Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

MDSplus yesterday, today and tomorrow

MDSplus is a data acquisition and analysis system used worldwide predominantly in the fusion research community. Development began 31 years ago by a collaboration of software developers who were charged with providing a data acquisition system for three new fusion experiments under construction: CMOD at MIT, ZTH at LANL and RFX at Padova, Italy. The design of MDSplus combined the functionality of MDS (MIT/Model Data System developed at MIT for the Alcator and Tara fusion experiments) with new features suggested by the developers from the other laboratories. The development of MDSplus used a RAD (rapid application development) approach before RAD became a mainstream methodology. MDSplus was implemented and ready for the initial operation of CMOD in 1991. Since that time, many other fusion facilities started using MDSplus for data acquisition and/or for exporting their data to other sites. Today MDSplus is still used around the world for fusion energy research, space exploration and other fields of science and technology. Work on MDSplus continues to enhance its capabilities, support more platforms, and improve its reliability. It is anticipated that MDSplus will continue to provide valuable tools for the fusion energy research community. In conclusion, this paper describes some of the history of the MDSplus software, the work that is currently underway, and the plans to enable MDSplus to continue to be available and supported long into the future.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental verification of a method to create a variable energy neutron beam from a monoenergetic, isotropic source using neutron elastic scatter and time of flight

An experiment was performed to determine the neutron energy of near-monoergetic deuterium–deu-terium (D–D) neutrons that elastically scatter in a hydrogenous target. The experiment used two liquid scintillators to perform time of flight (TOF) measurements to determine neutron energy, with the start detector also serving as the scatter target. The stop detector was placed 1.0 m away and at scatter angles of π/6, π/4, and π/3 rad, and 1.5 m at a scatter angle of π/4 rad. When discrete 1 ns increments were implemented, the TOF peaks had estimated errors between 21.2 and 3.6% relative to their expected locations. Full widths at half-maximum (FWHM) ranged between 9.6 and 20.9 ns, or approximately 0.56–0.66 MeV. Monte Carlo simulations were also conducted that approximated the experimental setup and had both D–D and deuterium–tritium (DT) neutrons. The simulated results had errors between -17.2 and 0.0% relative to their expected TOF peaks when 1 ns increments were applied. The largest D–D and D–T FWHMs were 26.7 and 13.7 ns, or approximately 0.85 and 4.98 MeV, respectively. These values, however, can be reduced through manipulation of the dimensions of the system components. Lastly, the results encourage further study of the neutron elastic scatter TOF system with particular interest in application to active neutron interrogation to search for conventional explosives.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling of the electron cyclotron emission burst from a laboratory tokamak plasma with loss-cone maser instability

The maser instability associated with the loss-cone distribution has been widely invoked to explain the radio bursts observed in the astrophysical plasma environment, such as aurora and corona. In the laboratory plasma of a tokamak, events reminiscent of these radio bursts have also been frequently observed as an electron cyclotron emission (ECE) burst in the microwave range (~2f ce near the last closed flux surface) during transient magnetohydrodynamic events. These bursts have a short duration of ~10 μs and display a radiation spectrum corresponding to a radiation temperature T e,rad of over 30 keV while the edge thermal electron temperature T e is only in the range of 1 keV. Suprathermal electrons can be generated through magnetic reconnection, and a loss-cone distribution can be generated through open stochastic field lines in the magnetic mirror of the near-edge region of a tokamak plasma. Radiation modelling shows that a sharp distribution gradient ∂f/∂v ⊥ > 0 at the loss-cone boundary can cause a negative absorption of ECE radiation through the maser instability. The negative absorption then amplifies the radiation so that the microwave intensity is significantly stronger than the thermal value. The significant T e,rad from the simulations suggests the potential role of the loss-cone maser instability in generating the ECE burst in a tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Compact nanomechanical plasmonic phase modulators [Ultracompact nano-mechanical plasmonic phase modulators]

Highly confined optical energy in plasmonic devices is advancing miniaturization in photonics. However, for mode sizes approaching ≈10 nm, the energy increasingly shifts into the metal, raising losses and hindering active phase modulation. Here, we propose a nanoelectromechanical phase-modulation principle exploiting the extraordinarily strong dependence of the phase velocity of metal–insulator–metal gap plasmons on dynamically variable gap size. We experimentally demonstrate a 23-μm-long non-resonant modulator having a 1.5π rad range, with 1.7 dB excess loss at 780 nm. Analysis shows that by simultaneously decreasing the gap, length and width, an ultracompact-footprint π rad phase modulator can be realized. This is achieved without incurring the extra loss expected for plasmons confined in a decreasing gap, because the increasing phase-modulation strength from a narrowing gap offsets rising propagation losses. Here, such small, high-density electrically controllable components may find applications in optical switch fabrics and reconfigurable plasmonic optics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong magnetic exchange coupling in Ln 2 metallocenes attained by the trans -coordination of a tetrazinyl radical ligand

A combination of high-performing lanthanide metallocenes and tetrazine-based radical ligands leads to a new series of radical-bridged dinuclear lanthanide metallocenes; [(Cp* 2 Ln III ) 2 (bpytz˙ - )][BPh 4 ] (where Ln = Gd (1), Tb (2), Dy (3) and Y (4); Cp* = pentamethylcyclopentadienyl; bpytz = 3,6-bis(3,5-dimethyl-pyrazolyl)-1,2,4,5-tetrazine). The formation of the radical species is achieved via a controlled, stepwise synthesis and verified in all complexes by X-ray crystallography and SQUID magnetometry, as well as EPR spectroscopy of 4. Through the judicious choice of the Cp* ancillary ligands and by taking advantage of the steric effects imposed by their bulkiness, we were able to promote the trans coordination mode of the bpytz˙ - radical anion that enables stronger magnetic exchange coupling compared to the cis fashion. This yields a J Gd–rad = -14.0 cm -1 in 1, which is the strongest exchange coupling observed in organic monoanionic radical-bridged lanthanide metallocene systems. The strong Ln-rad exchange coupling was further confirmed by high-frequency EPR (HF-EPR) spectroscopy and broken-symmetry (BS) density functional theory (DFT) calculations. Further, this combined with the highly anisotropic nature of Tb III and Dy III ions in 2 and 3, respectively, leads to strong SMM behavior and slow relaxation of the magnetization at zero fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

eROSITA Final Equatorial-Depth Survey (eFEDS) eFEDS X-ray view of WERGS radio galaxies selected by the Subaru/HSC and VLA/FIRST survey

We constructed the eROSITA X-ray catalog of radio galaxies discovered by the WERGS survey, made by cross-matching the wide area Subaru/Hyper Suprime-Cam (HSC) optical survey and VLA/FIRST 1.4 GHz radio survey. We report finding 393 eROSITA detected radio galaxies in the 0.5-2 keV band in the eFEDS field covering 140 deg 2 . Thanks to the wide and medium depth eFEDS X-ray survey down to f 0.5 - 2 keV = 6.5 × 10 -15 erg s -1 cm -2 , the sample contains the rare and most X-ray luminous radio galaxies above the knee of the X-ray luminosity function, spanning 44 < log(L 0.5-2 keV (abs,corr) /erg s -1 ) < 46.5 at 1 < z < 4. The sample also contains the sources around and below the knee for the sources 41 < log(L 0.5-2 keV (abs,corr) /erg s -1 ) < 45 at z < 1. Based on the X-ray properties obtained by the spectral fitting, 37 sources show obscured active galactic nucleus (AGN) signatures with log(N H /cm -2 ) > 22. These obscured and radio AGN reside in 0.4 < z < 3.2, indicating that they are obscured counterparts of the radio-loud quasar, which were missed in the previous optical quasar surveys. By combining radio and X-ray luminosities, we also investigated the jet production efficiency η jet = η rad P jet /L AGN,bol by utilizing the jet power of P jet . We find that there are 14 sources with extremely high jet production efficiency at η jet ≈ 1. This high η jet value might be a result of the decreased radiation efficiency of η rad < 0.1, due to the low accretion rate for those sources, and/or of the boosting due to the decline of L AGN,bol by a factor of 10-100 by keeping P jet constant in the previous Myr, indicating the experience of the AGN feedback. Finally, inferring the BH masses from the stellar mass, we find that X-ray luminous sources show the excess of the radio emission with respect to the value estimated from the fundamental plane. This radio emission excess cannot be explained by the Doppler boosting alone, and therefore the disk–jet connection of X-ray luminous eFEDS-WERGS is fundamentally different from the conventional fundamental plane which mainly covers the low-accretion regime.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical design of the short pulse x-ray imaging and microscopy time-angle correlated diffraction beamline at the Advanced Photon Source

The short pulse x-ray imaging and microscopy beamline is one of the two x-ray beamlines that will take full advantage of the short pulse x-ray source in the Advanced Photon Source (APS) upgrade. A horizontally diffracting double crystal monochromator which includes a sagittally focusing second crystal will collect most of the photons generated when the chirped electron beam traverses the undulator. A Kirkpatrick-Baez mirror system after the monochromator will deliver to the sample a beam which has an approximately linear correlation between time and vertical beam angle. The correlation at the sample position has a slope of 0.052 ps/{mu}rad extending over an angular range of 800 {mu}rad for a cavity deflection voltage of 2 MV. The expected time resolution of the whole system is 2.6 ps. The total flux expected at the sample position at 10 keV with a 0.9 eV energy resolution is 5.7 Multiplication-Sign 10{sup 12} photons/s at a spot having horizontal and vertical full width at half maximum of 33 {mu}m horizontal by 14 {mu}m vertical. This new beamline will enable novel time-dispersed diffraction experiments on small samples using the full repetition rate of the APS.

43 PARTICLE ACCELERATORS↗

Shot-noise-limited optical Faraday polarimetry with enhanced laser noise cancelling

We present a shot-noise-limited measurement of optical Faraday rotations with sub-ten-nanoradian angular sensitivity. This extremely high sensitivity is achieved by using electronic laser noise cancelling and phase sensitive detection. Specially, an electronic laser noise canceller with a common mode rejection ratio of over 100 dB was designed and built for enhanced laser noise cancelling. By measuring the Faraday rotation of ambient air, we demonstrate an angular sensitivity of up to 9.0×10{sup −9} rad/√(Hz), which is limited only by the shot-noise of the photocurrent of the detector. To date, this is the highest angular sensitivity ever reported for Faraday polarimeters in the absence of cavity enhancement. The measured Verdet constant of ambient air, 1.93(3)×10{sup −9}rad/(G cm) at 633 nm wavelength, agrees extremely well with the earlier experiments using high finesse optical cavities. Further, we demonstrate the applications of this sensitive technique in materials science by measuring the Faraday effect of an ultrathin iron film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A high precision, compact electromechanical ground rotation sensor

We present a mechanical rotation sensor consisting of a balance pivoting on a tungsten carbide knife edge. These sensors are important for precision seismic isolation systems, as employed in land-based gravitational wave interferometers and for the new field of rotational seismology. The position sensor used is an air-core linear variable differential transformer with a demonstrated noise floor of 1 × 10{sup −11}m/√( Hz ). We describe the instrument construction and demonstrate low noise operation with a noise floor upper bound of 5.7 × 10{sup −9} rad /√( Hz ) at 10 mHz and 6.4 × 10{sup −10} rad /√( Hz ) at 0.1 Hz. The performance of the knife edge hinge is compatible with a behaviorur free of noise from dislocation self-organized criticality.

42 ENGINEERING↗

Design of a fully-fiber multi-chord interferometer and a new phase-shift demodulation method for field-reversed configuration

A 633 nm laser interferometer has been designed based on a novel concept, which, without the acousto-optic modulator or the demodulator circuit, adopts the fibers to connect all elements except photodetectors and oscilloscope in this system to make it more compact, portable, and efficient. The noteworthy feature is to mathematically compare the two divided interference signals, which have the same phase-shift caused by the electron density but possess the different initial phase and low angular frequencies. It is possible to read the plasma density directly on the oscilloscope by our original mathematic demodulation method without a camera. Based on the Abel inversion algorithm, the radial electron density profiles versus time can be obtained by using the multi-chord system. The designed measurable phase shift ranges from 0 to 2π rad corresponding to the maximum line integral of electron density less than 3.5 × 10{sup 17} cm{sup −2}, and the phase accuracy is about 0.017 rad corresponding to the line integral of electron density accuracy of 1 × 10{sup 15} cm{sup −2}. After the construction of eight-chord interferometer, it will provide the detailed time resolved information of the spatial distribution of the electron density in the field-reversed configuration (FRC) plasma target produced by the “Yingguang-1” programmed-discharge device, which is being constructed in the Key Laboratory of Pulsed Power, China Academy of Engineering Physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact micro-wave synthesizer for transportable cold-atom interferometers

We present the realization of a compact micro-wave frequency synthesizer for an atom interferometer based on stimulated Raman transitions, applied to transportable inertial sensing. Our set-up is intended to address the hyperfine transitions of {sup 87}Rb at 6.8 GHz. The prototype is evaluated both in the time and the frequency domain by comparison with state-of-the-art frequency references developed at Laboratoire national de métrologie et d'essais−Systémes de référence temps espace (LNE-SYRTE). In free-running mode, it features a residual phase noise level of −65 dB rad{sup 2} Hz{sup −1} at 10 Hz offset frequency and a white phase noise level in the order of −120 dB rad{sup 2} Hz{sup −1} for Fourier frequencies above 10 kHz. The phase noise effect on the sensitivity of the atomic interferometer is evaluated for diverse values of cycling time, interrogation time, and Raman pulse duration. To our knowledge, the resulting contribution is well below the sensitivity of any demonstrated cold atom inertial sensors based on stimulated Raman transitions. The drastic improvement in terms of size, simplicity, and power consumption paves the way towards field and mobile operations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low phase noise microwave frequency synthesis for a high-performance cesium vapor cell atomic clock

We report the development, absolute phase noise, and residual phase noise characterization of a 9.192 GHz microwave frequency synthesis chain devoted to be used as a local oscillator in a high-performance cesium vapor cell atomic clock based on coherent population trapping (CPT). It is based on frequency multiplication of an ultra-low phase noise 100 MHz oven-controlled quartz crystal oscillator using a nonlinear transmission line-based chain. Absolute phase noise performances of the 9.192 GHz output signal are measured to be −42, −100, −117 dB rad{sup 2}/Hz and −129 dB rad{sup 2}/Hz at 1 Hz, 100 Hz, 1 kHz, and 10 kHz offset frequencies, respectively. Compared to current results obtained in a state-of-the-art CPT-based frequency standard developed at LNE-SYRTE, this represents an improvement of 8 dB and 10 dB at f = 166 Hz and f = 10 kHz, respectively. With such performances, the expected Dick effect contribution to the atomic clock short term frequency stability is reported at a level of 6.2 × 10{sup −14} at 1 s integration time, that is a factor 3 higher than the atomic clock shot noise limit. Main limitations are pointed out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined reactor neutron beam and {sup 60}Co γ-ray radiation effects on CMOS APS image sensors

The combined reactor neutron beam and {sup 60}Co γ-ray radiation effects on complementary metal-oxide semiconductor (CMOS) active pixel sensors (APS) have been discussed and some new experimental phenomena are presented. The samples are manufactured in the standard 0.35-μm CMOS technology. Two samples were first exposed to {sup 60}Co γ-rays up to the total ionizing dose (TID) level of 200 krad(Si) at the dose rates of 50.0 and 0.2 rad(Si)/s, and then exposed to neutron fluence up to 1 × 10{sup 11} n/cm{sup 2} (1-MeV equivalent neutron fluence). One sample was first exposed to neutron fluence up to 1 × 10{sup 11} n/cm{sup 2} (1-MeV equivalent neutron fluence), and then exposed to {sup 60}Co γ-rays up to the TID level of 200 krad(Si) at the dose rate of 0.2 rad(Si)/s. The mean dark signal (K{sub D}), the dark signal non-uniformity (DSNU), and the noise (V{sub N}) versus the total dose and neutron fluence has been investigated. The degradation mechanisms of CMOS APS image sensors have been analyzed, especially for the interaction induced by neutron displacement damage and TID damage.

36 MATERIALS SCIENCE↗

The experimental setup of the Interaction in Crystals for Emission of RADiation collaboration at Mainzer Mikrotron: Design, commissioning, and tests

Silicon/germanium flat/bent crystals are thin devices able to efficiently deflect charged particle GeV-energy beams up to a few hundreds of μrad; moreover, high intensity photons can be efficiently produced in the so-called Multi-Volume Reflection (MVR) and Multiple Volume Reflections in One Crystal (MVROC) conditions. In the last years, the research interest in this field has moved to the dynamic studies of light negative leptons in the low energy range: the possibility to deflect negative particles and to produce high intensity γ sources via the coherent interactions with crystals in the sub-GeV energy range has been proved by the ICE-RAD (Interaction in Crystals for Emission of RADiation) Collaboration at the MAinzer MIkrotron (MAMI, Germany). This paper describes the setup used by the ICE-RAD experiment for the crystals characterization (both in terms of deflection and radiation emission properties): a high precision goniometer is used to align the crystals with the incoming beam, while a silicon based profilometer and an inorganic scintillator reconstruct, respectively, the particle position and the photon spectra after the samples. The crystals manufacturing process and their characterization, the silicon profilometer commissioning at the CERN PS T9 beamline, and the commissioning of the whole setup installed at MAMI are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple-design ultra-low phase noise microwave frequency synthesizers for high-performing Cs and Rb vapor-cell atomic clocks

We report on the development and characterization of novel 4.596 GHz and 6.834 GHz microwave frequency synthesizers devoted to be used as local oscillators in high-performance Cs and Rb vapor-cell atomic clocks. The key element of the synthesizers is a custom module that integrates a high spectral purity 100 MHz oven controlled quartz crystal oscillator frequency-multiplied to 1.6 GHz with minor excess noise. Frequency multiplication, division, and mixing stages are then implemented to generate the exact output atomic resonance frequencies. Absolute phase noise performances of the output 4.596 GHz signal are measured to be −109 and −141 dB rad{sup 2}/Hz at 100 Hz and 10 kHz Fourier frequencies, respectively. The phase noise of the 6.834 GHz signal is −105 and −138 dB rad{sup 2}/Hz at 100 Hz and 10 kHz offset frequencies, respectively. The performances of the synthesis chains contribute to the atomic clock short term fractional frequency stability at a level of 3.1 × 10{sup −14} for the Cs cell clock and 2 × 10{sup −14} for the Rb clock at 1 s averaging time. This value is comparable with the clock shot noise limit. We describe the residual phase noise measurements of key components and stages to identify the main limitations of the synthesis chains. The residual frequency stability of synthesis chains is measured to be at the 10{sup −15} level for 1 s integration time. Relevant advantages of the synthesis design, using only commercially available components, are to combine excellent phase noise performances, simple-architecture, low-cost, and to be easily customized for signal output generation at 4.596 GHz or 6.834 GHz for applications to Cs or Rb vapor-cell frequency standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-overtone bulk acoustic wave resonator-oscillator-based 4.596 GHz frequency source: Application to a coherent population trapping Cs vapor cell atomic clock

This article reports on the design and characterization of a high-overtone bulk acoustic wave resonator (HBAR)-oscillator-based 4.596 GHz frequency source. A 2.298 GHz signal, generated by an oscillator constructed around a thermally controlled two-port aluminum nitride-sapphire HBAR resonator with a Q-factor of 24 000 at 68 °C, is frequency multiplied by 2–4.596 GHz, half of the Cs atom clock frequency. The temperature coefficient of frequency of the HBAR is measured to be −23 ppm/ °C at 2.298 GHz. The measured phase noise of the 4.596 GHz source is −105 dB rad{sup 2}/Hz at 1 kHz offset and −150 dB rad{sup 2}/Hz at 100 kHz offset. The 4.596 GHz output signal is used as a local oscillator in a laboratory-prototype Cs microcell-based coherent population trapping atomic clock. The signal is stabilized onto the atomic transition frequency by tuning finely a voltage-controlled phase shifter implemented in the 2.298 GHz HBAR-oscillator loop, preventing the need for a high-power-consuming direct digital synthesis. The short-term fractional frequency stability of the free-running oscillator is 1.8 × 10{sup −9} at one second integration time. In locked regime, the latter is improved in a preliminary proof-of-concept experiment at the level of 6.6 × 10{sup −11} τ{sup −1/2} up to a few seconds and found to be limited by the signal-to-noise ratio of the detected CPT resonance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗