Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Dalitz plot analyses of J / ψ → π + π - π 0 , J / ψ → K + K - π 0 , and J / ψ → K s 0 K ± π ∓ produced via e + e - annihilation with initial-state radiation

Here, we study the processes e + e - → γ ISR J/ψ , where J/ψ → π + π - π 0 , J/ψ → K + K - π 0 , and J / ψ → K$0\atop{S}$ K ± π ∓ using a data sample of 519 fb -1 recorded with the BABAR detector operating at the SLAC PEP-II asymmetric-energy e + e - collider at center-of-mass energies at and near the Υ (nS) (n = 2 , 3 , 4) resonances. We measure the ratio of branching fractions R 1 = $B(J/ψ →K^+K^- π^0)\atop{B(J/ψ →π^+π^- π^0)}$ and R 2 = $B(J/ψ →K^0_SK^±π^∓)\atop{B(J/ψ →π^+π^- π^0)}$. We perform Dalitz plot analyses of the three J/ψ decay modes and measure fractions for resonances contributing to the decays. We also analyze the J/ψ → $π^+π^- π^0$ decay using the Veneziano model. We observe structures compatible with the presence of ρ (1450) in all three J/ψ decay modes and measure the relative branching fraction: R (p(1450)) = $Bp(1450)→K^+K^-)\atop{B(p(1450)→π^+π^-)}$ +0.307 ± 0.084 (stat) ± 0.082 (sys).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of the Association of Directors of Radiation Oncology Programs (ADROP) Survey of Radiation Oncology Residency Program Directors

Purpose: To survey the radiation oncology residency program directors on the topics of departmental and institutional support systems, residency program structure, Accreditation Council for Graduate Medical Education (ACGME) requirements, and challenges as program director. Methods: A survey was developed and distributed by the leadership of the Association of Directors of Radiation Oncology Programs to all radiation oncology program directors. Summary statistics, medians, and ranges were collated from responses. Results: Radiation oncology program directors had implemented all current required aspects of the ACGME Outcome Project into their training curriculum. Didactic curricula were similar across programs nationally, but research requirements and resources varied widely. Program directors responded that implementation of the ACGME Outcome Project and the external review process were among their greatest challenges. Protected time was the top priority for program directors. Conclusions: The Association of Directors of Radiation Oncology Programs recommends that all radiation oncology program directors have protected time and an administrative stipend to support their important administrative and educational role. Departments and institutions should provide adequate and equitable resources to the program directors and residents to meet increasingly demanding training program requirements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MLN8054, A Small Molecule Inhibitor of Aurora Kinase A, Sensitizes Androgen-Resistant Prostate Cancer to Radiation;Aurora kinase A; MLN8054; Prostate cancer; Radiation

Purpose: To determine whether MLN8054, an Aurora kinase A (Aurora-A) inhibitor causes radiosensitization in androgen-insensitive prostate cancer cells in vitro and in vivo. Methods and Materials: In vitro studies consisted of culturing PC3 and DU145 prostate cancer cells and then immunoblotting Aurora A and phospho-Aurora A after radiation and/or nocodazole with MLN8054. Phases of the cell cycle were measured with flow cytometry. PC3 and DU145 cell lines were measured for survival after treatment with MLN8054 and radiation. Immunofluorescence measured {gamma}-H2AX in the PC3 and DU145 cells after treatment. In vivo studies looked at growth delay of PC3 tumor cells in athymic nude mice. PC3 cells grew for 6 to 8 days in mice treated with radiation, MLN8054, or combined for 7 more days. Tumors were resected and fixed on paraffin and stained for von Willebrand factor, Ki67, and caspase-3. Results: In vitro inhibition of Aurora-A by MLN8054 sensitized prostate cancer cells, as determined by dose enhancement ratios in clonogenic assays. These effects were associated with sustained DNA double-strand breaks, as evidenced by increased immunofluorescence for {gamma}-H2AX and significant G2/M accumulation and polyploidy. In vivo, the addition of MLN8054 (30 mg/kg/day) to radiation in mouse prostate cancer xenografts (PC3 cells) significantly increased tumor growth delay and apoptosis (caspase-3 staining), with reduction in cell proliferation (Ki67 staining) and vascular density (von Willebrand factor staining). Conclusion: MLN8054, a novel small molecule Aurora-A inhibitor showed radiation sensitization in androgen-insensitive prostate cancer in vitro and in vivo. This warrants the clinical development of MLN8054 with radiation for prostate cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

American Society for Radiation Oncology (ASTRO) 2012 Workforce Study: The Radiation Oncologists' and Residents' Perspectives

Purpose: The American Society for Radiation Oncology (ASTRO) conducted the 2012 Radiation Oncology Workforce Survey to obtain an up-to-date picture of the workforce, assess its needs and concerns, and identify quality and safety improvement opportunities. The results pertaining to radiation oncologists (ROs) and residents (RORs) are presented here. Methods: The ASTRO Workforce Subcommittee, in collaboration with allied radiation oncology professional societies, conducted a survey study in early 2012. An online survey questionnaire was sent to all segments of the radiation oncology workforce. Respondents who were actively working were included in the analysis. This manuscript describes the data for ROs and RORs. Results: A total of 3618 ROs and 568 RORs were surveyed. The response rate for both groups was 29%, with 1047 RO and 165 ROR responses. Among ROs, the 2 most common racial groups were white (80%) and Asian (15%), and the male-to-female ratio was 2.85 (74% male). The median age of ROs was 51. ROs averaged 253.4 new patient consults in a year and 22.9 on-treatment patients. More than 86% of ROs reported being satisfied or very satisfied overall with their career. Close to half of ROs reported having burnout feelings. There was a trend toward more frequent burnout feelings with increasing numbers of new patient consults. ROs' top concerns were related to documentation, reimbursement, and patients' health insurance coverage. Ninety-five percent of ROs felt confident when implementing new technology. Fifty-one percent of ROs thought that the supply of ROs was balanced with demand, and 33% perceived an oversupply. Conclusions: This study provides a current snapshot of the 2012 radiation oncology physician workforce. There was a predominance of whites and men. Job satisfaction level was high. However a substantial fraction of ROs reported burnout feelings. Perceptions about supply and demand balance were mixed. ROs top concerns reflect areas of attention for the healthcare sector as a whole.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Current Status and Recommendations for the Future of Research, Teaching, and Testing in the Biological Sciences of Radiation Oncology: Report of the American Society for Radiation Oncology Cancer Biology/Radiation Biology Task Force, Executive Summary

In early 2011, a dialogue was initiated within the Board of Directors (BOD) of the American Society for Radiation Oncology (ASTRO) regarding the future of the basic sciences of the specialty, primarily focused on the current state and potential future direction of basic research within radiation oncology. After consideration of the complexity of the issues involved and the precise nature of the undertaking, in August 2011, the BOD empanelled a Cancer Biology/Radiation Biology Task Force (TF). The TF was charged with developing an accurate snapshot of the current state of basic (preclinical) research in radiation oncology from the perspective of relevance to the modern clinical practice of radiation oncology as well as the education of our trainees and attending physicians in the biological sciences. The TF was further charged with making suggestions as to critical areas of biological basic research investigation that might be most likely to maintain and build further the scientific foundation and vitality of radiation oncology as an independent and vibrant medical specialty. It was not within the scope of service of the TF to consider the quality of ongoing research efforts within the broader radiation oncology space, to presume to consider their future potential, or to discourage in any way the investigators committed to areas of interest other than those targeted. The TF charge specifically precluded consideration of research issues related to technology, physics, or clinical investigations. This document represents an Executive Summary of the Task Force report.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low Interrater Reliability in Grading of Rectal Bleeding Using National Cancer Institute Common Toxicity Criteria and Radiation Therapy Oncology Group Toxicity Scales: A Survey of Radiation Oncologists

Purpose: To measure concordance among genitourinary radiation oncologists in using the National Cancer Institute Common Toxicity Criteria (NCI CTC) and Radiation Therapy Oncology Group (RTOG) grading scales to grade rectal bleeding. Methods and Materials: From June 2013 to January 2014, a Web-based survey was sent to 250 American and Canadian academic radiation oncologists who treat prostate cancer. Participants were provided 4 case vignettes in which patients received radiation therapy and developed rectal bleeding and were asked for management plans and to rate the bleeding according to NCI CTC v.4 and RTOG late toxicity grading (scales provided). In 2 cases, participants were also asked whether they would send the patient for colonoscopy. A multilevel, random intercept modeling approach was used to assess sources of variation (case, respondent) in toxicity grading to calculate the intraclass correlation coefficient (ICC). Agreement on a dichotomous grading scale (low grades 1-2 vs high grades 3-4) was also assessed, using the κ statistic for multiple respondents. Results: Seventy-two radiation oncologists (28%) completed the survey. Forty-seven (65%) reported having either written or been principal investigator on a study using these scales. Agreement between respondents was moderate (ICC 0.52, 95% confidence interval [CI] 0.47-0.58) when using NCI CTC and fair using the RTOG scale (ICC 0.28, 95% CI 0.20-0.40). Respondents who chose an invasive management were more likely to select a higher toxicity grade (P<.0001). Using the dichotomous scale, we observed moderate agreement (κ = 0.42, 95% CI 0.40-0.44) with the NCI CTC scale, but only slight agreement with the RTOG scale (κ = 0.19, 95% CI 0.17-0.21). Conclusion: Low interrater reliability was observed among radiation oncologists grading rectal bleeding using 2 common scales. Clearer definitions of late rectal bleeding toxicity should be constructed to reduce this variability and avoid ambiguity in both reporting and interpretation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoscale Engineering Of Radiation Tolerant Silicon Carbide

Radiation tolerance is determined by how effectively the microstructure can remove point defects produced by irradiation. Engineered nanocrystalline SiC with a high-density of stacking faults (SFs) has significantly enhanced recombination of interstitials and vacancies, leading to selfhealing of irradiation-induced defects. While single crystal SiC readily undergoes an irradiationinduced crystalline to amorphous transformation at room temperature, the nano-engineered SiC with a high-density of SFs exhibits more than an order of magnitude increase in radiation resistance. Molecular dynamics simulations of collision cascades show that the nano-layered SFs lead to enhanced mobility of interstitial Si atoms. The remarkable radiation resistance in the nano-engineered SiC is attributed to the high-density of SFs within nano-sized grain structures that significantly enhance point defect annihilation.

Environmental Molecular Sciences Laboratory↗

DarkLight radiation backgrounds

We report measurements of photon and neutron radiation levels observed while transmitting a 0.43 MW electron beam through millimeter-sized apertures and during beam-on, but accelerating gradient RF-on, operation. These measurements were conducted at the Free-Electron Laser (FEL) facility of the Jefferson National Accelerator Laboratory (JLab) using a 100 MeV electron beam from an energy-recovery linear accelerator. The beam was directed successively through 6 mm, 4 mm, and 2 mm diameter apertures of length 127 mm in aluminum at a maximum current of 4.3 mA (430 kW beam power). This study was conducted to characterize radiation levels for experiments that need to operate in this environment, such as the proposed DarkLight Experiment. We find that sustained transmission of a 430 kW CW beam through a 2 mm aperture is feasible with manageable beam-related backgrounds. We also find that during beam-off, RF-on operation, field emission inside the niobium cavities of the accelerator cryomodules is the primary source of ambient radiation.

43 PARTICLE ACCELERATORS↗

Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U

A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terrestrial radiative cooling: Using the cold universe as a renewable and sustainable energy source

Photonic materials designed at wavelength scales have enabled a range of emerging energy technologies, from solid-state lighting to efficient photovoltaics that have transformed global energy landscapes. Daytime passive radiative cooling materials shed heat from the ground to the cold universe by taking advantage of the terrestrial thermal radiation that is as large as the renewable solar energy. Newly developed photonic materials permit subambient cooling under direct sunshine, and their applications are expanding rapidly enabled by scalable manufacturing. We review here the recent advancement of daytime subambient radiative cooling materials, which allow energy-efficient cooling and are paving the way toward technologies that harvest the coldness from the universe as a new renewable energy source.

Science & Technology - Other Topics↗