diodes made of ultra-wide bandgap semiconductors and can be used for the material and device quality assessment.

Physics↗

Instrumentation for measuring the dynamic pressure on rotating compressor blades

To establish the capability for measurement of oscillatory pressure on rotating blades, miniature fast response semiconductor strain gage pressure transducers (2mm x 0.33mm) were mounted in several configurations on thin titanium and steel compressor blades and subjected to pressure cycles from 1 to 310 kPa during static tests and spin tests. Static test conditions included 20 C to 150 C, 0 to 3000 tensile microstrain, -1000 to +1000 bending microstrain and + or - 650G vibration. The spin test conditions included 20 C to 82 C at 0 to 90,000G. Durability was excellent. Pressure transducer sensitivity changed by only a few percent over this range of environmental conditions. Noise signal due to oscillatory acceleration normal to the diaphragm was acceptable (0.33Pa/G). Noise signal due to oscillatory strain was acceptable (0.5 Pa/microstrain) when the transducer was mounted on a 0.05mm rubber pad, with a total buildup of 0.38mm on the measure surface. Back mounting or partial recessing to eliminate buildup, increased the strain effect to 1.2 Pa/microstrain. Flush mounting within the blade to eliminate buildup reduced the strain effect, but required development of a special transducer shape. This transducer was not available in time for spin tests. Unpredictable zero drift + or - 14 kPa ruled out the use of these mounting arrangements for accurate steady-state (D.C.) measurements on rotating blades. The two best configurations fully developed and spin tested were then successfully applied in the NAS3-20606 rotating fan flutter program for quantitative measurement of oscillatory pressure amplitudes.

Grant, H. P.↗

Oscillation Detection Algorithm Development Summary Report and Test Plan

Small signal stability problems are one of the major threats to grid stability and reliability in California and the western U.S. power grid. An unstable oscillatory mode can cause large-amplitude oscillations and may result in system breakup and large-scale blackouts. There have been several incidents of system-wide oscillations. Of them, the most notable is the August 10, 1996 western system breakup produced as a result of undamped system-wide oscillations. There is a great need for real-time monitoring of small-signal oscillations in the system. In power systems, a small-signal oscillation is the result of poor electromechanical damping. Considerable understanding and literature have been developed on the small-signal stability problem over the past 50+ years. These studies have been mainly based on a linearized system model and eigenvalue analysis of its characteristic matrix. However, its practical feasibility is greatly limited as power system models have been found inadequate in describing real-time operating conditions. Significant efforts have been devoted to monitoring system oscillatory behaviors from real-time measurements in the past 20 years. The deployment of phasor measurement units (PMU) provides high-precision time-synchronized data needed for estimating oscillation modes. Measurement-based modal analysis, also known as ModeMeter, uses real-time phasor measure-ments to estimate system oscillation modes and their damping. Low damping indicates potential system stability issues. Oscillation alarms can be issued when the power system is lightly damped. A good oscillation alarm tool can provide time for operators to take remedial reaction and reduce the probability of a system breakup as a result of a light damping condition. Real-time oscillation monitoring requires ModeMeter algorithms to have the capability to work with various kinds of measurements: disturbance data (ringdown signals), noise probing data, and ambient data. Several measurement-based modal analysis algorithms have been developed. They include Prony analysis, Regularized Ro-bust Recursive Least Square (R3LS) algorithm, Yule-Walker algorithm, Yule-Walker Spectrum algorithm, and the N4SID algo-rithm. Each has been shown to be effective for certain situations, but not as effective for some other situations. For example, the traditional Prony analysis works well for disturbance data but not for ambient data, while Yule-Walker is designed for ambient data only. Even in an algorithm that works for both disturbance data and ambient data, such as R3LS, latency results from the time window used in the algorithm is an issue in timely estimation of oscillation modes. For ambient data, the time window needs to be longer to accumulate information for a reasonably accurate estimation; while for disturbance data, the time window can be significantly shorter so the latency in estimation can be much less. In addition, adding a known input signal such as noise probing signals can increase the knowledge of system oscillatory properties and thus improve the quality of mode estimation. System situations change over time. Disturbances can occur at any time, and probing signals can be added for a certain time period and then removed. All these observations point to the need to add intelligence to ModeMeter applications. That is, a ModeMeter needs to adaptively select different algorithms and adjust parameters for various situations. This project aims to develop systematic approaches for algorithm selection and parameter adjustment. The very first step is to detect occurrence of oscillations so the algorithm and parameters can be changed accordingly. The proposed oscillation detection approach is based on the signal-noise ratio of measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Variability in surface ECG morphology: signal or noise?

Using data collected from canine models of acute myocardial ischemia, we investigated two issues of major relevance to electrocardiographic signal averaging: ECG epoch alignment, and the spectral characteristics of the beat-to-beat variability in ECG morphology. With initial digitization rates of 1 kHz, an iterative a posteriori matched filtering alignment scheme, and linear interpolation, we demonstrated that there is sufficient information in the body surface ECG to merit alignment to a precision of 0.1 msecs. Applying this technique to align QRS complexes and atrial pacing artifacts independently, we demonstrated that the conduction delay from atrial stimulus to ventricular activation may be so variable as to preclude using atrial pacing as an alignment mechanism, and that this variability in conduction time be modulated at the frequency of respiration and at a much lower frequency (0.02-0.03Hz). Using a multidimensional spectral technique, we investigated the beat-to-beat variability in ECG morphology, demonstrating that the frequency spectrum of ECG morphological variation reveals a readily discernable modulation at the frequency of respiration. In addition, this technique detects a subtle beat-to-beat alternation in surface ECG morphology which accompanies transient coronary artery occlusion. We conclude that physiologically important information may be stored in the variability in the surface electrocardiogram, and that this information is lost by conventional averaging techniques.

NASA Discipline Cardiopulmonary↗

A Test for the Existence of Mach Effects with a Rotary Device

Owing to the variation in the results of several experiments designed to produce thrust with devices employing Mach effects, it was decided to design an experiment with the simple purpose of determining whether or not Mach effects actually exist, and if they can be produced when the ''bulk'' acceleration and internal energy changes required to produce them are separately supplied. In the experiment arrays of eight 500 pf high voltage capacitors are mounted on the end of a rotor and spun to and from speeds of about 60 Hz (3600 rpm) while they are excited with a 40 KHz voltage signal with amplitudes up to 6 KV. The capacitors are sandwiched between two accelerometers and any Mach effect mass fluctuation is detected as a weight fluctuation that produces signals in the accelerometers that are antiphase. Those signals are subtracted with a differential instrumentation amplifier that suppresses other signals as common mode noise. Signals with the properties sought have been found and recorded with video equipment. They suggest that Mach effects are real, and that the bulk accelerations and internal energy changes that produce them can in fact be separately supplied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communication device, spread-spectrum receiver, and related method using normalized matched filter for improving signal-to-noise ratio in harsh environments

A communication device, a method of operating a communication device, and a spread-spectrum receiver are disclosed. The method includes receiving an incoming RF signal, demodulating the incoming RF signal to generate a baseband signal, filtering the baseband signal with a normalized matched filter having filter characteristics matched to a pulse-shaping filter of the transmitter that generated the incoming RF signal, and extracting a received signal from a normalized output generated by the normalized matched filter. As a result, interferences and noise from harsh environments may be suppressed.

42 ENGINEERING↗

Automatic Gaussian random-noise limiter

Circuit limits the positive and negative peaks of a random-noise signal. It accurately establishes a known limiting level relative to any given RMS value of the random-noise signal input.

Woodbury, R. C.↗

Increased signal-to-noise ratios within experimental field trials by regressing spatially distributed soil properties as principal components

Environmental variability poses a major challenge to any field study. Researchers attempt to mitigate this challenge through replication. Thus, the ability to detect experimental signals is determined by the degree of replication and the amount of environmental variation, noise, within the experimental system. A major source of noise in field studies comes from the natural heterogeneity of soil properties which create microtreatments throughout the field. In addition, the variation within different soil properties is often nonrandomly distributed across a field. We explore this challenge through a sorghum field trial dataset with accompanying plant, microbiome, and soil property data. Diverse sorghum genotypes and two watering regimes were applied in a split-plot design. We describe a process of identifying, estimating, and controlling for the effects of spatially distributed soil properties on plant traits and microbial communities using minimal degrees of freedom. Importantly, this process provides a method with which sources of environmental variation in field data can be identified and adjusted, improving our ability to resolve effects of interest and to quantify subtle phenotypes.

60 APPLIED LIFE SCIENCES↗

Audibility of Multiple, Low-Frequency Tonal Signals in Noise

The main purpose of this study is to examine the audibility of multiple, low-frequency tones that are placed in distinct auditory channels. Three experiments are described, the goals of which are to determine if the presence of sound in multiple channels results in enhanced audibility and to assess the applicability of the Statistical Summation Model (SSM) to this frequency range. This model predicts that for the case of multiple signals that are in separate auditory channels, implying statistical independence, each with sensitivity value d prime of i, the resulting total sensitivity is given by the square root of the sum of the squares of the individual d prime of i values. In common with previous studies conducted at higher frequencies, the signals are pure tones and the maskers are broadband noise. The requirement that low frequency tones be placed in separate auditory filters limited the number of tones to a maximum of three. The first of the three experiments measured the change in masked thresholds for two- and three-tone signals relative to the level of the equally-detectable single tones. The multiple tone signals were composed of combinations of 55, 120 and 200 Hz tones. The measured changes in thresholds exceeded those predicted by the SSM, although they did not differ statistically from the model predictions. The second experiment employed the same overall approach but acquired more data and concentrated on the three-tone signal. Once again, the measured changes in masked threshold exceeded the model predictions, this time to a statistically-significant degree. Two issues were postulated with the potential to yield inflated changes in masked threshold: interaction between tones resulting in perceptible intermodulation/difference tones, and the assumption that the tones were in distinct auditory filters and statistically independent of one another. The third experiment used two sets of three-tone signals to address these latter concerns. The first set of three tones was composed of harmonically related tone frequencies of 55, 110 and 165 Hz, which was an attempt to reduce effects of intermodulation difference tones. The second set of three tones was chosen to be 110, 220 and 330 Hz, again reducing effects of difference tones, but also providing greater separation between tones. Results for the first set of three tones compared to those of the earlier experiments indicated that intermodulation was not an important effect. The second set of three tones (110, 220, 330 Hz) yielded changes in masked thresholds that, on average, were in good agreement with the SSM, although intersubject variability was large and prohibited a definitive conclusion regarding the concern that tone spacing was inadequate. The results of the three experiments showed that the masked threshold of sounds with multiple (two or three) equally-detectable low frequency tones was lower than those of the single tones. In other words, it is clear that audibility is enhanced by the presence of signals in multiple auditory filters. This finding is consistent with most previous research conducted at higher frequencies. In contrast with previous research, test subjects were, on average, able to detect multitone sounds at lower levels than those predicted using the SSM. Analyses that included Monte Carlo simulations showed that normally distributed errors in the single tone thresholds result in biased estimates of the thresholds of multitone sounds. This phenomenon is likely responsible for at least a substantial fraction of the unexpected deviation of measurements from SSM predictions.

Rafaelof, Menachem↗

Spin noise spectroscopy of ZnO

We investigate the thermal equilibrium dynamics of electron spins bound to donors in nanoporous ZnO by optical spin noise spectroscopy. The spin noise spectra reveal two noise contributions: A weak spin noise signal from undisturbed localized donor electrons with a dephasing time of 24 ns due to hyperfine interaction and a strong spin noise signal with a spin dephasing time of 5 ns which we attribute to localized donor electrons which interact with lattice defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced study of video signal processing in low signal to noise environments

A nonlinear analysis of a multifilter phase-lockloop (MPLL) by using the method of harmonic balance is presented. The particular MPLL considered has a low-pass filter and a band-pass filter in parallel. An analytic expression for the relationship between the input signal phase deviation and the phase error is determined for sinusoidal FM in the absence of noise. The expression is used to determine bounds on the proper operating region for the MPLL and to investigate the jump phenomenon previously observed. From these results the proper modulation index, modulating frequency, etc. used for the design of a MPLL are determined. Data for the loop unlock boundary obtained from the theoretical expression are compared to data obtained from analog computer simulations of the MPLL.

Carden, F.↗

Signal detection amid noise with known statistics

Conventional methods of signal detection are based on the comparison of a local signal-to-noise ratio S/N to some threshold value. We present a new method that compares instead the histogram of the data with the one expected for background noise alone. Signals are detected from discrepancies between the two. We expect it to be applicable in the detection of signals from any data whose background statistics is known. To illustrate the method, we apply it to the case of photon-limited imaging data where the underlying background is Poissonian. Numerical simulations are used to check the efficiency of our method, finding that for signals with low S/N (less than 5), it detects signals with a higher degree of reliability than the conventional method.

Zepka, A. F.↗

Boosting the signal-to-noise of low-field MRI with deep learning image reconstruction

Recent years have seen a resurgence of interest in inexpensive low magnetic field (< 0.3 T) MRI systems mainly due to advances in magnet, coil and gradient set designs. Most of these advances have focused on improving hardware and signal acquisition strategies, and far less on the use of advanced image reconstruction methods to improve attainable image quality at low field. We describe here the use of our end-to-end deep neural network approach (AUTOMAP) to improve the image quality of highly noise-corrupted low-field MRI data. We compare the performance of this approach to two additional state-of-the-art denoising pipelines. We find that AUTOMAP improves image reconstruction of data acquired on two very different low-field MRI systems: human brain data acquired at 6.5 mT, and plant root data acquired at 47 mT, demonstrating SNR gains above Fourier reconstruction by factors of 1.5- to 4.5-fold, and 3-fold, respectively. In these applications, AUTOMAP outperformed two different contemporary image-based denoising algorithms, and suppressed noise-like spike artifacts in the reconstructed images. The impact of domain-specific training corpora on the reconstruction performance is discussed. The AUTOMAP approach to image reconstruction will enable significant image quality improvements at low-field, especially in highly noise-corrupted environments.

42 ENGINEERING↗

Real-time in Situ Signal-to-noise Ratio Estimation for the Assessment of Operational Communications Links

The work presented here formulates the rigorous statistical basis for the correct estimation of communication link SNR of a BPSK, QPSK, and for that matter, any M-ary phase-modulated digital signal from what is known about its statistical behavior at the output of the receiver demodulator. Many methods to accomplish this have been proposed and implemented in the past but all of them are based on tacit and unwarranted assumptions and are thus defective. However, the basic idea is well founded, i.e., the signal at the output of a communications demodulator has convolved within it the prevailing SNR characteristic of the link. The acquisition of the SNR characteristic is of the utmost importance to a communications system that must remain reliable in adverse propagation conditions. This work provides a correct and consistent mathematical basis for the proper statistical 'deconvolution' of the output of a demodulator to yield a measure of the SNR. The use of such techniques will alleviate the need and expense for a separate propagation link to assess the propagation conditions prevailing on the communications link. Furthermore, they are applicable for every situation involving the digital transmission of data over planetary and space communications links.

Manning, Robert M.↗

Gravitational lensing as signal and noise in Lyman-{alpha} forest measurements

In Lyman-{alpha} forest measurements it is generally assumed that quasars are mere background light sources which are uncorrelated with the forest. Gravitational lensing of the quasars violates this assumption. This effect leads to a measurement bias, but more interestingly it provides a valuable signal. The lensing signal can be extracted by correlating quasar magnitudes with the flux-power spectrum and with the flux decrement. These correlations will be challenging to measure but their detection provides a direct measure of how features in the Lyman-{alpha} forest trace the underlying mass density field. Observing them will test the fundamental hypothesis that fluctuations in the forest are predominantly driven by fluctuations in mass, rather than in the ionizing background, helium reionization, or winds. We discuss ways to disentangle the lensing signal from other sources of such correlations, including dust, continuum, and background residuals. The lensing-induced measurement bias arises from sample selection: one preferentially collects spectra of magnified quasars which are behind overdense regions. This measurement bias is {approx}0.1-1% for the flux-power spectrum, optical depth, and the flux probability distribution. Since the effect is systematic, quantities such as the amplitude of the flux-power spectrum averaged across scales should be interpreted with care.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.