Oxide Protective Coats for Ir/Re Rocket Combustion Chambers

An improved material system has been developed for rocket engine combustion chambers for burning oxygen/ hydrogen mixtures or novel monopropellants, which are highly oxidizing at operating temperatures. The baseline for developing the improved material system is a prior iridium/rhenium system for chambers burning nitrogen tetroxide/monomethyl hydrazine mixtures, which are less oxidizing. The baseline combustion chamber comprises an outer layer of rhenium that provides structural support, plus an inner layer of iridium that acts as a barrier to oxidation of the rhenium. In the improved material system, the layer of iridium is thin and is coated with a thermal fatigue-resistant refractory oxide (specifically, hafnium oxide) that serves partly as a thermal barrier to decrease the temperature and thus the rate of oxidation of the rhenium. The oxide layer also acts as a barrier against the transport of oxidizing species to the surface of the iridium. Tests in which various oxygen/hydrogen mixtures were burned in iridium/rhenium combustion chambers lined with hafnium oxide showed that the operational lifetimes of combustion chambers of the improved material system are an order of magnitude greater than those of the baseline combustion chambers.

Fortini, Arthur↗

Low-Cost, High-Performance Combustion Chamber

Ultramet designed and fabricated a lightweight, high-temperature combustion chamber for use with cryogenic LOX/CH4 propellants that can deliver a specific impulse of approx.355 seconds. This increase over the current 320-second baseline of nitrogen tetroxide/monomethylhydrazine (NTO/MMH) will result in a propellant mass decrease of 55 lb for a typical lunar mission. The material system was based on Ultramet's proven oxide-iridium/rhenium architecture, which has been hot-fire tested with stoichiometric oxygen/hydrogen for hours. Instead of rhenium, however, the structural material was a niobium or tantalum alloy that has excellent yield strength at both ambient and elevated temperatures. Phase I demonstrated alloys with yield strength-to-weight ratios more than three times that of rhenium, which will significantly reduce chamber weight. The starting materials were also two orders of magnitude less expensive than rhenium and were less expensive than the C103 niobium alloy commonly used in low-performance engines. Phase II focused on the design, fabrication, and hot-fire testing of a 12-lbf thrust class chamber with LOX/CH4, and a 100-lbf chamber for LOX/CH4. A 5-lbf chamber for NTO/MMH also was designed and fabricated.

Fortini, Arthur J.↗

Influence of Metal Ion Complexation on the Radiolytic Longevity of Butyramide Extractants under Direct Dissolution Process Conditions

The direct dissolution of voloxidized used nuclear fuel (UNF) into an organic solution–comprised of diluent and specialized extractants–poses a promising alternative to the traditional liquid–liquid solvent extraction approach to reprocessing UNF. However, moving to direct dissolution removes the presence of a concentrated nitric acid aqueous phase, which has been shown to significantly influence the radiolytic longevity of extractants in conventional extraction flowsheets. Given the limited knowledge of radiation effects under direct dissolution conditions, here we present a time-resolved and dose-accumulation study on the impact of direct dissolution conditions on the radiolytic longevity of two candidate butyramide extractants, N,N-di(2-ethylhexyl) butyramide (DEHBA) and N,N-di(2-ethylhexyl)isobutyramide (DEHiBA), in pre-equilibrated n-dodecane solvent in the presence and absence of process-relevant metal ions, specifically, uranium and rhenium. Loss G(DEHBA) and G(DEHiBA) values were found to be comparable to each other, with an average of 0.37 ± 0.02 μmol J –1 , and to previous data from the γ irradiation of DEHBA and DEHiBA under conventional solvent extraction conditions. Rhenium, and by extension technetium, extraction had a modest decrease (~10%) in the overall radiolytic stability of DEHiBA only, despite >2× observed increases in chemical kinetic reactivity of the corresponding complexes with the n-dodecane radical cation. Uranium loading, on the other hand, significantly improved the lifetime of both ligands (>30%) under γ irradiation, with a greater stabilization observed for DEHBA over DEHiBA. The observed radioprotective effect afforded by uranium loading is fortuitous for the longevity of direct dissolution solvent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Influence of metal ion complexation on the radiolytic longevity of butyramide extractants under direct dissolution conditions

The direct dissolution of volox-treated used nuclear fuel (UNF) into an organic solution—comprised of diluent and specialized extractants—poses a promising alternative to the traditional liquid-liquid solvent extraction approach to reprocessing UNF. However, moving to direct dissolution removes the presence of a concentrated nitric acid aqueous phase, which has been shown to significantly influence the radiolytic longevity of extractants in liquid-liquid solvent extraction flowsheets. With this in mind, and given the limited knowledge of radiation effects under direct dissolution conditions, we present a time-resolved and dose accumulation study on the impact of direct dissolution conditions on the radiolytic longevity of two candidate butyramide extractants—N,N-di-(2-ethylhexyl) butyramide (DEHBA) and N,N-di-(2-ethylhexyl)isobutyramide (DEHiBA)—in pre-equilibrated n-dodecane solvent in the presence and absence of process relevant metal ions, uranium and rhenium. Rhenium, and by extension technetium, extraction had little impact (=10%) on the overall radiolytic stability of these ligands, despite observed increases in chemical kinetic reactivity (>2×) of the corresponding complexes with the n-dodecane radical cation. Uranium-loading on the other hand, significantly improved the lifetime of both ligands (>30%) under gamma irradiation, with a greater stabilization observed for DEHBA over DEHiBA. This draft manuscript has been prepared in fulfillment of NTRD-MRWFD-2024 M3FT-24IN030101115.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Functionalized Magnetic Nanoparticles for Technetium Sequestration from Groundwater

Technetium 99 (Tc) is among the most common environmental contaminants at DOE sites and one of the most common risk drivers in low- and high-level waste disposal sites. The majority of Tc is generated from anthropogenic sources, such as nuclear power plants, global weapons, nuclear storage facilities and medical applications. Through these sources, Tc contamination has been unintentionally introduced in to the environment. The most common chemical form of Tc is Tc(VII)O{sub 4}{sup -}. Due to its high solubility and mobility, Tc can enter the food chain and cause adverse health effects to humans. Currently, ion exchange resins and reduction processes are the most common approaches for Tc immobilization. Although these techniques have shown to be effective, they also possess major drawbacks, such as high cost, low adsorption capacity, and complex creation and maintenance. Therefore, development of more efficient and simple technologies for the remediation of Tc-contaminated systems are needed. Functionalized magnetic nanoparticles have been used to remove organic and inorganic contaminants from water resources. These nanoparticles have attracted extensive attention as an adsorbent material due to their large surface area, high efficiency, low-cost, easy functionalization and separation with a magnet. This study seek to develop functionalized magnetic iron oxide nanoparticles for the efficient removal of Tc and other heavy metal contaminants from water resources under ambient conditions. Objectives: Synthesize magnetic iron oxide nanoparticles and functionalize their surface with Cetyltrimethylammonium Bromide (CTAB) and tetraethyl-orthosilicate (TEOS). Characterize the synthesized nanoparticles using scanning electron microscopy (SEM) coupled with energy dispersive X-ray spectroscopy (EDS), Dynamic Light Scattering (DLS) and Zeta PALS. Perform adsorption studies to evaluate their adsorption behavior and capacity for (a) Technetium using Rhenium (ReO{sub 4}{sup -}) as a surrogate and (b) heavy metals, e.g. Cu{sup 2+}. Conclusions: Magnetic iron oxide nanoparticles were successfully functionalized with CTAB and TEOS. The functionalization of the iron oxide nanoparticles affects their surface charge and their hydrodynamic diameter. The addition of CTAB or TEOS decreased the hydrodynamic diameter of the nanoparticles due to repulsive and steric forces. The SEM micrographs show spherical nanoparticles of different sizes. The EDX analysis shows the presence of iron and oxygen from the iron oxide crystalline structure, and the different constituents of the CTAB and TEOS molecules. Proof-of-concept shows the successful adsorption of rhenium (ReO{sub 4}{sup -}) and copper Cu{sup 2+}) onto CTAB-Fe{sub 2}O{sub 3} and TEOS-Fe{sub 2}O{sub 3} respectively.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nondestructive measurements of residual 235 U mass of Israeli Research Reactor-1 fuel using the Advanced Experimental Fuel Counter

In 2018, a measurement campaign took place with participants from Los Alamos National Laboratory (LANL), the Nuclear Research Centre-Negev (NRCN) and Soreq Nuclear Research Center (SNRC) at the Israeli Research Reactor-1 (IRR-1) in which 14 of the reactor’s used fuel assemblies (FAs) with varied amount of depletion were measured with the nondestructive assay instrument Advanced Experimental Fuel Counter (AEFC). Designed for safeguards purposes, the AEFC measures both neutrons emitted from the FA (passive neutrons) and fission neutrons induced by an external neutron source (in this experiment, 252 Cf). Signals recorded with the AEFC include total neutron count rates (Singles), time-correlated neutron count rates (Doubles), and total gamma-ray count rates. The 235 U content of the FAs was previously assessed by two independent methods: (1) measurement of the transparency of the FA to low-energy gamma rays from an activated rhenium source (rhenium gamma transmission, or the RGT method) and (2) calculation of the 30-year burnup history of the core using detailed three-dimensional Monte-Carlo core depletion calculations. The results from the FAs that had been measured via the RGT method were used to construct the calibration curves, which translate the AEFC count rates to 235 U mass. Then, the calibration was evaluated using AEFC measurements of six additional FAs that were not measured via the RGT method. From the results, it was determined the Doubles calibration curve was more reliable than that of the Singles and follows a simple second-order polynomial fit for the whole range of residual 235 U mass content, albeit with larger statistical uncertainty. Detailed uncertainties quantification was conducted for both the AEFC Singles and Doubles. This includes the analysis of statistical uncertainties, calibration uncertainty, and random uncertainties due to the sensitivity of the AEFC to several sources of uncertainty, namely the FA position, FA orientation, interrogation source position, and ambient pool temperature. Finally, an overall total uncertainty of 6 g of 235 U is estimated for the Singles and Doubles, which is mainly due to calibration uncertainty (for the Singles) and statistical uncertainty (for the Doubles), and which constitutes 3%–6% of the 235 U total mass in the FAs, depending on their level of depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Materials synthesis at terapascal static pressures

Theoretical modelling predicts very unusual structures and properties of materials at extreme pressure and temperature conditions. Hitherto, their synthesis and investigation above 200 gigapascals have been hindered both by the technical complexity of ultrahigh-pressure experiments and by the absence of relevant in situ methods of materials analysis. Here we report on a methodology developed to enable experiments at static compression in the terapascal regime with laser heating. We apply this method to realize pressures of about 600 and 900 gigapascals in a laser-heated double-stage diamond anvil cell, producing a rhenium–nitrogen alloy and achieving the synthesis of rhenium nitride Re 7 N 3 —which, as our theoretical analysis shows, is only stable under extreme compression. Full chemical and structural characterization of the materials, realized using synchrotron single-crystal X-ray diffraction on microcrystals in situ, demonstrates the capabilities of the methodology to extend high-pressure crystallography to the terapascal regime.

36 MATERIALS SCIENCE↗

Low-energy electronic interactions in ferrimagnetic Sr 2 CrReO 6 thin films

We reveal in this study the fundamental low-energy landscape in the ferrimagnetic Sr 2 CrReO 6 double perovskite and describe the underlying mechanisms responsible for the three low-energy excitations below 1.4 eV. Here, based on resonant inelastic x-ray scattering and magnetic dynamics calculations, and experiments collected from both Sr 2 CrReO 6 powders and epitaxially strained thin films, we reveal a strong competition between spin-orbit coupling, Hund’s coupling, and the strain-induced tetragonal crystal field. Here, we also demonstrate that a spin-flip process is at the origin of the lowest excitation at 200 meV, and we bring insights into the predicted presence of orbital ordering in this material. We study the nature of the magnons through a combination of ab initio and spin-wave theory calculations, and show that two nondegenerate magnon bands exist and are dominated either by rhenium or chromium spins. The rhenium band is found to be flat at about 200 meV (±25 meV) through X-L-W-U high-symmetry points and is dispersive toward Γ.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mechanical properties of electron-beam-melted molybdenum and dilute Mo-Re alloys.

Study of Mo-Re alloys aimed at examining the effects of small rhenium additions on the low-temperature ductility of molybdenum and determining the mechanical properties of dilute Mo-Re alloys. The results obtained indicate that high-purity Mo-Re alloys have ductile-brittle transition temperatures considerably lower than those for unalloyed molybdenum and that rhenium promotes normal solid-solution strengthening in molybdenum at elevated temperatures.

Klopp, W. D.↗

Recent progress in hybrid mode thermionic converter development

Thermionic research has been conducted to investigate a hybrid-mode thermionic converter as a candidate for reducing the barrier index. The hybrid-mode thermionic converter is designed to operate in a combination ignited mode and unignited mode by using a series of parallel grooves in the emitter. The emitter material is molybdenum and the non-grooved land area is thinly coated with rhenium metal. When the emitter is exposed to cesium vapor, as it is during the converter operation, the rhenium-coated land area achieves a lower work function than the grooved molybdenum surface by as much as 0.5 eV. The low work function land area provides a major portion of electron emission, and the high work function grooved area provides cesium ions required for efficient transport of electrons generated in adjacent land areas to the collector. Experimental results obtained from two different converters and a numerical analysis of converter characteristics are presented in this paper.

Shimada, K.↗

Low cost cylindrical converter for measuring lead efficiency

A low cost cylindrical thermionic converter has been designed, fabricated, and tested for use in a NASA-JPL program to directly measure converter lead efficiencies using various electrode materials and surfaces. Efficiency measurements are made using input emitter heater power, output power at the leads, and calculated values of the parasitic losses that would not be present in the application configuration. This information can be used to predict the performance characteristics of the advanced converters currently under development. A series of five converters has been tested. Both structured and smooth molybdenum collectors have been used. Emitters included smooth molybdenum, smooth rhenium, and microstructured rhenium. Cesium pressure families of current-voltage curves are presented for emitter temperatures of 1600, 1700, and 1800 K, along with measured efficiencies as a function of converter current densities for each temperature.

Hatch, G. L.↗

Calculation of vaporization rates assuming various rate determining steps: Application to the resistojet

The various steps that could control the vaporization rate of a material are discussed. These steps include the actual vaporization, flow rate of matrix gas, chemical reaction, gas diffusion, and solid state diffusion. The applicable equations have been collected from diverse appropriate sources, and their use is explained. Rate equations are derived for conditions where more than one step is rate controlling. Calculations are made for two model materials: rhenium which vaporizes congruently, and tantalum carbide which vaporizes incongruently. The case of vaporization under thermal gradient conditions is also treated. The existence of a thermal gradient in the resistojet means that the vaporization rate of a material may be only one thousandth of that predicted under isothermal conditions. Calculations show that rhenium might have a 100,000 hr lifetime at temperature in a 2500 C resistojet. Tantalum carbide would have a life of only 660 sec under similar conditions.

May, C. E.↗

Real-time measurement of sodium chloride in individual aerosol particles by mass spectrometry

The method of particle analysis by mass spectrometry has been applied to the quantitative measurement of sodium chloride in individual particles on a real-time basis. Particles of known masses are individually introduced, in the form of a beam, into a miniature Knudsen cell oven (1600 K). The oven is fabricated from rhenium metal sheet (0.018 mm thick) and is situated in the ion source of a quadrupole mass spectrometer. A particle once inside the oven is trapped and completely volatilized; this overcomes the problem of partial volatilization due to particles bouncing from the filament surface. Individual particles are thermally volatilized and ionized inside the rhenium oven, and produce discrete sodium ion pulses whose intensities are measured with the quadrupole mass spectrometer. An ion pulse width of several milliseconds (4-12 ms) is found for particles in the mass range 1.3 x 10 to the -13th to 5.4 x 10 to the -11th g. The sodium ion intensity is found to be proportional to the particle mass to the 0.86-power. The intensity distribution for monodisperse aerosol particles possesses a geometric standard deviation of 1.09, showing that the method can be used for the determination of the mass distribution function with good resolution in a polydisperse aerosol.

Sinha, M. P.↗

Arcjet cathode phenomena

Cathode tips made from a number of different materials were tested in a modular arcjet thruster in order to examine cathode phenomena. Periodic disassembly and examination, along with the data collected during testing, indicated that all of the tungsten-based materials behaved similarly despite the fact that in one of these samples the percentage of thorium oxide was doubled and another was 25 percent rhenium. The mass loss rate from a 2 percent thoriated rhenium cathode was found to be an order of magnitude greater than that observed using 2 percent thoriated tungsten. Detailed analysis of one of these cathode tips showed that the molten crater contained pure tungsten to a depth of about 150 microns. Problems with thermal stress cracking were encountered in the testing of a hafnium carbide tip. Post test analysis showed that the active area of the tip had chemically reacted with the propellant. A 100 hour continuous test was run at about 1 kW. Post test analysis revealed no dendrite formation, such as observed in a 30 kW arcjet lifetest, near the cathode crater. The cathodes from both this test and a previously run 1000 hour cycled test displayed nearly identical arc craters. Data and calculations indicate that the mass losses observed in testing can be explained by evaporation.

Curran, Francis M.↗

Arcjet Cathode Phenomena

Cathode tips made from a number of different materials were tested in a modular arcjet thruster in order to examine cathode phenomena. Periodic disassembly and examination, along with the data collected during testing, indicated that all of the tungsten-based materials behaved similarly despite the fact that in one of these samples the percentage of thorium oxide was doubled and another was 25 percent rhenium. The mass loss rate from a 2 percent thoriated rhenium cathode was found to be an order of magnitude greater than that observed using 2 percent thoriated tungsten. Detailed analysis of one of these cathode tips showed that the molten crater contained pure tungsten to a depth of about 150 microns. Problems with thermal stress cracking were encountered in the testing of a hafnium carbide tip. Post test analysis showed that the active area of the tip had chemically reacted with the propellant. A 100 hour continuous test was run at about 1 kW. Post test analysis revealed no dendrite formation, such as observed in a 30 kW arcjet lifetest, near the cathode crater. The cathodes from both this test and a previously run 1000 hour cycled test displayed nearly identical arc craters. Data and calculations indicate that the mass losses observed in testing can be explained by evaporation.

Curran, Francis M.↗

Space Shuttle vernier thruster long-life chamber development

The Space Shuttle Reaction Control Subsystem (RCS) vernier thruster is a pressure fed engine that utilizes storable propellants to provide precise attitude control for the Orbiter. The current vernier thruster is life limited due to its chamber material. By developing an iridium-lined rhenium chamber for the vernier, substantial gains could be achieved in the operational life of the chamber. The present RCS vernier, its requirements, operating characteristics, and life limitations are described. The current technology status of iridium-lined rhenium is presented along with a description of the operational life capabilities to be gained from implementing this material into the design of a long life vernier chamber. Discussion of the proposed demonstration program to be performed by the NASA Lyndon B. Johnson Space Center to attain additional insight into the application of this technology to the RCS vernier, includes the technical objectives, approach, and program schedule. The plans for further development and integration with the Orbiter and the Shuttle system are also presented.

Krohn, Douglas D.↗

High temperature oxidation-resistant thruster research

A program was conducted for NASA-LeRC by Aerojet Propulsion Division to establish the technology base for a new class of long-life, high-performance, radiation-cooled bipropellant thrusters capable of operation at temperatures over 2200 C (4000 F). The results of a systematic, multi-year program are described starting with the preliminary screening tests which lead to the final material selection. Life greater than 15 hours was demonstrated on a workhorse iridium-lined rhenium chamber at chamber temperatures between 2000 and 2300 C (3700 and 4200 F). The chamber was fabricated by the Chemical Vapor Deposition at Ultramet. The program culminated in the design, fabrication, and hot-fire test of an NTO/MMH 22-N (5-lbF) class thruster containing a thin wall iridium-lined rhenium thrust chamber with a 150:1 area ratio nozzle. A specific impulse of 310 seconds was measured and front-end thermal management was achieved for steady state and several pulsing duty cycles. The resulting design represents a 20 second specific impulse improvement over conventional designs in which the use of disilicide coated columbium chambers limit operation to 1300 C (2400 F).

Wooten, John R.↗

High temperature thruster technology for spacecraft propulsion

A technology program intended to develop high-temperature oxidation-resistant thrusters for spacecraft applications is considered. The program will provide the requisite material characterizations and fabrication to incorporate iridium coated rhenium material into small rockets for spacecraft propulsion. This material increases the operating temperature of thrusters to 2200 C, a significant increase over the 1400 C of the silicide-coated niobium chambers currently used. Stationkeeping class 22 N engines fabricated from iridium-coated rhenium have demonstrated steady state specific impulses 20-25 seconds higher than niobium chambers. These improved performances are obtained by reducing or eliminating the fuel film cooling requirements in the combustion chamber while operating at the same overall mixture ratio as conventional engines.

Schneider, Steven J.↗