Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHIFT REGISTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

WE-A-17A-05: Differences in Applicator Configuration and Dwell Loading Between Standard and Image-Guided Tandem and Ring (T and R) HDR Brachytherapy

Purpose: To investigate differences in: (i) relative location of the tandem and the ring compared to a rigid standard applicator model; and (ii) relative loading and changes in loading pattern between standard and image-guided planning. Methods: All T and R insertions performed in 2013 in our institution under CT- or MR-guidance were analyzed. Standard plans were generated using library applicator models with a fixed relationship between ring and tandem, standardized uniform dwell loading and normalization to point A. The graphic plans and the associated standard-plan dwell configurations were compared: the rings were rigidly registered, and the residual tandem shift, rotation and maximum distance between plan tandem dwell and corresponding model tandem dwell were calculated. The normalization ratio (NR = the ratio of graphic versus standard-plan total reference air kerma [TRAK]), the general loading difference (GLD = the difference between graphic and standard ratios of the tandem versus the ring TRAK), and the percent standard deviation (SD% = SD/mean) of the tandem and the ring TRAK for the graphic plan (all standard-plans SD% = 0) were calculated. Results: 71 T and R were analyzed. Residual tandem shift, rotation and maximum corresponding dwell distance were 1.2±0.8mm (0.4±0.4mm lateral, 0.9±0.8mm craniocaudal, 0.4±0.3mm anterior-posterior), 2.3±1.9deg and 3.4±2.3mm. NR was 0.86±0.11 indicating a lower overall loading of the graphic compared to the standard plans. GLD was -0.12±0.16 indicating a modest increased ring loading relative to the tandem in the graphic plans. SD% was 2.1±1.6% for tandem and 2.8±1.9% for ring, indicating small deviations from uniform loading. Conclusion: Variability in the relative locations of the tandem and the ring necessitates the independent registration of each component model for accurate digitization. Our clinical experience suggests that graphically planned T and R results on average in a lower total dose to the patient, and in an increased relative loading of the ring component.

60 APPLIED LIFE SCIENCES↗

Airborne Doppler-lidar and ground-based Doppler radar observations of a thunderstorm in Oklahoma

The results of airborne Doppler-lidar and ground-based Doppler radar observations of multicellular storms, marked by heavy rainfall, strong surface outflow, and a gust-front tornado, on June 30, 1981 are analyzed. The airborne lidar comprised a CO2-laser operating in the IR region, which was discharged once each second at 20 deg fore and aft, alternatively, of the normal to the aircraft's heading, and a quarter-wave plate for registering the returning frequency-shifted beams. Wind fields are plotted taking into account the advection effects. The lidar data set is noted for its self-consistency, though limited to a range of 5 km by the high moisture levels. Fair agreement was found between the lidar-derived and radar-derived average ground-based radial wind fields, with discrepancies on the order of 1.5 m/s.

Bluestein, H. B.↗

Efficacy of Compression Garments to Simulate Fluid Shifts during Lunar Bedrest

The effectiveness of JOBST(Registered TradeMark) compression stockings for fluid redistribution was examined in the lunar bed rest analog based on Digital Astronaut computer model predictions. NASA's future goals include missions to the moon which will require extended exposure to the lunar gravity environment. To prepare for these missions, physiological adaptations in various systems must be resolved. A bed rest at a 10 degree head-up tilt was used to simulate lunar gravity. Plasma volume (PV) loss may cause some of the cardiovascular adaptations which occur during space flight so PV is measured in the bed rest analog to evaluate fluid loss. PV varies from individual to individual so PV index (PVI) is used to determine the magnitude and time course of fluid shift and cardiovascular adaptation to 1/6 g. The Digital Astronaut, a computer simulation tool, predicts a 6% PV loss during an extended simulated lunar mission for a male with a body surface area of 1.95 m(exp 2). Simple geometry calculations suggest that 10 degree head-up tilt is most useful for simulated measurement of deconditioning in bone and muscle, however, 2 degree head-up tilt may best imitate cardiovascular fluid shifts. In order to reconcile these different models, compression stocking must be used in the 10 degree paradigm to better approximate expected cardiovascular changes.

Brinley, Alaina↗

SU-C-19A-04: Evaluation of Patient Positioning Reproducibility with Three Supine Breast Boards

Purpose: To evaluate positioning reproducibility using three commercially available breast board immobilization systems for whole breast radiation therapy. Methods: Weekly pre-treatment cone beam CT images from 18 free-breathing breast radiotherapy patients, each immobilized with one of three breast boards, were retrospectively registered to the planning CT. Relative shifts between breast tissue and sternum/chest wall (CW), and breast tissue and spine compared to planning CT were obtained for each board. Positioning reproducibility, inter-patient variation and intra-patient variation were evaluated by group mean (M), standard deviation of group mean (Σ) and standard deviation of random shift (σ). Margins to account for setup uncertainties were calculated based on shift uncertainties in x, y, and z directions. Results: For breast positioning relative to sternum/CW, the average shift from planned positioning was 4.5mm (95% CI: 3.5 – 5.3), 3.3mm (CI: 2.9 - 3.8) and 2.6mm (CI: 1.8 - 3.5) for Breast Boards I, II, and III, respectively. The respective numbers for breast positioning relative to spine were 7.2 mm (CI: 4.1 – 10.3), 6.4 mm (CI: 4.3 – 8.3) and 4.3 mm (CI: 2.5 – 6.2). Localizing to the sternum/CW as a surrogate for the breast tissue, margins for setup uncertainties were 5.7mm, 5.5mm, and 6.0mm for Breast Board I, 5.0mm, 4.0mm and 4.3mm for Breast Board II, and 3.8mm, 3.5mm and 4.8mm for Breast Board III, in the lateral, anterior/posterior, and superior/inferior directions, respectively. Conclusion: Better patient positioning reproducibility was observed with Boards II and III compared to Board I. Inter- and intra-patient set-up uncertainties were also improved with Boards II and III, which requires smaller PTV margins. Independent of breast board, breast cancer patient positioning to the sternum/CW is a better surrogate than the spine. Our findings have potential dosimetric consequences from set-up uncertainties when employing IMRT or proton treatments, and further analyses are on-going.

60 APPLIED LIFE SCIENCES↗

On-Line Target Position Localization in the Presence of Respiration: A Comparison of two Methods

Purpose: To compare two 'four-dimensional' methods for image-guided target localization in the presence of respiration. Methods and Materials: Four-dimensional image guidance was performed with two methods. A respiration-correlated computed tomography (RCCT) was acquired on a CT simulator, and an average CT (AVG-CT) image was generated from the RCCT. A respiration-correlated cone-beam CT (RC-CBCT) and a free-breathing cone-beam CT (FB-CBCT) were acquired. The 'RCCT method' consisted of calculating the mean target position on both the RCCT and RC-CBCT, registering the RCCT to the RC-CBCT, and determining the shift in the mean target position from the planned mean position. The 'AVG-CT method' consisted of registering the AVG-CT to the FB-CBCT. The ability of each to measure the shift in the mean target position was compared, both in a respiratory phantom and in 8 patients. Results: In phantom, the RCCT and AVG-CT methods were able to measure the true mean target position to within 0.15 cm and 0.10 cm, respectively. In the patient study, the mean error between the methods was 0.13 cm (left-right), 0.14 cm (anterior-posterior), and 0.10 cm (cranio-caudal). The error was not observed to vary with tumor position or magnitude of tumor motion. Conclusions: Respiration may impact the on-line image guidance process. The RCCT method enables localization of the mean tumor position and measurement of changes in the motion pattern, whereas the AVG-CT method is simple, fast, and easily implemented. We found the methods to be nearly equivalent in detecting shifts in the mean tumor position.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Effect of Acoustic Disturbances on the Operation of the Space Shuttle Main Engine Fuel Flowmeter

The Space Shuttle Main Engine (SSME) uses a turbine fuel flowmeter (FFM) in its Low Pressure Fuel Duct (LPFD) to measure liquid hydrogen flowrates during engine operation. The flowmeter is required to provide accurate and robust measurements of flow rates ranging from 10000 to 18000 GPM in an environment contaminated by duct vibration and duct internal acoustic disturbances. Errors exceeding 0.5% can have a significant impact on engine operation and mission completion. The accuracy of each sensor is monitored during hot-fire engine tests on the ground. Flow meters which do not meet requirements are not flown. Among other parameters, the device is screened for a specific behavior in which a small shift in the flow rate reading is registered during a period in which the actual fuel flow as measured by a facility meter does not change. Such behavior has been observed over the years for specific builds of the FFM and must be avoided or limited in magnitude in flight. Various analyses of the recorded data have been made prior to this report in an effort to understand the cause of the phenomenon; however, no conclusive cause for the shift in the instrument behavior has been found. The present report proposes an explanation of the phenomenon based on interactions between acoustic pressure disturbances in the duct and the wakes produced by the FFM flow straightener. Physical insight into the effects of acoustic plane wave disturbances was obtained using a simple analytical model. Based on that model, a series of three-dimensional unsteady viscous flow computational fluid dynamics (CFD) simulations were performed using the MSFC PHANTOM turbomachinery code. The code was customized to allow the FFM rotor speed to change at every time step according to the instantaneous fluid forces on the rotor, that, in turn, are affected by acoustic plane pressure waves propagating through the device. The results of the simulations show the variation in the rotation rate of the flowmeter due to the interaction of the flow straightener wakes and the upstream propagating acoustic waves. A detailed analysis of the acoustic disturbance effects is presented along with an assessment of the impact on measurement accuracy.

Marcu, Bogdan↗

Automatic oscillator frequency control system

A frequency control system makes an initial correction of the frequency of its own timing circuit after comparison against a frequency of known accuracy and then sequentially checks and corrects the frequencies of several voltage controlled local oscillator circuits. The timing circuit initiates the machine cycles of a central processing unit which applies a frequency index to an input register in a modulo-sum frequency divider stage and enables a multiplexer to clock an accumulator register in the divider stage with a cyclical signal derived from the oscillator circuit being checked. Upon expiration of the interval, the processing unit compares the remainder held as the contents of the accumulator against a stored zero error constant and applies an appropriate correction word to a correction stage to shift the frequency of the oscillator being checked. A signal from the accumulator register may be used to drive a phase plane ROM and, with periodic shifts in the applied frequency index, to provide frequency shift keying of the resultant output signal. Interposition of a phase adder between the accumulator register and phase plane ROM permits phase shift keying of the output signal by periodic variation in the value of a phase index applied to one input of the phase adder.

Smith, S. F.↗

Prospective Study of Cone-Beam Computed Tomography Image-Guided Radiotherapy for Prone Accelerated Partial Breast Irradiation

Purpose: To report setup variations during prone accelerated partial breast irradiation (APBI). Methods: New York University (NYU) 07-582 is an institutional review board-approved protocol of cone-beam computed tomography (CBCT) to deliver image-guided ABPI in the prone position. Eligible are postmenopausal women with pT1 breast cancer excised with negative margins and no nodal involvement. A total dose of 30 Gy in five daily fractions of 6 Gy are delivered to the planning target volume (the tumor cavity with 1.5-cm margin) by image-guided radiotherapy. Patients are set up prone, on a dedicated mattress, used for both simulation and treatment. After positioning with skin marks and lasers, CBCTs are performed and the images are registered to the planning CT. The resulting shifts (setup corrections) are recorded in the three principal directions and applied. Portal images are taken for verification. If they differ from the planning digital reconstructed radiographs, the patient is reset, and a new CBCT is taken. Results: 70 consecutive patients have undergone a total of 343 CBCTs: 7 patients had four of five planned CBCTs performed. Seven CBCTs (2%) required to be repeated because of misalignment in the comparison between portal and digital reconstructed radiograph image after the first CBCT. The mean shifts and standard deviations in the anterior-posterior (AP), superior-inferior (SI), and medial-lateral (ML) directions were -0.19 (0.54), -0.02 (0.33), and -0.02 (0.43) cm, respectively. The average root mean squares of the daily shifts were 0.50 (0.28), 0.29 (0.17), and 0.38 (0.20). A conservative margin formula resulted in a recommended margin of 1.26, 0.73, 0.96 cm in the AP, SI, and ML directions. Conclusion: CBCTs confirmed that the NYU prone APBI setup and treatment technique are reproducible, with interfraction variation comparable to those reported for supine setup. The currently applied margin (1.5 cm) adequately compensates for the setup variation detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Setup Variations in Radiotherapy of Anal Cancer: Advantages of Target Volume Reduction Using Image-Guided Radiation Treatment

Purpose: To define setup variations in the radiation treatment (RT) of anal cancer and to report the advantages of image-guided RT (IGRT) in terms of reduction of target volume and treatment-related side effects. Methods and Materials: Twelve consecutive patients with anal cancer treated by combined chemoradiation by use of helical tomotherapy from March 2007 to November 2008 were selected. With patients immobilized and positioned in place, megavoltage computed tomography (MVCT) scans were performed before each treatment and were automatically registered to planning CT scans. Patients were shifted per the registration data and treated. A total of 365 MVCT scans were analyzed. The primary site received a median dose of 55 Gy. To evaluate the potential dosimetric advantage(s) of IGRT, cases were replanned according to Radiation Therapy Oncology Group 0529, with and without adding recommended setup variations from the current study. Results: Significant setup variations were observed throughout the course of RT. The standard deviations for systematic setup correction in the anterior-posterior (AP), lateral, and superior-inferior (SI) directions and roll rotation were 1.1, 3.6, and 3.2 mm, and 0.3 Degree-Sign , respectively. The average random setup variations were 3.8, 5.5, and 2.9 mm, and 0.5 Degree-Sign , respectively. Without daily IGRT, margins of 4.9, 11.1, and 8.5 mm in the AP, lateral, and SI directions would have been needed to ensure that the planning target volume (PTV) received {>=}95% of the prescribed dose. Conversely, daily IGRT required no extra margins on PTV and resulted in a significant reduction of V15 and V45 of intestine and V10 of pelvic bone marrow. Favorable toxicities were observed, except for acute hematologic toxicity. Conclusions: Daily MVCT scans before each treatment can effectively detect setup variations and thereby reduce PTV margins in the treatment of anal cancer. The use of concurrent chemotherapy and IGRT provided favorable toxicities, except for acute hematologic toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Online Correction via Cone-Beam CT-Based Image Guidance for Stereotactic Lung Radiotherapy

Purpose: To evaluate the dosimetric impact of online cone-beam computed tomography (CBCT) guided correction in lung stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty planning and 162 CBCT images from 20 patients undergoing lung SBRT were analyzed. The precorrection CBCT (CBCT after patient setup, no couch correction) was registered to planning CT using soft tissue; couch shift was applied, with a second CBCT for verification (postcorrection CBCT). Targets and normal structures were delineated on CBCTs: gross tumor volume (GTV), clinical target volume (CTV), cord, esophagus, lung, proximal bronchial tree, and aorta. Dose distributions on all organs manifested on each CBCT were compared with those planned on the CT. Results: Without CBCT guided target position correction, target dose reduced with respect to treatment plan. Mean and standard deviation of treatment dose discrepancy from the plan were -3.2% (4.9%), -2.1% (4.4%), -6.1% (10.7%), and -3.5% (7%) for GTV D{sub 99%}, GTV D{sub 95%}, CTV D{sub 99%}, and CTV D{sub 95%}, respectively. With CBCT correction, the results were -0.4% (2.6%), 0.1% (1.7%), -0.3% (4.2%), and 0.5% (3%). Mean and standard deviation of the difference in normal organ maximum dose were 2.2% (6.5%) before correction and 2.4% (5.9%) after correction for esophagus; 6.1% (14.1%) and 3.8% (8.1%) for cord; 3.1% (17.5%) and 6.2% (9.8%) for proximal bronchial tree; and 17.7% (19.5%) and 14.1% (17%) for aorta. Conclusion: Online CBCT guidance improves the accuracy of target dose delivery for lung SBRT. However, treatment dose to normal tissue can vary regardless of the correction. Normal tissues should be considered during target registration, according to target proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subsecond and Submillimeter Resolution Positional Verification for Stereotactic Irradiation of Spinal Lesions

Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shifts between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic image guidance for prostate IMRT using low dose CBCT

Purpose: Varian's On-Board Imager is a linac-integrated cone-beam CT (CBCT) system used at the authors' institution to acquire images prior to delivering each fraction of prostate intensity modulated radiotherapy. The images are used to determine a couch shift that realigns the tumor with the position obtained in the planning CT. However, this manual image-guided radiotherapy (IGRT) technique is operator dependent, time consuming, offers limited degrees of freedom, and requires significant imaging dose over the course of treatment. To overcome these problems, the authors propose two fully automatic IGRT techniques that require significantly less imaging dose. Methods: Dose is reduced by lowering the x-ray tube mA s during CBCT acquisition at the cost of increasing image noise. In ''forward'' IGRT, the CBCT image is automatically registered to the planning CT to obtain the necessary couch shift. The ''reverse'' technique offers additional degrees of freedom as it involves nonrigid registration of the planning CT to the CBCT. Both techniques were evaluated using images of an anthropomorphic phantom with simulated motion and by retrospectively analyzing data from ten prostate cancer patients. Results: IGRT error for the phantom data at 100% relative imaging dose was 8.2{+-}3.7, 3.5{+-}1.2, and 2.1{+-}0.6 mm for setup only, forward, and reverse techniques, respectively. For patient images acquired at 100% relative imaging dose, the errors were 5.4{+-}1.7, 5.0{+-}1.6, 5.0{+-}2.0, and 4.0{+-}1.6 mm for setup only, manual forward (performed clinically), automatic forward, and reverse IGRT, respectively. Furthermore, imaging dose could be reduced to 20% without a significant loss in image guidance accuracy. Conclusions: The presented image guidance methods are accurate while requiring only 20% of the standard imaging dose. The combination of low dose, automation, and accuracy enables frequent corrections during treatment, possibly leading to reduced margins and improved treatment outcomes.

60 APPLIED LIFE SCIENCES↗

Recording of relativistic particles in thin scintillators

Results of investigating an assembly of thin scintillators and silicon photomultipliers for registering relativistic particles with the minimum ionization are presented. A high efficiency of registering relativistic particles using an Ej-212 plastic scintillator, BSF-91A wavelength-shifting fiber (Saint-Gobain), and a silicon photomultiplier (Hamamtsu) is shown. The measurement results are used for creating a scintillation hodoscope of the magnetic spectrometer for registering γ quanta in the GlueX experiment.

Tolstukhin, I A.↗

Vanadium spin qubits as telecom quantum emitters in silicon carbide

Solid-state quantum emitters with spin registers are promising platforms for quantum communication, yet few emit in the narrow telecom band necessary for low-loss fiber networks. Here, we create and isolate near-surface single vanadium dopants in silicon carbide (SiC) with stable and narrow emission in the O band, with brightness allowing cavity-free detection in a wafer-scale material. In vanadium ensembles, we characterize the complex d 1 orbital physics in all five available sites in 4H-SiC and 6H-SiC. The optical transitions are sensitive to mass shifts from local silicon and carbon isotopes, enabling optically resolved nuclear spin registers. Optically detected magnetic resonance in the ground and excited orbital states reveals a variety of hyperfine interactions with the vanadium nuclear spin and clock transitions for quantum memories. Last, we demonstrate coherent quantum control of the spin state. These results provide a path for telecom emitters in the solid state for quantum applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Delamination mechanism study of large size waste printed circuit boards by using dimethylacetamide

Highlights: • Dimethylacetamide (DMA) dissolved the epoxy resin of printed circuit boards (WPCB). • PCBs of 1, 4, 9 and 16 cm{sup 2} were delaminated in 150, 180, 300 and 420 min, respectively. • Peaks of epoxy resin and DMA were evident in the NMR spectra. • Shift in C=O, OH peaks of DMA & resin, respectively was registered w.r.t. time. • Hydrogen bonding between C=O of DMA and OH of resin results in the dissolution. - Abstract: Present work investigates the recycling of waste printed circuit boards (PCBs) by cracking of its multi-layered structure by using dimethylacetamide (DMA). The study shows that cracking and separation of layers of PCBs increases as the temperature increases; and decreases as the surface area of PCBs increases. After separation of layers, the used solvent was analyzed by proton and carbon nuclear magnetic resonance spectroscopy (NMR) to understand the dissolution phenomenon of resin. Further, NMR and Fourier transform infrared spectroscopy analysis of DMA sample after 1 h, 2 h, 3 h, 4 h and 8 h of reaction with PCBs at 433 K and PCB:DMA ratio (wt/vol) of 3:10 has been carried out to investigate the mechanism of dissolution of resin. These studies revealed that hydroxyl group of PCBs polymeric chain participates in hydrogen bonding with parent carbonyl group of DMA molecule that results in the solvation of resin. Possible chemical reaction based on the above finding has been discussed. Using this technique, separation of the metallic fraction without application of any energy intensive mechanical pre-processing is possible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-G-JeP4-14: Assessment of Inter- and Intra-Fractional Motion for Extremity Soft Tissue Sarcoma Patients by Using In-House Real-Time Optical Image-Based Monitoring System

Purpose: This study aimed to assess inter- and intra-fractional motion for extremity Soft Tissue Sarcoma (STS) patients, by using in-house real-time optical image-based monitoring system (ROIMS) with infra-red (IR) external markers. Methods: Inter- and intra-fractional motions for five extremity (1 upper, 4 lower) STS patients received postoperative 3D conformal radiotherapy (3D-CRT) were measured by registering the image acquired by ROIMS with the planning CT image (REG-ROIMS). To compare with the X-ray image-based monitoring, pre- and post-treatment cone beam computed tomography (CBCT) scans were performed once per week and registered with planning CT image as well (REG-CBCT). If the CBCT scan is not feasible due to the large couch shift, AP and LR on-board imager (OBI) images were acquired. The comparison was done by calculating mutual information (MI) of those registered images. Results: The standard deviation (SD) of the inter-fractional motion was 2.6 mm LR, 2.8 mm SI, and 2.0 mm AP, and the SD of the intra-fractional motion was 1.4 mm, 2.1 mm, and 1.3 mm in each axis, respectively. The SD of rotational inter-fractional motion was 0.6° pitch, 0.9° yaw, and 0.8° roll and the SD of rotational intra-fractional motion was 0.4° pitch, 0.9° yaw, and 0.7° roll. The derived averaged MI values were 0.83, 0.92 for REG-CBCT without rotation and REG-ROIMS with rotation, respectively. Conclusion: The in-house real-time optical image-based monitoring system was implemented clinically and confirmed the feasibility to assess inter- and intra-fractional motion for extremity STS patients while the daily basis and real-time CBCT scan is not feasible in clinic.

60 APPLIED LIFE SCIENCES↗

Mobility Behavioral Responses to Transportation Network Companies

This research investigates how an emerging service - transportation network companies (TNCs) - impacts mobility and energy use. Several TNC areas were identified as key factors impacting transportation and energy; including vehicle type, mode shifts, pooling, and deadheading. Using detailed data on individual rides provided by a TNC in Austin Texas, this study quantify the additional vehicle miles traveled (VMT) TNC drivers traveled without passengers (i.e., deadheading) to be 45%, and nearly equaled VMT with passengers. While deadheading increases energy use, vehicles used for ride-hailing tend to be newer, and more fuel efficient (twice as many hybrid-electric vehicles and on average, 3.2 miles per gallon more fuel efficient) than comparable vehicles registered in Austin. Considering deadheading, fuel efficiency, and estimates of passenger pooling and modal shift (from literature), this study suggest that TNCs may increase energy use by 41-90% net compared to baseline pre-TNC personal travel. Preliminary effects of TNC services on vehicle registrations across urban areas may indicate an increase in vehicle registrations of about 1%. However, the effect of TNC entry varies by type of city, ranging from a 3.5% increase to a 0.7% decrease in vehicle registrations. This suggests that ride-hailing may induce demand for vehicle ownership, at least in the short to medium run.

25 ENERGY STORAGE↗

SU-E-J-47: Comparison of Online Image Registrations of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac Imaging Systems

Purpose To compare online image registrations of TrueBeam cone-beam CT (CBCT) and BrainLab ExacTrac imaging systems. Methods Tests were performed on a Varian TrueBeam STx linear accelerator (Version 2.0), which is integrated with a BrainLab ExacTrac imaging system (Version 6.0.5). The study was focused on comparing the online image registrations for translational shifts. A Rando head phantom was placed on treatment couch and immobilized with a BrainLab mask. The phantom was shifted by moving the couch translationally for 8 mm with a step size of 1 mm, in vertical, longitudinal, and lateral directions, respectively. At each location, the phantom was imaged with CBCT and ExacTrac x-ray. CBCT images were registered with TrueBeam and ExacTrac online registration algorithms, respectively. And ExacTrac x-ray image registrations were performed. Shifts calculated from different registrations were compared with nominal couch shifts. Results The averages and ranges of absolute differences between couch shifts and calculated phantom shifts obtained from ExacTrac x-ray registration, ExacTrac CBCT registration with default window, ExaxTrac CBCT registration with adjusted window (bone), Truebeam CBCT registration with bone window, and Truebeam CBCT registration with soft tissue window, were: 0.07 (0.02–0.14), 0.14 (0.01–0.35), 0.12 (0.02–0.28), 0.09 (0–0.20), and 0.06 (0–0.10) mm, in vertical direction; 0.06 (0.01–0.12), 0.27 (0.07–0.57), 0.23 (0.02–0.48), 0.04 (0–0.10), and 0.08 (0– 0.20) mm, in longitudinal direction; 0.05 (0.01–0.21), 0.35 (0.14–0.80), 0.25 (0.01–0.56), 0.19 (0–0.40), and 0.20 (0–0.40) mm, in lateral direction. Conclusion The shifts calculated from ExacTrac x-ray and TrueBeam CBCT registrations were close to each other (the differences between were less than 0.40 mm in any direction), and had better agreements with couch shifts than those from ExacTrac CBCT registrations. There were no significant differences between TrueBeam CBCT registrations using different windows. In ExacTrac CBCT registrations, using bone window led to better agreements than using default window.

60 APPLIED LIFE SCIENCES↗