Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Study of ${\mathrm{B}}_{\mathrm{s}}^0$ → J/ψπ + π – K + K – decays

The decays ${\mathrm{B}}_{\mathrm{s}}^0$ → J/ψπ + π – K + K – are studied using a data set corresponding to an integrated luminosity of 9 fb –1 , collected with the LHCb detector in proton-proton collisions at centre-of-mass energies of 7, 8 and 13 TeV. The decays ${\mathrm{B}}_{\mathrm{s}}^0$ → $\mathrm{J}/{ψ \mathrm{K}}^{\ast 0}{\overline{\mathrm{K}}}^{\ast 0}$ and ${\mathrm{B}}_{\mathrm{s}}^0$ → χ c1 (3872)K + K – , where the K + K – pair does not originate from a Φ meson, are observed for the first time. Precise measurements of the ratios of branching fractions between intermediate χ c1 (3872)Φ, $\mathrm{J}/{ψ \mathrm{K}}^{\ast 0}{\overline{\mathrm{K}}}^{\ast 0}$, ψ(2S)Φ and χ c1 (3872)K + K – states are reported. A structure, denoted as X(4740), is observed in the J/ψΦ mass spectrum and, assuming a Breit-Wigner parameterisation, its mass and width are determined to be ${\displaystyle \begin{array}{c}{m}_{\mathrm{X}(4740)}=4741\pm 6\pm 6\kern0.5em \mathrm{MeV}/{c}^2,\\ {}{\Gamma}_{\mathrm{X}(4740)}=53\pm 15\pm 11\kern0.5em \mathrm{MeV},\end{array}}$ where the first uncertainty is statistical and the second is systematic. In addition, the most precise single measurement of the mass of the ${\mathrm{B}}_{\mathrm{s}}^0$ meson is performed and gives a value of ${m}_{{\mathrm{B}}_{\mathrm{s}}^0}=5366.98\pm 0.07\pm 0.13\kern0.5em \mathrm{MeV}/{c}^2.$

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Learning physics at future $e^–e^+$ colliders with machine

Information deformation and loss in jet clustering are one of the major limitations for precisely measuring hadronic events at future $e^–e^+$ colliders. Because of their dominance in data, the measurements of such events are crucial for advancing the precision frontier of Higgs and electroweak physics in the next decades. We show that this difficulty can be well-addressed by synergizing the event-level information into the data analysis, with the techniques of deep neutral network. In relation to this, we introduce a CMB-like observable scheme, where the event-level kinematics is encoded as Fox-Wolfram (FW) moments at leading order and multi-spectra of spherical harmonics at higher orders. Then we develop a series of jet-level (w/ and w/o the FW moments) and event-level classifiers, and analyze their sensitivity performance comparatively with two-jet and four-jet events. As an application, we analyze measuring Higgs decay width at $e^–e^+$ colliders with the data of 5ab –1 @240GeV. The precision obtained is significantly better than the baseline ones presented in documents. We expect this strategy to be applied to many other hadronic- event measurements at future $e^–e^+$ colliders, and to open a new angle for evaluating their physics capability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Determination of the $^8\mathrm{B}$ neutrino energy spectrum using trapped ions

We report the β + decay of 8 B provides the dominant source of solar neutrinos above 2 MeV. Consequently, experiments that detect neutrinos from the sun require an accurate determination of the 8 B neutrino energy spectrum. In this work, the β -decay Paul trap surrounded by double-sided silicon strip detectors was utilized to precisely measure the decay products of trapped 8 B ions. The results were used to determine the 8 Be final-state distribution and to reconstruct the neutrino energy spectrum. This measurement using trapped ions is the first of its kind and puts the neutrino energy spectrum on much firmer footing by discriminating between recently reported values for the maximum of the final-state distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dibosons and other EWK measurements

The latest electroweak results from CMS, based on pp collision data taken at 13 TeV during Run 2, are presented. Precise measurements of multi-boson processes are reviewed and compared with theory predictions, sometimes showing measurements many times more precise than previous results. All results agree with the Standard Model, and where appropriate, limits are set on anomalous triple and quartic gauge couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PVEMC: isolating the flavor-dependent EMC effect using parity-violating inelastic scattering in SoLID

In order to better understand the EMC effect, we propose a clean and precise measurement of the flavor dependence of the EMC effect using parity-violating deep inelastic scattering on a 48 Ca target. This measurement will provide an extremely sensitive test for flavor dependence in the modification of nuclear parton distribution functions (PDFs) for neutron-rich nuclei. A measurement of the flavor dependence will provide new and vital information and help to explain nucleon modification at the quark level. In addition to helping understand the origin of the EMC effect, a flavor-dependent nuclear pdf modification could significantly impact a range of processes, including neutrino-nucleus scattering, nuclear Drell-Yan processes, and e-A observables at the Electron-Ion Collider. The parity-violating asymmetry A PV from 48 Ca using an 11 GeV beam at 80 μA will be measured using the SoLID detector, proposed for a series of measurements in Hall A at Jefferson Lab. In 68 days of data taking, we will reach 0.7–1.3% statistical precision for 0.2 < x < 0.7 with 0.6–0.7 systematic uncertainties. Here, the goal is to make the first direct measurement of the flavor dependence of the EMC effect. The precision of the measurement will allow for quantification of the flavor-dependent effects, greatly improving our ability to differentiate between models of the EMC effect and constraining the u- and d-quark contributions in neutron rich nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent advancements in atomic many-body methods for high-precision studies of isotope shifts

The development of atomic many-body methods, capable of incorporating electron correlation effects accurately, is required for isotope shift (IS) studies. In combination with precise measurements, such calculations help to extract nuclear charge radii differences, and to probe for signatures of physics beyond the Standard Model of particle physics. Here, we review here a few recently-developed methods in the relativistic many-body perturbation theory (RMBPT) and relativistic coupled-cluster (RCC) theory frameworks for calculations of IS factors in the highly charged ions (HCIs), and neutral or singly-charged ions, respectively. The results are presented for a wide range of atomic systems in order to demonstrate the interplay between quantum electrodynamics (QED) and electron correlation effects. In view of this, we start our discussions with the RMBPT calculations for a few HCIs by rigorously treating QED effects; then we outline methods to calculate IS factors in the one-valence atomic systems using two formulations of the RCC approach. Then we present calculations for two valence atomic systems, by employing the Fock-space RCC methods. For completeness, we briefly discuss theoretical input required for the upcoming experiments, their possibilities to probe nuclear properties and implications to fundamental physics studies.

QED effects↗

Opportunities for fundamental physics research with radioactive molecules

Molecules containing short-lived, radioactive nuclei are uniquely positioned to enable a wide range of scientific discoveries in the areas of fundamental symmetries, astrophysics, nuclear structure, and chemistry. Recent advances in the ability to create, cool, and control complex molecules down to the quantum level, along with recent and upcoming advances in radioactive species production at several facilities around the world, create a compelling opportunity to coordinate and combine these efforts to bring precision measurement and control to molecules containing extreme nuclei. In this paper, we review the scientific case for studying radioactive molecules, discuss recent atomic, molecular, nuclear, astrophysical, and chemical advances which provide the foundation for their study, describe the facilities where these species are and will be produced, and provide an outlook for the future of this nascent field.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signal processing and spectral modeling for the BeEST experiment

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.

6 ≤ A ≤ 19↗

Mid-infrared trace detection with parts-per-quadrillion quantitation accuracy: Expanding frontiers of radiocarbon sensing

Detection sensitivity is a critical characteristic to consider during selection of spectroscopic techniques. However, high sensitivity alone is insufficient for spectroscopic measurements in spectrally congested regions. Two-color cavity ringdown spectroscopy (2C-CRDS), based on intra-cavity pump–probe detection, simultaneously achieves high detection sensitivity and selectivity. This combination enables mid-infrared detection of radiocarbon dioxide ( 14 CO 2 ) molecules in room-temperature CO 2 samples, with 1.4 parts-per-quadrillion (ppq, 10 − 15 ) sensitivity (average measurement precision) and 4.6-ppq quantitation accuracy (average calibrated measurement error for 21 samples from four separate trials) demonstrated on samples with 14 C/C up to ∼ 1.5 × natural abundance ( ∼ 1,800 ppq). These highly reproducible measurements, which are the most sensitive and quantitatively accurate in the mid-infrared, are accomplished despite the presence of orders-of-magnitude stronger, one-photon signals from other CO 2 isotopologues. This is a major achievement in laser spectroscopy. A room-temperature-operated, compact, and low-cost 2C-CRDS sensor for 14 CO 2 benefits a wide range of scientific fields that utilize 14 C for dating and isotope tracing, most notably atmospheric 14 CO 2 monitoring to track CO 2 emissions from fossil fuels. The 2C-CRDS technique significantly enhances the general utility of high-resolution mid-infrared detection for analytical measurements and fundamental chemical dynamics studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SoLAr: Solar Neutrinos in Liquid Argon

SoLAr is a new concept for a liquid-argon neutrino detector technology to extend the sensitivities of these devices to the MeV energy range - expanding the physics reach of these next-generation detectors to include solar neutrinos. We propose this novel concept to significantly improve the precision on solar neutrino mixing parameters and to observe the "hep branch" of the proton-proton fusion chain. The SoLAr detector will achieve flavour-tagging of solar neutrinos in liquid argon. The SoLAr technology will be based on the concept of monolithic light-charge pixel-based readout which addresses the main requirements for such a detector: a low energy threshold with excellent energy resolution (approximately 7%) and background rejection through pulse-shape discrimination. The SoLAr concept is also timely as a possible technology choice for the DUNE "Module of Opportunity", which could serve as a next-generation multi-purpose observatory for neutrinos from the MeV to the GeV range. The goal of SoLAr is to observe solar neutrinos in a 10 ton-scale detector and to demonstrate that the required background suppression and energy resolution can be achieved. SoLAr will pave the way for a precise measurement of the 8-B flux, an improved precision on solar neutrino mixing parameters, and ultimately lead to the first observation of hep neutrinos in the DUNE Module of Opportunity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of H Λ 3 and H Λ 4 Lifetimes and Yields in Au + Au Collisions in the High Baryon Density Region

We report precision measurements of hypernuclei $^3_ΛH$ and $^4_ΛH$ lifetimes obtained from Au + Au collisions at $\sqrt{sNN}$ = 3.0 GeV and 7.2 GeV collected by the STAR experiment at the Relativistic Heavy Ion Collider, and the first measurement of $^3_ΛH$ and $^4_ΛH$ midrapidity yields in Au + Au collisions at $\sqrt{sNN}$ = 3.0 GeV. $^3_ΛH$ and $^4_ΛH$, being the two simplest bound states composed of hyperons and nucleons, are cornerstones in the field of hypernuclear physics. Their lifetimes are measured to be 221 ± 15 (stat) ± 19 (syst) ps for $^3_ΛH$ and 218 ± 6 (stat) ± 13 (syst) ps for $^4_ΛH$. The p T -integrated yields of $^3_ΛH$ and $^4_ΛH$ are presented in different centrality and rapidity intervals. It is observed that the shape of the rapidity distribution of $4_ΛH$ is different for 0%–10% and 10%–50% centrality collisions. Thermal model calculations, using the canonical ensemble for strangeness, describes the $^3_ΛH$ yield well, while underestimating the $^4_ΛH$ yield. Transport models, combining baryonic mean-field and coalescence (jam) or utilizing dynamical cluster formation via baryonic interactions (phqmd) for light nuclei and hypernuclei production, approximately describe the measured $^3_ΛH$ and $^4_ΛH$ yields. Our measurements provide means to precisely assess our understanding of the fundamental baryonic interactions with strange quarks, which can impact our understanding of more complicated systems involving hyperons, such as the interior of neutron stars or exotic hypernuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Beam Measurements of the Tianlai Dish Radio Telescope using an Unmanned Aerial Vehicle

Precision measurement of the beam pattern of an antenna is very important for many applications. While traditionally such measurement is often made in a microwave anechoic chamber or at a test range, measurement using an unmanned aerial vehicle offers a number of advantages: the measurement can be made for the assembled antenna on site, thus reflecting the actual characteristics of the antenna of interest, and more importantly, it can be performed for larger antennas which cannot be steered or easily measured using the anechoic chamber and test range. Here we report our beam measurement experiment with UAV for a 6 meter dish used in the Tianlai array, which is a radio astronomy experiment. Due to the dish's small collecting area, calibration with an astronomical source only allows for determining the antenna beam pattern over a very limited angular range. We describe in detail the setup of the experiment, the components of the signal transmitting system, the design of the flight path and the procedure for data processing. We find the UAV measurement of the beam pattern agrees very well with the astronomical source measurement in the main lobe, but the UAV measurement can be extended to the fourth side lobe. The measured position and width of each lobe also shows good agreement with electromagnetic field simulation. This UAV-based approach of beam pattern measurement is flexible and inexpensive, and the technique may also be applied to other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

Neutrino electromagnetic properties and the weak mixing angle at the LHC Forward Physics Facility

The LHC produces an intense beam of highly energetic neutrinos of all three flavors in the forward direction, and the Forward Physics Facility (FPF) has been proposed to house a suite of experiments taking advantage of this opportunity. In this study, we investigate the FPF’s potential to probe the neutrino electromagnetic properties, including neutrino millicharge, magnetic moment, and charge radius. We find that, due to the large flux of tau neutrinos at the LHC, the FPF detectors will be able to provide more sensitive constraints on the tau neutrino magnetic moment and millicharge than previous measurements at DONUT, by searching for excess in low recoil energy electron scattering events. We also find that, by precisely measuring the rate of neutral current deep inelastic scattering events, the FPF detectors have the potential to obtain the strongest experimental bounds on the neutrino charge radius for the electron neutrino, and one of the leading bounds for the muon neutrino flavor. The same signature could also be used to measure the weak mixing angle, and we estimate that sin 2 θ W could be measured to about 3% precision at a scale Q ∼ 10 GeV , shedding new light on the longstanding NuTeV anomaly. Published by the American Physical Society 2025

Abraham, Roshan Mammen (ORCID:0000000346783808)↗

Conversion of the LLNL/CAMS 1 MV biomedical AMS system to a semi-automated natural abundance 14C spectrometer: system optimization and performance evaluation

The Lawrence Livermore National Laboratory – Center for Accelerator Mass Spectrometry compact 1 MV biomedical accelerator mass spectrometer was repurposed and optimized for the semi-automated radiocarbon measurement of natural abundance environmental samples. Here we present results from 15 months of routine system operation and evaluate the system performance based on 30 sample wheels measured with consistent operating conditions over 7 months from August 2019 to March 2020. Additionally, the average measurement precision was 2.7 ± 0.7‰. System accuracy was assessed with measurements of 14 C-free materials, standard materials with 14 C-content spanning 0.5 to 1.5 F 14 C, and by comparison to split samples measured with the 10 MV AMS system. Overall, this system can routinely measure samples as small as 300 µgC and less than 33000 years without the need for size-specific correction protocols.

43 PARTICLE ACCELERATORS↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗