Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Prototype”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beam test performance of a prototype module with Short Strip ASICs for the CMS HL-LHC tracker upgrade

The Short Strip ASIC (SSA) is one of the four front-end chips designed for the upgrade of the CMS Outer Tracker for the High Luminosity LHC. Together with the Macro-Pixel ASIC (MPA) it will instrument modules containing a strip and a macro-pixel sensor stacked on top of each other. The SSA provides both full readout of the strip hit information when triggered, and, together with the MPA, correlated clusters called stubs from the two sensors for use by the CMS Level-1 (L1) trigger system. Results from the first prototype module consisting of a sensor and two SSA chips are presented. The prototype module has been characterized at the Fermilab Test Beam Facility using a 120 GeV proton beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

System design and prototyping for the CMS Level-1 Trigger at the High-Luminosity LHC

For the High-Luminosity Large Hadron Collider, the trigger and data acquisition system of the CMS experiment will be entirely replaced. Novel design choices have been explored, including ATCA prototyping platforms with SoC controllers and newly available interconnect technologies with serial optical links with data rates up to 28 Gb/s. Trigger analyses will be performed through sophisticated algorithms, including widespread use of Machine Learning, in large FPGAs, such as the Xilinx Ultrascale family. The system will process over 50 Tb/s of detector data with an event rate of 750 kHz. Here, we describe system design and prototyping and review trigger algorithm exemplars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to -125 dB re V2/μPa2 in a frequency range of 10–40 kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately 230–280 μs at distances of up to 1600 m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

Data analysis↗

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

43 PARTICLE ACCELERATORS↗

Design, construction and commissioning of the proximity cryogenics systems serving two large-scale prototypes of the future DUNE neutrino detector

In the context of the Neutrino Platform, CERN has designed, constructed, and commissioned the proximity cryogenics systems that serve two CERN based large-scale prototypes of future neutrino detectors. Each of these prototypes features a high voltage time projection chamber placed inside a membrane cryostat being submerged in 600m3 of liquid argon at about 1.0 bar. A copper and molecular sieve based cryogenic purification system has to ensure that the argon in the cryostat has a contamination level below 100 ppt oxygen equivalent. The two proximity cryogenics systems provide the purging, cool-down, filling, normal operation and emptying modes for each cryostat. This paper reports on the design, construction and commissioning of the ProtoDUNE proximity cryogenics facilities.

43 PARTICLE ACCELERATORS↗

High-gradient performance of a prototype accelerator cavity for a 3 GeV proton radiography booster

This paper reports the design, fabrication, and results of the high-gradient conditioning and testing for a two-cell, π -mode, standing wave normal-conducting prototype booster cavity for the proposed 3 GeV proton linac upgrade at Los Alamos Neutron Science Center. Increasing the energy of proton beam from the existing 800 MeV to 3 GeV will improve resolution of the proton radiography by up to 10 times. The proposed energy boost can be achieved with a compact normal-conducting high-gradient radio-frequency (rf) linac section. The C-band section of the booster linac was designed with optimized-shaped copper accelerator cavities with distributed rf coupling. A short two-cell test prototype structure was designed for the frequency of 5.712 GHz, fabricated, and tested at the C-band Engineering Research Test Facility in New Mexico (CERF-NM) at Los Alamos National Laboratory. The maximum klystron power coupled into the test structure was 8.3 MW with 1 μ s pulse length and 100 Hz repetition rate. The breakdown probabilities were recorded as functions of the accelerating gradient and peak surface fields. Operation of the test cavity at accelerating gradients of up to 100 MV / m was demonstrated. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

First Search for Dark Photon Dark Matter with a madmax Prototype

We report the first result from a dark photon dark matter search in the mass range from 78.62 to 83.95 μ eV / c 2 with a dielectric haloscope prototype for (Magnetized Disc and Mirror Axion eXperiment). Putative dark photons would convert to detectable photons within a stack consisting of three sapphire disks and a mirror. The emitted power of this system is received by an antenna and successively digitized using a low-noise receiver. No significant signal attributable to dark photons has been observed above the expected background. Assuming unpolarized dark photon dark matter with a local density of ρ χ = 0.3 G eV cm 3 we exclude a dark photon to photon mixing parameter χ > 2.7 × 10 − 12 over the full mass range and χ > 1.1 × 10 − 13 at a mass of 80.57 μ eV / c 2 with a 95% confidence level. This is the first physics result from a prototype and exceeds previous constraints on χ in this mass range by up to almost three orders of magnitude. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distributing Power Grid State Estimation on HPC Clusters A System Architecture Prototype

The future power grid is expected to further expand with highly distributed energy sources and smart loads. The increased size and complexity lead to increased burden on existing computational resources in energy control centers. Thus the need to perform real-time assessment on such systems entails efficient means to distribute centralized functions such as state estimation in the power system. In this paper, we present our early prototype of a system architecture that connects distributed state estimators individually running parallel programs to solve non-linear estimation procedure. The prototype consists of a middleware and data processing toolkits that allows data exchange in the distributed state estimation. We build a test case based on the IEEE 118 bus system and partition the state estimation of the whole system model to available HPC clusters. The measurement from the testbed demonstrates the low overhead of our solution.

Distributed architecture↗

Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotational coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype tests results

The Fermilab Mu2e experiment has been developed to search for evidence of charged lepton flavor violation through the direct conversion of muons into electrons. The transport solenoid is an s-shaped magnet which guides the muons from the source to the stopping target. It consists of fifty-two superconducting coils arranged in twenty-seven coil modules. A full-size prototype coil module, with all the features of a typical module of the full assembly, was successfully manufactured by a collaboration between INFN-Genoa and Fermilab. The prototype contains two coils that can be powered independently. In order to validate the design, the magnet went through an extensive test campaign. Warm tests included magnetic measurements with a vibrating stretched wire, electrical and dimensional checks. As a result, the cold performance was evaluated by a series of power tests as well as temperature dependence and minimum quench energy studies.

43 PARTICLE ACCELERATORS↗

Mu2e transport solenoid prototype design and manufacturing

The Mu2e Transport Solenoid consists of 52 coils arranged in 27 coil modules that form the S-shaped cold mass. Each coil is wound from Al-stabilized NbTi superconductor. The coils are supported by an external structural aluminum shell machined from a forged billet. Most of the coil modules house two coils, with the axis of each coil oriented at an angle of approximately 5° with respect to each other. The coils are indirectly cooled with LHe circulating in tubes welded on the shell. In order to enhance the cooling capacity, pure aluminum sheets connect the inner bore of the coils to the cooling tubes. The coils are placed inside the shell by the means of a shrink-fit procedure. A full-size prototype, with all the features of the full assembly, was successfully manufactured in a collaboration between INFN Genova and Fermilab. In order to ensure an optimal mechanical prestress at the coil-shell interface, the coils are inserted into the shell through a shrink-fitting process. We present the details of the prototype with the design choices as validated by the structural analysis. In conclusion, the fabrication steps are described as well.

43 PARTICLE ACCELERATORS↗

Localization of quenches and mechanical disturbances in the Mu2e transport solenoid prototype using acoustic emission technique

Acoustic emission (AE) detection is a noninvasive technique allowing the localization of the mechanical events and quenches in superconducting magnets. Application of the AE technique is especially advantageous in situations where magnet integrity can be jeopardized by the use of voltage taps or inductive pickup coils. As the prototype module of the transport solenoid (TS) for the Mu2e experiment at Fermilab represents such a special case, we have developed a dedicated six-channel AE detection system and accompanying software aimed at localizing mechanical events during the coil cold testing. The AE sensors based on transversely polarized piezoceramic washers combined with cryogenic preamplifiers were mounted at the outer surface of the solenoid aluminum shell, with a 60° angular step around the circumference. Acoustic signals were simultaneously acquired at a rate of 500 kS/s, prefiltered and sorted based on their arrival time. Next, based on the arrival timing, angular and axial coordinates of the AE sources within the magnet structure were calculated. Furthermore, we present AE measurement results obtained during cooldown, spot heater firing, and spontaneous quenching of the Mu2e TS module prototype and discuss their relevance for mechanical stability assessment and quench localization.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Results From a Prototype Combination TPC Cherenkov Detector With GEM Readout

A combined time projection chamber-Cherenkov (TPCC) prototype detector has been developed as part of the detector research and development program for a future electron-ion collider (E!C). The prototype was tested at the Fermilab test beam facility (FTBF) to provide a proof of the principle to demonstrate the ability to measure particle tracks and provide particle identification (P!D) information within a common detector volume. The time projection chamber (TPC) portion consists of a 10 × 10 × 10 cm 3 field cage, which delivers charge from tracks to a quadruple gas electron multiplier (GEM) with zigzag-shaped charge collection anodes. The Cherenkov portion consists of a photosensitive quadruple GEM detector with a Cs! photocathode. As tracks pass through the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the Cs! photocathode. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF 4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, including the position resolution as well as the particle id capabilities of the detector, are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CDP1—A Data Concentrator Prototype for the Deep Underground Neutrino Experiment

The design, power analysis and tests of a first COLDATA Prototype (CDP1) design in 65nm process for the Long Baseline Neutrino Facility (LBNF) and the Deep Underground Neutrino Experiment (DUNE) are presented here. CDP1 is a prototype ASIC, for the COLDATA chip, a data concentrator operated in liquid argon. Furthermore, CDP1 is a test vehicle to qualify most of the analog and digital blocks such as LVDS transmitters and receivers, a 1.28 Gbps serializer, a phase locked loop, I 2 C for slow control, fast command receiver and calibration logic at cryogenic temperature. Finally, the test measurements of these blocks are carried out at room temperature (300K) and at cryogenic temperature (77K). The test measurements presented in this article are in good agreement with the simulation results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗