Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Shock Layer Radiation Measurements and Analysis for Mars Entry

NASA's In-Space Propulsion program is supporting the development of shock radiation transport models for aerocapture missions to Mars. A comprehensive test series in the NASA Antes Electric Arc Shock Tube facility at a representative flight condition was recently completed. The facility optical instrumentation enabled spectral measurements of shocked gas radiation from the vacuum ultraviolet to the near infrared. The instrumentation captured the nonequilibrium post-shock excitation and relaxation dynamics of dispersed spectral features. A description of the shock tube facility, optical instrumentation, and examples of the test data are presented. Comparisons of measured spectra with model predictions are also made.

Bose, Deepak↗

Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

54 ENVIRONMENTAL SCIENCES↗

Shock Tube Radiation Measurement in Expanding Air Flow

The EAST facility has been widely used in the past to provide experimental data aiming to validate radiative heating models. However, all the past studies involved measurements of compressing flows. In order to study recombining flows, an expansion cone has been installed in the EAST facility. Four spectrometers are mounted at different axial positions of the cone to measure the evolution of the radiation during expansion. Quantitative data from optical emission spectroscopy will be used to get the densities of radiative species. These data are intended to be compared with simulations in order to improve the current models used by the entry community.

Augustin Tibere-Inglesse↗

Shock Tube Radiation Measurement in Expanding Air Flows

The EAST facility has been widely used in the past to provide experimental data aiming to validate radiative heating models. However, all the past studies involved measurements of compressing flows. In order to study recombining flows, an expansion cone has been installed in the EAST facility. Four spectrometers are mounted at different axial positions of the cone to measure the evolution of the radiation during expansion. Quantitative data from optical emission spectroscopy will be used to get the densities of radiative species. These data are intended to be compared with simulations in order to improve the current models used by the entry community.

Augustin Tibère-Inglesse↗

Determination of solar proton fluxes and energies at high solar latitudes by UV radiation measurements

The latitudinal variation of the solar proton flux and energy causes a density increase at high solar latitudes of the neutral gas penetrating the heliosphere. Measurements of the neutral density by UV resonance radiation observations from interplanetary spacecraft thus permit deductions on the dependence of the solar proton flux on heliographic latitude. Using both the results of Mariner 10 measurements and of other off-ecliptic solar wind observations, the values of the solar proton fluxes and energies at polar heliographic latitudes are determined for several cases of interest. The Mariner 10 analysis, together with IPS results, indicate a significant decrease of the solar proton flux at polar latitudes.

Witt, N.↗

The influence of laser clipped by the laser entrance hole on hohlraum radiation measurement on Shenguang-III prototype

Measuring the x-ray flux exiting the target's laser entrance hole (LEH) is the most common diagnostic that quantifies the x-ray intensity inside the laser-driven hohlraum. However, this signal accounts for only a small portion of the incident laser power and thus is likely to be affected by unwanted x-ray background from non-target area, leading to an overestimation of the hohlraum drive. Unwanted emission might be produced when the laser light is clipped by the LEH (LEH clipping) because of a lack of clearance for laser spot, or with a laser spot comprising of discrete structure, or even with a poor pointing accuracy. Its influence on the hohlraum radiation diagnostic is investigated on Shenguang-III prototype laser facility with the typical 1 ns square pulse. The experiment employed three types of targets to excite the unwanted x-ray background from LEH clipping, unconverted light, and both effects, respectively. This work gives an absolute evaluation of x-ray produced by the LEH clipping, which is measured by flat-response x-ray detectors (FXRD) at multiple view angles. The result indicates that there is little variation in measured emission to various view angles, because the unwanted x-rays are mainly generated at the side face of the LEH lip when laser is obliquely incident. Therefore, the LEH clipping brings more overestimation in hohlraum radiation measurement at larger view angle since the hohlraum LEH as an emitting source viewed by FXRD is decreased as the view angle increases. In our condition, the LEH clipping contributes 2%–3.5% overestimation to the hohlraum flux measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation measurements from polar and geosynchronous satellites

Towards understanding the role of radiation in the dynamics of climate, a climatology of radiation budget data has been compiled and several aspects of the problem are under study: (1) minimum albedoes; (2) diurnal variation in cloudiness and the radiation budget; (3) the partitioning of energy loss to space between land, ice, ocean and atmosphere; and (4) the effects of clouds on the radiation budget. Oceanic precipitation using Nimbus 5 microwave data, and a new study of mesoscale applications of satellite infrared temperature and moisture soundings are also described.

Vonderhaar, T. H.↗

A Strategy to Assess Aerosol Direct Radiative Forcing of Climate Using Satellite Radiation Measurements

Atmospheric aerosols have a complex internal chemical composition and optical properties. Therefore it is difficult to model their impact on redistribution and absorption of solar radiation, and the consequent impact on atmospheric dynamics and climate. The use in climate models of isolated aerosol parameters retrieved from satellite data (e.g. optical thickness) may result in inconsistent calculations, if the model assumptions differ from these of the satellite retrieval schemes. Here we suggest a strategy to assess the direct impact of aerosol on the radiation budget at the top and bottom of the atmosphere using satellite and ground based measurements of the spectral solar radiation scattered by the aerosol. This method ensures consistent use of the satellite data and increases its accuracy. For Kaufman and Tanre: Strategy for aerosol direct forcing anthropogenic aerosol in the fine mode (e.g. biomass burning smoke and urban pollution) consistent use of satellite derived optical thickness can yield the aerosol impact on the spectral solar flux with accuracy an order of magnitude better than the optical thickness itself. For example, a simulated monthly average smoke optical thickness of 0.5 at 0.55 microns (forcing of 40-50 W/sq m) derived with an error of 20%, while the forcing can be measured directly with an error of only 0-2 W/sq m. Another example, the effect of large dust particles on reflection of solar flux can be derived three times better than retrievals of optical thickness. Since aerosol impacts not only the top of the atmosphere but also the surface irradiation, a combination of satellite and ground based measurements of the spectral flux, can be the most direct mechanism to evaluate the aerosol effect on climate and assimilate it in climate models. The strategy is applied to measurements from SCAR-B and the Tarfox experiments. In SCAR-B aircraft spectral data are used to derive the 24 hour radiative forcing of smoke at the top of the atmosphere of (Delta)F(sub 24hr)/(Delta)tau = - 25 +/- 5 W/sq m. Ground based data give forcing at the surface of (Delta)F(sub 24hr)/(Delta)taur = -80 +/- 5 W/sq m. In TARFOX a mixture of maritime and regional pollution aerosol resulted in a varied forcing at the top of the atmosphere, (Delta)F(sub 24hr)/(Delta)tau, between -26 W/sq 2 and -50 W/sq m depending on mixture of coarse and accumulation modes, for Angstrom exponents of 1.0 and 0.2 respectively.

Kaufman, Yoram J.↗

Space Station - Infrastructure for radiation measurements in low earth orbit

The general configuration, development schedule, and capabilities of the NASA International Space Station are reviewed, with an emphasis on the possibilities for long-term measurements of high-energy cosmic and secondary radiation from the main Station spacecraft, coorbiting or polar-orbit platforms, or Station-supported GEO satellites. Also outlined are the organizational structure and the application procedures to be followed by potential users of the Station facilities. Diagrams and drawings are provided.

Meredith, B. D.↗

Polar solar wind and interstellar wind properties from interplanetary Lyman-alpha radiation measurements

The analysis of Mariner 10 observations of Lyman-alpha resonance radiation shows an increase of interplanetary neutral hydrogen densities above the solar poles. This increase is caused by a latitudinal variation of the solar wind velocity and/or flux. Using both the Mariner 10 results and other solar wind observations, the values of the solar wind flux and velocity with latitude are determined for several cases of interest. The latitudinal variation of interplanetary hydrogen gas, arising from the solar wind latitudinal variation, is shown to be most pronounced in the inner solar system. From this result it is shown that spacecraft Lyman-alpha observations are more sensitive to the latitudinal anisotropy for a spacecraft location in the inner solar system near the downwind axis.

Witt, N.↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Future radiation measurements in low Earth orbit

The first Long Duration Exposure Facility (LDEF) mission has demonstrated the value of the LDEF concept for deep surveys of the space radiation environment. The kinds of measurements that could be done on a second LDEF mission are discussed. Ideas are discussed for experiments which: (1) capitalize on the discoveries from LDEF 1; (2) take advantage of LDEF's unique capabilities; and (3) extend the investigations begun on LDEF 1. These ideas have been gleaned from investigators on LDEF 1 and others interested in the space radiation environment. They include new approaches to the investigation of Be-7 that was discovered on LDEF 1, concepts to obtain further information on the ionic charge state of cosmic rays and other energetic particles in space and other ideas to extend the investigations begun on LDEF 1.

Adams, James H., Jr.↗

SU-F-J-202: Secondary Radiation Measurements for Charged Particle Therapy Monitoring: Fragmentation of Therapeutic He, C and O Ion Beams Impinging On a PMMA Target

Purpose: In Charged Particle Therapy (CPT), besides protons, there has been recently a growing interest in 4He, 12C and 16O beams. The secondary radiation produced in the interaction of those beams with a patient could be potentially used for on-line monitoring of range uncertainties in order to fully exploit the advantages of those light ions resulting from increased Radio Biological Effectiveness, reduced multiple scattering and Oxygen Enhancement Ratio. The study and precise characterization of secondary radiation (beta+, prompt gamma, charged fragments) is the cornerstone of any R&D activity aiming for online monitoring development and purpose of the analysis presented here. Methods: We present the measurements of the secondary radiation generated by He, C and O beams impinging on a beam stopping PMMA target. The data has been collected at the Heidelberg Ionbeam Therapy center (HIT), where several millions of collisions were recorded at different energies, relevant for therapeutical applications. Results: The experimental setup, as well as the analysis strategies will be reviewed. The detected particle fluxes as a function of the primary beam energy and the emission angle with respect to the beam direction will be presented and compared to the results of other available measurements. In addition, the energy spectra and emission shapes of charged secondary particles will be shown and discussed in the context of the primary beam range monitoring technique that is being developed by the ARPG collaboration, within the INSIDE project funded by the Italian research ministry. The implications for dose monitoring applications will be discussed, in the context of the current (or planned) state-of- the-art detector solutions. Conclusion: The characterization of the radiation produced by 12C, 4He and 16O beams fully supports the feasibility of on-line range monitoring in the clinical practice of CPT by means of secondary particles detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗