Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAFE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

msr-safe

Modern processors offer a wide range of control and measurement features, such as performance counters, power capping, and thermal control. These features are ultimately controlled through Model Specific Registers (MSRs), which require elevated privileges for access. While this is often no problem on individual workstations, it is a significant security risk on multi-user systems and large-scale compute clusters. The msr-safe kernel module provides controlled user-level access to MSRs through a whitelisting mechanism. Is

MCFADDEN, MARTINJ↗

Laparoscopic Hyperthermic Intraperitoneal Chemotherapy is Safe for Patients with Peritoneal Metastases from Gastric Cancer and May Lead to Gastrectomy

Background: Laparoscopic hyperthermic intraperitoneal chemotherapy (LS-HIPEC) is a novel strategy for patients with gastric adenocarcinoma (GA) metastatic to the peritoneum. We evaluated the safety profile of LS-HIPEC for patients with positive peritoneal cytology (PPC) or carcinomatosis from GA. Methods: Outcomes were reviewed of patients with stage IV GA with peritoneal involvement who received LS-HIPEC from June 2014 to January 2017. LS-HIPEC included a 60-minute perfusion of mitomycin-C (30 mg) and cisplatin (200 mg) with inflow temperatures of 41–42 °C and outflow temperatures of 39–40 °C. Results: A total of 71 LS-HIPEC procedures were performed in 44 patients. At diagnosis, 68% (n = 30) had carcinomatosis and 32% (n = 14) had isolated PPC. Three patients (7%) underwent LS-HIPEC for intractable ascites. All patients initially received systemic chemotherapy, and 20 patients (45%) received pre-procedural chemoradiotherapy. The median number of LS-HIPEC procedures performed per patient was one (range 1–5 procedures). There were no conversions to laparotomy, two outflow catheter obstructions, and one major (Clavien-Dindo grade III) surgical complication within 30 days. A total of seven postoperative adverse hematologic events (> CTCAE 2) were observed in five patients (11%), without any major renal or gastrointestinal adverse events within 30 days. The median overall length of hospital stay after LS-HIPEC was 2 (range 2–11) days. Eleven patients (25%) underwent secondary gastrectomy following resolution of peritoneal cytology. Conclusions: Laparoscopic HIPEC is a safe procedure and may be repeated in patients with peritoneal metastases from gastric cancer. Future studies are required to determine the optimal HIPEC regimen and timing relative to systemic therapy to best minimize morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Robotic-Assisted Surgery Safe in the Elderly Population? An Analysis of Gynecologic Procedures in Patients ≥ 65 Years Old

Background: The elderly population is expanding worldwide but is underrepresented in clinical trials. We sought to assess the safety of robotic gynecologic surgery in an elderly cohort and to identify factors associated with unfavorable outcomes. Methods: All patients ≥ 65 years who underwent a robotically assisted procedure at a single institution between May 2007 to December 2016 were divided into three age groups: 65–74 (Group 1); 75–84 (Group 2); ≥ 85 (Group 3). Perioperative outcomes were recorded in patients who did not require conversion to laparotomy. We compared clinical variables among groups and performed multivariate logistic regression to detect variables associated with major complications (≥ Grade 3) or 90-day mortality. Results: We retrospectively identified 982 cases: 685 in Group 1; 249 in Group 2; 48 in Group 3. Median age = 71 years. Median BMI = 28.9. Malignancy was documented in 72.8% of cases; the majority were endometrial cancer (61.8%). Thirty-four patients (3.5%) were readmitted within 30 days. Seventy-seven (7.8%) had a postoperative complication, and 23 (2.3%) had a major complication. Ninety-day mortality was 0.5%. There was significant difference between groups with respect to body mass index (P = 0.026), ECOG PS (P ≤ 0.001), > 5 comorbidities (P = 0.005), hospital stay (P < 0.001), major complications (P = 0.001), and 90-day mortality (P < 0.001). On multivariable logistic regression, age ≥ 85 years was associated with major complications. Body mass index, age ≥ 85 years, and major complications were significantly associated with 90-day mortality. Conclusions: Robotic-assisted surgery appears to be safe in an elderly cohort. The incidence of overall and major complications is consistent with those reported in the literature. Patients ≥ 85 years old appear to be at higher risk of unfavorable outcomes.

60 APPLIED LIFE SCIENCES↗

A Nuclearly Safe Triangular-Slab Tank for Handling Enriched Uranium

In this study, an improved abrasive slurry tank for use with conventional liquid-honing machines was built and tested. Its shape, a 1.7-in.- (4.3-cm)-thick triangular slab, promotes good mixing by improving recirculation and is nuclearly safe for uranium enriched to 93% 235 U.

42 ENGINEERING↗

Enabling Technologies for Ultra-Safe and Secure Modular Nuclear Energy

Sandia National Laboratories and General Atomics are pleased to respond to the Advanced Research Projects Agency-Energy (ARPA-e)’s request for information on innovative developments that may overcome various current reactor-technology limitations. The RFI is particularly interested in innovations that enable ultra-safe and secure modular nuclear energy systems. Our response addresses the specific features for reactor designs called out in the RFI, including a brief assessment of the current state of the technologies that would enable each feature and the methods by which they could be best incorporated into a reactor design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recommended Practices for the Safe Design and Operation of Flywheels

Flywheel energy storage systems are in use globally in increasing numbers . No codes pertaining specifically to flywheel energy storage exist. A number of industrial incidents have occurred. This protocol recommends a technical basis for safe flywheel de sign and operation for consideration by flywheel developers, users of flywheel systems and standards setting organizations.

25 ENERGY STORAGE↗

Defining the safe current limit for opening ID photon shutter

The NSLS-II storage ring is protected from possible damage from insertion devices (IDs) synchrotron radiation by a dedicated active interlock system (AIS). It monitors electron beam position and angle and triggers beam drop if beam orbit exceeds the boundaries of pre-calculated active interlock envelope (AIE). The beamlines (BL) and beamline frontends (FE) are designed under assumption that the electron beam is interlocked within the AIE. For historic reasons the AIS engages the ID active interlock (AI-ID) at any non-zero beam current whenever the ID photon shutter (IDPS) is getting opened. Such arrangement creates major inconveniences for BLs commissioning. Apparently there is some IDPS safe current limit (SCL) under which the IDPS can be opened without interlocking the e-beam. The goal of this paper is to find such limit.

43 PARTICLE ACCELERATORS↗

Integral Inherently Safe Light Water Reactor (I 2 S-LWR)

This final report summarizes results of the multi-year effort performed during the period 2/2013- 12/2016 under the DOE NEUP IRP Project “Integral Inherently Safe Light Water Reactors (I 2 S-LWR)”. The goal of the project was to develop a concept of a 1 GWe PWR with integral configuration and inherent safety features, at the same time accounting for lessons learned from the Fukushima accident, and keeping in mind the economic viability of the new concept. Essentially (see Figure 1-1) the project aimed to implement attractive safety features, typically found only in SMRs, to a larger power (1 GWe) reactor, to address the preference of some utilities in the US power market for unit power level on the order of 1 GWe.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safe Active Scanning for Energy Delivery Systems Final Report

The Department of Energy’s Cybersecurity for Energy Delivery Systems Program has funded Safe(r) Active Scanning for Energy Delivery Systems, led by Lawrence Livermore National Laboratory, to investigate and analyze the impacts of active scanning in the operational environment of energy delivery systems. In collaboration with Pacific Northwest National Laboratory and Idaho National Laboratory, active scans across three testbeds including 38 devices were performed. This report gives a summary of the initial literature survey performed on the SASEDS project as well as industry partner interview summaries and main findings from Phase 1 of the project. Additionally, the report goes into the details of scanning techniques, methodologies for testing, testbed descriptions, and scanning results, with appendices to elaborate on the specific scans that were performed. As a result of testing, a single device out of 38 exhibited problems when actively scanned, and a reboot was required to fix it. This single failure indicates that active scanning is not likely to have a detrimental effect on the safety and resilience of energy delivery systems. We provide a path forward for future research that could enable wide adoption of active scanning and lead utilities to incorporate active scanning as part of their default network security plans to discover and rectify rogue devices, adversaries, and services that may be on the network. This increased network visibility will allow operational technology cybersecurity practitioners to improve their situational awareness of networks and their vulnerabilities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Cost III-V Photovoltaic Materials by Chloride Vapor Transport Deposition Using Safe Solid Precursors

Si-based photovoltaic devices dominate the market. As photovoltaic (PV) manufacturing costs have plummeted, technologies which increase efficiency have become critical. Si cell efficiencies are nearing theoretical limits and Si-based PV modules are unlikely to reach the 25-30% efficiency range. The use of III-V semiconductors is an obvious technical solution to improve efficiency, especially if they can be integrated directly with existing Si technology as tandems. High coefficients of light absorption along with tunable bandgaps and lattice constants have resulted in record conversion efficiencies for both one-sun and concentrator PV applications. GaAs, for example, has been used to manufacture single-junction photovoltaics with world-record efficiencies of 28.8% at one sun.2 However, costs for III-Vs must be dramatically reduced to produce cost-effective, high-efficiency PV solutions. III-V costs are controlled by two factors: semiconductor growth and the substrate. III-V growth is dominated today by metal-organic vapor phase epitaxy (MOVPE) with a lesser role played by molecular beam epitaxy (MBE). MOVPE costs are high due to the expense and low utilization (~30%) of precursors, modest growth rates (~100 nm min -1 ), equipment complexity, and safety infrastructure needed to handle toxic, pyrophoric gases.3 MBE costs are high due to slow growth rates and limitations of scalability. Details comparing plausible low-cost III-V growth methods are available in a review article published as a result of this project. The primary goal of this project was to demonstrate that close-spaced vapor transport (CSVT) using chloride (from HCl) as a transport agent can be used for the rapid growth of device-ready III-V layers from safe, solid-source precursors. In pursuit of this goal, we designed, built, and installed a new Cl-CSVT reactor based on insights from our previous H 2 O-CSVT growth system and in collaboration with equipment professionals at Malachite Technologies. This system was successfully used to grow epitaxial GaAs with controlled n-type doping, having mobilities similar to MOVPE. Detailed technical information and results can also be found in the primary publication resulting from this project. This work sets the stage for tackling the development of high-performance III-V single junctions and tandem devices directly on Si substrates, which was beyond the capabilities of our H2O-CSVT system. The design of the reactor’s source and substrate transfer system should allow for direct deposition of device structures. The collective innovations of our Cl-CSVT system might ultimately serve as an enabling process for commercialization of the technology through a collaboration with appropriate industrial partners.

14 SOLAR ENERGY↗

Chemical Conversion of Anhydrous Hydrogen Fluoride for Safe Disposal

A procedure for the safe conversion of a small (~ 1 gram) quantity of anhydrous hydrogen fluoride to calcium fluoride is described. The purpose of the conversion is to put the toxic, corrosive, gaseous compound into a chemical form that is a less toxic solid (calcium fluoride) and easier to dispose of. The hydrogen fluoride, which was contained in a 50 cc metal sample cylinder, was drawn by a small mechanical vacuum pump through an all-metal gas manifold and into a metal trap containing alternating layers of calcium oxide powder and Teflon turnings. The anhydrous hydrogen fluoride reacts with the calcium oxide to produce calcium fluoride and water vapor. Because some of the calcium oxide powder was drawn out of the trap and into the vacuum tubing, it was not possible to quantify the amount of anhydrous hydrogen fluoride converted to calcium fluoride. However, it was noted that there was a temperature rise in the trap when the gas was flowing through it, and no HF gas was detected at the vacuum pump exhaust at this time using a colorimetric Dräger tube. The trap was sealed and disposed of as solid chemical waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Planning a Resilient Power Sector: Ensuring Reliable, Secure, Safe, and Affordable Electricity

Decision makers around the globe are exploring strategies to ensure the reliable, secure, safe, and affordable supply of electricity to power economic growth and achieve development goals. Vulnerabilities of the power sector to natural hazards (e.g., acts of nature, severe weather, and climate variabilities), technological hazards (e.g., accidents and system or structure failures), and threats or human-caused incidents (e.g., intentional cyber-attacks or acts of terror) can impede the provision of the energy services necessary to achieve these goals. Although decision makers cannot prevent an act of nature such as an earthquake, they can anticipate, prepare for, and adapt to potential vulnerabilities through planning. The purpose of power sector resilience planning is to identify vulnerabilities and devise strategies to mitigate them. This document reviews some of the hazards that power sectors face and how decision makers can plan to increase resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers

This is the final scientific report for the award DE-FE0023305, entitled “Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers.” The work has been divided into six tasks. In Task 2, we characterized rock properties, which are important when developing a quantitative approach for understanding and predicting geomechanical effects on large-scale CO 2 injection and long-term storage in the subsurface. Rock properties of interest for this characterization include porosity, permeability, elastic constants, strength, and heat capacity. We measured rock properties for three different rock types: concrete, sandstone and shale. These properties were obtained from the acoustic measurement, permeability and porosity measurement, Brazilian test, the uniaxial compressive test, and heat capacity measurement. Then, using the Brazilian technique to fracture samples, we measured their permeability under brine injection for varying effective stresses, followed by similar measurements of permeability under sc-CO 2 injection. Permeability to brine and sc-CO 2 decreased as the effective stress increased. The apparent permeability to sc-CO 2 was an order of magnitude less than that for brine, a consequence of CO 2 being the non-wetting fluid. In Task 3, we developed understandings and correlations for CO 2 injection pressure induced fracturing. We initially fractured four eight inch cubes of concrete with brine to establish a standard test procedure. Then, additional concrete samples were fractured using brine. Confining stresses were exerted on the samples and brine was injected at a constant rate into a borehole that was previously drilled into the concrete cube. The borehole pressure was measured and fracture initiation was identified as a peak in the pressure profile. That was followed by fracture propagation, which was identified as a plateau in the pressure profile, and finally the fracture reached the sample surface. The sample surfaces were photographed before and after fracturing, which enabled determination of where the fracture reached the sample surface. Afterwards, aqueous food dye solution was injected into the fractured concrete samples to color the fracture planes. The borehole was filled with food dye solution in advance, a gas pulse was transmitted to the borehole, and the borehole was then shut in to allow the food dye to be driven into existing fractures. Then, the concrete samples were broken down by high-pressure gas injection to reveal the geometry and morphology of the hydraulic fractures. In addition, acoustic measurements were conducted on multiple locations on each face of the concrete samples before and after injection for comparison. This comparison was used to confirm changes in the internal structure of the concrete sample, namely the formation of fractures. There were six concrete samples fractured with brine. Afterwards, concrete samples were fracture using sc-CO 2 . The main change in experimental procedure was the inclusion of temperature control, since in the field, we mostly encounter temperature and pressure conditions above the supercritical point of CO 2 . The concrete samples were pre-heated in an oven to elevate their temperature, and thermal tape was used to heat the CO 2 to a temperature above its supercritical temperature. Two concrete samples were fractured using liquid CO 2 , four concrete samples were fractured using gaseous CO 2 , and twenty two concrete samples were fractured using sc-CO 2 . For the concrete samples fractured using sc-CO 2 , three had pre-existing hydraulic fractures on the surface near the wellbore, and two were water saturated (as opposed to containing only air). Two concrete samples were composite samples, with a high permeability ball in the center, in order to represent CO 2 injection into a high permeability zone surrounded by a low permeability sealing formation. Later, we fractured five shale samples, obtained from the Niobrara shale outcrop, with sc-CO 2 . The injection rate was constant, confining stresses were applied, the shale samples were pre-heated in an oven to the desired temperature, and the sample was then fractured. An analysis of the failure type was done for many of the concrete samples, based on the predicted break down pressure for tensile and shear failure, and it was found that most samples fractured due to shear failure. Also, the presence of induced fractures has little to no effect on the fracture initiation pressure, but significantly changes the fracture morphology. The CO 2 fracturing in water saturated samples behaved much similar to brine induced fracturing. There was a significant difference of breakdown pressure for injection of CO 2 and brine, where the breakdown pressure for CO 2 induced fracturing is generally around the minimum horizontal stress and that for brine is much higher. Finally, the fracture orientation for most samples with large confining stress differential was perpendicular to the minimum horizontal stress. When the stress differential, especially the difference between the two directions with the smallest stresses was small, the fracture orientation was determined not only by the minimum stress direction, but also the magnitude of the confining stress, the tensile strength of the rock, and the breakdown pressure. In Task 4, we modified our coupled flow-geomechanical models to model fracture growth and propagation in storage formations and caprocks. These flow-geomechanical models are TOUGH2-CSM and TOUGH2-FLAC. The TOUGH2-CSM fluid and heat flow formulation is based on the TOUGH2 formulation of mass and energy conservation equations that govern fluid and heat flow in general multiphase, multicomponent, multi-porosity systems. The TOUGH2-CSM simplified geomechanical formulation is based on the linear theory of elasticity applied to multi-porosity non-isothermal (thermo-multi-poroelastic) media. We previously derived, from the fundamental relations of the linear theory of elasticity, an equation relating mean stress, pore pressures, temperatures, and body force (the Mean Stress equation) that we added to the TOUGH2-CSM fluid and heat flow equations. We extended the TOUGH2-CSM simplified geomechanical formulation to calculate the entire stress tensor by deriving equations for stress tensor components from derivatives of the Cartesian thermo-multi-poroelastic Navier equation components. In addition, we derived equations for stress tensor components in rz-coordinates. We solved these geomechanical equations using the integral finite difference method. This method utilizes momentum fluxes obtained by “factoring” a divergence operator out of each geomechanical equation. In Task 5, we did a literature survey to determine suitable correlations for fracture initiation, growth, and propagation. After surveying numerous papers, we modified TOUGH2-CSM to model stress dependent fracture initiation and growth using the Mohr-Coulomb criterion for shear failure in faults and caprock and the condition of negative minimum effective stress for tensile failure. Tensile failure results in a fracture whose width depends on the difference between fracture pressure and minimum stress and whose propagation is based on the difference between the stress intensity factor at the fracture tip and the rock toughness. The TOUGH-FLAC model is based on the FLAC3D ubiquitous joint model, extended for the modeling of permeability changes induced by changes in effective normal stress across fractures as well permeability changes caused by shearing along fractures. In Task 6, we validated our coupled flow-geomechanical models using analytical solutions and problems from the literature. We validated the TOUGH2-CSM modifications using analytical solutions to the displacement from a uniform load on a semi-infinite elastic medium and the two-dimensional Mandel-Cryer effect. Those were followed by a sample problem to test our stress tensor calculations, which was for injection into a single-phase reservoir with constant properties. Comparisons of our simulator to published results were done on for the depletion of a single-phase reservoir with stress dependent porosity, two examples from the In Salah gas project, an axisymmetric baserock–reservoir–caprock system with a normal faulting stress regime that had thermally induced shear stresses, simulations of CO 2 leakage through caprock in a two-dimensional reservoir in Cartesian coordinates, and predictions of caprock failure from CO 2 injection into an axisymmetric reservoir. Finally, we simulated CO 2 injection pressure-induced fracturing from one of our laboratory studies, Sample 39, and obtained a fracture profile. We also validated the TOUGH2-FLAC model for fluid driven fracture growth against solutions based on the KGD model and a case with an inclined fracture that was loaded from the boundaries to achieve wing-crack propagation. The strain softening tensile behavior and softening of modulus considering a simple damage approach was verified by a simulation representing hydraulic fracturing stress measurement around a vertical well. Finally, the model was validated against deep fracture zone opening and surface uplift at In Salah with inverses analysis used to improve the match of simulation with field data. In Task 7, we developed a scheme based on inverse modeling that can be used to identify caprock leakage. Injection of fluid into a reservoir results in a time varying pressure profile that depends on the properties of the rock and the fluid. The presence of significant caprock leakage would effect this pressure profile and we used inverse modeling, namely the Levenberg-Marquardt method, to determine the leakage location from the pressure profile. A two-dimensional and a three-dimensional example based on published data were presented. The published simulation was run and its results were considered as “field” data. In the two-dimensional example, a simulation of CO 2 injection into a two-dimensional aquifer-caprock system, the caprock had a vertical fault through which leakage could occur. The location of this leakage was obtained from our inverse modeling scheme. In the three-dimensional example, the simulation domain had four geological layers, one of which was the injection zone that contained a horizontal injection well. We simulated fractures as high permeability gridblocks, introduced a fracture that spanned the caprock depth, and ran a simulation to obtain “field” data. Then, using our inverse modeling scheme, we obtained the location of that fracture.

58 GEOSCIENCES↗

Power Sector Resilience Planning: To Ensure Reliable, Secure, Safe and Affordable Electricity Supplies (Lab Translation)

Decision makers around the globe are exploring strategies to ensure the reliable, secure, safe, and affordable supply of electricity to power economic growth and achieve development goals. Vulnerabilities of the power sector to natural hazards (e.g., acts of nature, severe weather, and climate variabilities), technological hazards (e.g., accidents and system or structure failures), and threats or human-caused incidents (e.g., intentional cyber-attacks or acts of terror) can impede the provision of the energy services necessary to achieve these goals. Although decision makers cannot prevent an act of nature such as an earthquake, they can anticipate, prepare for, and adapt to potential vulnerabilities through planning. The purpose of power sector resilience planning is to identify vulnerabilities and devise strategies to mitigate them. This document reviews some of the hazards that power sectors face and how decision makers can plan to increase resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Methodology for Estimating Safe Charge Limits of Flammable Refrigerants in HVAC&R Applications - Part 2

This report provides a detailed description of the development of a reduced order model (ROM) that could be used for estimation of safe charge limits based on a computational fluid dynamics (CFD) parametric study. The ROM was developed to simulate leak events from a single side-wall duct penetration into a room and provide estimates of refrigerant concentration together with flammable volume fraction (FVF), accumulated fuel volume (AFV) and other outputs vs. time. The ROM is based on a range of seven parameters listed in Table ES1 and assumes that the AC unit air circulation blower is off. A total of 586 CFD “training” cases were run and used as the basis for development and training or calibration of the ROM. The regression analysis used to develop the ROM was performed in Tasmanian ( T oolkit for A daptive S tochastic M odeling A nd N on- I ntrusive A pproximatio N ). This is a tool developed at ORNL for high-dimensional integration, interpolation and parameter calibration. Comparison of the ROM vs. several CFD test cases (at points not used in the training set) showed maximum absolute and root mean square errors (RMSE) for FVF of 1.32% and 0.5%, respectively. Initial CFD runs were conducted to gauge the sensitivity of the results to each parameter. Based on the findings, the numbers of design of experiment (DoE) levels for each parameter was determined. Then, for each parameter, Tasmanian calculated the value of each level and defined a DoE of 586 unique CFD simulation cases.

42 ENGINEERING↗

Planning a Resilient Power Sector: Ensuring Reliable, Secure, Safe, and Affordable Electricity

Decision makers around the globe are exploring strategies to ensure the reliable, secure, safe, and affordable supply of electricity to power economic growth and achieve development goals. Vulnerabilities of the power sector to natural hazards (e.g., acts of nature, severe weather, and climate variabilities), technological hazards (e.g., accidents and system or structure failures), and threats or human-caused incidents (e.g., intentional cyber-attacks or acts of terror) can impede the provision of the energy services necessary to achieve these goals. Although decision makers cannot prevent an act of nature such as an earthquake, they can anticipate, prepare for, and adapt to potential vulnerabilities through planning. The purpose of power sector resilience planning is to identify vulnerabilities and devise strategies to mitigate them. This document reviews some of the hazards that power sectors face and how decision makers can plan to increase resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Safe, Low-Cost, High Energy-Density, Solid-State Li-Ion Batteries

We developed intrinsically safe, robust, low-cost, high-energy-density solid-state Li-ion batteries, by integrating high conductivity garnet-type solid Li ion electrolytes and several different cathodes in tailored microstructures, fabricated by low-cost supported thin-film ceramic techniques, to overcome the primary technological barriers to next generation battery technology. In this ARPA-E project we employed Li-garnet solid-state electrolytes pioneered by one of the co-investigators (Thangadurai) which has room temperature (RT) conductivity of ~10 -3 S cm -1 . The highly stable garnet SSE allowed the use of S, NMC, and other cathodes with Li metal anodes without stability or flammability concerns. We studied the garnet’s stability when exposed to CO 2 and humidity (with or without an ALD coating) and showed that the material can be processed in ambient air for most steps prior to battery assembly, significantly reducing production costs. We extensively studied and scaled up the synthesis of the powder and explored external suppliers of garnet to determine the best pathway for commercial success. We used low-cost and scalable tapecasting fabrication methods to create porous-dense-porous “trilayer” solid electrolyte microstructures with a ~20 μm separating dense layer, and >70% porosity porous layers to host the electrodes. These scalable multilayer ceramic fabrication techniques, without need for dry rooms or vacuum equipment, also provide for dramatically reduced manufacturing costs. The tailored microstructured electrode supports (scaffold) increased interfacial area ~50x, overcoming the high impedance typical of planar geometry SSLiBs, resulting in record-setting 10 mA/cm 2 lithium cycling in a symmetric cell. We expanded our tapecasting ability and showed tapes >25m in length by the end of the project. We demonstrated the ability to sinter garnet without the use of a garnet powderbed, which could have been a major obstacle and waste of material at scale. At the same time, we expanded the size of our trilayers from coin cells (0.7 cm 2 ) to the full format design (30 cm 2 ). To develop full cells, we demonstrated 250 Wh/kg at room temperature with commercial NMC electrode films in a bilayer configuration. Similarly, we demonstrated 280 Wh/kg trilayer Li-S cells at room temperature with >90% capacity retention over 300 cycles. At 90°C we demonstrated 350 Wh/kg with a Li-S trilayer. The high thermal stability of the garnet electrolyte also enabled extended cycling (400 cycles) of a Li-TiS 2 cell at 150 °C, showcasing the exceptional safety and nonflammability of the solid-state trilayer batteries. Ion Storage Systems has taken this technology and knowledge to produce trilayer garnet electrolytes and is building out facilities to commercialize high performance solid state batteries. ISS has hired a strong staff, identified and communicated with a large number of potential partners, and successfully secured follow-on funding.

25 ENERGY STORAGE↗

Development of a Safe, Reliable, and Versatile Explosive Demolition Initiation System

Demolition contractors have a need to simultaneously detonate many demolition charges safely, cheaply, and reliably. An explosive distribution company has contracted the Initiation Systems Group at Lawrence Livermore Laboratory as consultants. The task is to develop a new, safer initiation system to detonate anywhere from 1 to 2000 demolition charges. The primary user of the system will be the explosive demolition contractors.

42 ENGINEERING↗