Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiological Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Triso Analysis Tool For Predictive Source Terms

Source term modeling for TRi-structural ISOtropic (TRISO) fuel has been performed for previous reactor designs, but few are available in the open literature. Thus, there is a need to develop a simple, versatile, and mechanistic model of fission product release and transport in gas reactor cores that can be applied to a variety of reactors through user inputs and reactor-specific radionuclide inventories. To meet this need, the TRISO Analysis Tool for Predictive Source terms (TRISO-ATOPS) was developed. This model calculates the release of the key safety-important fission products by diffusion through the kernel, silicon carbide and graphite based on fuel and graphite temperatures in the reactor under normal operation. These releases from the fuel enter the coolant where they can plate-out on cooler surfaces. A clean-up model is included for designs with a coolant purification system for removing fission gases. This initial distribution of fission products in the reactor serves as an initial condition for potential releases under postulated accident conditions. From this initial condition, the model calculates the fission product release for any transient temperature profile, and the fission product releases can then be used to assess radiological dose to the workers and the public using conventional radiological dose tools. Data on the diffusion of fission products is based on historic German TRISO experiments and the more current Department of Energy Advanced Gas Reactor TRISO fuel development program. The example cases in this work demonstrate the flexibility of the model

Stoyer, Benjamin [Idaho National Laboratory (INL),↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Validation of Mechanical & Autonomous Systems in Harsh Environments [Poster]

The autonomous systems within the Mobile Hot Cell provide advanced capabilities over traditional hot cells, pushing the boundaries of these systems in harsh environments. The degraded state of some radiological devices and the variety of designs present a series of challenges that require innovative tooling and procedural solutions. By leveraging technical knowledge and experience from disposition experts at SwRi and other institutions, initial design concepts were produced using rapid prototyping techniques. These concepts were then validated and optimized in a non-hazardous test bed, resulting in iterative improvements at minimal cost.

07 - ISOTOPES AND RADIATION SOURCES↗

Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Sodium Pool

Mechanistic source term (MST) analyses are likely to be an important part of advanced reactor licensing applications. For the purpose, an MST analysis code applicable to newly introduced advanced reactors, called SRT (Simplified Radionuclide Transport) code, has been developed by Argonne National Laboratory. SRT can track overall behaviors of radionuclides especially in metal fuel-based sodium fast reactors (SFRs) and microreactors. Throughout the simulation, migration inside fuel pins before failure, interaction with coolant (for SFR), removal/leakage in cover gas and containment (or confinement), and environmental dose impacts are considered alongside radioactive decay for short-lived nuclides. Among the postulated process, pool scrubbing phenomenon, especially under sodium pool condition, has been identified as high importance with limited supportive data. The phenomenon plays a crucial role in assessing the degree of radiological impacts as radioactive aerosols or vapors are efficiently and effectively removed during the process. To provide validation basis for SRT in assessing pool scrubbing performance inside sodium pools, the University of Wisconsin-Madison performed tests including extensive parametric effects. Separate effect tests were conducted to directly evaluate the SRT models and to estimate degree of contribution by each contributing factor. Specifically, bubble size, aerosol size, aerosol density, aerosol concentration, pool depth, system temperature, and bubble swarm effects were considered. According to the parametric effects, decontamination performance enhances with decreasing bubble size, large density, and deeper pool height. Aerosol concentration provides no effect for the whole range of interest, and pool temperature variation shows minor effects under the considered temperature condition. When multiple bubbles are injected generating a bubble swarm condition, DF performance further enhances by bubble interactions and turbulence characteristics. The measurement shows the exceptional importance of aerosol size range considered, with the lowest decontamination, where most radionuclides are expected to escape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Facile Solvent-Free Synthesis of Manganese Nickel-Layered Double Hydroxide for Sustainable Water-Splitting Applications

The quest for efficient and sustainable water-splitting electrocatalysts has led to the development of a novel bifunctional material, manganese nickel-layered double hydroxide (MnNi-LDH), which demonstrates promising performance for both the oxygen evolution reaction (OER) and hydrogen evolution reaction (HER). Although manganese-based materials are less explored than other transition metals, they offer significant potential owing to their widespread availability, affordability, and customizable electronic characteristics. MnNi-LDH exhibits a nanosheet morphology and a layered structure, which collectively provide numerous accessible active sites and facilitate efficient charge transfer and mass transport. Characterization using X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy, and transmission electron microscopy reveals the structural and compositional properties of MnNi-LDH. The oxidation states of Mn and Ni, as determined by XPS, play a crucial role in improving the catalytic activity. Notably, MnNi-LDH demonstrates low overpotentials of 187 mV for OER and 225 mV for HER at 10 mA/cm 2 current density comparable to conventional catalysts. Long-term stability tests show minimal degradation in cell performance over 50 h, with a current density drop of only 0.6153% per hour for the OER and 0.37% per hour for the HER. Further, these findings highlight the potential of MnNi-LDH as a promising and environmentally friendly bifunctional electrocatalyst for water splitting, contributing to the advancement of renewable energy sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2023 SAGE-Camp Report

The 7 th Summer Physics Camp for Young Women was successfully held in person in 2023 from June 5 th to 16 th at the New Mexico School for the Arts in Santa Fe, NM at Hilo Intermediate School in Hawaii. This year’s camp was dedicated to the topic of Energy Security and was made possible thanks to the strong collaboration of Los Alamos, Sandia and Hawaii teams and the logistical and financial support of Los Alamos and Sandia National Laboratories, New Mexico Consortium, SAGE- Moore Foundation, LANL Foundation, ACS, IEE, APS four corners, N3B, Hawaii Museum of Science and Technology, New Mexico School for the Arts (NMSA) and Tech Source. The camp mobilized more than 120 volunteers who made the camp a success. The camp is free of charge to the students and included free lunch and snacks for the busy brains to have plenty of energy, also included all materials needed for the hands-on activities (like drone building, crystal structure, solar panels, wind turbine fabrication, soldering, coding etc) and also a stipend for students who attended for the full two weeks and for two educators and two student mentors in NM. The camp offered 32 high school students from New Mexico and 8 from Hawaii a unique opportunity to explore science topics and meet a broad range of role model professionals across STEM fields including astrophysics, cybersecurity, Energy fields, space science, engineering, biophysics, environmental science, robotics, computer science, nuclear engineering, radiological science, physics and chemistry. With nearly 120 volunteers who came mainly from Los Alamos National Laboratory (66%) and Sandia national laboratories (18%), two funded educators from NM, Dr. Weldon Beauchamp and Dr. Ellee Cook, and two educators from Hilo, Dr. Pascale Creek Pinner and LeAnn Ragasa, the camp was educationally sound and extremely varied. The collaboration with school educators is critical for the goal of this camp to not only impact students' lives but also improve STEM education in NM and Hawaii. The ultimate goal of the camp is to increase higher education aspirations of students, empower them to consider careers in STEM and learn more about the opportunities available to them in our local colleges and DOE National Laboratories. In addition, the camp also hired 2 past students as student mentors, Megan Odom and Elisea Jackson, who currently attend NMSA and were students at the camp in 2022 when it was virtual. The in-person camp which aims at empowering under-represented minorities in STEM in our community received more than 52 applications this year from all over NM and 8 applications from Hawaii. Our selection criteria are based on diversity, equity and inclusion, and students for whom the camp can be a life-changing opportunity are given a chance to attend the camp. During COVID, the camp was held virtually and gave the opportunity to students from remote areas in NM and Hawaii to attend from their homes. This year, fantastic families supported students everyday even when home was in remote areas in NM like Lea county, Sandoval county, Bernalillo or Mora county. The organizers hope next year they can offer a residential option for students from remote areas.

99 GENERAL AND MISCELLANEOUS↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Replacement of Cobalt in Medical Device Sterilization: Current Trends, Opportunities and Barriers to Adoption of X-ray and E-Beam Within the Medical Device Sterilization Market

Radioactive sources, specifically Co-60, are crucially important to the medical device sterilization industry; however, their benefits must be balanced against the need to ensure that the materials are secure. Accelerator-based sterilization methods, including X-ray and E-Beam, can in many cases sufficiently replace Co-60 and ethylene oxide, the dominant modalities currently in use; however, a lack of hands-on experience with accelerators, regulations, and a lack of capacity have hampered faster adoption of these technologies. The market is likely to change, however, given public pressures against ethylene oxide and concerns over the cost and long-term supply chain robustness of Co-60. This may provide an opportunity for growth for accelerator capabilities. Current research at Sandia National Laboratories and Argonne National Laboratory, on behalf of the Department of Energy’s National Nuclear Security Administration Office of Radiological Security, is focused on developing an understanding of the medical device sterilization marketplace, the different modalities that are used to sterilize goods, and the drivers that affect the actors within it. Research at Pacific Northwest National Laboratory, in conjunction with the medical device sterilization industry, has focused on expanding the industry’s understanding of the capabilities of X-ray sterilization and developing data that can inform the industry’s consideration of a transition towards accelerator-based devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensor Placement Optimization Study for the Built Environment: Operational Use Cases

Systems of fixed-position radiation sensors can provide information that assists emergency responders following nuclear and radiological incidents. State, local, tribal, and territorial (SLTT) government agencies that implement systems of fixed-position sensors are faced with numerous decisions regarding sensor selection, quantity, and placement. To develop guidance on implementation of radiation detection systems, we simulated the release of radioactive material in an urban environment using a combination of three models: the Weather Research Forecasting (WRF), Quick Urban and Industrial Complex (QUIC), and Monte Carlo N-Particle (MCNP) models. We then evaluated the performance of several hypothetical sensor systems. The small number of simulations we conducted are not sufficient to generate definitive design guidance for radiation sensor systems, but we did identify trends that would be of interest to emergency planners. For a scenario that releases 1000 curies of Cs-137, radiation detectors were needed at 500-meter intervals to have a high likelihood of event detection and to estimate source location and plume detection. We also noted that optimal detector altitude varied with distance to the source. We recommend additional research in this area be conducted to support developing sensor placement guidelines that expand on a range of locations, isotopes, activity levels, and different weather conditions. Original simulation strategies included a range of environments, additional radioisotopes (Am241 and AmBe), and a larger selection of sensor types. These types of expansions would support SLTT guidance on sensor system recommendations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗

Radiological Consequence Evaluation for Dragonfly Mission

The scoping calculations presented in this report were developed to provide a conservative estimate of radiological dose consequences associated with launch accidents involving one multi-mission radioisotope thermoelectric generator (MMRTG) and possibly up to 43 light-weight radioisotope heater units (LWRHUs) for the upcoming National Aeronautics and Space Administration (NASA) Dragonfly mission. This report summarizes dose consequence analysis from SAND2019-11148, “Nuclear Risk Assessment 2019 Update for the Mars 2020 Mission Environmental Impact Statement,” referred to in this document as the Mars 2020 nuclear risk analysis (NRA) and compares those results to a parametric analysis used to analyze potential dose consequences for the Dragonfly mission.

07 ISOTOPE AND RADIATION SOURCES↗

Development of a military-specific mesh-type computational phantom library and its application to internal dosimetry and in-field radiological triage screening

Estimates of organ-absorbed and committed doses to individuals exposed to radioactive materials via acute inhalation often rely on internal dose coefficients and detector responses from reference human computational models. To achieve more accurate dose assessments to United States Armed Forces service members exposed in-field, computational models with varying morphometric parameters representative of this population are necessary. The International Commission on Radiological Protection (ICRP) Publication 145 provides detailed mesh reference computational phantoms (MRCPs) for adult males and females, with morphometric parameters matched to the 50th percentile. Previously, these phantoms were 2D and 3D scaled to match desired height, mass, and secondary anthropomorphic parameters in the creation of the University of Florida / Memorial Sloan Kettering (UF/MSK) computational phantom library. To achieve body fat percentage targets required for accession into the US Armed Forces, muscle and fat volumes were adjusted accordingly, thus, creating the UF/Department of Defence computational phantom library presented in this study. A comprehensive library of mesh-type computational human phantoms was created, including 57 adult males and 49 adult females with morphometric parameters aligned with United States Armed Forces service members. Phantoms were restricted to a body mass index between 19 and 27.5, with body fat percentages below 26% for males and 36% for females. Specific absorbed fractions were computed for selected source and target combinations, demonstrating how variations in height and body mass influence energy absorption in target regions relative to the ICRP MRCPs. Radiation detector responses were also computed, revealing that higher body masses resulted in decreased registered counts in the detection volume. These findings highlight the importance of incorporating morphometric variability in computational phantoms to achieve more accurate dose assessments and radiation detection responses for United States Armed Forces service members who inhale radioactive materials in-field.

computational phantoms↗

ILLICIT TRANSIT INTERDICTION GLOBAL ANALYSIS

This study aims to enhance the security of radioactive materials during transport by analyzing commonalities in cargo thefts conducted by non-state groups such as thieves and terrorists. This research focuses on identifying patterns and trends in the methods used to steal high-value cargo, with the goal of applying these insights to improve transport security of radioactive materials. Key questions addressed include the frequency of specific tools, techniques, and insider involvement in thefts, as well as the use of weapons, electronic jamming equipment, and specialized tools. Findings will inform security design improvements and industry practices to mitigate vulnerabilities. The study involves a comprehensive review of literature and case studies, utilizing data sources from 2018 to 2023. Articles will be selected based on their relevance to thefts of valuable cargo in transit, with a focus on incidents involving non-state actors. The methodology will include statistical and inferential analysis to identify trends, with results visualized through pie charts, frequency analyses, and terrain maps. The discussion will highlight the implications of findings and provide actionable recommendations for strengthening security measures. Limitations such as data availability and reporting inconsistencies will be acknowledged. Suggestions for future improvements will be constructed using existing case studies and expert feedback. The study’s outcomes aim to raise awareness within the industry, inform policy decisions, and enhance security protocols for radioactive material transport. Metrics for impact include the potential publication of findings, presentations at conferences to raise awareness, and the subsequent actions taken by stakeholders based on the research. By identifying trends and vulnerabilities and suggesting improvements, this research contributes to preventing the illicit use of nuclear and radiological materials.

Zineddin, Dr. Z. [ORNL] (ORCID:0009000848740725)↗

Consequence analyses of sabotage-induced radiological releases in sodium-cooled fast microreactors

Analysis of three sodium-cooled fast microreactors (SFMs) with thermal powers of 10, 30, and 50 MWt showed that smaller reactors result in lower radiological consequences during a postulated sabotage-induced event because of their reduced core inventory. All SFMs used U-10Zr metal fuel enriched to 15 wt% high-assay low-enriched uranium and operated until their respective effective multiplication factor (k eff ) reduced to less than 1 or until the end of their operational lifespan. Sabotage scenarios were simulated at this point, when the fuel inventory within the core contains the highest-level of radioactivity. Radionuclide core inventories were calculated using the SCALE code at shutdown and 3 days post-shutdown. Dose consequence analyses were performed for three sabotage scenarios using the RASCAL tool. As microreactor developers plan for minimal on-site or complete off-site emergency response, it remains essential to evaluate their physical protection needs and potential hazards, including assessing postulated sabotage-induced events that could become more relevant. SFM licensees should identify a credible worst-case, major accident, estimate release source terms, and perform dose consequence analyses to evaluate site-specific physical protection measures. In conclusion, this recommendation supports a risk-informed, performance-based approach, aligning with applicable regulatory requirements, i.e., 10 CFR Parts 100 and 53 rulemaking in the United States.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Screening and Validation of Molecular Targeted Radiosensitizers

The development of molecular targeted drugs with radiation and chemotherapy is critically important for improving the outcomes of patients with hard-to-treat, potentially curable cancers. However, too many preclinical studies have not translated into successful radiation oncology trials. Major contributing factors to this insufficiency include poor reproducibility of preclinical data, inadequate preclinical modeling of intertumoral genomic heterogeneity that influences treatment sensitivity in the clinic, and a reliance on tumor growth delay instead of local control (TCD50) endpoints. There exists an urgent need to overcome these barriers to facilitate successful clinical translation of targeted radiosensitizers. To this end, we have used 3-dimensional (3D) cell culture assays to better model tumor behavior in vivo. Examples of successful prediction of in vivo effects with these 3D assays include radiosensitization of head and neck cancers by inhibiting epidermal growth factor receptor or focal adhesion kinase signaling, and radioresistance associated with oncogenic mutation of KRAS. To address the issue of tumor heterogeneity, we leveraged institutional resources that allow high-throughput 3D screening of radiation combinations with small-molecule inhibitors across genomically characterized cell lines from lung, head and neck, and pancreatic cancers. This high-throughput screen is expected to uncover genomic biomarkers that will inform the successful clinical translation of targeted agents from the National Cancer Institute Cancer Therapy Evaluation Program portfolio and other sources. Screening “hits” need to be subjected to refinement studies that include clonogenic assays, addition of disease-specific chemotherapeutics, target/biomarker validation, and integration of patient-derived tumor models. The chemoradiosensitizing activities of the most promising drugs should be confirmed in TCD50 assays in xenograft models with or without relevant biomarker and using clinically relevant radiation fractionation. We predict that appropriately validated and biomarker-directed targeted therapies will have a higher likelihood than past efforts of being successfully incorporated into the standard management of hard-to-treat tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Source function from two-particle correlation function through entropy-regularized Richardson-Lucy deblurring

Source functions are obtained from p – p and d – α correlation functions by applying the Richardson-Lucy (RL) deblurring to the Koonin-Pratt (KP) equation. To prevent fitting of noise in the correlation function, total-variation (TV) regularization is employed that has been effective in ordinary image restoration. TV alone cannot ensure normalization of the source functions. To ensure the latter, we propose a maximum-entropy regularized RL algorithm (MEM-RL). We outline the MEM-RL formalism and optimization strategy for the KP equation, demonstrating its effectiveness on both simulated and experimental data, including the p – p and d – α correlation functions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Association of Age-Related and Off-Target Retention with Longitudinal Quantification of [ 18 F]MK6240 Tau PET in Target Regions

6-(fluoro- 18 F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([ 18 F]MK6240) tau PET tracer quantifies the brain tau neurofibrillary tangle load in Alzheimer disease. The aims of our study were to test the stability of common reference region estimates in the cerebellum over time and across diagnoses and evaluate the effects of age-related and off-target retention on the longitudinal quantification of [ 18 F]MK6240 in target regions. Methods: We assessed reference, target, age-related, and off-target regions in 125 individuals across the aging and Alzheimer disease spectrum with longitudinal [ 18 F]MK6240 SUVs and SUV ratios (SUVRs) (mean ± SD, 2.25 ± 0.40 y of follow-up). We obtained SUVR from meninges, exhibiting frequent off-target retention with [ 18 F]MK6240. Additionally, we compared tracer uptake between 37 cognitively unimpaired young (CUY) (mean age, 23.41 ± 3.33 y) and 27 cognitively unimpaired older (CU) adults (amyloid-β–negative and tau-negative, 58.50 ± 9.01 y) to identify possible nonvisually apparent, age-related signal. Two-tailed t testing and Pearson correlation testing were used to determine the difference between groups and associations between changes in region uptake, respectively. Results: Inferior cerebellar gray matter SUV did not differ on the basis of diagnosis and amyloid-β status, cross-sectionally and over time. [ 18 F]MK6240 uptake significantly differed between CUY and CU adults in the putamen or pallidum (affecting ~75% of the region) and in the Braak II region (affecting ~35%). Changes in meningeal and putamen or pallidum SUVRs did not significantly differ from zero, nor did they vary across diagnostic groups. We did not observe significant correlations between longitudinal changes in age-related or meningeal off-target retention and changes in target regions, whereas changes in all target regions were strongly correlated. Conclusion: Inferior cerebellar gray matter was similar across diagnostic groups cross-sectionally and stable over time and thus was deemed a suitable reference region for quantification. Despite not being visually perceptible, [ 18 F]MK6240 has age-related retention in subcortical regions, at a much lower magnitude but topographically colocalized with significant off-target signal of the first-generation tau tracers. The lack of correlation between changes in age-related or meningeal and target retention suggests little influence of possible off-target signals on longitudinal tracer quantification. Nevertheless, the age-related retention in the Braak II region needs to be further investigated. Future postmortem studies should elucidate the source of the newly reported age-related [ 18 F]MK6240 signal, and in vivo studies should further explore its impact on tracer quantification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗