Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A Search for Signs of Life and Habitability on Europa

Europa is a key target in the search for life beyond the Earth because of consistent evidence that below the icy surface there is liquid water. Future missions to Europa could confirm the presence and nature of the ocean and determine the thickness of the ice layer. Confirming the presence of an ocean and determining the habitability of Europa are key astrobiology science objectives. Nevertheless, the highest priority objective for astrobiology will be a search for life. How could a search for life be accomplished on a near-term mission given the thick ice cover? One answer may lie in the surface materials. If Europa has an ocean, and if that ocean contains life, and if water from the ocean is carried up to the surface, then signs of life may be contained in organic material on the surface. Organics that derive from biological processes (dead organisms) are distinct from organics derived from non-biological processes in several aspects. First, biology is selective and specific in its use of molecules. For example, Earth life uses 20 left-handed amino acids. Second, biology can leave characteristic isotopic patterns. Third, biology often produces large complex molecules in high concentrations, for example lipids. Organic material that has been on the surface of Europa for long periods of time would be reprocessed by the strong radiation field probably erasing any signature of biological origin. Evidence of life in the ocean may be found on the surface of Europa if regions of the surface contained relatively recent material carried up from the ocean through cracks in the icy lithosphere. But organic material that has been on the surface of Europa for long periods of time would be reprocessed by the strong radiation field probably erasing any signature of biological origin. Thus, the detailed analysis required may not be possible via remote sensing but direct sampling of the material below the radiation processed upper meter is probably required.

Fonda, Mark↗

Containerless processing of undercooled melts

Containerless drop tube processing allows for significant levels of liquid undercooling through control of parameters such as sample size, surface coating and cooling rate. A laboratory scale (3 m) drop tube has been developed which allows the undercooling and solidification behavior of powder samples to be evaluated under low gravity free-fall conditions. The level of undercooling obtained in an InSb-Sb eutectic alloy has been evaluated by comparing the eutectic spacing in drop tube samples with a spacing/undercooling relationship established using thermal analysis techniques. Undercoolings of 0.17 and 0.23 T(e) were produced by processing under vacuum and He gas conditions respectively. Alternatively, the formation of an amorphous phase in a Ni-Nb eutectic alloy indicates that undercooling levels of approximately 500 C were obtained by drop tube processing. The influence of droplet size and gas environment on undercooling behavior in the Ni-Nb eutectic was evaluated through their effect on the amorphous/crystalline phase ratio. To supplement the structural analysis, heat flow modeling has been developed to describe the undercooling history during drop tube processing, and the model has been tested experimentally.

Shong, D. S.↗

The Mars Science Laboratory Organic Check Material

The Organic Check Material (OCM) has been developed for use on the Mars Science Laboratory mission to serve as a sample standard for verification of organic cleanliness and characterization of potential sample alteration as a function of the sample acquisition and portioning process on the Curiosity rover. OCM samples will be acquired using the same procedures for drilling, portioning and delivery as are used to study martian samples with The Sample Analysis at Mars (SAM) instrument suite during MSL surface operations. Because the SAM suite is highly sensitive to organic molecules, the mission can better verify the cleanliness of Curiosity's sample acquisition hardware if a known material can be processed through SAM and compared with the results obtained from martian samples.

Conrad, Pamela G.↗

An analytical approach to thermal modeling of Bridgman-type crystal growth. I - One-dimensional analysis

A relatively simple one-dimensional thermal model of the Bridgman growth process has been developed which is applicable to the growth of small diameter samples with conductivities similar to those of metallic alloys. The heat flow in a translating rod is analyzed in a way that is applicable to Biot numbers less than unity. The model accommodates an adiabatic zone, different heat transfer coefficients in the hot and cold zones, and changes in sample material properties associated with phase change. The analysis is applied to several simplified cases. The effect of the rod's motion is studied in a three-zone furnace for a rod sufficiently long that end effects can be neglected; end effects are then investigated for a motionless rod. Finally, the addition of a fourth zone, an independently controlled booster heater between the main heater and the adiabatic zone, is evaluated for its ability to increase the gradient in the sample at the melt interface and to control the position of the interface.

Naumann, R. J.↗

NASA EVM Overview and Case Study

The presentation gives an overview of the National Aeronautics and Space Administration (NASA) Earned Value Management (EVM) structure. We briefly talk about the current EVM high-level policies within NASA and the EVM governing structure. It touches on the roles and responsibilities of EVM Focal Points within the Agency. We will also discuss the approach that MSFC followed in implementing EVM and better data analysis within the Habitat Holding Racks (HHR) Project. We will address the approach used at the Marshall Space Flight Center (MSFC) to effectively equip and support MSFC projects in applying a sound EVM and data analysis process. In addition, we will show metrics associated with the HHR project before and after the implementation of EVM on the project. We will discuss the monthly report, using sample data, that the project manager used each month to assess the performance of the project. The data received from EVM helped create a solid method for assessing the project s performance. The use of EVM data analysis can be an effective and efficient tool in today s environment with increasing workloads and downsizing workforces. EVM provides project managers with information that can be used in the decision making process.

Kerby, Jerald G.↗

2023 Cleanroom Monitoring for OSIRIS-REx

OSIRIS-REx is an asteroid sample return mission that delivered asteroid regolith from Bennu to Earth on 9/24/2023 [1]. Cleanroom monitoring of OSIRIS-REx Curation facilities has been ongoing since 2021 when construction of the OSIRIS-REx lab at Johnson Space Center (JSC) was completed [2]. The monitoring continues inside of the OSIRIS-REx lab in Houston. Monitoring was also conducted on a temporary cleanroom constructed inside a hangar at the Utah Test and Training Range (UTTR) to initially receive the Sample Return Capsule (SRC) upon its landing there. The following reports on cleanroom monitoring that has taken place in the months leading up to as well as after OSIRIS-REx return. Monitoring techniques used include particle counts, deployment of Si wafer witness plates (Balazs, Inc.) and Al foil witness plates, gas sampling (Balazs, Inc.) and microbiological monitoring. We collected particle counts at both the lab at JSC as well as the temporary cleanroom at UTTR. Particle counts were taken monthly from six locations in the lab at JSC. Particle counts were taken from seven locations at UTTR in July, August, and September. The UTTR cleanroom particle counts were taken daily in the five days leading to OSIRIS-REx return as well as consistently the day of return (every 2 minutes and 15 seconds 7:21 am- 6:27 pm) from one location inside the cleanroom. The particle counts at UTTR consistently stayed well within the ranges of its required ISO 7 equivalent classification (352,000 maximum particles/ m3 ≥ 0.5 μm). Most analysis showed that the particle counts were far below ISO 7 requirements (highest measured count was 61,484 particles/ m3 ≥ 0.5 um). but the elevated instances correlated to exterior hangar doors being open. Particle counts were reduced when keeping exterior hangar doors closed. The particle counts at JSC have stayed consistently within their ISO 5 equivalent classification (3,520 maximum particles/ m3 ≥ 0.5 um). In most instances, the counts are much better except in one instance where the count measured 13,381 particles/ m3 ≥ 0.5 um. The high spike in particle counts in the JSC lab correlated with the air handlers being shut down temporarily the previous day. The particle counts taken in the same location quickly reduced and measured 0 when taken a month later with the air handlers on. We deployed 8-inch semiconductor polished Si wafer witness plates for 24-hour periods inside of the OSIRIS-REx Curation lab at JSC (in July, August, September, and November 2023) and the cleanroom at UTTR (July and September 2023) to test for possible organic and inorganic contaminants. We also deployed these wafers inside of the OSIRIS-REx Touch-and-Go sample Acquisition Mechanism (TAGSAM) glovebox (where Bennu sample processing occurs) and desiccator (Bennu sample storage) at JSC in August 2023. These samples were all sent to Balazs for analysis via Thermal Desorption Gas Chromatography Mass Spectroscopy (TD-GC-MS) to quantify organic compounds and vapor phase decomposition inductively coupled plasma mass spectrometry (VPD-ICP-MS) to quantify inorganic contaminants. We collected air samples using an adsorbent tube connected to a pump for six hours (100 mL/minute) inside of both the JSC lab and the UTTR cleanroom. These samples were taken at JSC in July, August, September, November, and December and at UTTR in July and September. Additionally, a sample was taken just outside of the TAGSAM glovebox airlock door in July. These samples were sent to Balazs for analysis of volatile organics in air. Overall, the OSIRIS-REx lab at JSC and cleanroom at UTTR yielded very low organic and inorganic contaminants (similar results to Genesis lab at JSC which is ISO 4 equivalent) except for boron, which is attributed to the borosilicate glass in the fan filter units. We collected monthly surface and air samples inside the JSC lab to monitor potential microbial contamination. We report the recovery rate for each sampling event, which is defined as the number of samples exhibiting bacterial or fungal growth divided by the total number of samples collected. Since the lab was commissioned in 2021 the median recovery rate is 29%. This recovery rate is consistent with other ISO 5 equivalent labs used to curate astromaterials collections. Increases in recovery rate correspond to construction and/or extra activity in the lab. However, increases in recovery rate do not reliably correlate to increases in particle counts, which highlights the need for a dedicated microbial monitoring program for biologically sensitive collections. We sampled the temporary clean room at UTTR in July, August, and September of 2023 to monitor potential microbial contamination. The recovery rate decreased from 80% in August to 29% in September. However, in all instances, the diversity of bacteria and fungi was higher in the UTTR cleanroom than in the JSC lab. We routinely collected more than twenty different organisms from the UTTR cleanroom. In the JSC lab the median diversity is 2 organisms. Based on these results we hypothesize that microbes from UTTR could be transported back to JSC with the Bennu samples. To mitigate this risk, in September of 2023, we implemented additional cleaning procedures in the JSC lab to reduce the bioburden on surfaces that could come into direct contact with hardware used to process Bennu samples. Since adopting these additional cleaning measures, the median recovery rate has decreased to 14%. We did not observe an increase in fungal or bacterial diversity in the lab in the October sampling. We will continue to monitor this trend closely for the next several months. Supported by NASA under Award NNH09ZDA007O and Contract NNM10AA11C.

Rachel Comstock Funk↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Fluid Phase Separation (FPS) experiment for flight on the shuttle in a Get Away Special (GAS) canister: Design and fabrication

The separation of fluid phases in microgravity environments is of importance to environmental control and life support systems (ECLSS) and materials processing in space. A successful fluid phase separation experiment will demonstrate a proof of concept for the separation technique and add to the knowledge base of material behavior. The phase separation experiment will contain a premixed fluid that will be exposed to a microgravity environment. After the phase separation of the compound has occurred, small samples of each of the species will be taken for analysis on Earth. By correlating the time of separation and the temperature history of the fluid, it will be possible to characterize the process. The phase separation experiment is totally self-contained, with three levels of containment on all fluids, and provides all necessary electrical power and control. The controller regulates the temperature of the fluid and controls data logging and sampling. An astronaut-activated switch will initiate the experiment and an unmaskable interrupt is provided for shutdown. The experiment has been integrated into space available on a manifested Get Away Special (GAS) experiment, CONCAP 2, part of the Consortium for Materials Complex Autonomous Payload (CAP) Program, scheduled for STS 42 in April 1991. Presented here are the design and the production of a fluid phase separation experiment for rapid implementation at low cost.

Source record↗

Linking Home Plate and Algonquin Class Rocks through Microtextural Analysis: Evidence for Hydrovolcanism in the Inner Basin of Columbia Hills, Gusev Crater

Examining the his-tory of a rock as the summed history of its constituent grains is a proven and powerful strategy that has been used on Earth to maximize the information that can be gleaned from limited samples. Grain size, sorting, roundness, and texture can be observed at the handlens scale, and may reveal clues to transport regime (e.g. fluvial, glacial, eolian) and transport distance. Diagenetic minerals may be of a form and textural context to allow identification, and to point to dominant diagenetic processes (e.g. evaporitic concentration, intermittent dissolution, early vs. late diagenetic emplacement). Handlens scale features of volcaniclastic particles may be diagnostic of primary vs recycled (by surface processes) grains and may provide information about eruptive patterns and processes. When the study site is truly remote, such as Mars, and when there are severe limitations on sample return or sample analysis with other methods, examination at the hand lens scale becomes critical both for extracting a maximum of information, and for best utilizing finite analytical capabilities.

Mittlefehldt, David W.↗

Thermogravimetric-quadrupole mass-spectrometric analysis of geochemical samples.

Thermogravimetric-quadrupole mass-spectrometric-analysis techniques can be used to study a wide variety of problems involving decomposition processes and identification of released volatile components. A recording vacuum thermoanalyzer has been coupled with a quadrupole mass spectrometer. The rapid scan capabilities of the quadrupole mass spectrometer are used to identify the gaseous components released. The capability of the thermogravimetric-quadrupole mass spectrometer to provide analytical data for identification of the released volatile components, for determination of their sequence of release and for correlation of thermal-decomposition studies is illustrated by an analysis of the Orgueil carbonaceous chondrite.

Gibson, E. K., Jr.↗

NCUBE - A clustering algorithm based on a discretized data space

Cluster analysis involves the unsupervised grouping of data. The process provides an automatic procedure for generating known training samples for pattern classification. NCUBE, the clustering algorithm presented, is based upon the concept of imposing a gridwork on the data space. The NCUBE computer implementation of this concept provides an easily derived form of piecewise linear discrimination. This piecewise linear discrimination permits the separation of some types of data groups that are not linearly separable.

Eigen, D. J.↗

Evaluation of film type QX 807 (SO-368, Kodak Ektachrome MS, Estar thin base, with an equivalent Wratten 2A filter overcoat)

A color film with a sensitivity and color balance equal to SO-368, Kodak MS Ektachrome (Estar thin base) was required for use on the Apollo-Soyuz test project (ASTP). A Wratten 2A filter was required for use with the film to reduce short wavelength effects which frequently produce a blue color balance in aerial photographs. The background regarding a special emulsion which was produced with a 2A filter equivalent as an integral part of an SO-368 film manufactured by Eastman Kodak, the cost for production of the special film, and the results of a series of tests made within PTD to certify the film for ASTP use are documented. The tests conducted and documented were physical inspection, process compatibility, effective sensitivity, color balance, cross section analysis, resolution, spectral sensitivity, consistency of results, and picture sample analysis.

Lockwood, H. E.↗

Soot Precursor Material: Visualization Via Simultaneous LIF-LII and Characterization Via TEM

Simultaneous combined laser-induced fluorescence and laser-induced incandescence (LIF-LII) images are presented for both a normal and inverse diffusion flame. The excitation wavelength dependence distinguishes the LIF and LII signals in images from the normal diffusion flame while the temporal decay distinguishes the signals in images of the inverse diffusion flame. Each flame presents a minimum in the combined LIF-LII intensity in a region separating the fuel pyrolysis and soot containing regions. Opacity, geometric in definition, and extent of crystallinity measured through both bright and dark field Transmission Electron Microscopy (TEM) characterizes the thermophoretically sampled material from within this minimal LIF-LII intensity region. TEM analysis reveals rather different soot processes occurring within the normal and inverse diffusion flame. In the normal diffusion flame, rapid chemical and physical coalescence of PAHs results in initial formation of soot precursor particles that are highly crystalline and evolve toward fully formed soot. In the inverse diffusion flame, rapid coalescence of pyrolysis products occurs, producing tarlike, globular structures equivalent in size to fully formed soot aggregates but with markedly less crystallinity than normal-appearing soot. These different material properties are interpreted as reflecting different relative rates of chemical and physical coalescence of fuel pyrolysis products versus carbonization. Significantly, these TEM images support qualitative photophysical arguments suggesting that, in general, this 'dark' region observed in the LIF-LII images demarcates a transitional region in which a fundamental change in the material the material chemical/physical properties occurs between solid carbonaceous soot and condensed or gaseous molecular growth material.

VanderWal, Randall L.↗

Experimental Investigations of Non-Stationary Properties In Radiometer Receivers Using Measurements of Multiple Calibration References

Radiometers must be periodically calibrated because the receiver response fluctuates. Many techniques exist to correct for the time varying response of a radiometer receiver. An analytical technique has been developed that uses generalized least squares regression (LSR) to predict the performance of a wide variety of calibration algorithms. The total measurement uncertainty including the uncertainty of the calibration can be computed using LSR. The uncertainties of the calibration samples used in the regression are based upon treating the receiver fluctuations as non-stationary processes. Signals originating from the different sources of emission are treated as simultaneously existing random processes. Thus, the radiometer output is a series of samples obtained from these random processes. The samples are treated as random variables but because the underlying processes are non-stationary the statistics of the samples are treated as non-stationary. The statistics of the calibration samples depend upon the time for which the samples are to be applied. The statistics of the random variables are equated to the mean statistics of the non-stationary processes over the interval defined by the time of calibration sample and when it is applied. This analysis opens the opportunity for experimental investigation into the underlying properties of receiver non stationarity through the use of multiple calibration references. In this presentation we will discuss the application of LSR to the analysis of various calibration algorithms, requirements for experimental verification of the theory, and preliminary results from analyzing experiment measurements.

Racette, Paul↗

Soot Optical Property Study

Recent past studies of soot reaction processes in laminar premixed and nonpremixed flames generally have used the intrusive technique of thermophoretic sampling and analysis by transmission electron microscopy (TEM) to observe soot structure and obtain important fundamental information about soot particle properties, such as soot primary particle diameters, the rate of change of soot primary particle diameter as a function of time (or rate of soot surface growth or oxidation), the amount of soot particle reactive surface area per unit volume, the number of primary soot particles per unit volume, and the rate of formation of primary soot particles (or the rate of soot primary particle nucleation). Given the soot volume per unit volume of the flame (or the soot volume fraction), all these properties are readily found from a measurement of the soot primary particle diameter (which usually is nearly a constant for each location within a laminar flame). This approach is not possible within freely propagating flames, however, because soot properties at given positions in such flames vary relatively rapidly as a function of time in the soot formation and oxidation regions compared to the relatively lengthy sampling times needed to accumulate adequate soot samples and to minimize effects of soot collected on the sampling grid as it moves to and from the sampling position through other portions of the flame. Thus, nonintrusive optical methods must be used to find the soot primary particle diameters needed to define the soot surface reaction properties mentioned earlier. Unfortunately, approximate nonintrusive methods used during early studies of soot reaction properties in flames, found from laser scattering and absorption measurements analyzed assuming either Rayleigh scattering or Mie scattering from polydisperse effective soot particles having the same mass of soot as individual soot aggregates, have not been found to be an effective way to estimate the soot surface reaction area per unit volume. Thus, alternative nonintrusive optical methods of finding these properties must be sought, which was the objective of this phase of the investigation. The alternative method used here involves use of the Rayleigh-Debye-Gans-Polydisperse-Fractal-Aggregate (RDG-PFA) scattering approximation for soot aggregates in flames. Thus, the development of this method will be discussed next before describing its evaluation as a means of nonintrusively measuring soot primary particle diameters in soot-containing flames.

Aung, K. T.↗

Sample Handling and Processing on Mars for Future Astrobiology Missions

In most analytical investigations, there is a need to process complex field samples for the unique detection of analytes especially when detecting low concentration organic molecules that may identify extraterrestrial life. Sample processing for analytical instruments is time, resource and manpower consuming in terrestrial laboratories. Every step in this laborious process will have to be automated for in situ life detection. We have developed, and are currently demonstrating, an automated wet chemistry preparation system that can operate autonomously on Earth and is designed to operate under Martian ambient conditions. This will enable a complete wet chemistry laboratory as part of future missions. Our system, namely the Automated Sample Processing System (ASPS) receives fines, extracts organics through solvent extraction, processes the extract by removing non-organic soluble species and delivers sample to multiple instruments for analysis (including for non-organic soluble species).

Beegle, Luther↗

Palmer Station, Antarctica: A Ground-Based Spaceflight Analog Suitable for Validation of Biomedical Countermeasures for Deep Space Missions

Astronauts are known to exhibit a variety of immunological alterations during spaceflight including changes in leukocyte distribution and plasma cytokine concentrations, a reduction in T-cell function, and subclinical reactivation of latent herpesviruses. These alterations are most likely due to mission-associated stressors including circadian misalignment, microgravity, isolation, altered nutrition, and increased exposure to cosmic radiation. Some of these stressors may also occur in terrestrial situations. This study sought to determine if crewmembers performing overwinter deployment at Palmer Station, Antarctica displayed similar immune alterations. The larger goal was to validate a ground analog suitable for the evaluation of countermeasures designed to protect astronauts during future deep space missions. For this pilot study, plasma, saliva, hair, and health surveys were collected from Palmer Station, Antarctica winterover participants at baseline, and at five overwinter timepoints. Twenty-six subjects consented to participate over the course of two seasons. Initial sample processing was performed at Palmer, and eventually stabilized samples were returned to the Johnson Space Center for analysis. A white blood cell differential was performed (real time) using a fingerstick blood sample to determine alterations in basic leukocyte subsets throughout the winterover. Plasma and saliva samples were analyzed for 30 and 13 cytokines, respectively. Saliva was analyzed for cortisol concentration and three latent herpesviruses (DNA by qPCR), EBV, HSV1, and VZV. Hair samples were analyzed for several hormones, as a measure of stress over prolonged periods of time. Voluntary surveys related to general health and adverse clinical events were distributed to participants. It is noteworthy that due to logistical constraints due to COVID-19, the baseline samples for each season were collected in Punta Arenas, Chile, after long international travel and during isolation. Therefore, the palmer pre mission samples may not reflect a true normal ‘baseline’. Minimal alterations were observed in leukocyte distribution during overwinter. The mean percentage of monocyte concentration elevated at one timepoint. Plasma G-CSF, IL1RA, MCP-1, MIP-1β, TNFα and VEGF were decreased during at least one overwinter timepoint, whereas RANTES was significantly increased. No statistically significant changes were observed in mean saliva cytokine concentrations. Salivary cortisol was substantially elevated throughout the entire winterover compared to baseline. Compared to shedding levels observed in healthy controls (23%), the percentage of participants who shed EBV was higher throughout all winterover timepoints (52-60%). Five subjects shed HSV1 during at least one timepoint throughout the season compared to no subjects shedding during pre-deployment. Finally, VZV reactivation, common in astronauts but exceptionally rare in ground-based stress analogs, was observed in one subject during pre-deployment and a different subject at WO2 and WO3. These pilot data, somewhat influenced by the COVID-19 situation, do suggest that participants at Palmer Station do undergo immunological alterations similar to, but likely in reduced magnitude, as those observed in astronauts. We suggest that overwinter at Palmer Station may be suitable test analog for spaceflight biomedical countermeasures designed to mitigate clinical risks for deep space missions.

Space↗

Lifetimes of Overshooting Convective Events using High-Frequency Gridded Radar Composites

Deep convection that penetrates the tropopause, referred to here as overshooting convection, is capable of lifting tropospheric air well into the stratosphere. In addition to water, these overshoots also transport various chemical species, affecting chemistry and radiation in the stratosphere. It is not currently known, however, how much transport is a result of this mechanism. To better understand overshooting convection, this study aims to characterize the durations of overshooting events. To achieve this, radar data from the Next Generation Weather Radar (NEXRAD) network is composited onto a three-dimensional grid at 5-min intervals. Overshoots are identified by comparing echo-top heights with tropopause estimates derived from ERA5 reanalysis data. These overshoots are linked in space from one analysis time to the next to form tracks. This process is performed for 12 four-day sample windows in the months May–August of 2017–19. Track characteristics such as duration, overshoot area, tropopause-relative altitude, and column-maximum reflectivity are investigated. Positive correlations are found between track duration and other track characteristics. Integrated track volume is found as a product of the overshoot area, depth, and duration, and provides a measure of the potential stratospheric impact of each track. Short-lived tracks are observed to contribute the most total integrated volume when considering track duration, while tracks that overshoot by 2–3 km show the largest contribution when considering overshoot depth. A diurnal cycle is observed, with peak track initiation around 1600–1700 local time. Track-mean duration peaks a few hours earlier, while track-mean area and tropopause-relative height peak a few hours later.

Atmosphere↗