Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REMOVAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Using GC-FID to Quantify the Removal of 4-sec-Butylphenol from NGS Solvent by NaOH

A caustic wash of the solvent used in the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process was found to remove the modifier breakdown product 4-sec-butylphenol (SBP) with varying efficiency depending on the aqueous NaOH concentration. Recent efforts at ORNL have aimed at characterizing the flowsheet chemistry and reducing the technical uncertainties of the NG-CSSX process. One technical uncertainty has been the efficacy of caustic washing of the solvent for the removal of lipophilic anions, in particular, the efficient removal of SBP, an important degradation product of the solvent modifier, Cs-7SB. In order to make this determination, it was necessary to develop a sensitive and reliable analytical technique for the detection and quantitation of SBP. This report recounts the development of a GC-FID-based (Gas Chromatography Flame Ionization Detection) technique for analyzing SBP and the utilization of the technique to subsequently confirm the ability of the caustic wash to efficiently remove SBP from the Next Generation Solvent (NGS) used in NG-CSSX. In particular, the developed technique was used to monitor the amount of SBP removed from a simple solvent and the full NGS by contact with sodium hydroxide wash solutions over a range of concentrations. The results show that caustic washing removes SBP with effectively the same efficiency as it did in the original Caustic-Side Solvent Extraction (CSSX) process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing reliable safeguards seals for application verification and removal by State operators

Once a geological repository has begun operations, the encapsulation and disposal of spent fuel will be performed as a continuous, industrial-scale series of processes, during which time safeguards seals will be applied to transportation casks before shipment from an encapsulation plant, and then verified and removed following receipt at the repository. These operations will occur approximately daily during several decades of Sweden's repository operation; however, requiring safeguards inspectors to perform the application, verification, and removal of every seal would be an onerous burden on International Atomic Energy Agency's (IAEA's) resources. Current IAEA practice includes allowing operators to either apply seals or remove them, but not both, so the daily task of either applying or verifying and removing would still require continuous presence of IAEA inspectors at one site at least. Of special importance is the inability to re-verify cask or canisters from which seals have been removed and the canisters emplaced underground. Successfully designing seals that can be applied, verified and removed by an operator with IAEA approval could impact more than repository shipments, but other applications as well, potentially reducing inspector burdens for a wide range of such duties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank Closure Cesium Removal Project CST Simulant Cesium Batch Contact Kinetics Test Results and Column Performance Predictions

To evaluate the cesium removal capabilities of the caustic-washed R9120-B version of crystalline silicotitanate (CST) ion exchange media from Savannah River Site (SRS) waste during Tank Closure Cesium Removal (TCCR) column processing, batch contact kinetics tests were performed at 23 °C in SRS Average simulant. Cesium loading kinetics data was also collected (in current and previous testing; King, et al., 2018a) using the same simulant for an older CST sample (IE- 911) which was caustic-washed by the vendor many years ago and was recently retrieved from drums stored at SRS. (Note that R9120-B and IE-911 are believed to be identical materials, after the R9120-B was caustic washed by SRNL, and differ only by particle size and manufacturing date, and thus can be considered different batches). Although cesium loading kinetics testing can be conducted more rigorously using dynamic column tests, the batch contact method requires less simulant and considerably less experimental effort. Average percent removal data for batch contact samples for the two CST batches are provided in Table ES-1. Faster cesium uptake was observed with IE-911, although the loading rates for the two media batches were similar. After 5.5 hours of CST contact, 81% cesium removal was observed with R9120-B versus 86% removal with IE-911. Although these differences are small, the trend is consistent across the timed results, with the larger bead material always loading slower. These seemingly small differences in percent removal are believed to have a large impact on the column performance. Cesium loading curves for the two CST batches are provided in Figure ES-1 below. Faster cesium loading with IE-911 CST is presumed to be associated with the smaller average particle diameter (408 μm mean volume diameter) versus R9120-B (572 μm diameter). Cesium loading kinetic data was needed to conduct column performance comparisons (i.e., model predictions) for the two CST batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Options for the Removal of Cesium and Strontium from Acidic Uranyl Sulfate Solutions from Molybdenum-99 Production

A small laboratory-scale column process aimed at removing fission products from prototypical acidic sulfate solution wastes from a prototypical Mo-99 recovery process has been operated in a radioactive materials hood at Savannah River National Laboratory. This equipment has been operated with realistic concentrations of uranium (0.4 wt % 235 U), plutonium ( 239 Pu), neptunium ( 237 Np), non-radioactive surrogates of common fission products (including Cs and Sr) and two promising absorbents AMP-PAN and CST R91290-B. The goal of this work was to demonstrate the removal and concentration of high specific activity isotopes which are expected to dominate the classification of the low-level waste from the production of 99 Mo. Both AMP-PAN and CST R9120-B are attractive absorbents for the removal of 137 Cs from an acidic sulfate waste stream. They do not provide a solution for the removal of 90 Sr from the acidic solutions, but CST should be investigated at a higher pH. Limited removal of transuranic species and almost no removal of uranium was observed in this testing. This could be important due to the relatively large amount of uranium expected to be present in such waste streams. The capacity of these absorbents for 137 Cs will likely be dependent on the Cs concentration in the solutions processed but loading in the range of 0.2 to 5 mg Cs per gram of absorbent appears to be achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cesium Removal from Surrogate Pyroprocessing Salt by Electrodeposition

Active metals in used nuclear fuel dissolve into the salt during pyroprocessing and are not removed by electrorefining or drawdown operations. The buildup of 137 Cs over time increases the heat load and ionizing radiation level of the salt such that it must be replaced frequently, resulting in a significant amount of salt waste. An effective means of managing cesium in the molten salt electrolyte would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal. A previous report summarized issues that must be addressed when developing a removal strategy and assessed the suitability of existing methods and remaining technological gaps to their application (Rose and Thomas 2023). Cesium is extremely stable in molten salt as a chloride—even more stable than the LiCl-KCl eutectic base salt used for pyroprocessing fuel—which makes removing cesium a challenge. However, sufficiently strong atomic interactions occur between active metal species and liquid metals that make the electrodeposition of active metal fission products into liquid metal electrodes energetically favorable. The feasibility of recovering cesium from LiCl-KCl pyroprocessing salt through electrodeposition into liquid metals is eing assessed by identifying potentially effective liquid metals and performing tests to determine the effectiveness of electrodepositing cesium from a LiCl/KCl salt into these liquid metals. Previous studies investigating the electrodeposition of Sr 2+ , and Ba 2+ into zinc, cadmium, bismuth, lead, tin and antimony have shown that alkali and alkaline earth metals can be electrodeposited at liquid metal cathodes (Kim et al., 2018). The removal of Ba 2+ and Sr 2+ was measured to be more efficient than the removal of monovalent cations due to the greater thermochemical driving force for alloying those elements with the liquid metal (Jang et al. 2022). Because the equilibrium potentials are dependent on the interactions of the active metal in the liquid metal, it is likely that the other alkali metals Li + , and K + , will deposit from LiCl/KCl salt with the Cs + . Therefore, application of this method to recover active metals from pyroprocessing salt will benefit from the use of a liquid metal and set of operating conditions that sufficiently increase the reduction potential of cesium to remove cesium from the waste salt with an acceptable amount of co-deposited lithium and potassium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of sidewall boundary layer removal effects on two different chord airfoil models in the Langley 0.3-meter Transonic Cryogenic Tunnel

An investigation was carried out on two CAST 10-2 airfoil models with chords of 3 in. and 6 in. To evaluate the extent of sidewall influence on airfoil tests at transonic Mach numbers. The tests were conducted in the Langley 0.3-m Transonic Cryogenic Tunnel two-dimensional test section equipped with an upstream sidewall boundary layer removal system which reduces the boundary layer displacement thickness to about 1 percent of model halfspan from an initial 2 percent without boundary layer removal. Test results have shown the changes in the location of the shock on the upper surface of the airfoil to be about the same for both models with and without sidewall boundary layer removal. Even though large differences were noted in the high lift characteristics of the two models, the sidewall boundary layer removal had little effect on the differences. These tests also served to validate the boundary layer removal technique and the associated Mach number correction required with upstream boundary layer removal.

Murthy, A. V.↗

Microlith Based Sorber for Removal of Environmental Contaminants

The development of energy efficient, lightweight sorption systems for removal of environmental contaminants in space flight applications is an area of continuing interest to NASA. The current CO2 removal system on the International Space Station employs two pellet bed canisters of 5A molecular sieve that alternate between regeneration and sorption. A separate disposable charcoal bed removes trace contaminants. An alternative technology has been demonstrated using a sorption bed consisting of metal meshes coated with a sorbent, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI); thesemeshes have the potential for direct electrical heating for this application. This allows the bed to be regenerable via resistive heating and offers the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. The capability of removing both CO2 and trace contaminants within the same bed has also been demonstrated. Thus, the need for a separate trace contaminant unit is eliminated resulting in an opportunity for significant weight savings. Unlike the charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration. This paper describes the design and performance of a prototype sorber device for simultaneous CO2 and trace contarninant removal and its attendant weight and energy savings.

Roychoudhury, S.↗

Resistively-Heated Microlith-based Adsorber for Carbon Dioxide and Trace Contaminant Removal

An integrated sorber-based Trace Contaminant Control System (TCCS) and Carbon Dioxide Removal Assembly (CDRA) prototype was designed, fabricated and tested. It corresponds to a 7-person load. Performance over several adsorption/regeneration cycles was examined. Vacuum regenerations at effective time/temperature conditions, and estimated power requirements were experimentally verified for the combined CO2/trace contaminant removal prototype. The current paper details the design and performance of this prototype during initial testing at CO2 and trace contaminant concentrations in the existing CDRA, downstream of the drier. Additional long-term performance characterization is planned at NASA. Potential system design options permitting associated weight, volume savings and logistic benefits, especially as relevant for long-duration space flight, are reviewed. The technology consisted of a sorption bed with sorbent- coated metal meshes, trademarked and patented as Microlith by Precision Combustion, Inc. (PCI). By contrast the current CO2 removal system on the International Space Station employs pellet beds. Preliminary bench scale performance data (without direct resistive heating) for simultaneous CO2 and trace contaminant removal was reviewed in SAE 2004-01-2442. In the prototype, the meshes were directly electrically heated for rapid response and accurate temperature control. This allowed regeneration via resistive heating with the potential for shorter regeneration times, reduced power requirement, and net energy savings vs. conventional systems. A novel flow arrangement, for removing both CO2 and trace contaminants within the same bed, was demonstrated. Thus, the need for a separate trace contaminant unit was eliminated resulting in an opportunity for significant weight savings. Unlike the current disposable charcoal bed, zeolites for trace contaminant removal are amenable to periodic regeneration.

Roychoudhury, S.↗

Engineering Challenges for Active Debris Removal

Recent modeling studies on the instability of the debris population in the low Earth orbit (LEO) region and the collision between Iridium 33 and Cosmos 2251 have underlined the need for active debris removal. A 2009 analysis by the NASA Orbital Debris Program Office shows that, in order to maintain the LEO debris population at a constant level for the next 200 years, an active debris removal of about five objects per year is needed. The targets identified for removal are those with the highest mass and collision probability products in the environment. Many of these objects are spent upper stages with masses ranging from 1 to more than 8 metric tons, residing in several altitude regions and concentrated in about 10 inclination bands. To remove five of those objects on a yearly basis, in a cost-effective manner, represents many challenges in engineering, technology development, and operations. This paper outlines a conceptual end-to-end debris removal operation, including launch, precision tracking, rendezvous, stabilization (of the tumbling targets), capture, and deorbit of the targets; and highlights major challenges associated with the operations. Pros and cons of several proposed removal techniques are also evaluated.

Liou, Jer-Chyi↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently three different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS miniature grab sample containers (GSCs) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the current miniature GSCs and Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

Steven W Beck↗

Quantitation of Trace Water in ISS Atmosphere Samples Recovered from CO2-Removal Systems

As crewed spaceflight continues to push the limits of exploration, instruments and hardware used to maintain and monitor crew and vehicle health, must become more integrated, reliable, and efficient. By combining a carbon dioxide (CO2) removal system with a resource recovery system like a Sabatier or Bosch reactor, the waste gas from the removal system can be converted into valuable resources that help reduce reliance on ground resupply. Due to the high-pressure nature of the Sabatier and Bosch reactions, the vent gas from most CO2 removal systems will need to be compressed before it can be processed. In order to prevent condensation in the compressor of the recovery system, it is critical to ensure that the vent stream from the CO2 removal system does not contain an excess of water. There are currently two different CO2 removal systems that are being developed as candidates for exploration missions. Each of these systems will be evaluated as a technology demonstration on ISS, and vent gas samples will be collected in Summa sampling canisters fitted with Entech valves for ground analysis. Due to the need to measure low levels of water in these samples, it was not possible to use the current ISS mini-grab sample containers (m-GSC) to collect these samples. The Summa containers, which were used to collect archive samples during Shuttle missions, have a different surface treatment that makes it possible to measure the low levels of water in samples collected in these containers. This paper will provide some background on the CO2 removal systems being evaluated for exploration missions as well as results from ground-based testing of the Summa canisters. Details on the development of the analytical method and the plan for preparing the canisters that will be used for in-flight sampling are also discussed.

William M. King↗

ORNL Soils Remediation and Slabs Removal The Bridge from D&D to Redevelopment

The landscape of the Oak Ridge National Laboratory (ORNL) has dramatically changed over the past 2 years with demolition of aging facilities in the Central Campus. Removal of these infrastructure legacies was possible due to an influx of DOE-Environmental Management funding through the American Recovery and Reinvestment Act of 2009 (ARRA). Facility D&D traditionally removes everything down to the building slab, and the Soils and Sediments Program is responsible for slabs, below-grade footers, abandoned waste utilities, and soils contaminated above certain risk levels that must be removed before the site can be considered for redevelopment. , DOE-EM has used a combination of base and ARRA funding to facilitate the clean-up process in ORNL s 2000 Area. Demolition of 13 buildings in the area was funded by the ARRA. Characterization of the remaining slabs, underground pipelines and soils was funded by DOE-EM base funding. Additional ARRA funding was provided for the removal of the slabs, pipelines and contaminated soils. Removal work is in progress and consists of removing and disposing of approximately 10,000 cubic yards (CY) of concrete, 2,500 CY of debris, and 500 CY of contaminated soil. The completion of this work will allow the site to be available for redevelopment and site reuse efforts at ORNL.

Conger, M Malinda↗

Removal and Decommissioning of Disused Gamma Irradiator in Minsk, Belarus

Under the scope of The Department of Energy’s Office of Radiological Security (ORS) Program the Belarusian company, “Isotope Technologies” (IT), in concert with assistance of “Radii” (a company based in Moscow, Russia) dismantled a disused gamma irradiator RKhM-γ-20. This project required innovation, flexibility, and prior experience. The team successfully removed the radioactive sources from the site and moved them to the local radioactive waste facility Ekores. The gamma unit had been installed at the Minsk, Belarus Research Institute of Physical Organic Chemistry in 1971. This research center is a part of the National Academy of Sciences of Belarus. There were 48 highly radioactive Cobalt 60 sources inside the unit. During the dismantling process it was discovered that the source retaining drum was broken. Therefore, the removal proved to be much more complicated than originally envisioned. IT and Radii were unable to remove a number of sources from the drum by means of standard removal equipment and finally needed to remove the entire unit itself along with the remaining sources. The problem was further complicated by a very short timeframe allowed for work implementation. This was because the unit was located near an elementary school requiring the team to complete the project prior to the end of summer school holidays. Moreover, the unit itself was not easily accessible. The project team developed a technical solution and accomplished the removal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of Tritium from the Gaseous Effluents Produced by the Recovery of Zirconium from Used Fuel Cladding

U.S. regulations will require the removal of tritium ({sup 3}H) from gaseous effluents associated with nuclear fuel reprocessing and recycling. One process that may generate {sup 3}H-containing gaseous effluents is the recovery of zirconium from used fuel cladding. A chlorination process developed by Collins et al. is designed to convert the zirconium present in Zircaloy{sup R} cladding to recoverable ZrCl{sub 4}. The greatest economic benefit from including zirconium recycle as part of a larger used nuclear fuel (UNF) recycle effort would be a decrease in the disposal cost of used fuel cladding. Used fuel cladding is considered high-level waste (HLW). As zirconium is the second largest element by mass (25%) contained in most UNF assemblies (with uranium being the largest), recovery of the zirconium could result in a substantial decrease in the amount of HLW intended for geologic disposition. The reclaimed ZrCl{sub 4} product, if sufficiently free from radioactive impurities, could then be disposed of as low-level waste or reused in nuclear applications. The chlorination process uses chlorine gas (Cl{sub 2}) and an inert carrier such as argon (Ar) to convert the zirconium present in cladding to ZrCl{sub 4}. ZrCl{sub 4} is more volatile than other components in the cladding, causing evaporation of a relatively pure gaseous ZrCl{sub 4} stream. The product ZrCl{sub 4} is recovered as a solid salt by condensation when cooled to less than about 300 deg. C. A fraction of the {sup 3}H (0-96%) produced in nuclear fuel during irradiation is found in zirconium-based cladding, possibly as zirconium hydride (the wide range is a remnant of various researchers' analyses of cladding of various irradiations and cooling times). Heating the cladding to high temperatures, such as would be done during the chlorination process, will release the {sup 3}H. At the temperatures of the zirconium recycle process, the {sup 3}H is likely to react with excess Cl{sub 2} to produce tritiated HCl ({sup 3}HCl), although this could be avoided if the cladding and fuel were treated to remove {sup 3}H prior to chlorination. A previous analysis showed that the concentration of {sup 3}HCl in the off-gas of the zirconium recycle process will be in the range of parts per billion to a few parts per million. Should {sup 3}H mitigation be required for the zirconium recycle process, it will be completed through the abatement of {sup 3}HCl from this off-gas stream. The intent of the testing described in this summary was to conduct proof-of-principle demonstrations for two {sup 3}HCl removal methods. The zirconium recycle off-gas stream differs from many industrial HCl-containing streams in that the concentration of HCl requiring removal is extremely low. Demonstrations of HCl removal at ppm concentrations were not found in the literature, making the proof-of-principle approach attractive as a way to identify the most promising method for continued development. An important consideration throughout these experiments was that current research efforts on the zirconium recycle process are conducted in a hot cell and any {sup 3}HCl removal methods should be easily deployed in a hot-cell environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The simultaneous removal of technetium and iodine from Hanford tank waste

The simultaneous removal of radionuclides technetium-99 and iodine-129 from an actual decontaminated Hanford tank waste sample (a mixture of decontaminated waste from tanks 241-AP-105 and 241-AP-107) was demonstrated for the first time in this work. A series of commercially available ion exchange resins were evaluated in batch contact tests in the tank waste, and all showed removal of both Tc and I. The highest Tc removal was observed for Purolite A530e while the highest iodine removal was observed for ResinTech SIR-110-MP. Batch tests in simulated tank waste with these two resins showed that the SIR-110-HP-MP had consistently higher K d for both pertechnetate and iodide and much higher K d than previous works on Tc removal from Hanford waste. As such, the SIR-110-MP was evaluated in a dual -column (lead/lag) test processing 5.2L of the tank waste mixture showing 60% breakthrough of Tc on the lead column and no significant breakthrough on the lag after 625 bed volumes (BV, 6 mL size) while significant iodine breakthrough (>50%) occurred after 28 BV. The limited iodine uptake was attributed to the column conditions generating mass transfer limitations. A fraction of the Tc and I was not captured by the resin (<10%) in either the batch tests or column tests. The iodine fraction was identified to be an iodide, likely organo-iodide. The fraction of the Tc was identified as a non-pertechnetate species, which is the first time non-pertechnetate has been identified in AP-105 and AP-107 tanks, although the exact species is still unknown.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Removal of water from a shallow bath under laser pulse irradiation

An experimental investigation was made of water removal from a shallow bath under the action of a CO{sub 2}-laser radiation pulse focused to a spot of size substantially smaller than the bath length. We showed that the specific expenditure of energy is determined by the intensity of laser radiation at the water surface for different values of the focal spot area and pulse duration. The removal dynamics was studied by single-frame photography technique. It was determined that the water is removed layerwise only from the walls of the cavern, which expands in the horizontal direction upon cessation of the radiation pulse. Two-dimensional numerical simulations were made of the water removal, and a mechanism was proposed to explain the experimentally observed removal pattern. (interaction of laser radiation with matter)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Burning magnesium in carbon dioxide for highly effective phosphate removal

Magnesium oxide was found to have high-phosphate-affinity as an effective component to enhance the phosphate removal ability of common adsorbent materials. However, the currently prepared MgO-based hybrid adsorbents by conventional methods still suffer from the limited low loading of MgO and inferior removal performances, much far away from practical application. In this study, an ingenious carbon coated MgO nanocomposite is designed by directly burning magnesium in CO 2 , a well-known textbook reaction. X-ray diffraction analysis, scanning electron microscope and aberration-corrected high-resolution transmission electron microscope demonstrate the sample is well prepared. Consequently, the high content of nanosized MgO combined with defect-rich carbon layer brings unprecedented phosphate removal capacity of 1135.0 mg/g, removal rate of 99% and benign compatibility with coexisting anions and solution pH. Furthermore, the removal mechanism is also investigated in detail by characterizing the sample before and after adsorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Removal of T-Fasteners 2 Days After Gastrostomy is Feasible

T-fastener gastropexy is widely performed as part of gastrostomy insertion. The current literature recommends removal of T-fasteners at 2 weeks. We present a series of patients in whom T-fasteners were removed at 2 days with no major complications. We removed T-fasteners in 109 patients (male-to-female ratio 59:50, age range 18 to 88 years, mean age 62 years) at 2 days after gastrostomy insertion. Indications for gastrostomy included amytrophic lateral sclerosis, cerebrovascular accidents, head and neck carcinoma, multiple sclerosis, and others, including brain tumours and chronic inflammatory demyelinating polyneuropathy. No peritubal leaks or other major complications were seen in the study population. In the study group, 15 minor complications were recorded (14%), including localised infection and pain, both of which resolved on removal of T-fasteners. We conclude that it is feasible and safe to remove T-fasteners at 2 days.

62 RADIOLOGY AND NUCLEAR MEDICINE↗