Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Solar radiation calibration facility.

A recently completed calibration facility for the NASA Mississippi Test Site is described. It combines the spectrum of water cooled long arc xenon radiation sources with the integration sphere concept covered by a special barium sulfate diffusely reflecting paint. The sphere is six feet in diameter and completely encompasses the four xenon sources (2.5 kW each) and the five pyranometers under calibration. The sources are contained within the base of the central pedestal and allow the radiation to be emitted into the lower hemisphere. Only through diffuse reflection and multiple scattering is the radiation finally incident upon the test zone, which is in the equatorial plane of the sphere on the top of the pedestal. The sphere is temperature controlled.

Hershey, T. L.↗

Optical Radiation from Shock-Compressed Materials

Recent observations of shock-induced radiation from oxides, silicates, and metals of geophysical interest constrain the shock-compressed temperature of these materials. The relationships between the temperature inferred from the observed radiation and the temperature of the shock-compressed film or foil and/or window were investigated. Changes of the temperature field in each target component away from that of their respective shock-compressed states occur because of: shock-impedance mismatch between target components; thermal mismatch between target components; surface roughness at target interfaces; and conduction within and between target components. In particular, conduction may affect the temperature of the film/foil window interface on the time scale of the experiments, and so control the intensity and history of the dominant thermal radiation sources in the target. This type of model was used to interpret the radiation emitted by a variety of shock-compressed materials and interfaces.

Svendsen, Robert F., Jr.↗

Oscillator strengths for Fe II transitions at 224.918 and 226.008 nanometers

We report accurate experimental absorption oscillator strengths (f-values) for transitions out of the ground level of Fe II to the Z(sup 4)D(sup 0 sub 7/2) and z(sup 4)F(sup 0 sub 9/2) levels at 224.918 and 226.008 nm (air wavelengths) to be 0.00182(14) and 0.00244(19), respectively. The number in parenthesis is the uncertainty in the last digits. These two lines are important for studying Fe abundances and grain depletions in the interstellar medium. These f-values are determined by combining emission branching fractions with radiative lifetimes. Branching fractions are measured using classical spectroradiometry on an optically thin source. Radiative lifetimes are from the literature.

Bergeson, S. D.↗

Fluence Uniformity Measurements in an Electron Accelerator Used for Irradiation of Extended Area Solar Cells and Electronic Circuits for Space Applications

It is common to have liquid crystal displays and electronic circuit boards with area sizes of the order of 20x20 sq cm on board of satellites and space vehicles. Usually irradiating them at different fluence values assesses the radiation damage in these types of devices. As a result, there is a need for a radiation source with large spatial fluence uniformity for the study of the damage by radiation from space in those devices. Kent State University s Program on Electron Beam Technology has access to an electron accelerator used for both research and industrial applications. The electron accelerator produces electrons with energies in the interval from 1 to 5 MeV and a maximum beam power of 150 kW. At such high power levels, the electron beam is continuously scanned back and forth in one dimension in order to provide uniform irradiation and to prevent damage to the sample. This allows for the uniform irradiation of samples with an area of up to 1.32 sq m. This accelerator has been used in the past for the study of radiation damage in solar cells (1). However in order to irradiate extended area solar cells there was a need to measure the uniformity of the irradiation zone in terms of fluence. In this paper the methodology to measure the fluence uniformity on a sample handling system (linear motion system), used for the irradiation of research samples, along the irradiation zone of the above-mentioned facility is described and the results presented. We also illustrate the use of the electron accelerator for the irradiation of large area solar cells (of the order of 156 sq cm) and include in this paper the electrical characterization of these types of solar cells irradiated with 5 MeV electrons to a total fluence of 2.6 x 10(exp 15) e/sq cm.

Uribe, Roberto M.↗

A hybrid-kinetic simulation tool for non-thermal warm x-ray z-pinch sources, with gas-puff and wire array exemplars

Increasing the fluence of z-pinch x-ray radiation sources above ∼ 10 keV has been a long-standing goal for scientists at Sandia National Laboratories’ Z Machine. Optimizing sources for non-thermal “cold Kα” emission in higher atomic-number materials appears to be a promising path to increase warm x-ray yield. However, this emission is generated by supra-thermal electrons, which are not treated in the magnetohydrodynamic (MHD) codes that are typically used in z-pinch source development. MHD codes do not allow for charge separation or space-charge-generated electric fields, and constrain particle kinematics to Maxwellian distributions. The kinetic codes which do accommodate discrete, non-thermal energy distributions are computationally prohibitive when modeling plasmas near solid density and when modeling/tracking higher ionization states. Thus, modeling non-thermal z-pinch sources requires a new simulation tool. In this report, we present a new hybrid modeling capability that uses the fast features of MHD-type particles to the greatest extent possible, then transitions to the slower but more complete kinetic particle treatment to correctly capture the particle energy spectra that generate non-thermal emission. This capability is founded on the fully-relativistic particle-in-cell code Chicago, which already includes fluid particle treatments. The governing equations and hybrid methodology presented here are applied in simulations of an argon gas-puff and a molybdenum wire-array to provide preliminary code validation. The argon simulation is compared to measured implosion times and yields from Jones et al., Phys. Plasmas 22, 020706 (2015). The simulated x-ray yield is within 25% of measurements and the implosion times agree within a few percent. The molybdenum wire array simulation captures the implosion timing reported in Hansen et al., Phys. Plasmas 21, 031202 (2014), but work is needed to verify the available EOS table. These exemplar simulations represents the type of non-thermal sources that will be developed using the hybrid code capability going forward.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detectors and diagnostics for multiprobe radiography using high-energy short-pulse lasers

Multiprobe radiography requires the following diagnostic capabilities at minimum: radiographic source diagnostics, spectroscopy, imaging, and tomography diagnostics. Depending on the repetition rate of the radiation sources, the diagnostics may be a single-shot diagnostic, such as photographic (radiochromic and X-ray films for high energy photons) films, or a multiple-shot diagnostic for repetitive source operations, such as a high-speed framing camera. Due to the drastically different detector physics of electrons, photons at different energies (keV to 10s of MeV in the radiography context), heavy ions such as protons, alphas, and neutrons, see, for example, Ref. [1, 2] for an overview, different types or configurations of detectors and constructions may be required for multiprobe radiography applications. Some of the common detector metricsinclude, independent of the particle/photon species, sensitivities or efficiency, energy resolution, spatial or temporal resolutions and others. Some unique detection scenarios arise in a multiprobe radiography setting, for example, crosstalk mitigation and particle identification (ID) when X-ray and higher energy photons, relativistic electrons, neutrons, other hadrons, and heavy particles coexist at the detector location.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multispectral variable magnification glancing incidence x ray telescope

A multispectral, variable magnification, glancing incidence, x-ray telescope capable of broadband, high resolution imaging of solar and stellar x-ray and extreme ultraviolet radiation sources is discussed. The telescope includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable mirror carriers, each providing a different magnification, are positioned behind the primary focus at an inclination to the optical axis. Each carrier has a series of ellipsoidal mirrors, and each mirror has a concave surface covered with a multilayer (layered synthetic microstructure) coating to reflect a different desired wavelength. The mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A detector such as an x-ray sensitive photographic film is positioned at the second respective focus of each mirror so that each mirror may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected mirror on the second carrier to receive the radiation.

Hoover, Richard B.↗

Hubble Space Telescope images of the Seyfert galaxies NGC 5929 and MCG 8-11-11

We present the initial results of a program to obtain high resolution images of Seyfert galaxies with the Planetary Camera aboard the Hubble Space Telescope (HST). In this paper we discuss the images of the type 2 Seyfert NGC 5929 and the type 1.5 Seyfert MCG 8-11-11 (= UGC 3374). The images were obtained in the emission lines of (O III) lambda lambda 4959 and 5007 A and H alpha + (N II) lambda lambda 6548 and 6583 A and their adjacent continua. The high-excitation gas in the narrow line region (NLR) of NGC 5929 is resolved into individual clouds in the central 1 sec .5. Although the (O III) emission is clearly not spherically symmetric with respect to the nucleus, it does not define a distinct 'bicone' morphology, as observed by the HST in a few other Seyfert galaxies. We find no direct evidence for the reddening and/or obscuration effects characteristic of a dusty torus, which, in the context of 'unified models', is expected to obscure the active galactic nucleus (AGN) in type 2 Seyfert galaxies. The correspondence between the emission line gas and the radio morphology suggests that the structure of the NLR in NGC 5929 is governed by matter ejected from the AGN. A comparison of the recombination rate of hydrogen in the brightest emission line cloud with an upper limit on the ionizing luminosity emitted toward Earth provides no evidence that the central ionizing source radiates anisotropically. The images of MCG 8-11-11 show only an unresolved nuclear source. No emission line gas associated with the extended radio source is detected. We estimate upper limits on the intensity of extended line emission in this galaxy and examine their significance.

Bower, Gary A.↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Real-time mixed reality display of dual particle radiation detector data

Radiation source localization and characterization are challenging tasks that currently require complex analyses for interpretation. Mixed reality (MR) technologies are at the verge of wide scale adoption and can assist in the visualization of complex data. Herein, we demonstrate real-time visualization of gamma ray and neutron radiation detector data in MR using the Microsoft HoloLens 2 smart glasses, significantly reducing user interpretation burden. Radiation imaging systems typically use double-scatter events of gamma rays or fast neutrons to reconstruct the incidence directional information, thus enabling source localization. The calculated images and estimated ’hot spots’ are then often displayed in 2D angular space projections on screens. By combining a state-of-the-art dual particle imaging system with HoloLens 2, we propose to display the data directly to the user via the head-mounted MR smart glasses, presenting the directional information as an overlay to the user’s 3D visual experience. We describe an open source implementation using efficient data transfer, image calculation, and 3D engine. We thereby demonstrate for the first time a real-time user experience to display fast neutron or gamma ray images from various radioactive sources set around the detector. We also introduce an alternative source search mode for situations of low event rates using a neural network and simulation based training data to provide a fast estimation of the source’s angular direction. Using MR for radiation detection provides a more intuitive perception of radioactivity and can be applied in routine radiation monitoring, education & training, emergency scenarios, or inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Medium-Scale Methanol Pool Fire Model Validation

In this work, medium scale (30 cm diameter) methanol pool fires were simulated using the latest fire modeling suite implemented in Sierra/Fuego, a low Mach number multiphysics reacting flow code. The sensitivity of model outputs to various model parameters was studied with the objective of providing model validation. This work also assesses model performance relative to other recently published large eddy simulations (LES) of the same validation case. Two pool surface boundary conditions were simulated. The first was a prescribed fuel mass flux and the second used an algorithm to predict mass flux based on a mass and energy balance at the fuel surface. Gray gas radiation model parameters (absorption coefficients and gas radiation sources) were varied to assess radiant heat losses to the surroundings and pool surface. The radiation model was calibrated by comparing the simulated radiant fraction of the plume to experimental data. The effects of mesh resolution were also quantified starting with a grid resolution representative of engineering type fire calculations and then uniformly refining that mesh in the plume region. Simulation data were compared to experimental data collected at the University of Waterloo and the National Institute of Standards and Technology (NIST). Validation data included plume temperature, radial and axial velocities, velocity temperature turbulent correlations, velocity velocity turbulent correlations, radiant and convective heat fluxes to the pool surface, and plume radiant fraction. Additional analyses were performed in the pool boundary layer to assess simulated flame anchoring and the effect on convective heat fluxes. This work assesses the capability of the latest Fuego physics and chemistry model suite and provides additional insight into pool fire modeling for nonluminous, non-sooting flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determination of bone mineral mass in vivo

Radiographic equipment incorporates two radiation sources, generating high-energy and low-energy beams. Recording equipment measures amount of radiation that has penetrated limb. Data are fed into computer that determines mass of the examined bone.

Cameron, J. R.↗

Operation Aurorozone: An experiment in sun/weather

Operation Aurorozone was a highly coordinated sequence of 33 rocket flights launched from Poker Flat, Alaska, in September 1976. The effects of aurorally produced X-rays on stratospheric neutral and electrical parameters was studied. The sun/weather coupling between upper and lower regions of the atmosphere is thought to be related to these middle atmospheric parameters. The results show a consistent depletion of ozone above 1 mb during three independent auroral events, with magnitudes in excess of those expected from the measured energy radiation sources. Simultaneously, enhanced conductivity changes were observed to occur in accord with the measured ionizing radiations.

Goldberg, R. A.↗

Propellant combustion response to oscillatory radiant heat flux

An introductory progress report is given on a research project to use the microwave Doppler velocimeter technique to measure the combustion response to an oscillating thermal radiation source (laser). The objective is to relate the measured burning rate response to the thermal radiation to an equivalent oscillation in pressure using existing thermal combustion theory. The test system is described, and the results of an initial test series on the composite propellant A-13 are presented.

Strand, L. D.↗

An improved patch for radiative coolers

A unique structure for constructing the emissive patch of a spaceborne radiative cooler is shown. The structure has very high emissivity for all angles up to a designed-in maximum angle and near zero emissivity for greater angles. The structure also allows the use of high emissivity, nonconducting paints while fully complying with the NASA Electrostatic Discharge Susceptibility requirements for spacecraft. To accomplish these tasks, two previous disadvantages of prior art methods are addressed; eliminating background thermal radiation sources and problems concerning the high emissivity paints used in association with the black body radiator. A reflector consisting of an array of parabolic concentrators is separated from a black body element by an electrically conductive spacer. The concentrators serve to limit the field of view while the conductive spacer eliminates the need to use a conductive paint on the emissive element.

Bly, Vincent T.↗