Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATION COUNTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Study of a Large NaI(T1)Crystal

Using a narrow band positron beam, the response of a large high-resolution NaI(Ti) crystal to an incident positron beam was measured. It was found that nuclear interactions cause the appearance of additional peaks in the low energy tail of the deposited energy spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics of Un doped and Europium-dopedSrI2 Scintillator Detectors

High energy resolution gamma-ray detectors that can be formed into relatively large sizes while operating at room temperature offer many advantages for national security applications. We are working toward that goal through the development of SrI{sub 2}(Eu) scintillator detectors, which routinely provide <;3.0% energy resolution at 662 keV with volumes >;10 cm{sup 3}. In this study, we have tested pure, undoped SrI{sub 2} to gain a better understanding of the scintillation properties and spectroscopic performance achievable without activation. An undoped crystal grown from 99.999% pure SrI{sub 2} pellets was tested for its spectroscopic performance, its light yield, and uniformity of scintillation light collection as a function of gamma-ray interaction position relative to the crystal growth direction. Undoped SrI{sub 2} was found to provide energy resolution of 5.3% at 662 keV, and the light collection nonuniformity varied by only 0.72% over the length of the crystal. Measurements of both a 3% Eu-doped and the undoped SrI{sub 2} crystal were carried out in the SLYNCI facility and indicate differences in their light yield non-proportionality. The surprisingly good scintillation properties of the pure SrI{sub 2} crystal suggests that with high-purity feedstock, further reduction of the Eu concentration can be made to grow larger crystals while not adversely impacting the spectroscopic performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Wavelength-Shifting Fibers for the Mu2e Cosmic Ray Veto Detector

The cosmic-ray-veto detector (CRV) for the Mu2e experiment consists of four layers of plastic scintillating counters read out by silicon photo-multipliers (SiPM) through wavelength-shifting fibers. This paper reports the light properties of several wavelength-shifting fiber samples with diameters of 1.0 mm, 1.4 mm, and 1.8 mm that were considered for the CRV system. A fiber diameter of 1.4 mm was selected as optimal for the CRV, and measurements of the prototype and production fiber of this diameter are presented. Fiber performance was found to exceed the CRV requirements for >99% of the spools. The measurements are performed using a scanner designed to ensure the fiber quality for the CRV.

Dukes, E. C.↗

Track Reconstruction with Cosmic Ray Data at the Tracker Integration Facility

The subsystems of the CMS silicon strip tracker were integrated and commissioned at the Tracker Integration Facility (TIF) in the period from November 2006 to July 2007. As part of the commissioning, large samples of cosmic ray data were recorded under various running conditions in the absence of a magnetic field. Cosmic rays detected by scintillation counters were used to trigger the readout of up to 15\,\% of the final silicon strip detector, and over 4.7~million events were recorded. This document describes the cosmic track reconstruction and presents results on the performance of track and hit reconstruction as from dedicated analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standard Analytical Methods for Pyrolysis Bio-Oils

There has been significant recent interest in the production of renewable fuels and chemicals from biomass and waste feedstocks. Pyrolysis pathways produce a liquid bio-oil product, which must be processed further, or upgraded, to yield fuel or chemical products. Bio-oils are very complex and often unstable samples, and research and development on upgrading processes needs reliable analytical information. In particular, chemical characterization techniques are needed to quantify both functional groups and individual compounds present in bio-oils. Reliable analytics are also needed to enable the bioenergy industry, as industrial facilities often have different analytical needs and capabilities than research facilities. In this presentation, we will discuss the development of a suite of standard analytical methods for pyrolysis bio-oils. Analytical methods to be discussed include: Determination of Carbon, Hydrogen, Nitrogen, and Oxygen in bio-oils; Accelerated Aging of Fast Pyrolysis Bio-oil using Carbonyl Titration; Determination of Water Content in Bio-oils by Volumetric Karl Fischer Titration; Determination of Carbon Functional Groups; Elemental Analysis of Bio-oils by Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) - Na, K, Mg, Ca, S, P, and Fe; Determination of Phenolic Groups in Bio-oils using Revised Folin-Ciocalteu Methods: Single Cuvette and Plate Reader; Corrosivity of Bio-oils: Screening Test using Metal Leaching; Determination of Biogenic Content by 14C Measurement using Liquid Scintillation Counter. These new analytical methods are publicly available as Laboratory Analytical Procedures (https://www.nrel.gov/bioenergy/bio-oil-analysis.html), along with previously developed standard methods: GC-MS, Acid Titration, Carbonyl Titration, and 31P NMR. Additionally, the development of diffusion ordered NMR for characterization of bio-oil molecular weight will be discussed. Collectively, this suite of analytical methods represents the most comprehensive set of standard methods available for pyrolysis bio-oils. These standard methods are commonly used by the bioenergy community, and provide reliable information that enables research, scaleup, and industrial processing of biomass to produce renewable fuels and chemicals.

analytical↗

A technique for synthesizing metal tritide standards

Before surplus plutonium pits can be decommissioned and converted into metal oxides to be used as reactor fuels, residual tritium must be reduced to an acceptable level. We have developed two analytical methods involving melting and acid dissolution, combined with liquid scintillation counting as a quantitative and sensitive technique for measuring residual tritium in Pu metal. The detection limit, linearity, and reproducibility of these analytical methods must be validated with a series of metal tritide standards. Since there are no commercially available metal tritide standards, we have developed a technique for their synthesis. The synthesis of these low-level metal tritide standards is accomplished by charging cerium powder with a known amount of tritium to form a master cerium tritide alloy and then by aliquoting from this master alloy and diluting with pure cerium powder to form a series of standards with different tritium concentrations. The major difficulty in synthesizing these standards is that the samples contain extremely low levels of tritium, which span over three decades of concentrations. The synthesis technique and initial data obtained for cerium hydride samples will be presented. (authors)

36 MATERIALS SCIENCE↗

Cryogenic readout techniques for germanium detectors

High Purity Germanium detectors are used in many applications, from nuclear and astro-particle physics, to homeland security or environment protection. Although quite standard configurations are often used, with cryostats, charge sensitive amplifiers and analog or digital acquisition systems all commercially available, it might be the case that a few specific applications, e.g. satellites, portable devices, cryogenic physics experiments, etc. also require the development of a few additional or complementary techniques. An interesting case is for sure GERDA, the Germanium Detector Array experiment, searching for neutrino-less double beta decay of {sup 76}Ge at the Gran Sasso National Laboratory of INFN - Italy. In GERDA the entire detector array, composed of semi-coaxial and BEGe naked crystals, is operated suspended inside a cryostat filled with liquid argon, that acts not only as cooling medium and but also as an active shield, thanks to its scintillation properties. These peculiar circumstances, together with the additional requirement of a very low radioactive background from all the materials adjacent to the detectors, clearly introduce significant constraints on the design of the Ge front-end readout electronics. All the Ge readout solutions developed within the framework of the GERDA collaboration, for both Phase I and Phase II, will be briefly reviewed, with their relative strength and weakness compared together and with respect to ideal Ge readout. Finally, the digital processing techniques developed by the GERDA collaboration for energy estimation of Ge detector signals will be recalled. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the Fast Neutron Response for {sup 4}He Scintillation Detectors Using a Coincidence Scattering Method

Previous work has measured the neutron response of pressurized {sup 4}He scintillation detectors, however these studies only examine the response as a function of incident neutron energy. Since the detection mechanism in {sup 4}He detectors is elastic scattering, and the interacting neutron will only deposit a fraction of its incident kinetic energy in the detector gas, an examination of the response of the detector output to deposited energy is necessary to transform these detectors into instruments for neutron spectrometry. Using a combined time-of-flight (TOF) and coincidence scattering method, this paper further characterizes the {sup 4}He light response to fast neutrons by examining the scintillation light yield as a function of deposited energy, measuring the light response up to 5 MeV. These {sup 4}He detectors are simple in design, and are manufactured by Arktis Radiation Detectors in several sizes. The specific model used in this experiment had an active volume 20 cm long with an inner diameter of 4.4 cm, giving a total active volume of 304 cm{sup 3}. The key components include the active volume, filled with 150 bar of helium-4 gas, and photomultiplier tubes (PMTs) mounted at either end of the active volume. The detector body is made of stainless steel. The detector response was experimentally measured using a two-detector coincidence arrangement with a {sup 252}Cf source. Two {sup 4}He detectors were vertically mounted, and the source was placed at a horizontal distance from the center of the bottom detector, forming a right angle. By requiring coincidence between the two detectors, it was confirmed that each neutron interacting in the second (top) detector must first have undergone a scattering interaction in the first (bottom) detector, and the time-of-flight (TOF) technique could then be used to determine the energy of the neutron as it traveled between the two detectors by the difference in time between the two detector events. More importantly, with the scattering angle known, the amount of energy deposited by the neutron in the bottom detector (ER) was also calculated using kinematic scattering equations. This deposited recoil energy was then compared to the corresponding light output for each event to form a deposited energy scintillation light response matrix. Similarly, the system's insensitivity to gammas and its ability to reject gammas by pulse shape discrimination (PSD) are often cited as an important advantage, although a detailed analysis of these capabilities has not yet been performed. This work therefore quantified these parameters in order to further characterize these detectors for future mixed radiation field measurements. Gamma sources were measured spanning a range of gamma-ray energies from 0.122 MeV to 1.332 MeV, including {sup 57}Co, {sup 137}Cs, {sup 54}Mn, and {sup 60}Co. Each source was counted by the {sup 4}He detector and the background subtracted. Taking the ratio of the number of events detected during the experimental source measurement to the number of gammas predicted by MCNPX to pass through the detector volume yields the detector's intrinsic gamma efficiency. The difference between this fraction and unity is therefore a measure of the detector's ability to ignore interfering gamma rays, defined as its inherent gamma rejection rate. The ability of post-processing PSD algorithms to further reduce the number of gammas is also investigated and quantified. Finally, it has been noted that the scintillation signal from a single neutron event can be separated in time into two components: the fast component is a sharp peak that exists on the order of nanoseconds; the slow component is a series of smaller pulses, stretched out over four microseconds. Whereas previous research has exclusively focused on the energy information contained in the slow component, this work demonstrates that the fast component is also sensitive to neutron energy, and the entire scintillation signal can therefore be used. In conclusion, the relationship of fast neutron {sup 4}He scintillation detectors to deposited neutron energy was explored, and will be combined with previous works that measured the scintillation response to incident neutron energy in order to develop a neutron spectrometer. Similarly, the ability of these {sup 4}He detectors to reject interfering gamma rays was also quantified, and so will enable this spectrometer to be deployed in mixed radiation field measurements. Finally, while previous works with these detectors have focused on an analysis of the slow scintillation component, it was demonstrated in this work that the fast component also contains significant energy information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mu2e - Research & Development

Current efforts are being conducted at Fermi National Laboratory to study potential violations in accepted theory that would otherwise suggest a restructuring of our fundamental understanding of the universe. Mu2e is one of these frontier projects that studies Charged Lepton Flavor Violation (CLFV) which if observed, would suggest physics beyond the Standard Model. Therefore, this note encompasses several projects that contribute to the fruition of Mu2e investigations. Due to the broad range of disciplinary inconsistencies that each project requires, all the work is being presented as a means of justifying contribution to Mu2e. The projects are comprised of a simulation exploring the extinction level of proton pulses after Recycler ring re-bunching by using G4beamline to simulate an 8GeV proton beam interaction with a titanium target, three Cherenkov radiation-based detectors and 2/3-fold and 3/3-fold coincidence rate analysis. Additionally, supplemental work for the implementation of a Micro Telecommunications Computing Architecture (TCA) crate to establish a peak finding algorithm to ensure that the out-of-time beam is less than 10$^{−10}$ fractional level along with single-layer inefficiency analysis on scintillation counters for the Cosmic-Ray Veto (CRV) analysis to ensure the overall inefficiency is 10$^{−4}$. Preliminary results have been achieved for the G4beamline simulation 2/3-fold and 3/3-fold coincidences which are in the order of 10$^{−9}$ and 10$^{−10}$, respectively. Only preliminary results of a triangular counter and four rectangular di-counters for the CRV have been realized. The microTCA crate development is still ongoing.

43 PARTICLE ACCELERATORS↗

CeBr3 as a High-Resolution Gamma-Ray Detector

Lanthanum halide (LaBr3:Ce) scintillators have been well-documented as high-resolution gamma-ray detectors that are operated at room temperature. These scintillators have better resolution (<3% at 662 keV) relative to sodium iodide (NaI(Tl)) scintillators (7% at 662 keV), but the naturally occurring radioactive isotope 138La causes self-activity in the crystal that occludes portions of the gamma-ray spectrum. This selfactivity limits the use of LaBr3:Ce in high-sensitivity applications. Cerium, the dopant in the LaBr3:Ce matrix possesses useful scintillation properties, and its selfactivity is on the order of 3750 times less than La; however, Ce has not been fully characterized as the chief component in a scintillation detector. This work investigated Ce as the key scintillation matrix component in a scintillation detector with the hypothesis that CeBr3 promises energy resolution comparable or superior to LaBr3:Ce. The researchers involved with this work believe that CeBr3 may be the answer to obtaining high-temperature, high-resolution spectra with greater sensitivity than LaBr3:Ce.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

Wagner, L. J.↗

Large scale anisotropy of UHECRs for the Telescope Array

The origin of Ultra High Energy Cosmic Rays (UHECRs) is one of the most interesting questions in astroparticle physics. Despite of the efforts by other previous measurements, there is no consensus of both of the origin and the mechanism of UHECRs generation and propagation yet. In this context, Telescope Array (TA) experiment is expected to play an important role as the largest detector in the northern hemisphere which consists of an array of surface particle detectors (SDs) and fluorescence detectors (FDs) and other important calibration devices. We searched for large scale anisotropy using SD data of TA. UHECRs are expected to be restricted in GZK horizon when the composition of UHECRs is proton, so the observed arrival directions are expected to exhibit local large scale anisotropy if UHECR sources are some astrophysical objects. We used the SD data set from 11 May 2008 to 7 September 2010 to search for large-scale anisotropy. The discrimination power between LSS and isotropy is not enough yet, but the statistics in TA is expected to discriminate between those in about 95% confidence level on average in near future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A broad band X-ray imaging spectrophotometer for astrophysical studies

A broadband X-ray imaging spectrophotometer (BBXRIS) has been built for astrophysical studies. The BBXRIS is based on a large-imaging gas scintillation proportional counter (LIGSPC), a combination of a gas scintillation proportional counter and a multiwire proportional counter, which achieves 8 percent (FWHM) energy resolution and 1.5-mm (FWHM) spatial resolution at 5.9 keV. The LIGSPC can be integrated with a grazing incidence mirror and a coded aperture mask to provide imaging over a broad range of X-ray energies. The results of tests involving the LIGSPC and a coded aperture mask are presented, and possible applications of the BBXRIS are discussed.

Lum, Kenneth S. K.↗

Toward a Real-Time In Vivo Dosimetry System Using Plastic Scintillation Detectors

Purpose: In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. Methods and Materials: The PSDs were built with a dose-sensitive volume of 0.4 mm{sup 3}. The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of <0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. Results: The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. Conclusion: Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single crystal chemical vapor deposited diamond detectors for intensity-modulated radiation therapy applications

We report here on first intensity-modulated radiation therapy (IMRT) clinical tests performed at the Gustave Roussy Institute in France using one small (0.117 mm{sup 3}) synthetic single crystal diamond detector (SCDD). We report the comparison between the point doses evaluated with our detector, with a PTW semiflex air ionization chamber (0.125 cm{sup 3}) and calculated with the treatment planning system (TPS), respectively. The obtained results show a maximum difference of 2.3% for the diamond detector and of 4.6% for the ionization chamber, as compared with the TPS calculations. These very promising results show the potentiality of chemical vapor deposited SCDD for dosimetry of IMRT fields and opens up the field for diamond dosimeters toward novel applications such as very small beam monitoring.

36 MATERIALS SCIENCE↗

Indoor And Outdoor Gamma Dose Measurements For Specific Counties of Trabzon-Turkey

In this study, it was determined environmental gamma radiation dose rate for some counties of Trabzon-Turkey. A detailed ambient gamma dose measurement has been performed in the seven counties of Trabzon, using a portable environmental survey meter (NaI detector, INSPECTOR 1000). The measurements were performed indoor and outdoor of buildings and also at each spot, a reading was taken at 1 m above ground level. The dose rates varied from 42.69 nGy/h and 140.91 nGy/h for indoor gamma dose and 27.84 nGy/h and 121.80 nGy/h for outdoor gamma dose . Average indoor and outdoor gamma dose rates were ascertained to be 71.05 nGy/h and 60.20 nGy/h, respectively. The annual effective doses were calculated from indoor and outdoor gamma doses to be 348.56 muSv/y and 73.83 muSv/y, respectively.

54 ENVIRONMENTAL SCIENCES↗

Study of the {sup 15}N(p,gamma){sup 16}O reaction at the LUNA accelerator with a gas target setup

The {sup 15}N(p,gamma){sup 16}O reaction links the CN cycle to the NO cycle allowing for the production of the oxygen and fluorine isotopes during the hydrogen burning in novae and AGB stars. This reaction has been intensively studied by the LUNA collaboration.In this contribution the experiment performed using a BGO detector and a windowless gas target setup is described. The measurement of the astrophysical S-factor has been done in the center of mass energy range from 90 keV to 230 keV. The cross section is found to be a factor two lower than previously believed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laboratory background of an escape-suppressed Clover gamma-ray detector overground, shallow underground, and deep underground

This study presents the laboratory background measurement of a Clover-type composite gamma-detector equipped with a BGO escape-suppression shield. Recently, such a detector had been used in an in-beam gamma-spectroscopy measurement of the {sup 14}N(p,gamma){sup 15}O reaction deep underground. Here the laboratory gamma-ray background of that detector is studied in three different environments: overground, in a shallow underground laboratory and deep underground. In addition, the effect of the escape-suppression shield on the cosmic-ray induced background has been studied in all three cases. The measurements have been performed at LUNA site in the Gran Sasso National Laboratory, Assergi, Italy (deep underground), at the Felsenkeller Laboratory, Dresden, Germany (shallow underground) and ATOMKI, Debrecen, Hungary (Earth's surface).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗