Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality control.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SIMBAD quality-control

The astronomical database SIMBAD developed at the Centre de donnees astronomiques de Strasbourg presently contains 760,000 objects (stellar and non-stellar). It has the unique characteristic of being structured specifically for astronomical objects. All types of heterogeneous data (bibliographic references, measurements, and sets of identification) are connected with each object. The attributes that define quality of the database include the following. Reliability: cross-identification should not rely upon just exact values object coordinates. It also means that information attached to one simple object should be consistent. The existing data must be controlled in order to start with a reliable base and to cross-identify new data assuring the quality as data grows. Exhaustivity: delays between publication of new informations and their inclusion in the database should be as short as possible. The integrity of the database has to be maintained as data accumulates. Taking the amount of data into consideration and the rate of new data production, it is necessary to use automatic methods. One of the possibilities is to use multivariate data analysis. The factor-space is a n-dimensional relevancy space which is described by the n-axes representing a set of n subject matter headings; the words and phrases can be used to scale the axes and the documents are then a vector average of the terms within them. The application reported herein is based on the NASA-STI bibliographical database. The selected data concern astronomy, astrophysics, and space radiation (102,963 references from 1975 to 1991 included 8070 keywords). The F-space is built from this bibliographical data. By comparing the F-space position obtained from the NASA-STI keywords with the F-space position obtained from the SIMBAD references, the authors will be able to show whether it is possible to retrieve information with a restricted set of words only. If the comparison is valid, this will be a way to enter bibliographic information in the SIMBAD quality control process. Furthermore, it is possible to connect the physical measurements of stars from SIMBAD to literature concerning these stars from the NASA-STI abstracts. The physical properties of stars (e.g. UBV colors) are not randomly distributed. Stars are distributed among different clusters in a physical parameter space. The authors will show that there are some relations between this classification and the literature concerning these objects clusters in a factor space. They will investigate the nature of the relationship between the SIMBAD measurements and the bibliography. These would be new relationships that are not pre-established by an astronomer. In addition, the bibliography could be neutral information that can be used in combination with the measured parameters.

Lesteven, Soizick↗

SU-E-T-43: A Methodology for Quality Control of IMPT Treatment Plan Based On VMAT Plan

Purpose: IMPT plan design is highly dependent on planner’s experiences. VMAT plan design is relatively mature and can even be automated. The quality of IMPT plan designed by in-experienced planner could be inferior to that of VMAT plan designed by experienced planner or automatic planning software. Here we introduce a method for designing IMPT plan based on VMAT plan to ensure the IMPT plan be superior to IMRT/VMAT plan for majority clinical scenario. Methods: To design a new IMPT plan, a VMAT plan is first generated either by experienced planner or by in-house developed automatic planning system. An in-house developed tool is used to generate the dose volume constrains for the IMPT plan as plan template to Eclipse TPS. The beam angles for IMPT plan are selected based on the preferred angles in the VMAT plan. IMPT plan is designed by importing the plan objectives generated from VMAT plan. Majority thoracic IMPT plans are designed using this plan approach in our center. In this work, a thoracic IMPT plan under RTOG 1308 protocol is selected to demonstrate the effectiveness and efficiency of this approach. The dosimetric indices of IMPT are compared with VMAT plan. Results: The PTV D95, lung V20, MLD, mean heart dose, esophagus D1, cord D1 are 70Gy, 31%, 17.8Gy, 25.5Gy, 73Gy, 45Gy for IMPT plan and 65.3Gy, 34%, 21.6Gy, 35Gy, 74Gy, 48Gy for VMAT plan. For majority cases, the high dose region of the normal tissue which is in proximity of PTV is comparable between IMPT and VMAT plan. The low dose region of the IMPT plan is significantly better than VMAT plan. Conclusion: Using the knowledge gained in VMAT plan design can help efficiently and effectively design high quality IMPT plan. The quality of IMPT plan can be controlled to ensure the superiority of IMPT plan compared to VMAT/IMRT plan.

60 APPLIED LIFE SCIENCES↗

Insights and Impacts of Credentials: Energy Auditor, Quality Control Inspector, and Certification Updates

Join this session to learn about recent and upcoming Home Energy Professional credential and resource updates from the National Renewable Laboratory (NREL) in support of the U.S. Department of Energy's Weatherization Assistance Program (WAP). NREL staff will provide an in-depth overview of improvements to the EA and QCI certification schemes. Be prepared to provide feedback and share new ideas in pursuit of continuous improvement within WAP. These certifications are critical to ensuring the highest standards of quality, safety, and efficiency within the Weatherization Assistance Program, helping to elevate the skills of professionals and drive the program's overall success.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surface photovoltage method for the quality control of silicon epitaxial layers on sapphire

The surface photovoltage method is used to study “silicon-on-sapphire” epitaxial layers with a thickness of 0.3–0.6 μm, which are used to fabricate p-channel MOS (metal—oxide-semiconductor) transistors with improved radiation hardness. It is shown that the manner in which the photoconductivity of the epitaxial layer decays after the end of a light pulse generated by a light-emitting diode (wavelength ∼400 nm) strongly depends on the density of structural defects in the bulk of the structure. This enables control over how a “silicon-on-sapphire” structure is formed to provide the manufacturing of MOS structures with optimal operating characteristics.

36 MATERIALS SCIENCE↗

Energy Auditor and Quality Control Inspector Certification Updates

This presentation discusses recent and future Home Energy Professional credential and resource updates at the National Renewable Energy Laboratory in support to the U.S Department of Energy's Weatherization Assistance Program (WAP). It will provide an in-depth overview of planned improvements to the EA and QCI certification schemes.

certification↗

Quality Control in Fast Pyrolysis Bio-Oil Production and Use

This paper will focus on norms and standards for fast pyrolysis bio-oils. It will include the present status and address what still has to be done on bio-oil specifications and relevant test methods. The paper will address industrial needs in commercialization of the fuel oil use of bio-oil, including the registration application to the REACH program and its consequences within the European Union, as well as development of a standard within ASTM. The paper will discuss the most important properties of bio-oil and the variation in these properties among various bio-oils. It will address the issue of quality follow-up in bio-oil production, including the properties to be followed and the laboratory and on-line monitoring methods. The paper will provide a state of the art of fuel oil specifications, test methods, and testing procedures as they are applied to bio-oil. It will review the effort in support of the implementation of an ASTM standard including the methods validation work.

02 PETROLEUM↗

Integrated System of Thermal/Dimensional Analysis for Quality Control of Metallic Melt and Ductile Iron Casting Solidification

The main objective of the present work is to introduce a specific experimental instrument and technique for simultaneously evaluating cooling curves and expansion or contraction of cast metals during solidification. Contraction/expansion analysis illustrates the solidification parameters progression, according to the molten cast iron characteristics, which are dependent on the melting procedure and applied metallurgical treatments, mold media rigidity and thermal behavior [heat transfer parameters]. The first part of the paper summarizes the performance of this two-mold device. Its function is illustrated by representative shrinkage tendency results in ductile cast iron as affected by mold rigidity (green sand and furan resin sand molds) and inoculant type (FeSi-based alloys), published in part previously. The second part of the paper illustrates an application of this equipment adapted for commercial foundry use. It conducts thermal analysis and volume change measurements in a single ceramic cup so that mold media as well as solidification conditions are constants, with cast iron quality as the variable. Experiments compared gray and ductile cast iron solidification patterns. Gray iron castings are characterized by higher undercooling at the beginning and at the end of solidification and lower graphitic expansion. Typically, ductile cast iron exhibits higher graphitic, initial expansion, conducive for shrinkage formation in soft molds.

36 MATERIALS SCIENCE↗

Results of The Excreta Bioassay Quality Control Program For April 1, 2010 Through March 31, 2011

A total of 76 urine samples and 10 spiked fecal samples were submitted during the report period (April 1, 2010 through March 31, 2011) to GEL Laboratories, LLC in South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for 14C, Sr, for 238 Pu, 239 Pu, 241 Am, 243 Am, 235U, 238U, 238U-mass and fecal analyses for 241Am, 238 Pu and 239 Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.1% of the total samples submitted.

61 RADIATION PROTECTION AND DOSIMETRY↗

Loss of protein synthesis quality control in host-restricted organisms

Significance This case study reveals that parasitic and symbiotic lifestyles affect the structure of essential molecular machineries of a living cell. We provide evidence that intracellular parasitism and endosymbiosis cause degeneration of the editing domains in aminoacyl-tRNA synthetases, a defect that is known to cause inaccurate translation of the genetic code. This finding suggests that most intracellular pathogens, including causative agents of human disease, have an unanticipated proteome diversity caused by inaccurate translation of the genetic code. Our finding may change current approaches to the study of proteomes of intracellular parasites, parasite–host interactions, and parasites’ sensitivity to drugs, which cause errors in transcription, translation, and protein folding.

59 BASIC BIOLOGICAL SCIENCES↗

Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning

Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control of concrete at the stage of designing its composition and technology

The results of tests on samples of foam concrete with a hardening accelerator are presented. As the setting and hardening accelerators the following chemical additives were used: Universal-P-2 and Asilin 12. All additives were added into the insulating foam concrete mix of brand D 400 in the amount of 0.5% to 1% of cement weight. By using of additives in foam concrete technology – hardening accelerators Asilin 12 and Universal P2 in the amount of 0.5 % - and 1.0% by weight of cement foam concrete structure formation is accelerated and increases strength by 60%. For the industrial preparation of foam concrete mix technological regulations are worked out, in which it is recommended to use additives – hardening accelerators Asilin 12 in the amount of 0.5% and Universal P2 - 1% of cement weight.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-153: Establish a Comprehensive Patient-Specific Plan QA Database for Instituitional Quality Control Program

Purpose: Since the publication of TG-119, several new treatment techniques requiring new QA devices have been implemented in the clinic. To monitor and analyze our institutional QA performance, we have created a comprehensive QA database using Research Electronic Data Capture (REDCap). The database will also assist us in creating IMRT QA Analysis practice guidelines. Methods: Since Oct. 2013, 336 patient plan QA results were entered into the database. Plan parameters such as plan ID, treatment site, technique, energy, optimization constraints, modulation factor, leaf speed, leaf opening.etc were automatically extracted from the Varian Eclipse database to allow us to refine our evaluation and analysis method. Specific QA device, LINAC-related information, and measurement and analysis results were manually entered by the QA team. IMRT plans were measured using MapCHECK2 while RapidArc plans were measured using ArcCHECK. Distance-To-Agreement 3%/3mm without global maximum normalization was used. Results: The data indicates that different treatment techniques might benefit from a different site-specific action level(AL) depending on the complexity of the plan and optimization parameter used (e.g., breast IMRT QA= 97.8% and pelvis IMRT QA=93.1%). Different QA devices may also benefit from a different AL (MapCHECK2 = 94.1% while ArcCHECK = 83.0%). The relationship between the parameters and passing rate suggests that the complexity of each plan, characterized by leaf travel, leaf opening and modulation factor, affect the passing rate significantly. The database is reviewed regularly, and any abnormal point of the QA result or a trend of lower QA passing rate on a specific LINAC is further investigated. Conclusion: Establishing a comprehensive QA database provides an overview of the quality assurance program. It not only helps in answering the question “what is a reasonable and achievable standard for each institution”, but also saves time in monitoring and investigating the daily machine and QA performance.

07 ISOTOPE AND RADIATION SOURCES↗

Experience with the Quality Control of Radioactive Waste Packages for the German Repository Konrad - 16493

The German repository Konrad for radioactive waste with negligible heat generation is designed to accept 303,000 m{sup 3} of waste packages in total. Based on the Konrad licensing conditions, any treatment and conditioning of radioactive waste should be planned and carried out in accordance with the waste acceptance requirements of the repository Konrad in order to produce waste packages suitable for disposal. The qualification of the waste treatment processes and the resulting products are achieved by interaction of different parties involved. On behalf of the Federal Office for Radiation Protection - the competent German authority for disposal of radioactive waste - TUV NORD EnSys Hannover GmbH and Co. KG acts as one of the independent expert organizations for more than twenty years in the field of qualification of waste treatment campaigns and review of waste packages documentations. The permitted amount of nuclide activity in the radioactive waste packages depends on the characteristics of the radioactive waste products. Projecting a suitable strategy for loading the waste containers contributes to determine in advance, what requirements the radioactive waste products have to fulfill as well as what properties of the waste products need to be verified and documented during conditioning or treatment process. On the basis of various examples, it is being demonstrated how appropriate advance process planning can ensure that radioactive waste packages are generated to comply with the waste acceptance requirements. In consequence, technical measures due to requalification can be avoided even in case of unpredictable difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Snowex 2017 Community Snow Depth Measurements: A Quality-Controlled, Georeferenced Product

Snow depth was one of the core ground measurements required to validate remotely-sensed data collected during SnowEx Year 1, which occurred in Colorado. The use of a single, common protocol was fundamental to produce a community reference dataset of high quality. Most of the nearly 100 Grand Mesa and Senator Beck Basin SnowEx ground crew participants contributed to this crucial dataset during 6-25 February 2017. Snow depths were measured along ~300 m transects, whose locations were determined according to a random-stratified approach using snowfall and tree-density gradients. Two-person teams used snowmobiles, skis, or snowshoes to travel to staked transect locations and to conduct measurements. Depths were measured with a 1-cm incremented probe every 3 meters along transects. In shallow areas of Grand Mesa, depth measurements were also collected with GPS snow-depth probes (a.k.a. MagnaProbes) at ~1-m intervals. During summer 2017, all reference stake positions were surveyed with <10 cm accuracy to improve overall snow depth location accuracy. During the campaign, 193 transects were measured over three weeks at Grand Mesa and 40 were collected over two weeks in Senator Beck Basin, representing more than 27,000 depth values. Each day of the campaign depth measurements were written in waterproof field books and photographed by National Snow and Ice Data Center (NSIDC) participants. The data were later transcribed and prepared for extensive quality assessment and control. Common issues such as protocol errors (e.g., survey in reverse direction), notebook image issues (e.g., halo in the center of digitized picture), and data-entry errors (sloppy writing and transcription errors) were identified and fixed on a point-by-point basis. In addition, we strove to produce a georeferenced product of fine quality, so we calculated and interpolated coordinates for every depth measurement based on surveyed stakes and the number of measurements made per transect. The product has been submitted to NSIDC in csv format. To educate data users, we present the study design and processing steps that have improved the quality and usability of this product. Also, we will address measurement and design uncertainties, which are different in open vs. forest areas.

Brucker, L.↗