Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RUBIDIUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A feasibility study of ion implantation techniques for mass spectrometer calibration

An experimental study was undertaken to examine the feasibility of using ion-implanted filaments doped with either an alkali metal or noble gas for in situ recalibration of onboard mass spectrometers during extended space missions. Implants of rubidium and krypton in rhenium ribbon filaments were subsequently tested in a bakeable 60 deg sector mass spectrometer operating in the static mode. Surface ionization and electron impact ion sources were both used, each yielding satisfactory results. The metallic implant with subsequent ionization provided a means of mass scale calibration and determination of system operating parameters, whereas the noble gas thermally desorbed into the system was more suited for partial pressure and sensitivity determinations.

Koslin, M. E.↗

Response of the iron-deficient erythrocyte in the rat to hyperoxia

Normal and iron-deficient rats were exposed to 90% O2 at 760 Torr for 24 or 48 h. Erythrocyte response to hyperoxia was monitored by potassium (rubidium) influx studies, by storage stress, and by ultrastructural studies. Normal rat erythrocytes exhibited morphological changes and decrease of ouabain-sensitive potassium influx compared to unexposed controls. Both components of erythrocyte potassium influx were affected by iron deficiency. Erythrocytes from unexposed iron-deficient rats showed a 50% increase in ouabain-sensitive potassium influx compared to controls. Iron-deficient rats exposed to hyperoxia for 24 or 48 h, had erythrocytes with morphological changes. Erythrocytes of iron-deficient rats exposed for 24 h showned no influx change; those exposed for 48 h showed a decrease of ouabain-sensitive influx compared to erythrocytes of controls.

Larkin, E. C.↗

Bonding of sapphire to sapphire by eutectic mixture of aluminum oxide and zirconium oxide

An element comprising sapphire, ruby or blue sapphire can be bonded to another element of such material with a eutectic mixture of aluminum oxide and zirconium oxide. The bonding mixture may be applied in the form of a distilled water slurry or by electron beam vapor deposition. In one embodiment the eutectic is formed in situ by applying a layer of zirconium oxide and then heating the assembly to a temperature above the eutectic temperature and below the melting point of the material from which the elements are formed. The formation of a sapphire rubidium maser cell utilizing eutectic bonding is shown.

Deluca, J. J.↗

The trapped mercury ion frequency standard

Singly ionized mercury atoms have a structure similar to neutral alkali atoms. They can be maintained as ions for very long times in an RF quadrupole ion trap. Thus, their ground state hyperfine structure can be used to make a frequency standard using optical pumping techniques similar to the well-known rubidium standard. The mass 199 isotope of mercury has an ionic hyperfine structure of 40.5 GHz. In a trap system a linewidth of 10 Hz has been measured. An expression is presented for the short-term stability of a proposed mercury standard as set by the achieved signal to noise ratio. There is prospect of further improvement. Long-term stability is affected by second order doppler effect, and by pressure, light, and Stark shifts. However, these appear either sufficiently small or sufficiently controlable that the proposed mercury ion standard would be competitive with existing standards.

Mcguire, M. D.↗

Response of the rat erythrocyte to ozone exposure

Sprague-Dawley rats were exposed to high (6-8 ppm) and moderate (1.5 ppm) amounts of ozone (O3) for various time periods. Response of the rat erythrocyte to ozone was monitored with red blood cell potassium (rubidium) influx studies, with storage stress combined with ultrastructural studies and with levels of erythrocyte glutathione peroxidase and superoxide dismutase. Erythrocytes of rats exposed to O3 showed no significant changes either in their potassium influx or in their glutathione peroxidase and superoxide dismutase activities compared to controls. Erythrocyte differential counts on O3-exposed animals showed significant changes initially as well as following storage stress compared to controls. Rats exposed to 8 ppm O3 for 4 h showed a marked increase in echinocytes. These consistent transformations from discocytes to echinocytes following O3 exposure suggest latent erythrocyte damage has occurred.

Larkin, E. C.↗

Precise time and Time Interval (PTTI) measurements from the navigation technology satellites and the GPS NAVSTAR-4 satellite

A time domain estimate for the NAVSTAR-4 SV clock offset was obtained for each SV pass over the GPS monitor sites, using a smoothed reference ephemeris, with corrections for ionospheric delay, tropospheric delay, earth rotation and relativistic effects. Conversion from the time domain to the frequency domain was made using the two sample Allan Variance; sigma-tau plots used to identify the noise processes. Estimates of flicker and white frequency noise for the NAVSTAR-4 rubidium frequency standard were obtained. The contribution of the reference ground clocks and other error sources to the frequency stability estimates were also considered.

Buisson, J. A.↗

Prospects for advances in microwave atomic frequency standards

Traditional standards based on rubidium, cesium and hydrogen have been greatly refined over the past decade, such that the frequency stability of the current generation of devices is generally limited by those basic concepts on which they are based. Future advances in frequency stability will principally come from changes in the concepts on which the standards are based, and only secondarily from more careful engineering of the old concepts. The fundamental limitations in these standards are considered and the important conceptual and component advances which could have a major impact on future performance of these standards are indicated. A very promising new class of microwave standards based on ion storage techniques is examined.

Walls, F. L.↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Alkali metal vapors - Laser spectroscopy and applications

The paper examines the rapidly expanding use of lasers for spectroscopic studies of alkali metal vapors. Since the alkali metals (lithium, sodium, potassium, rubidium and cesium) are theoretically simple ('visible hydrogen'), readily ionized, and strongly interacting with laser light, they represent ideal systems for quantitative understanding of microscopic interconversion mechanisms between photon (e.g., solar or laser), chemical, electrical and thermal energy. The possible implications of such understanding for a wide variety of practical applications (sodium lamps, thermionic converters, magnetohydrodynamic devices, new lasers, 'lithium waterfall' inertial confinement fusion reactors, etc.) are also discussed.

Stwalley, W. C.↗

Innovation and reliability of atomic standards for PTTI applications

Innovation and reliability in hyperfine frequency standards and clock systems are discussed. Hyperfine standards are defined as those precision frequency sources and clocks which use a hyperfine atomic transition for frequency control and which have realized significant commercial production and acceptance (cesium, hydrogen, and rubidium atoms). References to other systems such as thallium and ammonia are excluded since these atomic standards have not been commercially exploited in this country.

Kern, R.↗

Contractor point of view for system development and test program

Industry's practice of testing space qualified hardware is examined. An overview of the Global Positioning System (GPS) Test Program is discussed from the component level to the sub-system compatibility tests with the space vehicle and finally to the launch site tests, all related to the Rubidium clock.

Koide, F. K.↗

PTTI applications at Hydro-Quebec

As a power utility, Hydro-Quebec used the PTTI techniques. The time dissemination system in the Hydro-Quebec Network (11th PTTI) is now installed in several points. A portable clock was built using a rubidium standard and associated circuitry which are necessary for the measurements. The apparatus and the experimental results obtained are described. The use of GOES synchronized clocks for making precise voltage angle measurement on the Hydro-Quebec Network is discussed. Some modifications were made on a commercial unit. Applications and results are presented.

Missout, G.↗

The role of precise time in IFF

The application of precise time to the identification of friend or foe (IFF) problem is discussed. The simple concept of knowing when to expect each signal is exploited in a variety of ways to achieve an IFF system which is hard to detect, minimally exploitable and difficult to jam. Precise clocks are the backbone of the concept and the various candidates for this role are discussed. The compact rubidium-controlled oscillator is the only practical candidate.

Bridge, W. M.↗

Frequency stability of maser oscillators operated with cavity Q

The short term frequency stability of masers equipped with an external feedback loop to increase the cavity quality factor was studied. The frequency stability of a hydrogen and a rubidium maser were measured and compared with theoretical evaluation. It is shown that the frequency stability passes through an optimum when the cavity Q is varied. Long term fluctuations are discussed and the optimum mid term frequency stability achievably by small size active and passive H-masers is considered.

Tetu, M.↗

One nanosecond time synchronization using series and GPS

Subnanosecond time sychronization between two remote rubidium frequency standards is verified by a traveling clock comparison. Using a novel, code ignorant Global Positioning System (GPS) receiver developed at JPL, the SERIES geodetic baseline measurement system is applied to establish the offset between the 1 Hz. outputs of the remote standards. Results of the two intercomparison experiments to date are presented as well as experimental details.

Buennagel, A. A.↗

Mapping the earth's magnetic and gravity fields from space Current status and future prospects

The principal magnetic fields encountered by earth orbiting spacecraft include the main (core) field, external fields produced by electrical currents within the ionosphere and magnetosphere, and the crustal (anomaly) field generated by variations in the magnetization of the outermost portions of the earth. The first orbital field measurements which proved to be of use for global studies of crustal magnetization were obtained by a series of three satellites launched and operated from 1965 to 1971. Each of the satellites, known as a Polar Orbiting Geophysical Observatory (POGO), carried a rubidium vapor magnetometer. Attention is also given to Magsat launched in 1979, the scalar anomaly field derived from the Magsat measurements, satellite tracking studies in connection with gravity field surveys, radar altimetry, the belt of positive free air gravity anomalies situated along the edge of the Pacific Ocean basin, future technological capabilities, and information concerning data availability.

Settle, M.↗

Frequency standards for VLBI, present and future

During the last several years, J.P.L. has evaluated a number of different types of frequency standards. These evaluations include measurement of environmetal susceptibilities (barometric pressure, humidity, temperature and magnetic field) and evaluation of stability. Data from these tests are presented for quartz oscillators, rubidium vapor standards, cesium beam standards, hydrogen masers (active and passive) and a superconducting cavity stabilized oscillator. Data on reliability and mechanical ruggedness based on actual field use is also presented. A survey of new frequency standards, their likely performance and environmental characteristics is presented.

Sydnor, R. L.↗