Relative Shock Effects in Mixed Powders of Calcite, Gypsum, and Quartz: A Calibration Scheme from Shock Experiments

The shock behavior of calcite and gypsum is important in understanding the Cretaceous/Tertiary event and other terrestrial impacts that contain evaporite sediments in their targets. Most interest focuses on issues of devolatilization to quantify the production of CO2 or SO2 to better understand their role in generating a temporary atmosphere and its effects on climate and biota [e.g., papers in 1,2,3,4]. Devolatilization of carbonate is also important because the dispersion and fragmentation of ejecta is strongly controlled by the expansion of large volumes of gas during the impact process as well [5,6]. Shock recovery experiments for calcite yield seemingly conflicting results: early experimental devolatilization studies [7,8,9] suggested that calcite was substantially outgassed at 30 GPa (> 50%). However, the recent petrographic work of [10,11,12] presented evidence that essentially intact calcite is recovered from 60 GPa experiments. [13] reported results of shock experiments on anhydrite, gypsum, and mixtures of those phases with silica. Their observations indicate little or no devolatilization of anhydrite shocked to 42 GPa and that the fraction of sulfur, by mass, that degassed is approx.10(exp -2) of theoretical prediction. In another (preliminary) report of shock experiments on calcite, anhydrite, and gypsum, [14] observe calcite recrystallization when shock loaded at 61 GPa, only intensive plastic deformation in anhydrite shock loaded at 63 GPa, and gypsum converted to anhydrite when shock loaded at 56 GPa. [15] shock loaded anhydrite and quartz to a peak pressure of 60 GPa. All of the quartz grains were trans-formed to glass and the platy anhydrite grains were completely pseudomorphed by small crystallized anhydrite grains. However, no evidence of interaction between the two phases could be observed and they suggest that recrystallization of anhydrite grains is the result of a solid state transformation. [16] reanalyzed the calcite and anhydrite shock wave experiments of [17] using improved equations of state of porous materials and vaporized products. They determined the pressures for incipient and complete vaporization to be 32.5 and 122 GPa for anhydrite and 17.8 and 54.1 GPa for calcite, respectively, a factor of 2 to 3 lower than reported earlier by [17].

Bell, Mary S.↗

Quartz Detector for the SuperHMS Spectrometer at Hall-C Jefferson Lab

We have developed and constructed a quartz hodoscope to be part of the trigger system for the Super High Momentum Spectrometer (SHMS). The SHMS spectrometer will play a central role in carrying out the 12-GeVphysics program at Hall-C Jefferson Lab. The hodoscope consists of twenty one fused silica bars. Each bar is 125-cm long, 5.5-cm wide, and 2.5-cm thick. It is viewed by a UV-sensitive PMT on each end. The quartz hodoscope task is to provide a clean detection of charged particles, a high level of background suppression, and an accurate tracking efficiency determination. We present results of tests leading to the construction of the hodoscope, as well performance test results of the completed detectors such as detection efficiency and position resolution.

Ahmidouch, Abdellah↗

Evidence for residual elastic strain in deformed natural quartz

Residual elastic strain in naturally deformed, quartz-containing rocks can be measured quantitatively in a petrographic thin section with high spatial resolution using Laue microdiffraction with white synchrotron x-rays. The measurements with a resolution of one micrometer allow the quantitative determination of the deviatoric strain tensor as a function of position within the crystal investigated. The observed equivalent strain values of 800-1200 microstrains represent a lower bound of the actual preserved residual strain in the rock, since the stress component perpendicular to the cut sample surface plane is released. The measured equivalent strain translates into an equivalent stress in the order of {approx} 50 MPa.

58 GEOSCIENCES↗

Examining polymer‐protein biophysical interactions with small‐angle x‐ray scattering and quartz crystal microbalance with dissipation

Abstract Polymer‐protein hybrids can be deployed to improve protein solubility and stability in denaturing environments. While previous work used robotics and active machine learning to inform new designs, further biophysical information is required to ascertain structure–function behavior. Here, we show the value of tandem small‐angle x‐ray scattering (SAXS) and quartz crystal microbalance with dissipation (QCMD) experiments to reveal detailed polymer‐protein interactions with horseradish peroxidase (HRP) as a test case. Of particular interest was the process of polymer‐protein complex formation under thermal stress whereby SAXS monitors formation in solution while QCMD follows these dynamics at an interface. The radius of gyration ( R g ) of the protein as measured by SAXS does not change significantly in the presence of polymer under denaturing conditions, but thickness and dissipation changes were observed in QCMD data. SAXS data with and without thermal stress were utilized to create bead models of the potential complexes and denatured enzyme, and each model fit provided insight into the degree of interactions. Additionally, QCMD data demonstrated that HRP deforms by spreading upon surface adsorption at low concentration as shown by longer adsorption times and smaller frequency shifts. In contrast, thermally stressed and highly inactive HRP had faster adsorption kinetics. The combination of SAXS and QCMD serves as a framework for biophysical characterization of interactions between proteins and polymers which could be useful in designing polymer‐protein hybrids.

60 APPLIED LIFE SCIENCES↗

A practical guide to quartz crystal microbalance with dissipation monitoring of thin polymer films

Quartz crystal microbalance with dissipation (QCM-D) monitoring is a powerful tool used to sensitively examine the real-time responses of polymer films to external responses. For example, the technique is commonly used to monitor film growth, material adsorption, thin film swelling, and ion exchange. With its rapidly expanding use, this review is intended to introduce new users to the basic principles of QCM-D, along with practical challenges and remedies specific to polymer thin films. For both new and experienced users, specific case studies are highlighted including layer-by-layer assembly, electrochemical QCM-D, swelling, sensing, and biological application. Finally, the review recommends future directions for research and areas of growth.

36 MATERIALS SCIENCE↗

Accurate and Sensitive Analytical Strategy for the Determination of Antimony: Hydrogen Assisted T-Shaped Slotted Quartz Tube-Atom Trap-Flame Atomic Absorption Spectrometry

Antimony is known to have some adverse health effects on human health. Flame atomic absorption spectrometry (FAAS) is a widely used instrumental for the determination of antimony and other metals. However, it lacks the sensitivity to determine these metals at trace levels. This study was aimed at overcoming this setback by using hydrogen assisted T-shaped slotted quartz tube technique to preconcentrate and determine antimony by FAAS. All the system parameters were optimized to enhance the detection power of the system. Under the optimum experimental conditions, the limits of detection and quantification were found to be 0.75 and 2.49 µg L{sup −1}, respectively with R{sup 2} value of 0.9999. Accuracy of the developed method was validated by experimental results agreeing to the certified value of a standard reference material. Recovery studies were also carried out to determine the method’s applicability to tap and mineral water samples, and the results obtained were appreciable.

54 ENVIRONMENTAL SCIENCES↗

Quartz Piezoelectric Resonance Gas Analyzers

Design and metrological characteristics of quartz piezoelectric resonance gas analyzers are considered. It is shown that these devices allow solving various tasks at automation of technological processes in the chemical, oil and gas and related industries (in particular, the task of ensuring ecological and sanitary-hygienic safety).

02 PETROLEUM↗

A 3D-Printed Microresonator Based on the Quartz-Enhanced Photoacoustic Spectroscopy Sensor for Methane Detection

A 3D-printed microresonator based on a quartz tuning fork has been developed. The sensor performance is evaluated by detection of methane with a fiber-coupled distributed feedback diode laser. In combination with wavelength modulation spectroscopy, a minimum detectable concentration of 15.6 ppb by volume is achieved at atmospheric pressure with an 8-mW average optical excitation power and a lock-in amplifier time constant of 1 s, which corresponds to a 1σ normalized noise equivalent absorption coefficient of 5·10{sup –9} cm{sup –1}·W/Hz{sup 1/2}. An Allan variance analysis shows that the system has long-term stability and can serve as the basis for a portable gas analyzer. Approaches to improve the current sensor performance are also discussed. This design greatly reduces the time of manufacturing the microresonator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetization in Nanocrystalline PLD Zinc Ferrite Thin Films Deposited on Fused Quartz Substrate

The nanocrystalline zinc ferrite (ZnFe{sub 2}O{sub 4}) thin films were grown on the fused quartz substrate using pulsed laser deposition. The effects of atmospheric conditions on structural, magnetic, and morphological properties have been systematically studied using X-ray diffraction, vibrating sample magnetometry, and atomic force microscopy. The films showed textured growth of zinc ferrite for the substrate temperatures at ≥ 600 °C irrespective of the ambient environment. Interestingly, thin films of zinc ferrite showed a magnetic hysteresis loop in contrast to the paramagnetic nature of their bulk counterpart. The value of saturation magnetization (4πM{sub s}) increased from 130 to 360 G when the substrate temperature was increased from room temperature (RT) to 800 °C in the oxygen atmosphere. In the absence of oxygen pressure, the value of 4πM{sub s} is observed to be 330 G for the film deposited at RT and found to increase to a value of 670 G when the film is deposited at 400 °C and the maximum value of 2580 G is observed for the film deposited at 700 °C. However, the value of 4πM{sub s} of 800 °C dropped down to 2000 G.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigating calcite growth rates using a quartz crystal microbalance with dissipation (QCM-D)

Calcite precipitation plays a significant role in processes such as geological carbon sequestration and toxic metal sequestration and, yet, the rates and mechanisms of calcite growth under close to equilibrium conditions are far from well understood. In this study, a quartz crystal microbalance with dissipation (QCM-D) was used for the first time to measure macroscopic calcite growth rates. Calcite seed crystals were first nucleated and grown on sensors, then growth rates of calcite seed crystals were measured in real-time under close to equilibrium conditions (saturation index, SI = log ({Ca 2+ }/{CO 3 2– }/ K sp ) = 0.01–0.7, where {i} represent ion activities and K sp = 10 –8.48 is the calcite thermodynamic solubility constant). At the end of the experiments, total masses of calcite crystals on sensors measured by QCM-D and inductively coupled plasma mass spectrometry (ICP-MS) were consistent, validating the QCM-D measurements. Calcite growth rates measured by QCM-D were compared with reported macroscopic growth rates measured with auto-titration, ICP-MS, and microbalance. Calcite growth rates measured by QCM-D were also compared with microscopic growth rates measured by atomic force microscopy (AFM) and with rates predicted by two process-based crystal growth models. The discrepancies in growth rates among AFM measurements and model predictions appear to mainly arise from differences in step densities, and the step velocities were consistent among the AFM measurements as well as with both model predictions. Using the predicted steady-state step velocity and the measured step densities, both models predict well the growth rates measured using QCM-D and AFM. Furthermore, this study provides valuable insights into the effects of reactive site densities on calcite growth rate, which may help design future growth models to predict transient-state step densities.

58 GEOSCIENCES↗

Elucidating mechanisms of oxide growth and surface passivation on zinc thin film electrodes in alkaline solutions using the electrochemical quartz crystal microbalance

For this study, we utilized electrochemical quartz crystal microbalance to understand electrochemical passivation of the zinc electrode in alkaline media and subsequent oxide growth and stripping. The formation of native zinc oxide on a near pristine Zn surface upon contact with 1 M KOH electrolyte was observed. The surface was seen to roughen with time. During Zn dissolution, the measured mass-charge ratio corresponded to the removal of ZnO and not merely Zn. The mechanism of passivation was determined to be caused by electrochemical etching to form pores. The etching leads to a build-up of solid ZnO and Zn(OH) 2 due to electrochemical reactions on the surfaces of the pores. These reactions functionally close the pores off from the bulk. The cycle of Zn deposition and dissolution develops a porous network, which may be the origin of mossy Zn deposits that plague reversible Zn metal batteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Recombination luminescence and trap levels in undoped and Al-doped ZnO thin films on quartz and GaSe (0 0 0 1) substrates

Highlights: Black-Right-Pointing-Pointer ZnO films on GaSe create electron trapping states and PL recombination levels. Black-Right-Pointing-Pointer Zn and Al diffusion in GaSe produces low-energy widening of its PL emission. Black-Right-Pointing-Pointer ZnO:Al films on GaSe lamellas are suitable for gas-discharge lamp applications. -- Abstract: Photoluminescence spectra of ZnO and ZnO:Al (1.00, 2.00 and 5.00 at.%) films on GaSe (0 0 0 1) lamellas and amorphous quartz substrates, obtained by annealing, at 700 K, of undoped and Al-doped metal films, are investigated. For all samples, the nonequilibrium charge carriers recombine by radiative band-to-band transitions with energy of 3.27 eV, via recombination levels created by the monoionized oxygen atoms, forming the impurity band laying in the region 2.00 - 2.70 eV. Al doping induces an additional recombination level at 1.13 eV above the top of the valence band of ZnO films on GaSe substrates. As a result of thermal diffusion of Zn and Al into the GaSe interface layer from ZnO:Al/GaSe heterojunction, electron trap levels located at 0.22 eV and 0.26 eV below the conduction band edge of GaSe, as well as a deep recombination level, responsible for the luminescent emission in the region 1.10 - 1.40 eV, are created.

36 MATERIALS SCIENCE↗

Transport of Strontium and Cesium in Simulated Hanford Tank Waste Leachate through Quartz Sand under Saturated and Unsaturated Flow

We investigated the effects of water saturation and formation of secondary precipitates on transport of Sr and Cs through sand columns under unsaturated water flow. A series of column experiments was run at effective water saturations ranging from 0.2 to 1.0 under steady-state flow using columns filled with quartz sand. The solution phase was either 0.1 M NaNO3 or a simulated tank waste leachate (STWL), mimicking the leaks of tank wastes at the Hanford Site, Washington, USA. In STWL, the mobility of Sr was significantly reduced as the water saturation decreased, because Sr was incorporated into or sorbed to neo-formed secondary precipitates. In contrast, the transport of Cs in STWL was similar to that of a nonreactive tracer. In 0.1 M NaNO3, Sr moved like a conservative tracer, showing no retardation, whereas Cs was retarded relative to Sr. The flow regime for the 0.1 M NaNO3 columns under all water saturations could be described with the equilibrium convection-dispersion equation (CDE). However, for STWL, the Sr and Cs breakthrough curves indicated the presence of non-equilibria under unsaturated flow conditions. Such non-equilibrium conditions, caused by physical and chemical processes can reduce the mobility of radionuclides at the Hanford vadose zone.

54 ENVIRONMENTAL SCIENCES↗

An Investigation of the Influence of Chain Length on the Interfacial Ordering of L-Lysine and L-Proline and Their Homopeptides at Hydrophobic and Hydrophilic Interfaces Studied by Sum Frequency Generation and Quartz Crystal Microbalance

Sum frequency generation vibrational spectroscopy (SFG) and quartz crystal microbalance with dissipation monitoring (QCM-D) are employed to study the interfacial structure and adsorbed amount of the amino acids l-lysine and l-proline and their corresponding homopeptides, poly-l-lysine and poly-l-proline, at two liquid-solid interfaces. SFG and QCM-D experiments of these molecules are carried out at the interface between phosphate buffered saline at pH 7.4 (PBS) and the hydrophobic deuterated polystyrene (d{sub 8}-PS) surface as well as the interface between PBS and hydrophilic fused silica (SiO{sub 2}). The SFG spectra of the amino acids studied here are qualitatively similar to their corresponding homopeptides; however, the SFG signal from amino acids at the solid/PBS interface is smaller in magnitude relative to their more massive homopeptides at the concentrations studied here. Substantial differences are observed in SFG spectra for each species between the hydrophobic d{sub 8}-PS and the hydrophilic SiO{sub 2} liquid-solid interfaces, suggesting surface-dependent interfacial ordering of the biomolecules. Over the range of concentrations used in this study, QCM-D measurements also indicate that on both surfaces poly-l-lysine adsorbs to a greater extent than its constituent amino acid l-lysine. The opposite trend is demonstrated by poly-l-proline which sticks to both surfaces less extensively than its corresponding amino acid, l-proline. Lastly, we find that the adsorption of the molecules studied here can have a strong influence on interfacial water structure as detected in the SFG spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved frequency/voltage converters for fast quartz crystal microbalance applications

The monitoring of frequency changes in fast quartz crystal microbalance (QCM) applications is a real challenge in today's instrumentation. In these applications, such as ac electrogravimetry, small frequency shifts, in the order of tens of hertz, around the resonance of the sensor can occur up to a frequency modulation of 1 kHz. These frequency changes have to be monitored very accurately both in magnitude and phase. Phase-locked loop techniques can be used for obtaining a high performance frequency/voltage converter which can provide reliable measurements. Sensitivity higher than 10 mV/Hz, for a frequency shift resolution of 0.1 Hz, with very low distortion in tracking both the magnitude and phase of the frequency variations around the resonance frequency of the sensor are required specifications. Moreover, the resonance frequency can vary in a broad frequency range from 5 to 10 MHz in typical QCM sensors, which introduces an additional difficulty. A new frequency-voltage conversion system based on a double tuning analog-digital phase-locked loop is proposed. The reported electronic characterization and experimental results obtained with conducting polymers prove its reliability for ac-electrogravimetry measurements and, in general, for fast QCM applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined reflectometry and quartz crystal microbalance with dissipation setup for surface interaction studies

We have developed an instrument for surface interaction studies, which combines a newly invented four detector optical reflectometry setup with quartz crystal microbalance with dissipation (QCM-D) monitoring. The design is such that data from both techniques can be obtained simultaneously on the same sensor surface, with the same signal-to-noise ratio and time resolution, as for the individual techniques. In addition, synchronized information about structural transformations, molecular mass, and the hydration of thin films on solid surfaces can be obtained on the same specimen, as validated by monitoring the formation of supported lipid bilayers on a silica-coated QCM sensor surface. We emphasize that the optical (molecular) mass can be separated from the acoustic mass including hydrodynamically coupled solvent, which means, in turn, that the amount of solvent sensed by the QCM-D technique can be dynamically resolved during adsorption processes. In addition, the advantage/necessity to use four, compared to two, detector reflectometry is emphasized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions

A new configuration of automatic capacitance compensation (ACC) technique based on an oscillatorlike working interface, which permits the tracking of the series resonant frequency and the monitoring of the motional resistance and the parallel capacitance of a thickness-shear mode quartz crystal microbalance sensor, is introduced. The new configuration permits an easier calibration of the system which, in principle, improves the accuracy. Experimental results are reported with 9 and 10 MHz crystals in liquids with different parallel capacitances which demonstrate the effectiveness of the capacitance compensation. Some frequency deviations from the exact series resonant frequency, measured by an impedance analyzer, are explained by the specific nonideal behavior of the circuit components. A tentative approach is proposed to solve this problem that is also common to previous ACC systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-scan measurement of conductance of a quartz crystal microbalance array coupled with resonant markers for biosensing in liquid phase

This work presents a method for sensing the viscoelastic property of liquid/solid interface using a quartz crystal microbalance (QCM) array. Each sensor in a QCM array has a unique resonant frequency and can be identified by a single-scan measurement of admittance (or impedance). The resonant frequency encoding at each sensor in an array was realized by connecting a capacitor with a known capacitance, called a resonant marker, to the sensor in series. Changes in the resonant frequency of all sensors in an array can be determined using an impedance analyzer and a program that determines the frequencies at which the conductance is at a local maximum. The sensing method allows every sensor output (resonant frequency) to be obtained without the use of time-consuming multiplexed hardware and software. Adsorptions of biomolecules by multiple sensor are monitored in the liquid phase to demonstrate the feasibility of frequency encoding using resonant markers and the single-scan measurement of conductance of a QCM array.

36 MATERIALS SCIENCE↗