Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

GIS-Based Modeling of Contaminated Soil Volumes at Multiple Sites in the Formerly Utilized Sites Remedial Action Program - 20149

The remediation of hazardous, toxic, and radioactive waste (HTRW) sites produces cost-related risks associated with the estimation of contaminated soil or debris volumes. Historical risk-management techniques include cost contingencies to cover volume uncertainties that affect project budgeting and decision-making. The Buffalo District teamed with project partners to lessen volume uncertainty and reduce project risks at multiple HTRW sites managed under the Formerly Utilized Sites Remedial Action Program (FUSRAP). Historical remedial investigations under FUSRAP commonly identified the presence of radiological material in site media, the associated human health risk, and then areas of remediation. To manage remedial execution and reduce risk, pre-design or remediation-phase sampling essentially 'chased' contamination, which was not conducive to efficient predictive budgeting derived from Feasibility Study (FS) cost analyses. The Buffalo District first optimized their approach to better understand volume uncertainty by utilizing the Argonne National Laboratory's Bayesian Approaches for Adaptive Spatial Sampling (BAASS) software [1]. BAASS processed soft data (e.g., gamma walk-over data) and spatial sampling data to estimate the lateral extent of contaminated soil irrespective of depth (i.e., gross contamination extent) and define areas of contaminant uncertainty. The software performed a binary transformation of contaminant concentrations at all sampling points based upon remedial action goals or a sum of ratios approach (i.e., clean, impacted, or range of impacts in soil). The model produced two-dimensional (horizontal) contaminant probability contours and statistical uncertainty in the sampling coverage and resulting contaminant extents. This method was translated vertically by partitioning the sampling data into depth brackets that produced a stacked representation of contaminant extents and uncertainty in the subsurface (i.e., similar to construction lifts). The results commonly led to a better understanding of project uncertainty and the need for sampling strategies that produce high-confidence soil volumes, which control costs. The BAASS-based delineations were eventually replaced by Empirical Bayesian Kriging (EBK) methods available in ArcGIS Spatial or 3D Analysts [2]. The EBK method calculates contaminant probability zones derived from user-controlled semivariograms of the spatial datasets. The resulting probability zones (e.g., 50% or 80% of contaminant probability) represent the two-dimensional surface delineation of the overall horizontal remedial area, similarly to BAASS. However, unlike BAASS, the vertical sampling data within these probability zones became vertical control points to contour a subterranean surface that connects subsurface points to the land-surface delineations of contamination. The resulting representation of horizontal and vertical impacts within an enclosed envelop (volume) of soil included uncertainty distributions that are used to plan uncertainty-reduction sampling. These data-driven and math-based models of three-dimensional sampling results produced well-bounded remedial volumes for project planning and better uncertainty predictions during project budgeting. The EBK method was applied to several FUSRAP sites managed by the Buffalo District and compared to less rigorously modeled sites previously remediated by the District. The comparison of modeled to actual remediated volumes provide a basis for validating the volume-estimation method. This comparison is important to ensure modeled volumes match physical boundaries of site remediation. FUSRAP sites with denser investigative sampling and lesser volume uncertainty proved useful in remedial planning and contracting. The Buffalo District noted that historical sites with sparser sampling arrays had greater disparity between estimated volumes and final remedial volumes. The benefit achieved over the cost of detailed soil sampling appears positive for FUSRAP projects, especially where impacts vary widely and appear unbounded by investigation-phase sampling. The subsequent Empirical Bayesian Kriging of contamination coupled with vertical contouring for soil estimations reduces uncertainty in soil volumes or indicates where sampling is required to reduce uncertainty, which together optimize remedial planning and budgeting. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Robotic servicing system for space material experiment

A containerless image furnace with an electrostatic positioning device has been developed as one of the material experiment facilities on the Japanese experimental module (JEM). It is characterized by heating/melting/cooling the sample whose position is kept without any contacts by actively controlled electrostatic force exerted between the sample and a set of electrodes. The experiment using the image furnace requires various servicing operations. We have been developing a robotic servicing system with an internal robot accommodated in the rack as an alternative to the crew. It aims to reduce the load on the crew by automating regular tasks and to increase the flexibility applicable to simple irregular tasks by introducing a remote teleoperation scheme. The present robot has poor capability to replace the crew. In order to compensate it, introducing of the concept of the robot friendliness and improving the controllability of the teleoperation by the ground operator aids are essential. In this paper, we identify the tasks to be performed by the robotic servicing system and discuss the way to compensate the capability of the robot. In addition we describe the evaluation tests using an experimental model.

Yamawaki, Toshihiko↗

Holographic thin film analyzer

A system for the analysis and measurement of thin films in which the light output of a laser is split into two beams is discribed. The first beam is focused to illuminate the entire area of a photographic plate and the second beam is colummated and directed through a relatively small portion of the photographic plate onto the sample with the film to be observed. The surface of the sample is positioned at a slight angle with respect to a plane normal to the second beam and the light reflected from the sample arrives back at the photographic plate in a region other than through which the second beam originally passes. By making two successive exposures during the deposition of material on the surface of the sample, holograms are recorded on the photographic plate. The plate is then developed and interference lines of the hologram provide a measurement of the film or material deposited between exposure.

Williams, J. R.↗

Volatiles in melt inclusions from lunar mare basalts: Bridging the gap in the H 2 O/Ce ratio between melt Inclusions in lunar pyroclastic sample 74220 and other mare samples

The H2O concentration and H 2 O/Ce ratio in olivine-hosted melt inclusions are high in lunar pyroclastic sample 74220 (H 2 O up to 1410 ppmw; H 2 O/Ce up to 77) but lower (H2O 10 to 430 ppmw; H 2 O/Ce 0.3 to 9.4) in all other lunar samples studied before this work. The difference in H 2 O concentration and in H 2 O/Ce ratio is absent for other volatile elements (F, S, and Cl) in melt inclusions in 74220 and other lunar samples. Because H 2 O (or H) is a critical volatile component with significant ramifications on the origin and evolution of the Moon, it is important to understand what causes such a large gap in H 2 O/Ce ratio between 74220 and other lunar samples. Two explanations have been advanced. One is that volcanic product in sample 74220 has the highest cooling rate and thus best preserved H 2 O in melt inclusions compared to melt inclusions in other samples. The other explanation is that sample 74220 comes from a localized heterogeneity enriched in some volatiles. To distinguish these two possibilities, here we present new data from two rapidly cooled lunar samples with glassy melt inclusions: olivine-hosted melt inclusions (OHMIs) in 79135 regolith breccia (unknown cooling rate but with glassy MIs similar in texture with those in 74220), and pyroxene-hosted melt inclusions (PHMIs) in 15597 pigeonite basalts (known high cooling rate, second only to 74220 and 15421). In addition, we also investigated new OHMIs in sample 74220. If the gap is due to the difference in cooling rates, samples with cooling rates between those of 74220 and other studied lunar samples should have preserved intermediate H2O concentrations and H 2 O/Ce ratios. Our results show that melt inclusions in 79135 and 15597 contain high H 2 O concentrations (up to 969 ppmw in 79135 and up to 793 ppmw in 15597) and high H 2 O/Ce ratios (up to 21 in 79135 and up to 13 in 15997), bridging the big gap in H 2 O/Ce ratio among 74220 and other lunar samples. Combined with literature data, we confirm that H 2 O/Ce ratios of different lunar samples are positively correlated to the cooling rates and independent of the type of mare basalts. We hence reinforce the interpretation that the lunar sample with the highest cooling rate best represents pre-eruptive volatiles in lunar basalts due to the least degassing. Based on Ce concentration in the primitive lunar mantle, we estimate that H 2 O concentration in the primitive lunar mantle (meaning bulk silicate Moon) is 121 ± 15 ppmw. Our new data also further constrain F/P, S/Dy and Cl/Ba ratios in lunar basalts and the lunar mantle. Estimated F, P, and S concentrations in the lunar primitive mantle are 4.4 ± 1.1 ppmw, 22 ± 8 ppmw, and 67 +67 −33 ppmw, respectively.

Xue Su↗

Health significance and occurrence of injured bacteria in drinking water

Enteropathogenic and indicator bacteria become injured in drinking water with exposure to sublethal levels of various biological, chemical and physical factors. One manifestation of this injury is the inability to grow and form colonies on selective media containing surfactants. The resulting underestimation of indicator bacteria can lead to a false estimation of water potability. m-T7 medium was developed specifically for the recovery of injured coliforms (both "total" and fecal) in drinking water. The m-T7 method was used to survey operating drinking water treatment and distribution systems for the presence of injured coliforms that were undetected with currently used media. The mean recovery with m-Endo LES medium was less than 1/100 ml while it ranged between 6 and 68/100ml with m-T7 agar. The majority of samples giving positive results with m-T7 medium yielded no detectable coliforms with m-Endo LES agar. Over 95% of the coliform bacteria in these samples were injured. Laboratory experiments were also done to ascribe the virulence of injured waterborne pathogens. Enteropathogens including Salmonella typhimurium, Yersinia enterocolitica and Shigella spp. required up to 20 times the chlorine levels to produce the same injury in enterotoxigenic Escherichia coli (ETEC) and nonpathogenic coliforms. Similar results were seen with Y. enterocolitica exposed to copper. The recovery of ETEC was followed by delayed enterotoxin production, both in vitro and in the gut of experimental animals. This indicates that injured waterborne enteropathogenic bacteria can be virulent.

NASA Discipline Number 13-40↗

Interactions of cesium and barium ions with calcium silicate hydrate under the condition saturated with saline water - 15247

The interaction of cesium (Cs) and barium (Ba) ions with calcium silicate hydrate (CSH gel) without drying processes was examined under the condition saturated with saline water, by monitoring the concentrations of Cs and Ba and using the Raman spectroscopy and the zeta potential. In the experiments, Ca/Si molar ratios of CSH gel were set to 0.4, 0.8, 1.2 and 1.6. Each sample was synthesized with CaO powder, SiO{sub 2} powder and NaCl solution in given combinations. The concentration of NaCl solution was set to 0.006, 0.06 and 0.6 M. At the same time, CsCl or BaCl{sub 2} solution was added to the sample in order to adjust its concentration to 1.0 mM. The curing period was set to 7, 14, 30 days. As a results, the sorption of Cs and Ba ions on CSH gel became stronger with lower Ca/Si molar ratio. On the other hand, even though the zeta potential showed the surface charge of higher Ca/Si ratio samples was positive charge which inhibits the sorption of cations, Cs and Ba ions significantly sorbed on CSH gel. In addition, Raman spectra of higher Ca/Si ratio samples showed that the degree of depolymerization of silicate chain increased with the sorption of Cs and Ba ions on CSH gel. In other words, even in higher Ca/Si ratio samples, Cs and Ba ions can sorb on CSH gel through the structural deformation of CSH gel. These results suggest that CSH gel might be able to contribute the migration retardation of Cs and/or Ba ions through the interaction with CSH gel, even if the near-field of the geological repository are saturated by saline groundwater. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic sample Dewar for MX beam-line

It is very common for crystals of large biological macromolecules to show considerable variation in quality of their diffraction. In order to increase the number of samples that are tested for diffraction quality before any full data collections at the ESRF*, an automatic sample Dewar has been implemented. Conception and performances of the Dewar are reported in this paper. The automatic sample Dewar has 240 samples capability with automatic loading/unloading ports. The storing Dewar is capable to work with robots and it can be integrated in a full automatic MX** beam-line. The samples are positioned in the front of the loading/unloading ports with and automatic rotating plate. A view port has been implemented for data matrix camera reading on each sample loaded in the Dewar. At last, the Dewar is insulated with polyurethane foam that keeps the liquid nitrogen consumption below 1.6 L/h. At last, the static insulation also makes vacuum equipment and maintenance unnecessary. This Dewar will be useful for increasing the number of samples tested in synchrotrons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electrodynamic and hydrodynamic phenomena in magnetically-levitated molten droplets. II - Transient behavior and heat transfer considerations

Computed results are presented describing the transient evolution of the velocity and the temperature fields in a levitation-melted, electromagnetically-positioned metallic sample under microgravity, for conditions, when the heating current is switched off. Thus the calculations trace the evolution from one steady state corresponding to the simultaneous operation of both the heating and the positioning coils to that corresponding to the operation of the positioning coils only. The calculations have shown that the velocity field will decay much more rapidly than the temperature field, so that the cooling and subsequent undercooling and recalescence of the samples should take place from an essentially stagnant melt, meeting the original objectives of the experiment. The computed results for the velocity decay appear to agree with asymptotic calculations and also appear to follow the scaling laws.

Zong, Jin-Ho↗

Interference with negative particle sampling due to formation of positive ions in a quadrupole mass spectrometer

A quadrupole mass spectrometer has been utilized to study active discharges containing Cs vapor. Production of positive ions by electron impact within the mass spectrometer and subsequent secondary electron emission from cesiated surfaces produced spurious or pseudonegative ion signals which interfered with attempts to sample negative ions from the plasma. These effects may also occur in other gas discharge systems.

Kuehn, D. G.↗

Triple containment targets for particle irradiation

The invention provides a system for containing irradiated particles, the system having a housing having a closed upstream end and an open downstream end; an axially disposed tunnel extending from the downstream end to the upstream end, wherein longitudinally extending regions of the tunnel define a plurality of threaded surfaces; a sample cup positioned within the tunnel and proximal to the closed upstream end; threaded plugs matingly received by the threaded surfaces so as to provide at least one seal between the sample cup and the atmosphere external of the housing; and a plurality of deformable substrates disposed between the plugs.

Smith, Nicholas A.↗

Impact of Standing Bleed Water on Saltstone Placement

The amount of water present during placement and subsequent curing of saltstone has the potential to impact several properties important for grout quality. An active drain water system can remove residual standing water and expose the surface of the placed saltstone to air. Oxidation of the saltstone may result in an increase in the leachability of redox sensitive elements. A dry surface can lead to cracking, causing an increase in hydraulic conductivity. An inactive drain water system can allow standing water that generates unnecessary hydrostatic head on the vault walls. Standing water that cannot be removed via the drain system will be available for potential incorporation into subsequent grout placements. The objective of this work is to study the impact of standing water on grout quality pertaining to disposal units. A series of saltstone mixes were prepared, and cured at ambient temperature to evaluate the impact of standing water on saltstone placement. The samples were managed to control drying effects on leachability by either exposing or capping the samples. The water to premix ratio was varied to represent a range of processing conditions. Samples were analyzed for density, leachability, and hydraulic conductivity. A monolith of each composition was cut into four sections to analyze the homogeneity of the sample with respect to vertical position within the sample. The density of each section was measured by two methods, helium pycnometry and by ASTM 642-06. The results show a trend of increasing density with increasing depth in the samples. This effect is more pronounced with the inclusion of excess bleed water and indicative of increased settling. The leachability of the eight different samples was analyzed by ANS/ANSI 16.1 method. These results indicate that drying of the saltstone during curing leads to decreased Leachability Indices (indicative of more release) for potassium, sodium, rhenium, nitrite, and nitrate. This may be caused by shrinkage cracking in the samples creating additional pathways for contaminant release. There was no noticeable effect on leachability by changing the water to premix ratio or by including excess bleed water. There was no detectable chromium release in any of the samples. Chromium and rhenium were added in equal amounts to determine whether rhenium might be an acceptable surrogate for chromium, a hazardous material. This testing shows no correlation between the behavior of the two elements, as chromium is not released at detectable levels and rhenium is released at a comparable rate to nitrate, the most prevalent and mobile species in saltstone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of the Pairwise Kinematic Sunyaev-Zel'dovich Effect with BOSS DR11 and the Atacama Cosmology Telescope

We present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

De Bernardis, F.↗

Method and system for laser-based formation of micro-shapes in surfaces of optical elements

A method of forming a surface feature extending into a sample includes providing a laser operable to emit an output beam and modulating the output beam to form a pulse train having a plurality of pulses. The method also includes a) directing the pulse train along an optical path intersecting an exposed portion of the sample at a position i and b) focusing a first portion of the plurality of pulses to impinge on the sample at the position i. Each of the plurality of pulses is characterized by a spot size at the sample. The method further includes c) ablating at least a portion of the sample at the position i to form a portion of the surface feature and d) incrementing counter i. The method includes e) repeating steps a) through d) to form the surface feature. The sample is free of a rim surrounding the surface feature.

36 MATERIALS SCIENCE↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrated ‘omics analysis for studying the microbial community response to a pH perturbation of a cellulose-degrading bioreactor culture

Propionate accumulation is a common indicator of process imbalances in anaerobic bioreactor systems. The accumulation of propionate can occur due to low retention rates, hydrogen accumulation, or mechanical changes affecting the proximity between propionate oxidizers and partner species, thereby preventing necessary electron transfer. Few studies, however, have observed the changes in microbial community structure during propionate accumulation. We used 454 pyrosequencing of 16S rDNA to evaluate the community membership during propionate accumulations in replicate bioreactors with rumen based cultures. Half of the culture volume from a parent reactor was transferred to a sterile “daughter” reactor, and both systems were run identically. Both reactors experienced a propionate accumulation after roughly 10 days, with the propionate accumulation being less pronounced in the parent reactor as compared to the daughter reactor. Non-metric multidimensional scaling (NMDS) was used to determine clustering patterns of the samples, and correlative methods were used to determine which OTUs were significantly associated with the movements of samples along the NMDS axes. The presence of Saccharofermentans characterized the position of early samples, whereas the presence of Ruminococcus and Succiniclasticum were more indicative of the positions of later samples. Hydrogen accumulation and low sequence counts indicated low methanogen activity. Although both reactor systems were closed to microbial inputs due to the sterilization of influent media, we recorded significant increases in reactor diversity over time. This suggests that changes in the abundances of dominant community members may affect the sequencing of rare taxa within samples.

59 BASIC BIOLOGICAL SCIENCES↗

Accumulation of trace elements in soil and fauna within a site historically contaminated with coal combustion residues

Legacy contaminants tied to energy production are a worldwide concern. Coal combustion residues (CCRs) contain high concentrations of potentially toxic trace elements such as arsenic (As), mercury (Hg), and selenium (Se), which can persist for decades after initial contamination. Coal combustion residue disposal methods, including aquatic settling basins and landfills, can facilitate environmental exposure through intentional and accidental releases. Wildlife exposed to CCRs can experience numerous deleterious effects, such as on development, reproduction, and survival. In the current study, we quantified and compared concentrations of As, Hg, Se, and strontium (Sr) within soils and target fauna (three vertebrate and three invertebrate taxa) from a CCR-contaminated site and a reference site within the U.S. Department of Energy’s Savannah River Site, South Carolina, United States. Our objectives were to (1) compare current concentrations of tested elements in soil and resident fauna to levels from our reference site, (2) assess natural attenuation of elements in soils by comparing current concentrations to historic levels, and (3) evaluate the biomagnification potential of the elements measured via body burden and trophic position correlations among fauna. Here, element concentrations were higher in contaminated soils than reference soils; however, concentrations in 2022 were unchanged from concentrations measured in 2003, suggesting no natural attenuation of tested elements. Additionally, target fauna had elevated As, Se, and Sr levels in comparison to reference samples. A positive correlation was observed in southern toads between Sr concentrations and trophic position, as assessed by nitrogen stable isotope ratios, suggesting potential for biomagnification of Sr within our study system. Collectively, our results demonstrate that legacy contaminants are still present and bioaccumulate in a diversity of taxa in a CCR-contaminated site that has not received effluents in more than 50 years, suggesting monitoring programs in CCR-contaminated sites should be maintained long term in the absence of remediation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The Effects of Radiation and Emitted Light Transport on the Positional Response of 11 cm × 42.5 cm × 5.5 cm NaI(Tl) Detectors

Experiments were performed with 30 11 cm x 42.5 x cm 5.5 cm NaI(Tl) detectors to better understand their positional response. Spectra were collected using 0.02 to 0.15 MBq point sources of 241 Am, 137 Cs, 60 Co, and 133 Ba positioned on lines parallel and perpendicular to the long axis of the crystal along both the narrow and wide detector faces as well as at different distances from them. A greater density of positions was sampled at the ends of the detector, and repeated measurements were made to examine potential gain drifts during the experiment. Spectroscopic peak counts, spectroscopic pulse heights, and net counts were analyzed. Empirical equations were fit to the aforementioned data for each specific source energy as a function of source position. In addition, a Monte Carlo radiation transport code was used to simulate the expected positionally variable response based solely upon radiation absorption. The simulated radiation transport efficiency functions were compared to the experimental data. The effects of the geometric radiation efficiency, the attenuation and scattering of emitted light within the scintillation crystal, and combined effects such as non-uniformity of the photomultiplier tube photocathode response and crystal irregularities were then distinguished. Functions describing each effect were derived. The results suggest potential new corrections to data obtained with large scintillation detectors as well as a novel approach to partial positional gamma-ray detection with minimal collimation, given that the energy resolution is within reason for particular photopeaks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Jet levitation of spherical shapes for microgravity research

The objective of the study reported here was to evaluate the usefulness of aerodynamic levitation for levitating and positioning spherical samples in microgravity materials processing experiments. In particular, results of levitation tests on spheres 3-15 mm in diameter, with material densities ranging from 2.37 to 7.78 g/cc, are presented. All tests were conducted using air jets of two different sizes. An analysis of the results obtained indicates that aerodynamic positioning can be used beneficially in space laboratories.

Krispin, Friedrich↗