Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Validation of 266 nm UV Raman thermometry using the alpha-to-beta quartz transition

Ultraviolet Raman scattering is a promising diagnostic for temperature measurements relevant to dynamic compression experiments, where improved signal strength and reduced background are critical. In this work, we experimentally validate Raman thermometry at 266 nm using crystalline quartz heated through the α to β phase transition in a tube furnace. Quartz provides a useful benchmark because of its well-characterized transition temperature near 846 K at ambient pressure. Temperatures inferred from the Stokes to anti-Stokes intensity ratio are compared with thermocouple measurements and with the observed phase transition. Single-shot Raman temperatures track the thermocouple closely, with an empirical single-shot scatter of approximately ±15 K under the present conditions. Temporal averaging reduces shot-to-shot scatter and improves agreement between the Raman temperatures and thermocouple readings to within approximately 8 K, while the transition is identified within 5 K of the accepted value. Measurements are performed using the fourth harmonic of a nanosecond pulsed Nd:YAG laser at 266 nm. The shorter excitation wavelength provides enhanced Raman scattering efficiency and reduced visible background relative to conventional visible excitation. Comparison with 532 nm Raman measurements acquired in the same experimental geometry demonstrates substantially improved signal-to-noise ratio for the UV configuration. These results establish 266 nm Raman thermometry as a reliable and accurate temperature diagnostic under controlled heating conditions and provide a quantitative benchmark for future application in dynamic compression and shock physics experiments.

Chemistry - Chemical explosives↗

Effect of coupling strength on atomic-to-molecular condensate conversion in Raman photoassociation

We study two-photon Raman photoassociation for creating a coherent molecular Bose-Einstein condensate (BEC) from an atomic BEC. By exploring the dynamics of the coupled system, we show that the atom-to-molecule conversion efficiency can be controlled by changing the atom-molecule coupling strength and the effective two-photon Raman detuning. Atom-molecule coupling strength and the effective two-photon Raman detuning can be controlled by changing the laser intensity. We analyze the dynamics of the coupled atom-molecular condensate system by changing the laser intensity over a broad range, keeping the effective two-photon Raman detuning fixed. The effective two-photon Raman detuning depends on the two-photon detuning, Rabi frequencies, and the light shifting (AC Stark shift) of the levels. To keep the effective two-photon Raman detuning fixed, the two-photon detuning is varied to compensate for the light shifting of levels with laser intensity. The corresponding changes in the effective decay rates and the scattering length due to the change in the Rabi frequencies have been taken into account. Dependence of the conversion efficiency on the effective two-photon Raman detuning has also been studied by varying the laser intensity over a narrow range, keeping the two-photon detuning unchanged. The dynamics of the coupled system has been studied in Gross-Pitaevskii and modified Gross-Pitaevskii approaches to demonstrate the effect of the higher order nonlinearity (Lee-Huang-Yang term) with the increase in the laser intensity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anomalous phonon-mode dependence in polarized Raman spectroscopy of the topological Weyl semimetal TaP

Topological Weyl semimetals (WSMs) have attracted widespread interest due to the chiral Weyl fermions and surface Fermi arcs that enable unique optical and transport phenomena. In this work, we present angle-resolved Raman spectroscopy of TaP, a prototypical noncentrosymmetric WSM, for five excitation wavelengths ranging from 364 to 785 nm. The Raman-active modes, $A_1$, $B^1_1$, and $B^2_1$ modes, exhibit two main unique features beyond the conventional Raman theory. First, the relative intensities of Raman-active modes change as a function of the excitation wavelength. Second, angle-resolved polarized Raman spectra show systematic deviation from the Raman tensor theory. In particular, the $B^1_1$ mode is absent for 633-nm excitation, whereas the $B^2_1$ mode shows an unusual twofold symmetry instead of a fourfold symmetry for 488-, 532-, and 633-nm excitations. Finally, these unconventional phenomena are attributed to the interference effect in the Raman process owing to the existence of multiple carrier pockets with almost the same energy but different symmetries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SERS Theory: The Chemical Effect of Rhodamine 6G Adsorption on Silver Surfaces on Its Raman Spectrum

The SERS spectra of small organic molecules can be very sensitive to the physisorption or chemisorption of the molecules onto metallic surfaces. However it is challenging to model the results, as typical SERS substrates have a broad distribution of possible surface sites, and the populations of these sites and the SERS enhancement factors associated with them are very difficult to determine, especially when electromagnetic hot spots dominate the observed spectra. However it is important to account for these effects if one is to make a quantitative interpretation of measured SERS spectra. Indeed, the influence of different sites is important to both the electromagnetic and chemical mechanisms in SERS, where the former mechanism is concerned with local field enhancement effects arising from plasmon excitation, while the latter arises from the effect of chemisorption induced charged transfer on the Raman intensities, as can be modeled using static limit Raman intensity calculations[1]. Extensive studies have been performed on simple organics like pyridine bound to gold and silver clusters, and it was found that both the chemical and electrodynamic enhancement factors associated with binding pyridine in various orientations result in noticeable changes in the SERS spectra compared to the gas phase spectrum of pyridine.[2] One of the most important benchmark molecules for SERS and TERS studies is Rhodamine 6G (R6G). This is a strongly fluorescent dye molecule in solution, but when adsorbed onto SERS substrates, its fluorescence is quenched, and the resulting SERS intensities are among the largest observed for any molecule. As a result R6G has played a crucial role in the development of single molecule SERS, and in the development of SERS substrates. [3, 4] Previously, the SERS spectrum of R6G has been modeled as if it were a gas phase molecule. Jensen and Schatz[5] incorporated resonant effects as well as vibronic effects and found that resonance excitation to the S1 excited state of R6G resulted in good agreement with spectra obtained from SERS experiments. In another study, intermolecular charge transfer was studied with R6G bound to a Ag2 cluster.[6] It is unclear if a cluster model as small as two silver atoms can accurately capture the surface effects of a nanoparticle with thousands of atoms. Recent single molecule, ultra high vacuum, tip enhanced Raman spectroscopy (SM-UHV-TERS) measurements for R6G[3] were moderately reproduced by gas phase resonance Raman calculations. Of particular importance in this work was the comparison of TERS spectra at room temperature with those at a low temperature of 10K. It was found that lowering the temperature led to both sharpening of the vibrational spectra, and shifts in the spectra (up to 20 cm-1 with some lines shifting red, some blue and some not at all), suggesting that the molecule transitions from a largely gas phase molecule at room temperature to being strongly chemisorbed at 10K. A potential energy distribution analysis performed by Chulhai and Jensen[3] showed that the modes that were shifted from the gas phase had vibrational activity associated with the ethylamine component of R6G, which is the likely moiety associated with Raman calculations. What remains unresolved concerning the SM-UHV-TERS studies of R6G is direct evidence that the chemical binding of R6G to a silver nanoparticle surfaces causes frequency shifts and/or intensity changes in the Raman scattering intensities of specific modes, especially those involving vibrations of the ethylamine moiety. The theoretical work described in this chapter directly addresses this issue by calculating Raman spectra for R6G interacting with a 20-atom silver cluster, and with a flat Ag(111) surface. Tetrahedral Ag20 is chosen for part of these studies as it provides a model nanoparticle structure that has a well-defined fragment of a (111) surface, as well as having edges and vertices that can be used to model coordinately unsaturated sites on a particle. In addition, Ag20 has been found to provide a reasonable reference structure for determining the chemical contribution to SERS enhancements.[1] Two different geometries of the Ag20/R6G system are considered in the present study, corresponding to two different binding configurations of R6G to a pristine Ag(111) surface. In addition, we study adsorption of R6G on a flat Ag(111) surface of using plane wave DFT calculations to determine optimized geometries and normal mode properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Raman scattering in the atmospheres of the major planets

A technique is developed to calculate the detailed effects of Raman scattering in an inhomogeneous anisotropically scattering atmosphere. The technique is applied to evaluations of Raman scattering by H2 in the atmosphere of the major planets. It is noted that Raman scattering produces an insufficient decrease in the blue and ultraviolet regions to explain the albedos of all planets investigated. For all major planets, the filling-in of solar line cores and the generation of the Raman-shifted ghosts of the Fraunhofer spectrum are observed. With regard to Uranus and Neptune, Raman scattering is seen to exert a major influence on the formation and profile of strong red and near infrared CH4 bands, and Raman scattering by H2 explains the residual intensity in the cores of these bands. Raman scattering by H2 must also be taken into account in the scattering of photons into the cores of saturated absorption bands.

Cochran, W. D.↗

Raman intensity as a probe of concentration near a crystal growing in solution

The feasibility of using Raman spectral scattering signals for measurements of concentration profiles near a crystal interface during growth or dissolution is discussed. With KH2PO4 (KDP) as a test material, optical multichannel analyzer (OMA) detection of a solute Raman vibrational band provided direct quantification of solute concentration with band intensity. The intersection of incident laser and Raman collection optics provided 3-D selective point measurements of the solution concentration field. Unlike many other techniques, the Raman band intensity is not sensitive to the typical temperature variations. Precision calibration of Raman intensity versus KDP concentration with less than 1 pct standard deviation error levels was demonstrated. A fiber optic, which sampled incident laser intensity and coupled it to the OMA, provided a fully synchronized monitor of fluctuations in laser power to correlate with observed Raman signals. With 1 W of laser power at the sample, good data statistics required eight repeated data collections at approximately 2.5 min collection. The accumulated time represents the concentration measurement time at one spatial location. Photomicroscopy documented a 30 micrometer diameter by 200 micrometer of laser Raman scattering region in the solution near the crystal surface. The laser beam was able to approach up to 25 micrometer from the crystal surface. However, a crystal surface reflected intensity contribution was weakly detectable. Nucleated microcrystals were seen in the crystal-growing solution. These microcrystals convect right up to the crystal surface and indicate no quiet diffusion region under normal gravity conditions. Translation of the solution cell with respect to the optics caused systematic intensity errors.

Wilkinson, R. Allen↗

Measurements of Stratospheric Pinatubo Aerosol Extinction Profiles by a Raman Lidar

The Raman lidar has been used for remote measurements of water vapor, ozone and atmospheric temperature in the lower troposphere because the Raman cross section is three orders smaller than the Rayleigh cross section. We estimated the extinction coefficients of the Pinatubo volcanic aerosol in the stratosphere using a Raman lidar. If the precise aerosol extinction coefficients are derived, the backscatter coefficient of a Mie scattering lidar will be more accurately estimated. The Raman lidar has performed to measure density profiles of some species using Raman scattering. Here we used a frequency-doubled Nd:YAG laser for transmitter and received nitrogen vibrational Q-branch Raman scattering signal. Ansmann et al. (1990) derived tropospherical aerosol extinction profiles with a Raman lidar. We think that this method can apply to dense stratospheric aerosols such as Pinatubo volcanic aerosols. As dense aerosols are now accumulated in the stratosphere by Pinatubo volcanic eruption, the error of Ramen lidar signal regarding the fluctuation of air density can be ignored.

Abo, Makoto↗

Raman Spectroscopy for Mineral Identification and Quantification for in situ Planetary Surface Analysis: A Point Count Method

Quantification of mineral proportions in rocks and soils by Raman spectroscopy on a planetary surface is best done by taking many narrow-beam spectra from different locations on the rock or soil, with each spectrum yielding peaks from only one or two minerals. The proportion of each mineral in the rock or soil can then be determined from the fraction of the spectra that contain its peaks, in analogy with the standard petrographic technique of point counting. The method can also be used for nondestructive laboratory characterization of rock samples. Although Raman peaks for different minerals seldom overlap each other, it is impractical to obtain proportions of constituent minerals by Raman spectroscopy through analysis of peak intensities in a spectrum obtained by broad-beam sensing of a representative area of the target material. That is because the Raman signal strength produced by a mineral in a rock or soil is not related in a simple way through the Raman scattering cross section of that mineral to its proportion in the rock, and the signal-to-noise ratio of a Raman spectrum is poor when a sample is stimulated by a low-power laser beam of broad diameter. Results obtained by the Raman point-count method are demonstrated for a lunar thin section (14161,7062) and a rock fragment (15273,7039). Major minerals (plagioclase and pyroxene), minor minerals (cristobalite and K-feldspar), and accessory minerals (whitlockite, apatite, and baddeleyite) were easily identified. Identification of the rock types, KREEP basalt or melt rock, from the 100-location spectra was straightforward.

Haskin, Larry A.↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Optically accessible, high pressure, hot fire test articles are available at NASA Marshall for use in development of advanced rocket engine propellant injectors. Single laser-pulse ultraviolet (UV) Raman spectroscopy has been used in the past in these devices for analysis of high pressure H2- and CH4-fueled combustion, but relies on an independent pressure measurement in order to provide temperature information. A variation of UV Raman (High Resolution Hydrogen Raman Spectroscopy) is under development and will allow temperature measurement without the need for an independent pressure measurement, useful for flows where local pressure may not be accurately known. The technique involves the use of a spectrometer with good spectral resolution, requiring a small entrance slit for the spectrometer. The H2 Raman spectrum, when created by a narrow linewidth laser source and obtained from a good spectral resolution spectrograph, has a spectral shape related to temperature. By best-fit matching an experimental spectrum to theoretical spectra at various temperatures, a temperature measurement is obtained. The spectral model accounts for collisional narrowing, collisional broadening, Doppler broadening, and collisional line shifting of each Raman line making up the H2 Stokes vibrational Q-branch spectrum. At pressures from atmospheric up to those associated with advanced preburner components (5500 psia), collisional broadening though present does not cause significant overlap of the Raman lines, allowing high resolution H2 Raman to be used for temperature measurements in plumes and in high pressure test articles. Experimental demonstrations of the technique are performed for rich H2-air flames at atmospheric pressure and for high pressure, 300 K H2-He mixtures. Spectrometer imaging quality is identified as being critical for successful implementation of technique.

Wehrmeyer, Joseph A.↗

Investigating Surface Mineralogy, Alteration Processes, and Biomarkers on Mars Using Laser Raman Spectroscopy

Despite a wealth of information from past and ongoing missions to Mars, the capability to determine the mineralogy of surface materials and to connect mineralogy with lithologic characteristics that are diagnostic of the environment in which those materials formed remains inadequate. The 2003 Mars Exploration Rovers (MER) will carry a Mini-TES and a Mossbauer spectrometer, which will provide some detailed mineralogy information. For general characterization of minerals and/or biogenic phases (reduced carbon, PAHs, etc) on the surface of Mars, we have been developing a miniaturized laser Raman spectrometer for in situ analyses -- the Mars Microbeam Raman Spectrometer, MMRS. We are also developing strategies to use Raman spectroscopy as a stand-alone technique and to be used synergistically with other in situ analysis methods in future planetary missions. Through studies of Martian meteorites and terrestrial analogs, we are gaining experience of what compositional and structural information can be obtained on key mineral groups using in-situ Raman measurements. We are developing methods for determining mineral proportions in rocks or soils and identifying rock types from sets of closely spaced, rapidly acquired spectra. We are studying how weathering and alteration affect the Raman and luminescence features of minerals and rocks, and we are investigating the Raman characteristics of biogenic organisms and their remains. These studies form the scientific basis for in-situ planetary Raman spectroscopy, and they are being done in parallel with instrument development towards a flight version of the MMRS.

Alian Wang↗

Evaluation of Daytime Measurements of Aerosols and Water Vapor made by an Operational Raman Lidar over the Southern Great Plains

Raman lidar water vapor and aerosol extinction profiles acquired during the daytime over the Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site in northern Oklahoma (36.606 N, 97.50 W, 315 m) are evaluated using profiles measured by in situ and remote sensing instruments deployed during the May 2003 Aerosol Intensive Operations Period (IOP). The automated algorithms used to derive these profiles from the Raman lidar data were first modified to reduce the adverse effects associated with a general loss of sensitivity of the Raman lidar since early 2002. The Raman lidar water vapor measurements, which are calibrated to match precipitable water vapor (PWV) derived from coincident microwave radiometer (MWR) measurements were, on average, 5-10% (0.3-0.6 g/m(exp 3) higher than the other measurements. Some of this difference is due to out-of-date line parameters that were subsequently updated in the MWR PWV retrievals. The Raman lidar aerosol extinction measurements were, on average, about 0.03 km(exp -1) higher than aerosol measurements derived from airborne Sun photometer measurements of aerosol optical thickness and in situ measurements of aerosol scattering and absorption. This bias, which was about 50% of the mean aerosol extinction measured during this IOP, decreased to about 10% when aerosol extinction comparisons were restricted to aerosol extinction values larger than 0.15 km(exp -1). The lidar measurements of the aerosol extinction/backscatter ratio and airborne Sun photometer measurements of the aerosol optical thickness were used along with in situ measurements of the aerosol size distribution to retrieve estimates of the aerosol single scattering albedo (omega(sub o)) and the effective complex refractive index. Retrieved values of omega(sub o) ranged from (0.91-0.98) and were in generally good agreement with omega(sub o) derived from airborne in situ measurements of scattering and absorption. Elevated aerosol layers located between about 2.6 and 3.6 km were observed by the Raman lidar on May 25 and May 27. The airborne measurements and lidar retrievals indicated that these layers, which were likely smoke produced by Siberian forest fires, were primarily composed of relatively large particles (r(sub eff) approximately 0.23 micrometers), and that the layers were relatively nonabsorbing (omega(sub o) approximately 0.96-0.98). Preliminary results show that major modifications that were made to the Raman lidar system during 2004 have dramatically improved the sensitivity in the aerosol and water vapor channels and reduced random errors in the aerosol scattering ratio and water vapor retrievals by an order of magnitude.

Ferrare, Richard↗

Simultaneous Spectral Temporal Adaptive Raman Spectrometer - SSTARS

Raman spectroscopy is a prime candidate for the next generation of planetary instruments, as it addresses the primary goal of mineralogical analysis, which is structure and composition. However, large fluorescence return from many mineral samples under visible light excitation can render Raman spectra unattainable. Using the described approach, Raman and fluorescence, which occur on different time scales, can be simultaneously obtained from mineral samples using a compact instrument in a planetary environment. This new approach is taken based on the use of time-resolved spectroscopy for removing the fluorescence background from Raman spectra in the laboratory. In the SSTARS instrument, a visible excitation source (a green, pulsed laser) is used to generate Raman and fluorescence signals in a mineral sample. A spectral notch filter eliminates the directly reflected beam. A grating then disperses the signal spectrally, and a streak camera provides temporal resolution. The output of the streak camera is imaged on the CCD (charge-coupled device), and the data are read out electronically. By adjusting the sweep speed of the streak camera, anywhere from picoseconds to milliseconds, it is possible to resolve Raman spectra from numerous fluorescence spectra in the same sample. The key features of SSTARS include a compact streak tube capable of picosecond time resolution for collection of simultaneous spectral and temporal information, adaptive streak tube electronics that can rapidly change from one sweep rate to another over ranges of picoseconds to milliseconds, enabling collection of both Raman and fluorescence signatures versus time and wavelength, and Synchroscan integration that allows for a compact, low-power laser without compromising ultimate sensitivity.

Blacksberg, Jordana↗

Atmospheric Temperature from Raman Scattering

Raman scattering signatures are functions of the scattering-gas temperature, and are therefore of potential use for practical atmospheric temperature probes. The method described uses either ratios of pure rotational Raman scattering intensities for air utilizing various spectral bandpasses, or, alternatively, ratios of air-rotational to nitrogen-vibrational scattering intensities. Three aspects of work relating to the development of such probes are discussed in this presentation: (1) fundamental absolute Raman data, (2) construction of air spectra from these data, and (3) temperature-sensitivity of the signature. The fundamental data described are the absolute rotational and vibrational scattering cross sections. Recent measurements in this laboratory of rotational cross sections for N2, O2, and CO2 are emphasized, as are their use in predicting absolute magnitudes of Raman scattering signals. Next is described the computation of air rotational Raman spectra as a function of temperature calculated through use of the experimentally-measured cross sections. The spectra are based additively upon nitrogen and oxygen contributions, since pure rotational Raman scattering from water vapor is very weak. Finally, the sensitivity of the scattering intensity ratios to temperature is explored as a function of choice of spectral bandpass for the monitored rotational Raman scattering. Various compromises will be discussed which must be made in choosing bandpasses appropriate for specific purposes and experimental conditions.

Lapp, M.↗

Raman Spectroscopy of DNA Packaging in Individual Human Sperm Cells distinguishes Normal from Abnormal Cells

Healthy human males produce sperm cells of which about 25-40% have abnormal head shapes. Increases in the percentage of sperm exhibiting aberrant sperm head morphologies have been correlated with male infertility, and biochemical studies of pooled sperm have suggested that sperm with abnormal shape may contain DNA that has not been properly repackaged by protamine during spermatid development. We have used micro-Raman spectroscopy to obtain Raman spectra from individual human sperm cells and examined how differences in the Raman spectra of sperm chromatin correlate with cell shape. We show that Raman spectra of individual sperm cells contain vibrational marker modes that can be used to assess the efficiency of DNA-packaging for each cell. Raman spectra obtained from sperm cells with normal shape provide evidence that DNA in these sperm is very efficiently packaged. We find, however, that the relative protein content per cell and DNA packaging efficiencies are distributed over a relatively wide range for sperm cells with both normal and abnormal shape. These findings indicate that single cell Raman spectroscopy should be a valuable tool in assessing the quality of sperm cells for in-vitro fertilization.

59 BASIC BIOLOGICAL SCIENCES↗

Cation distribution and particle size effect on Raman spectrum of CoFe{sub 2}O{sub 4}

Moessbauer and Raman spectroscopic studies were carried out on CoFe{sub 2}O{sub 4} particles synthesized with size ranging from 6 to 500 nm (bulk). Cation distribution studies were carried out on the high temperature and room temperature phases of the microcrystalline CoFe{sub 2}O{sub 4} by Moessbauer and Raman spectroscopic methods. The high temperature phase of CoFe{sub 2}O{sub 4} showed a decreased inversion parameter of 0.69 as compared to the value of the room temperature phase of 0.95, indicating that the structure gradually transforms towards a normal spinel. Corresponding Raman spectra for these two phases of CoFe{sub 2}O{sub 4} showed a change in relative peak intensity of the vibrational mode at 695 cm{sup -1}(A{sub 1g}(1)) to 624 cm{sup -1} (A{sub 1g}(2)). The relative peak intensity ratio, I{sub v} between the A{sub 1g}(1) and A{sub 1g}(2) vibrational mode was decreasing with lowering of inversion parameter of the CoFe{sub 2}O{sub 4} spinel system. A variation of laser power on the sample surface was reflected in the cation distribution in ferrite phase. Superparamagnetic, single domain CoFe{sub 2}O{sub 4} particles (6 nm) showed a 20 cm{sup -1} red shift and broadening of phonon modes when compared to the macro-crystalline CoFe{sub 2}O{sub 4} (500 nm). Variation of Raman shift with particle size was studied by considering the bond polarization model. Raman spectroscopic studies clearly indicate the variation in the cation distribution in nano-sized particles and distribution tending to a normal spinel structural configuration. -- Graphical abstract: Variation of Raman shift difference ({Delta}{omega}) with size. Display Omitted

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Polarized IR and Raman spectra of Ca{sub 2}MgSi{sub 2}O{sub 7}, Ca{sub 2}ZnSi{sub 2}O{sub 7} and Sr{sub 2}MgSi{sub 2}O{sub 7} single crystals: Temperature-dependent studies of commensurate to incommensurate and incommensurate to normal phase transitions

IR and Raman spectra of Ca{sub 2}MgSi{sub 2}O{sub 7}, Ca{sub 2}ZnSi{sub 2}O{sub 7} and Sr{sub 2}MgSi{sub 2}O{sub 7} oriented single crystals and powders have been measured. The temperature dependence of phonons has been established in the 4-650 K range. Discussion of the results has been performed on the basis of factor group approach for the tetragonal P4-bar 2{sub 1}m (D{sub 2d}{sup 3}) space group with Z=2. The assignment of the bands observed to the internal and external modes has been made on their polarization behaviour, phonon energy calculations and literature data. The evidences of the LO-TO splitting and commensurate (C) to incommensurate (IC) as well as incommensurate (IC) to normal (N) phase transitions have been found. As a representative example, the results obtained for the spontaneous Raman scattering have also been used in the discussion of the stimulated Raman spectra of Ca{sub 2}ZnSi{sub 2}O{sub 7}. - Graphical abstract: Raman and IR spectra of Ca{sub 2}MgSi{sub 2}O{sub 7}, Ca{sub 2}ZnSi{sub 2}O{sub 7}, Sr{sub 2}MgSi{sub 2}O{sub 7} have been measured. The temperature dependence of phonons has been established in the 4-650 K range. The evidences of the LO-TO splitting and commensurate (C) to incommensurate (IC) as well as incommensurate (IC) to normal (N) phase transitions have been found. Highlights: Black-Right-Pointing-Pointer Polarized IR and Raman spectra of pyrosilicates single crystals have been studied. Black-Right-Pointing-Pointer Temperature dependence of the phonon bands and LO-TO splitting have been analysed. Black-Right-Pointing-Pointer Commensurate to incommensurate and to normal phase have been evidenced in the spectra. Black-Right-Pointing-Pointer Phonon calculations have been used in assignment of the normal modes. Black-Right-Pointing-Pointer Stimulated Raman spectra of Ca{sub 2}ZnSi{sub 2}O{sub 7} crystal have been measured and analysed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman Digital Twin of Monolayer Janus Transition Metal Dichalcogenides

Monolayer transition metal dichalcogenides (TMDs) are a key class of two-dimensional (2D) materials with broad technological potential. Their Janus counterparts exhibit unique properties due to broken out-of-plane symmetry and further enrich the functionalities of TMDs. However, experimental synthesis and identification of Janus TMDs remain challenging. It is thus highly desirable to have a rapid, simple, and in situ characterization technique to monitor, in real time, the conversion process from the parent to Janus structure. Raman spectroscopy stands out for such a task as it is a powerful, nondestructive, and very commonly used tool to characterize 2D materials both in situ and ex situ. To realize the full potential of Raman spectroscopy on rapid characterization of Janus TMDs, we present a computational “Raman digital twin” library for various monolayer Janus TMDs in both 2H and Td phases. We focus on group-6 TMDs: MoS 2 , WS 2 , MoSe 2 , WSe 2 , MoTe 2 , WTe 2 and their Janus variants: MoSSe, MoSTe, MoSeTe, WSSe, WSTe, and WSeTe. Using first-principles density functional theory (DFT), we calculate their vibrational properties and predict distinct Raman fingerprints. These phonon and Raman signatures reflect each material’s structural symmetry and atomic composition, enabling clear identification via Raman spectroscopy. Our theoretical work supports experimental efforts by providing benchmarks for material identification, structural analysis, and quality control. In conclusion, the computational library expedites the discovery and development of Janus 2D materials, facilitating tighter integration between theoretical predictions and experimental validation.

Chalcogenides↗

High fidelity nanohole enhanced Raman spectroscopy.

Surface enhanced Raman spectroscopy (SERS) is a sensitive technique that can even detect single molecules. However, in many SERS applications, the strongly inhomogeneous distribution of intense local fields makes it very difficult for a quantitive assessment of the fidelity, or reproducibility of the signal, which limits the application of SERS. Herein, we report the development of exceptionally high-fidelity hole-enhanced Raman spectroscopy (HERS) from ordered, 2D hexagonal nanohole arrays. We take the fidelity f to be a measure of the percent deviation of the Raman peaks from measurement to measurement. Overall, area averaged fidelities for 12 gold array samples ranged from f {approx} 2-15% for HERS using aqueous R6G molecules. Furthermore, intensity modulations of the enhanced Raman spectra were measured for the first time as a function of polarization angle. The best of these measurements, which focus on static laser spots on the sample, could be consistent with even higher fidelities than the area-averaged results. Nanohole arrays in silver provided supporting polarization measurements and a more complete enhanced Raman fingerprint for phenylalanine molecules. We also carried out finite-difference time-domain calculations to assist in the interpretation of the experiments, identifying the polarization dependence as possibly arising from hole-hole interactions. Our results represent a step toward making quantitative and reproducible enhanced Raman measurements possible and also open new avenues for a large-scale source of highly uniform hot spots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗